HomeMy WebLinkAbout2003-P07076 - mechanical CITY 'OF O RO N O PERMIT
Permit Number:
2750 Kelley Parkway- PO Box 66 P07076
Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits
(952) 249-4600 Date Issued: 12/9/2003
SITE ADDRESS: 3690 Togo Rd
Wayzata,MN 55391
PID: 17-117-23-31-0028
DESCRIPTION:
Proposed Use: Residential
Permit Class: General
Permit Type: Mechanical Permits Permit Sub-type(s): Heating Systems
DETAILS:
Approved per resolution#:
Separate permits required:
NOTICES/REMARKS:
FEE SUMMARY: Permit Fee: $ 90.94 Valuation: $ 7,275.00
State Surcharge Fee: $ 3.64
Fee: $ 1.50
......._. ...._.TOTAL FEE: $ 96.08
APPLICANT' Home Energy Center(See Comments) OWNER: Timothy Roberts
15200 25TH Avenue N, Suite 128 3690 Togo Rd
Plym&uih,Mg 55447 Wayzata MN 55391
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED
AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF
MINNESOTA BUILDING CODE REQUIREMENTS.
4APPLICANT PERMITEE SIGNATURE SUED BY SIGNATURE
Conies: 1-File(Siknitures Required), 1-Aw icant, 1-Monthly Reports, 1-Assessim 1-Finance Page 1
t . .
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT
Box 66 (2750 Kelley Parkway) RECEIVED
Crystal Bay, MN 55323
GENERAL INFORMATION DEC 0 9 2005
1. You may apply for mechanical permits by mail or in person at the City offices. & 6o�sw
Rll be
reviewed and a permit will be issued within 2 working days. UVJ Oi
NO
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL
YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON
THE JOB SITE.
3. Mechanical Designs - Complete calculations, details and specifications are required for each heating,
ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain
calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model.
Data shall be presented on form provided. Identification of and specifications for water heating equipment
shall also be provided.
4. When any new construction or remodeling is involved, a separate building permit must be obtained.
5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements.
6. All work must be inspected(rough-in and final). Call 249-4600. 24-hour notice required.
7. House Heating Test Record must be submitted before final.
Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification.
INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600.
Please check one: New Addition Repair ✓Replace
Residential Commercial
JOB SITE: (Q -70 To- o F_ J, Zip: 5 -S 3 y
Owner's Name: -'w, o+I b t r �-s Telephone Number:'4)5a - 47 1 - 6 SS
Mailing Address: .J6 ct.d T ti R4 . City: LA)-,Xz�,+kt Zip: 5 S 3 1
Contractor's Name: m F C 4 t.2 Y Ct h &_ Telephone Number: '1(03 - q 7 6-1 f 4 a
Mailing Address: f Sa Q s�u ,4•F a *--I z1r City: n-a K r14 Zip:yvt rj <,5,447
SYSTEM DESCRIPTION
HEATING SYSTEMS
Quantity:
Make: p
Model: V a 75
Fuel: N I aS
Flue Size:
Input BTUs: H S, rol
Output BTUs: N S9 F rzry
CFM:
COOLING SYSTEMS
Quantity:
Make:
Model:
Tons:
H. Power
FIREPLACES
Gas factory fireplace
Wood burning factory fireplace with flue
Wood Stove
Wood stove with flue
Brand Name Model No.
VENTILATION
No. Kitchen Exhaust ducted recirculating cfm
No. Bath Exhaust (must be ducted outside) cfm
No. Other Fans: Locations cfm
FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL)
Installation Removal
Fuel oil: gallons underground inside outside
LP Gas: gallons
Other Gas opening
PERMIT FEE CALCULATION
1. 1.25% of Contract Price* or Minimum Fee ($35.00)
-7.2 7 S x .0125 $ c1 Q
(contract price)
2. State Surcharge. ** Add the State Building Code Division
Surcharge to each permit. -7a -7 5 x .0005 $ 3
or $.50, whichever is greater (contract price)
3. Postage and Handling (Only mail-in applications) $ 1.50
4. TOTAL PERMIT FEE (Add lines 1-3 above) $ _ o li
* CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted
work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer
for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or
any other party the reasonable market value of such items must be added to the estimated cost or contract
price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may
request the submission of a signed copy of the actual contract.
** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 -whichever is greater.
For valuations over $1,000,000 call the Department of Inspectional Services for the price.
