Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2005-P09450 - mechanical
PERMIT CITY-OF ORONO 2750�IClelley Parkway- PO Box 66 Permit Number: P09450 Crystab Bay, Minnesota 55323 Permit Type: Mechanical Permits (952)249-4600 Date Issued: 11/28/2005 SITE ADDRESS: 3645 Togo Rd Unit# Wayzata,MN 55391 PID: 17-117-23-31-0034 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 104.38 Valuation: $ 8,350.00 State Surcharge Fee: $ 4.18 Misc.Fee: $ 1.50 TOTAL FEE: $ 110.06 APPLICANT: Sedgwick Heating&Air Conditioning Inc. OWNER: Anthony Reed 8910 Wentworth Avenue S 3645 Togo Rd Minneapolis,MN 55420 Wayzata MN 55391 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. APPLICANT PERMITEE SIGNATURE D BY SIGNATURE Copies: 1-File(Signatures Required), 1-Applicant, 1-Monthly Reports, 1-Assessing,(If Septic, 1-Septic) Page 1 CITY OF ORONO APPLICATION FOR MECHANICAL PERIYIIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation,humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call 473-7357. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 473-7357. Please check one: New Addition Repair Replace Az_ Residential Commercial JOB SITE: ' Zip: S_3,i Owner's Name: Telephone Number: 1 -X71- 3 Mailing Address: _. City: Zip: Contractor's Name: SEDGMCK HEATING&AIR CONDITION!"!�'@L1el�honeNumber: MailingAddress: 8910 Wentworth Ave. Cc City: Zip: Minneapolis, MIN 55420 SYSTEM DESCRIPTION _(952)881-9000 HEATING SYSTEMS Quantity: J2 Make: 1 Model: Fuel: _ Flue Size: Input BTUs: ZOO _ Output BTUs: CFM: COOLING SYSTEMS Quantity: Make: Model: L/ Tons: oL H. Power WOOD BURNING EQUIPMENT Wood stove with flue Wood combination or add-on Factory fireplace with flue Factory Fireplace (s) Freestanding Masonry Wood Stove (s) Franklin, other Brand Name Model No. Mfgr's Min-, Clearances, side rear min. flue dia. Total VENTILATION No. Kitchen Exhaust ducted recirculating cfm No. Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations cfm Total FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) r� D" x .0125 $ lb Ll -ilk (contract price) 2. State Surcharge. ** Add the State Building Code Division Surcharge to each permit. x .0005 $ ^/V (contract price) or $.50, whichever is greater 3. Postaize and Handling (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under $1,000,000 or $.50 - whichever is greater. For valuations over $1,000,000 can the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: Date: 1 6�s Approved By: Date: Se,dgwkk EAT� &AIR CONDITIONING cO. RESIDENTIAL HEATING DATA SHEET omfort you can count on JOB NAME: DATE ADDRESS: C.