Loading...
HomeMy WebLinkAboutseptic info jan za ZUib U/'U4PM HP FaxRusty Olson 7634988290 page 1 Fax Transmittal Form Date: 1/28/2016 Total Pages: 116 To; City of Orono Phone Number: Fax Number: 952-249-4616 E-mail: From: Joseph J Olson Phone Number. 763-498-8779 Fax Number: 763-498-8290 E-mail.- rL Sty26 54(E7camcast net ❑ urgent Q For Rev ew ❑ Please Comment ❑ Please Reply Message: This is the septic cert for 2575 Thoroughbred Lane.. Please file. Jan 28 2016 07:04PM HP FaxRusty Olson 7634988290 page 2 Minnesota Pollution Control Agency Compliance Inspection Form 520 Lafayette Road North Existing Subsurface Sewage Treatment Systems St.Paul,MN 55155-4194 ($STS) Doc Type.Compl/ante and Enfomemeni Instructions: Inspection results based on Minnesota Pollution Control Agency(MPGA) j For local trad requirements and attached fomlq—additional local requirements may also apply. Submit completed fonm to Local Unit of Government(LUG)and system owner JAN 2 11116 within 15 days System Status CnyOFORON ) System status on data(mm/dd/yyyy); 1/27/2016 ® Compliant-Certificate of Compliance ❑Noncompliant-Notice of Noncompliance (Valid for 3 years from report date, unless shorter time frame outlined in Local Ordnance.) (See Upgrade Requirements on page 3) Reason(s) for noncompliance(check all applicable) ❑ Impact on Public Health(Compliance Component #1)-Imminent threatto public health and safety ❑Other Compliance Conditions(Compliance Component#3)—Imminent threat to public health and safety ❑Tank Integrity(Compliance Component #2)—Failing to protect groundwater ❑Other Compliance Conditions(Compliance Component#3)—Failing to protect 9nwndwater ❑Soil Separation (Compliance Component #4)—Failing to protect groundwater ❑Operating permit/monitoring plan requirements(Compliance Component #5)—Noncompliant Property Information Parcel DO or Sec/Twp/Range: 0¢117-23-11-0021 Property address: 2575 Thoroughbred Lane Orono,MN Reason for inspection: Property owner. Steven Sapletal Property Transfer or Owner's phone: 612-708-2556 Owner's representative: Local regulatory authority: C!Y of Orono Representative phone: 2-1300 gallon septic tanks,1-1300 lion lift stationeand 630 ory authority phone; 952-244600 Brief system description: records square fast of mound rockbed.per city Comments or recommendations: Certification I hereby c@n'yy that ail the necessary information has been gathered to determine the compliance status orchis system. No determination of future system performance has been nor can be made due to unknown conditions during system possible abuse of the system,inadequate maintenance, or future water usage. construction, Inspector name: Joseph J Olson Business name: Rust OI 's Soil&Perc.TestingCertification number: 1255 License number: 810 Inspector signature: Phone number: 763-498-8779 Necessary or Locally Zequi�redAttnhrnents ®Soil boring logs ®System/As-built drawing ❑Forms ❑Other information(list): Per local ordinance www-pca.state.mn.us - 651.296-6300 . 800.657.3864 TTY 651.282.5332 or 800.657-3864 Available in alternative formats wq-wwlsts4.31 . 1124112 Page 1 of 3 Jan 28 2016 07:04PM HP FaxRusty Olson 7634988290 page 3 Property address: 2575 Thoroughbred Lane Orono MN Inspector initials/Date: J.0. 1/27/16 I. Impact on Public Health—Cornpliance component#1 of 5 Compliance criteria: Verification method(s): System discharge sewage to the ❑Yes ®No ® Searched for surface outlet round surface- ® Searched for seeping in yardJbackup in home System discharge sewage to drain tile ❑Yes ®No ❑ Excessive ponding in soil system/D-boxes or surface waters. ❑ Homeowner testimony(See Comrnents/Exptanatlon) System cause sewage backup into ❑Yes ®No ❑ "Black Boll'above soil tlispersal system dwelling or establishment ❑ System requires"emergency"pumping Any"yes"answer above Indicates the system is ❑ Performed dye test an Imminent Threat to Public Health and Safety. ❑ Unable to verity(See CammentvExtuanation) Comments/Explanation: ElOther methods not listed(See Comments/Explenatron) 2. Tank Integrity—Compliance component#2 of 5 Com liance criteria: Verification method(s): System consists of a seepage