HomeMy WebLinkAboutseptic info CITY OF ORONO Date
ADDRESS Connected to
CODE SEPTIC SYSTEM INVENTORY CARD Municipal Sewer
Zlr DO/J<A A11 WELLDATA
Address Property .I.D.
O Standard trench P f. LCT- .S II
O Mound rn
System type *Other /U( )gn-- Legal Description y/,L/y0 - aS/D
_ C
r
Permit No. Date of permit Installer 'o p
d
No. Bedrooms Garbage E
Building type [�tB/N or GPD Laundry Dishwasher Disposal o Q
E a
SEPTIC TANKS: Material Capacity 1) 2) ° cr E
0
Z a
Proper outlet and inlet Baffles Liquid depth to RO level
m
Height of tank bottom above water tableDistance to nearest building N E
D
DRAINFIELD: Total length of lines Number of lines Trench width
Y
C
Total treatment area(sq.ft.) Height of drainfield above water table
U
Type of filter material Soil type a �•
N d
E L _
Distance from nearest bldg. Tile size Perc rate min/in ° d c
Depth of fill over drainfield Depth of rock over ti le under theo 4
10 E c —
p a 0
/UD P oL'I-rq0as67 /s -S7Z>,'eA61tF-- oivLy
LOCATION
INSPECTION RECORD PUMPOUT RECORD SKETCH
DATES COMPLIANCE DATE GALLONS
7Z— n.�O S(--PTlL
NowL LL nro i� , d LiTltous�
HAS urs
/Ot5 37-7?>k 4 C-s�
r-c-C�iN izxzy �"
Include: 1) Well location
2) Distance from house to
septic tanks,dist.box,
and drainfield
C— CONFORMING S—SUBSTANDARD N —NONCONFORMING 3) North arrow and road
SEPTIC SYSTEM INVENTORY
Addr: 225 Tonka Ave . PID: 05-117-23 13 0023
Building Type : residence # BRs/GPD: 2 # Systems/units : 1/1
Permit No: 7399 Date of Permit : 5/2/84 Installer: Halstad Contr.
System Type : standard trench Appliances : lndry, dshw
SYSTEM CONDITION
Conformity: 2 Tank Condition: 5 DF condition: 11
Failure Pot : medium
SEPTIC TANKS
Material : concrete block Capacity: 400, 400, 400
Setback to Bldg: 25
DRAINFIELD
Length of Lines : 190 No. Lines : 3 Trench Width: 3
Treatment Area: 600 Type of Filter: rock
Tile Size : 4 Under Tile : 12 Perc Rate mn/in: 4 . 5
Setback DF-Bldg: 40 DF Ht above WT:
Soil Type : loam Limitations :
WELL DATA
Setbacks - Well-Tanks : 50 Well-DF: 60
Report in File? : y Pump Type : subm.
Depth: 130 Diameter: 4 Method: drilled
INSPECTION RECORD PUMPOUT RECORD
Date Compliance Date Gallons
9/14/78 no surfacing s 5/1/84 800
5/3/84 added DF (600 sf) 2
12/14/87 no surfacing 2
4/3/89 no surfacing 2
7/31/90 no surfacing-pump tanks 2
6/6/91 no surfacing-pump tanks 2
II
6'
T, rh 60
RS/6 �3 'd
T r� pro q6'0
Og,
�sn 4SD