--A k OUTDOOR TEMP: -2tl INDOOR TEMP: TEMP. DIFFERENCE: o DESIGN TEMPERATURE DIFFERENCE BTUH MOVABLE GLASS WINDOWS SnE TRE 30 35 40 45 50 55 60 65 70 75 80 85g0 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS 39 1 45 1 52 1 58 1 65 171 178 1 84 1 90 1 97 11031110 11161123 SINGLE GLASS W/STORM 21 1 25 1 28 1 31 135 1 38 142 1 45 1 49 1 52 1 56 1 59 1 63 1 66 DOUBLE GLASS 28 32 1 37 1 41 1 46 1 50 1 55 1 60 1 64 1 69 1 73 1 78 87 11. DOUBLE GLASS W/STORM 16 19 1 21 1 24 1 27 t 29 1 32 1 35 1 37 1 40 1 42 1 45 1 48 1 50 DESIGN TEMPERATURE DIFFERENCE BTUH SLIDING GLASS DOORS SQUARE TRE ET 30 35 1 40 145 1 50 1 55 1 60 1 65 1 70 1 75 1 80 1 85 90 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SINGLE GLASS 42 1 48 1 55 1 62 169 176 1 83 1 90 1 97 1104 1110 1117 11271131 [SINGLE GLASS W/STORM 22 26 29 33 37 40 144 48 51 55 59 62 4 66 70 DOUBLE GLASS 29 1 34 1 39 43 48 53 1 58 63 67 72 T7 1 82 1 87 91 SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH DOORS FEET 30 35 40 1 45 1 50 1 55 1 60 1 65 1 70 1 75 1 80 1 8590 95 HEAT LOSS HEAT TRANSFER MULTIPLIER SOLID WOOD 31 36 41 1 46 1 51 1 56 1 62 167 1 72 1 77 1 82 1 87 192 97 SOLID WOOD" 18 21 24 27 30 33 36 39 142 1 45 1 47 1 50 a2l 56 METAL URETHANE 23 27 30 1 34 38 1 42 1 45 1 49 1 53 1 57 60 1 64 1 68 1 72 METAL URETHANE" 13 16 18 1 20 22 125 127 129 1 31 1 33 36 1 38 1 40 142 "Weatherstripped or Storm RUNNING FEET CEILING HEIGHT X WALLS GROSS WALL WINDOWS & DOOR AREAS NET WALL AREA SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH FRAME WALL FEET 30 1 35 1 40 1 45 1 50 1 55 160 1 65 1 70 175 1 80 1 85 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 8 10 11 12 14 15 1 17 18 19 1 21 1 22 23 2.1i, 26 R-11, 3" INSULATION 1 08b 2.7 3.1 3.6 4.0 4.5 4.9 5.4 5.8 6.3 g6.77�.2 7.6 8.5 R-13, 3-1/2" INSULATION 2.1 2.4 2.8 3.2 3.5 3.8 4.2 4.6 4.9 5.9 6.3 6.6R-13 + 1" POLYSTYRENE 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 5.1 5.4 5.7 R-19 + 1/2" POLYSTYRENE 1.6 1.9 2.2 2.5 2.8 3.0 3.3 3.6 3.8 4.7 4.9 5.2 MASONRY WALL SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH ABOVE GRADE FEET 30 1 35 1 40 1 45 1 50 155 160 1 65 1 70 1 75 1 80 1 85 1 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 16 18 21 23 26 28 31 33 36 38 41 44 R-5, 1" INSULATION 4.3 5.0 5.8 6.5 7.2 7.9 8.6 9.4 10.1 10.8 11.5 12.2 13.0 13.7 R-11, 3" INSULATION 2.3 2.7 3.1 13.5 3.8 14.2 14.6 5.0 5.4 5.8 6.2 6.5 6.9 7.3 R-19, 6" INSULATION 1.4 1.7 1.9 2.2 2.4 2.6 2.9 3.1 13.4 13.613.8 4.1 14.3 1 4.6 MASONRY WALL SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH BELOW GRADE FEET 30 1 35 1 40 1 45 1 50 1 55 1 60 1 65 1 70 175 180 1 85 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 4.4 5.1 5.9 6.6 7.3 8.1 8.8 9.610.311.011.812.5 3. 14.0 5S R-5, 1" INSULATION 2.6 3.0 3.5 3.9 4.3 4.8 5.2 15.716.1 16.517.0 t7.4 7.8 8.3 R-11, 3" INSULATION 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 14.2 14.514.8 15.1 15.4 5.7 R-19, 6" INSULATION 1.2 1.4 1.6 1.8 2.0 12.2 12.4 12.6 2.8 3.0 3.2 13.4 13.6 3.8 HEAT LOSS SUBTOTAL 1 A , Heat Loss Subtotal from Page 1 �Z , SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH , CEILING FEET 30 1 35 1 40 1 45 1 50 55 1 60 