HomeMy WebLinkAbout2006-fire code inspection EXCELS/OR FIRE D/ETR/CT — FIRE CODE & SAFETY /NSP
ECT/ONS
24 100 SMITHTOWN ROAD SHORE—W000 M/1VNE307'A 553-71
INSPECTOR 2 KELLIE MURPHY-R/NGATE 952.960.1692 JUnurpLyringategeKeelsiorfiMorg
INSPECTOR 3 LEE BERGLUND 952.960.1693 Ib und@e=eleion%n-_o
rff
OCCUPANCY: DATE: KNOX: TYPE:
�1 t-fQ11�-1- 5 i�>C77V SSS G
N REI SP: SPR SYS: ALARM:
ADDRESS: EMERGENCY
CONTACT:
PHONE: 7mERr.ENCY / Z F v!'T�/
PHONE #: "/�Cj l ✓ C.� O
Inspection of the occupancy listed above been DEEPHAVEN COMMENTS:
completed in accordance with the 2000 IFC and EXCELSIOR
the MSFC adopted by the city of:»»»» GREENWOOD
The following violations and/or deficiencies SHOREWOOD
requiring corrective action are noted below. O NO ONKA BAY
EXTERIOR: # FIRE PROTECTION SYSTEMS: #
Address visible and legible-Front and rear doors 1 Sprinkler heads in good condition-proper coverage 21
Fire hydrants accessible-36" minimum clearance 2 Door to sprinkler system control room marked
Fire lanes-Fire Department access 3 Riser&control valves accessible/current ins ection
FDC unobstructed &visible-proper ca -3'clear 4 Control valves locked open or tamper protected
Horn/strobe operational-unobstructed&visible 5 Extinguishers properly located-current inspection 25
Knox Box with properly labeled keys 6 Commercial hoods stems-clean &inspected 26
Dum sters minimum 5' from building 7 Class K extinguisher present in commercial kitchen 27
Gas meters &piping protected 8 Fire alarm system in good condition-inspected
Building exterior maintained 9 Door to fire alarm room identified
EXITS: # INTERIOR/STORAGE: #
Exit doors unobstructed, operable, proper hardware 10 Storage 18" or more below sprinkler heads 30
Exit corridors maintained and unobstructed 11. Storage 24" or more below unprotected ceilings 31
Exit signs illuminated 12 No storage in unprotected attics or below stairs 32
Pro er exit signs di--'-- ed-6" minimum letters 13 No storage in mechanical or electrical panel rooms 33
EmergencyEmeEgency lighting in good operating condition 14 No storage in boiler or elevator equipment rooms 34
Occupancy load posted (assembly) 15 Trash &oily rags properly kept or removed daily 35
ELECTRICAL EQUIPMENT: # Flammable and combustible liquids properly stored 36
Door to electrical room/panel labeled 16 Hazardous materials properly stored and identified 37
30" clear access to electrical panels 17 Compressed gas cylinders properly secured 38
Open spaces in electrical panels-knockout plugs 18 Ceiling tiles in place&undamaged 39
Electrical hazards-power strips/circuit protected 19 Wall or ceiling damage repaired/seal penetrations 40
No extension cords used as permanent wiring 20 Smoke detectors operational/propeE location 41
Code Violation Summary:
uN r
/�-k./V �! V 7 1 1�-11L-J�C1 F _i� �./ r
The Fire District reserves the right to enforce the
MSFC if any other violations are discovered during
the compliance process or as they may arise.
Signature indicates receipt of copy
and cooperation with compliance
Owner or Representative Excelsior Fi-re-06trictf6spector orders within days.