pit. ❑Yes ®No ® Probed tank(s)bottom cesspool,drywall,or leaching pit. Seepage pits meeting 7080.2550 maybe ® Examined construction records compliant 9 alknved in total ordinance ❑ Examined Tank Integrity Form(Attach) Sewage tank(s)leak below the!r103 Observed liquid level below operating depth designed operating depth. ❑Yes ®No ❑ Examined empty(pumped)tanks(s) If yes,which sewage tanks)leaks: ❑ Probed outside tank(s)for"black soil" ElUnable to verify(See commentwExplanatton) Any"yes"answer above indicates the system is Failing to Protect Groundwater. ®Other methods not listed(See comment&Exptanation) Co mmen ts/Explanati o n: Alban septic Company varified the tanks 3" Other Compliance Conditions—Compliance component#3 of 5 a. Maintenance hole covers are damaged,cracked,unsecured,or appear to structurally unsound. []yea* O No ❑unknown, b. Other issues(etecbkWhazards,etc.)to immediately and adversely impact pubic health or safety. ❑Yes• ONO ❑Unknown 'SY810M is an Imminent threat to public health and safety Explain: c. System is non-protective of ground water for other condition as determined by inspector ❑yes* ®No 'System is falling to protect groundwater Explain: www.pca.state.mn.us 651-296-6300 800-657-3864i wq-ww/sts4-31 • 1/24112 TTY 651 282 5332 or 800.657-3864 Available in alterative formats Page 2of3 jan Lts LUl b U 1:U4F" HN FaxRusty Olson 7634988290 page 4 Property address: 2576Thor-ogghbred Lane Orono MN Inspector initials/Date: J-0-J. 0, 1127/16 4. Soil Separation—Compliance component#4 of 5 Date of installation: 6127197 ❑ Unknown Verification method(s): ShorelandWallhead protecdoNFood @overage ❑Yes ®No Lodging? Soil observation does not expire.Previous soil observations by two independent parries are sufficient, Compliance criteria: unless site oori tions have been altered or local For systems built prior to April 1, 1996,and ❑Yes ❑No requirements differ. not located in Shoreland or Wellhead ® Conducted soil observation(s)(Attach boring lops) Protection Area or not serving a food, ❑ Two previous verifications(Attach boring logs) beverage or lodging establishment ❑ Not applicable(Hoding tank(s),no drainfreld) Dralnflald has at least a two-foot vertical ❑ Unable to verify(See Commentsexplanation) separation distance from periodically ❑ Other(See commentslExplanafion) Non-performance systems built April 1, i ®Yes ❑ No CommentsiExplanation: 1996,or later or for non-pedhrmanrae systems located in Shoreland or Wellhead Protection Areas or serving a food, beverage,or lodging establishment Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.* Experimental; *Other,or Performance" ❑Yes ❑ No Indicate depth*of elevations systems built under pre-2008 Rules, Type 1V or V systems built under 2008 Rules(7080. A. Bottom of distribution media 101.0 2350 or 7080.2400 (Advanced Inspector License required) B. Periodically saturated soiubedrock 98.2 Drainfield meets the designed vertical separation distance from periodically C. System separation 2.8 saturated soil or bedrock. D. uired compliance se ration" 2.6 Any "no"answer above/ndlcatea the system is *may be reduced up to 15 percent if allowed by Local Falling to Protect Groundwater. Ordinance. 5. Operating Permit and Nitrogen BMP*—compliance component#5 of 5 ® Not applicable Is the system operated under an Operating Permit? ❑Yes ❑ No If"yes",A below is required Is the system required to employ a Nitrogen BMP? ❑Yes ❑ No If"yes",B below is required BMP=Best Management Prwhw(s)specified in the system design N the answer to both questions is -no",this secdon does not need to be completed. Compliance criteria a. Operating Permit number: Have the Operating Permit requirements been met? i ❑Yes ❑No b. Is the required nitrogen BMP in place and properly functioning? ❑Yes ❑No Any"no"answer Indicates Noncompliance. Upgrade Requirements(Minn. Stat§115.55)An imminent threat to public health and safety(1TPHS)must be upgraded,replaced,or its use discontinued withinin tan ten months of receipt of this rrotice of within a shorter period if required by local ordinance.ff the system is failing to protect ground water,the system must be upgrad&A replaced,or its use discontinued within the time required by Axel ordinance.If an existing system it not I dsc as defined to theaw,and has at feast twc feet of design soil separation,then the system need not be upgraded,repaired,replaced,or its use dhscontlnued,notwtthstarhding any ioca!ordinance that is More stnct This provision does not apply to systems in shoreland areas, WW#wd Protection Areas,or those used in connection with food,beverage,and lodging establishments as defined in law. www.pca.state.mn.us - 651.296.6300 . 