The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all
work in strict accordance with the ordinances of the City and the regulations of the Minnesota
State Building Code, and certifies that all statements made on this application are complete, true
and correct.
Applicant's Signature: - ru-, Date:
Approved By: Date:
RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
Home Energy Center
15200 25th Avenue North,Plymouth,MN 55447 Phone:763.476.1990 Fax:763.476.1143
Project • •
For: Proberts
3690 Togo Road, Wayzata, MN
Notes:
Design Inf• •
Weather: Minneapolis-St. Paul, MN, US
Winter Design Conditions Summer Design Conditions
Outside db -22 OF Outside db 91 OF
Inside db . 70 OF Inside db 75 OF
Design TD 92 OF Design TD 16 OF
Daily range M
Relative humidity 50 %
Moisture difference 29 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Building heat loss 47204 Btuh Structure 0 Btuh
Ventilation air 0 cfm Ventilation 0 Btuh
Ventilation air loss 0 Btuh Design temperature swing 3.0 OF
Design heat load 47204 Btuh Use mfg. data n
Rate/swing multiplier 0.96
Infiltration Total sens. equip. load 0 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Internal gains 0 Btuh
Ventilation 0 Btuh
Heating Coolingg Infiltration 0. Btuh
Area(ft2) 900 0 Total latent equip..load . _ 0 Btuh
Volume(f 3) 7200 0
Air.changes/hour 1.2 0.5 Total equipment load 0. Btuh
Equiv.AVF(cfm) 144 0
Heating Equipment Summary Cooling.Equipment Summary
Make Make
Trade Trade
Efficiency 80.0 AFUE Efficiency 0.0 EER
Heating input 0 Btuh- -Sensible cooling - 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Heating temp rise 0 OF Total cooling 0 Btuh
Actual heating fan 0 cfm Actual cooling fan 0 cfm
Heating air flow factor 0.000 cfm/Btuh Cooling air flow factor 0.000 cfm/Btuh
Space thermostat Load sensible heat ratio 0 %
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
Ai�:--� w
!!� rightsoft Right-Suite ResidentialTM 5.0.28 RSR20001 2003-Deo-02 11:32:13
AC.C.A C:\Wrightsoft HVAC\2003WABasicLoad.rsr Page 1
RIGHT-J WORKSHEET
Entire House
Home Energy Center
15200 25th Avenue North,Plymouth,MN 55447 Phone:763.476.1990 Fax:763.476.1143
�� MANUAL J:7th Ed.
I 1 I Name of room Entire House Proberts
1 21 Length of exposed wall I 120.0 ft 1 120.0 ft I I I
3 Room dimensions 30.0 x 30.0 ft
4 Ceiings Condit.Option 8.0 fti heat/cool d 8.0 ft heat only
TYPE OF CS HTM Area Load(Btuh) Area Load(Btuh) Area Area
EXPOSURE NO. Htg I Clg (ftp Htg Clg (ftj Htg Clg Htg Clg Htg Clg
5 Gross a 12A 24'915.3 960 '•" '•'» 960 *"» *"' "'• »'"' "" `""
Exposed b I 0.0 0.0 0 ""' `*" 0
I I walls and I c l 1 0.01 0.01 01 "*' 1 1 01 "`* I ••"" I I '•" I "" I I �" I """ I
I I partitionsI d I 1 0.01 0.01 01 "•' 1 »*'* 1 01 »"* 1 ••'• 1 1 '•'• I '•" I I "" I .... I
e 0.0 0.0 0 0
f 0.0 0.0 o .,,, ,,,, 0
6 Windows and a 2A 1 43.7 "' 112 4894 '**' 112 4894 •*"
glass doors b 0.0 " 0 0 "" 0 0
I I Heating I d 1 1 0:01 ** 1 01 01 `," 'I i 0