1 65 1 70 1 75 1 80 1 85 95 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 18 1 21 24 27 30 1 33 36 39 1 42 45 48 51 54 57 R-11, 3" INSULATION 2.6 3.1 3.5 4.0 4.44-.8 -5.3 5.3 5.7 6.2 6.6 7.0 7.5 17.9 8.4 R-19, 6" INSULATION 7 0'ck 1.6 j 1.9 2.1 2.4 2.6 2.9 3.2 3.4 3.7 -4-0--47-2- __ 4.5 4.8 5.0 R-30, 10" INSULATION 1.0 1.2 1.3 1.5 1.6 1.8 2.0 2.1 2.3 2.5 2.6 2.9 R-38, 12" INSULATION 0.8 0.9 1.0 1.2 1.3 1.4 1.6 1.7 1.8 2.0 2.1 2.2 12.3 2.5 FLOOR OVER AN SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH UNCONDITIONED SPACE FEET 30 35 40 1 45 1 50 1 55 60 65 1 70 175 1 80 1 85 1 90 HEAT LOSS HEAT TRANSFER MULTIPLIER NO INSULATION 10 11 13 1 14 1 16 1 17 19 21 22 24 25 1 27 1 28 1 30- R-11, 3" INSULATION 2.4 2.8 3.2 1 3.6 1 4.0 14.4 14.8 5.2 5.6 6.0 6.4 6.8 17.2 7.6 R-19, 6"INSULATION 1.6 1148 12.1 12.3 12.6 12.9 13.1 3.4 3.6 3.9 4.2 4.4 d.7 14.9 R-30, 10"INSULATION 1.1 11.3 1 1.5 11.7 11.8 12.0 12.2 2.4 2.6 2.8 3.0 13.1 13.3 13.5 SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH BASEMENT FLOOR FEET 30 1 35 1 40 1 45 1 50 1 55 1 60 1 65 1 70 1 75 ' 80 1 85 90 95 HEAT LOSS HEAT TRANSFER MULTIPLIER BASEMENT FLOOR 5 0.8 11.0 11.1 1 1.3 1 1.4 11.5 1147 11.8 12.0 12.1 12.2 12.4 l .5 D27 DESIGN TEMPERATURE DIFFERENCE CONCRETE SLAB WITHOUT LINEAR BTUH PERIMETER SYSTEM FOOT 30 35 1 40 1 45 1 50 1 55 1 60 1 65 1 70 1 75 1 80 1 85 1 90 96 HEAT LOSS HEAT TRANSFER MULTIPLIER NO EDGE INSULATION 25 29 33 1 37 1 41 1 45 1 49 1 53 1 57 1 61 65 69 1 73 1 77 1" EDGE INSULATION 13 15 17 1 19 121 1 23 1 25 127 129 131 1 33 35 1 37 139 2" INSULATION 1 6.3 17.4 18.4 19.4 10.5 11.5 12.6 13.6 14.7 15.8 16.817.8118.9 20.0 CONCRETE SLAB LINEAR 3U 35404550556065 � � 80DESIGN TEMPERATURE DIFFERENCE 851 901 95 HEAT WITH PERIMETER SYSTEM FOOT HEAT TRANSFER MULTIPLIER HEAT LOSS NO EDGE INSULATION 57 1 67 1 76 1 86 95 1105 1114 1124 1133 1143 1152 1162 1171 1181 1" EDGE INSULATION 34 40 1 46 52 57 163 1 69 74 1 80 86 1 91 1 97 1 103 1109 2" EDGE INSULATION 28 33 1 37 42 47 1 51 1 56 61 1 65 70 1 75 1 79 1 84 1 89 An additional infiltration load is calculated only if the home is loosely constructed or when window infiltration is greater than .5 CFM per linear foot of crack. FLOOR SQ FT. x CEILING HEIGHT = CUBIC FT INFILTRATION/ VENTILATION 0.40 x CUBIC FT - 60 = CFM MECHANICAL VENTILATION CFM = FRESH AIR INTAKE DESIGN TEMPERATURE DIFFERENCE BTUH CFM 30 35 40 45 150 155 160 165170175 180 185 95 HEAT LOSS HEAT TRANSFER MULTIPLIER INFILTRATION 33 39 1 44 50 1 55 1 61 1 66 72 1 77 1 83 1 88 9d 105 MECHANICAL VENTILATION 33 39 1 44 50 1 55 161 1 66 72 1 77 1 83 1 88 1 94 IL 105 HEAT LOSS SUBTOTAL DUCT LOSS BTUH HEAT LOSS R-4, 1" Flexible Blanket Insulation: ADD 15% 1.151 R-7, 2" Flexible Blanket Insulation: ADD 10% 1.101 TOTAL HEAT LOSS NOTE: All Heat Transfer Multipliers from ACOA Manual "J" Sixth Edition. HL-841-1-7 002344 Litho U.S.A.