800-657-3864 TTY 651.282-5332 or 800-657.3864 • Available in alternative formats wq-wwists4-31 . 1124112 Paye 3 of 3 Jan 28 2016 07:04PM HP FaxRusty Olson 7634988290 page 5 Low of Soil Borings License 9810 Location or Project: 2575 Thoroughbred Lane Boringa made by: Rusty Olson's Soil and Perc testing 1127/2016 Classification System: AASHO : USDS-USDS-SCS X ; Unified :Other Auger used(check two):Hand X,`,or Power_,Flight,Bucket or Probe X [28-32 oring Number_i_Surface elevation_100.5_ Mottled Soil at 1.8 feet -18" Fill in original soils 8-28" Dark brown loam 10yr3/2 H2O present at X� Brown loam 10yr4/3 32-40 Brown clay loam 10yr5/4 40"-48"Rusty brown clay loam 10yr5/6 Boring Number-2_Surface elevation_100.0_ Mottled Soil at 1.8 feet 0-14"Dark brown loam 10yr'3/2 in original soils 14"-22"Brown loam 10yr413 H2O present at 22"-30"Rusty brown clay loam 10yr5/4 TBM:Top of lift station manhole cover Elv.-100.0 assumed Bottom of rock bed Elv.-101.0 Original soil under the rockbed Elv.- 100.0 There is 1.0 feet of sand under the rockbed Jan 28 2016 07:04PM HP FaxRusty Olson 7634988290 page 6 a IV T 8 Asch A Oeck A 8 --r MIA 4S I ' 9 d' 10'a c � p well 2/25/02 Water/Wastewater-ISTS4.31 Compliance Inspection Form for Existing Individual Sewage Treatment Systems Minnesota Pollution IMP Control Agency Completion of this form fulfills the minimal requirements of Minn. Stat.§ 115.55(2001)and Minnesota R. ch. 7080(1999). Please refer to local ordinances for other requirements or information, especially for compliance requirements for bedroom additions. General: Date of Inspection: Reason for i spection: 54 le Property Owner(s) Telephone{� �G - d�( Person requesting inspection i+1 Telephone( ) Site Address 5 &4 o + A ek\% City (�r�':'t%rrrL�' Zip Code Fire No./ Parcel No. County AI,¢1n)/d Township Legal Description ,t Local Regulatory Authorityd'a ry d+ A-z-o'-Vo Date system constructed 4 `7/�& System in Shoreland Area: yes System in Wellhead Protection Area: yes System serving a MDH licensed facility: yes a Local Permit# (if any) Systems built prior to April 1, 1996 and not located in Systems located in Shoreland or Wellhead Protection Shoreland or Wellhead Protection Area or Serving a Food, Areas or Serving a Food, Beverage or Lodging Beverage or Lodging Establishment Establishme Built after March 31 1996 Is the system an imminent threat to public health or Is the system an imminent threat to public health safety? (a yes answer is an ITPHS system) or safety? (a yes answer is an I7PHS system) -Discharge of sewage to the ground surface? YES NO -Discharge of sewage to the ground surface? YES N -Discharge of sewage to draintile or surface waters? YES NO -Discharge of sewage to draintile or surface waters?YES ► -Sewage backup into dwelling? YES NO -Sewage backup into dwelling? YES(V -Situation with the potential to immediately and -Situation with the potential to immediately and adversely impact or threaten public health or adversely impact or threaten public health or safety? YES NO safety? YES CCO) Is the system failing? (a yes answer is a failing system) Is the system failing? (a yes answer is a failing system) -Less than TWO feet of vertical separation between -Less than THREE feet of vertical separation between system bottom and saturated soil or bedrock? YES NO system bottom and saturated soil or bedrock? YES -A seepage pit, cesspool, drywell, or leaching pit? YES NO -A seepage pit,cesspool, drywell, or leaching pit? YES O Is the system non-compliant? Is the system non-compliant? - Is the system regulated under a monitoring plan or - Is the system regulated