1 1 0I ` I I ( "'• I I I "" I
lel l01 I I
f 0.01 101 0 ,,•• 01 01 ,,,, 1 1 1 ,••, 1 1 •,,,
7 Windows and North 0.0 30 '"" 0 30 *"*' 0
glass doors NE/NW 0.0 0 "" 0 0 '•*' 0
I I Cooling I EIW I 0.01 361 "•• I o 1 361 •**, I
SE/SW 0.0 0 0 0 ""' 0
I South I 0.0) 461 "•' l 0 46 I '"'" I o l I I I I ""
81 Other doors 1,110171 29.41 6.3 42 12361 01 421 12361 0
I I I bl 1 0.01 0.01 01 01 01 01 01 01 1 1 1 1 1 1
Icl 1 0.01 0.01 01 01 01 01 01 0
91 Net JaI12AI 24.91 5.31 8061 200951 01 8061 200951 0
I I exposed I b l 1 0.01 0.01 01 01 01 01 01 01 1 1 1 1 1 1
walls and
partitions I c dI 1 0.00.01 O.o0.0 0 0 0 0 0 0I 0I 0� of OI 0I of I I I I I
I I I el 1 0.01 0.01 01 01 01 01 01 01 1 1 1 1 1 1
Ifl 1 0.01 0.01 01 01 01 01 01 0
�10 Ceilings I a 16D 4.9 2.1 900 4388 0 900 4388 0
I I I bl 1 0.01 0.01 01 01 01 01 01 01 1 1 1 1 1 1
dl 10.000 of oo ooa. I I I I I I I I I I
I I lel 1 0.01 0.01 01 01 01 01 01 01 1 1 1 1 1 1
Ifl 1 0.01 0.01 01 01 01 01 01 0
�11 Floors I a 21A 2.2 0.0 900 1987 0 900 1987 0
(Note:
room I cI I 0.01 0.01 0 OI oI oI OI °I
0.0 0.0 0 0 0 0 0 0
1 1 is displ. I d l 1 0.01 0.01 01 01 01 01 01 01 1 1 1 1 1 1
I Ifor slab I e 1 1 0.01 0.01 01 01 01 01 01 01 1 1 1 1 1 1
floors) Ifl 1 0.01 0.0 01 01 01 01 01 0
12 Infiltration a 94.8 8.0 154 14602 0 154 14602 0
13 Subtotal loss=6+g +11+12 "" 47204 ":"' "*' 47204
I I Less external heating I - 01 01 .,,, 1 .,.,0o/I 01 „ I ,,,, Q/J I ••* i ", o/a I «„
Less transfer '•" I 0 0
14 I Duct loss I 0/d I I I
15 Total loss=13+14 1 1 472041 1 472041 1 "'* 1 1
16 Int.gains: People @ 3000 "'• 0 0 '"•' 0
Appl. @ 1200 0 0 0 �' 0
1171 Subtot RSH gain=7+8..+12+16 I *�• I �� 1 01 '•" 1 1 01 '�' 1 *"' 1 1 ""
Less external cooling 0 '•'* ""* 0
Less transfer I ,.,, I "„ I 01 „" I I of I "• I I I
1181 Duct gain 1 00/4 "" 1 01 0014 ,,,, 1 01 0/4 „» 1 1 °id "" 1 1
I20I A�required ain=(cfmj 8)'PLF I X1.00 01 0I 1.Oo I 01 0I I I I I
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
. .� ws^sghtsoft Right-Suite Residential'*'5.0.28 RSR20001 2003-Dec-02 11:32:13
Am C:%Wrightsoft HVAC\2003\AABasicLoad.rsr Pagel
HOUSE HEATING TEST RECORD _?0?
ADDRESS 3�y 6 0 APT.-_F,4OR Cl b N a
OCCUPANT OWNER
HEAT LOSS DATE HTG. INST.
SOLD BY HOME ENERGY CENTER INSTALLED BY HOME ENERGY CENTER
Electrical Work By HARRISON ELECTRIC Gas Line By
TYPE OF HEAT GA FA X HW STEAM SPACE HTR. UNIT HTR. OTHER
MAKE c MAKE OF BURNER
Model G Model
Serial Max. BTU Rating Us 244
INPUT MAKE OF FURNACE
Model `
� wivo
THERMOSTAT Heat Plu Vent Size
Valve �� KIND OF LINER SIZE NONE
Limit Draft Hood Regulator.
Limit Setting Filters Size Number`
Fan Setting Chimney Location InsidO Outside
Pilot Type Chimney Construction
Pilot Make
Pilot Model ` Smoke Bomb i Wiring
Pilot Timing Draft Test Tag
L.W.Cut Off Door Pressure ,' Lighting Inst.
Pressure Percent CO2 Date Tested
Input CFH Percent 02 Company a ENERGY CENTER
1 j ,
Stack Temp. Percent CO Name of Tester
f
Form 235