under a monitoring platy°w operating permit? (if no, go to page 2) YES NO operating permit? (if no, go to page 2) YES rN6, If yes, If yes, - Has the required monitoring taken place? YES NO - Has the required monitoring taken place? YES NO (If no, the system is non-complying) (If no, the system is non-complying) - Does the monitoring indicate that the system meets - Does the monitoring indicate that the system meets performance expectations? . YES NO performance expectations? YES NO (If no, the system is non-complying) (If no, the system is non-complying) Page 1 of 2 wq-wwists4.31 Property Owner(s) Fre No./ Parcel No. ..........................................................................._...............................-........................._............................................................................................................................ �s`Item Comic&" (Ple g6cribe rime SAeffltom Q -and attach site sketch showing system location): What methods were used to make the determinations for the compliance inspection?(Note.No standard protocol exists The following list is not exhaustive,or in sequential order nor indicates which combinations may necessary to make a determination) W �ght n s) Hydraulic Functioningrtical Separation Distance L; rT Rttom ❑ Searched for surface outlet ❑ Conducted soil borings .X ❑ Observed low liquid level �(❑ Performed hydraulic test Depth to limiting layer_� + ❑ Examined const.records ' t] Searched for seeping in yard X Depth to system bottom ❑ Examined empty(pumped)tank ❑ Checked for back-up in home ❑ Examined records ❑ Probed outside tank for"black soil" ❑ Excessive ponding in soil system/D-boxes ❑ LGU Limiting Layer Verification ❑ Pressu cuum check ,�,,�j Owner ony YN-5 C3 Other C3 Other/ "' �� ❑ Examined for surging in to k ❑ "Black soil"above soil system ❑ Other Status of the system Based on the compliance criteria,the system status is: (check one) ❑ failing (to protect groundwater) ❑ an imminent threat e-heai r safety(ITPHS), ❑ non-compliant(monitoring issue) [Aompliant(none of the 3 previous condins). Therefore, is document is a:A Certificate of Compliance ❑ Notice of Noncompliance Is this system an njection Well? ❑ yes Im no Certification I hereby certify as a state of Minnesota licensed Inspector and/or Designer I or Qualified Employee Inspector and/or Qualified Employee Designer I that I conducted an investigation that accurately determined the compliance status of this system and that my recorded observations are accurate as of this date. No determination of future hydraulic performance has been nor can be made due to unknown conditions during system construction,abuse of the system,inadequate maintenance,or future water usage. Inspector's name(print) /,1_A A. Phone 'Zf License and/ egistration Number '45:'/� Address Employed by 44 Zt Address Signature _ Date UDArade Reguirements [derived from Minnesota statutes,§115.55) An ITPHS must be upgraded,replaced,or/is use discontinued within ten months of receipt of this notice or within a shorter period/f required by local ordinance. If the system fails to prov/de sufc%nt groundwater proton, then the system must be upgraded, t'�replaced,or its use discontinued within the time required by rule or the local ordinance. If an existing system is not failing as defined in �aw, and has at least two feet of design loll separation, then the system need not be upgraded, repaired,replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This does not appty to systems in shoreland areas, wellhead protection areas, or those used in connection with food, beverage,and lodging estatrlishments as defined in law. Suggested Attachments 1) Site sketch could also include:well,well setback to system,dwelling or other buildings,tank(s),reserved soil treatment area, surface water and soil boring locations. Include as-built drawing if available. 2) Soil boring logs,showing each horizon. Indicate the texture,color, redoximorphic features depth to bedrock,standing water and whether the material is fill. 3) A list of any and all requirements of the local ordinance that are different from the state requirements referred to on this form. 4) A homeowner survey of system performance, signed by the homeowner as being factual. 5) Monitoring data as appropriate. Page 2 of 2 ♦ y SEPTIC SYSTEM INVENTORY Site Address: 2575 Thoroughbred La PID 04-117-23-11-0021 Owner Name: Steven & Stacy Sapletal Owner Address: 2575 Thoroughbred La Long Lake MN 55356- BuildingTvpe: residence Installer: Clover Hill Co. Date of Permit: 7/24/96 System Tvpe: mound BR's Designed for 5 In Musa?: No Shoreland?: SEPTIC TANKS: Material: precast concrete Capacity: 1300, 1300, 1300 Tank Filter: DRAINFIELD: Treatment Area: 100"40 Soil Boring: yes DF Ht above Wt: 3 WELL DATA Setbacks -Well Tanks: Well DF: Report In File: Depth: 277 INSPECTION RECORDS PUMPOUT RECORDS Date Notes Date GallonsOfLiquid 9/1/2005 Okay 7/8/2014 2700' 10/3/2003 no surfacing,need insp.Cap on 1st tank 7/20/2011 2600] 9/20/2001 no surfacing,put cap in insp. Pipe 8/8/2008 4/7/1999 no surfacing-pump tanks 7/14/2005 2500; 6/27/1997 installation 8/16/2002 2000, 9/30/19991 2000';, t In 0 N Li 8 Porch A OecK � B 7, MH �6 1 9a, T M 4i8� a 6 „---- 3 MH loa' it6 � C � We-lt aye jO 6 � O 0 P O O CITY of ORONO ,"�► �� Municipal Offices Street Address: Mailing Address: 2750 Kelley Parkway P.O. Box 66 _ Orono, MN 55356 Crystal Bay, MN 55323.0066 Owner: � �e� E�+n ' Address: 2575 Thoroughbred Ln. Permit Vs: 8188 Dates: 7/24/96 Contractors: Clover Hill Co. (This is [u] an existing system [ ] new construction) . YSTEM COM.✓lPL``IANCE (1-3) : 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [X] or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) TANK CONDITION (5-9) : 6 � Pumpout not needed at this time. /6,[J Solids accumulation in tanks indicates they should be pumped out this year. System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ or are not [ ] water tight or the condition is [ ] unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) n INFIELD CONDITION (11-14) : 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low COMMENTS: Date of I p ction --8`@­rfc System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone(612)249-4600 • Fax(612)249-4616 e O 0 CITY of ORONO VA, `"' l4 Municipal Offices s `y Street Address: Mailing Address: 9$EggOg' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323.0066 Owner: Address: 2575 Thoroughbred In. Permit #'s: 8188 Dates: 7/24/96 Contractors: Clover Hill Co. (This is [ ] an existing system [ new construction) . SYSTEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level 4.k has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision.) K CONDITION (5-9) : 5 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ were or [ ] were not confirmed to be watertight by the licensed pumping contractor. If he tanks were not confirmed to be watertight, this classification is subject to revision.) INFIELD CONDITION (11-14) : 11 (ly Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low COMMENTS: Date of Inspec ion Sep System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 o � o CITY of ORONO S ��,$" ° ` �+ ;�� ` �, Municipal Offices Street Address: Mailing Address: \9$ESDI g'O %' 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Current Owner of Address ,2.5 75- City City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31,2007 December 31,2010 Other Septic Tank(s)Pump out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on The tank(s) should be cleaned through the manhole and not through the inspection pipes,this allows for proper cleaning. Comments: tc)A-e < �- Inspector: Date of Inspection Telephone(952)249-4600 - Fax(952)249-4616 www.chorono.mn.us 0*�. ._ - 0 a CITY of ORONO ti , tiH Municipal Offices I Street Address: Mailing Address: '9ltyH04' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 ) Crystal Bay,l MN 55323.0066 To Current Owner: Address: S 7� �`� 6 r 0 w f City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. YSTEM CONFORMITY (1-3). 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): Tank inspection indicates: 66Pumpout not needed at this time. Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped 4d-% ~6.1-. ). Make sure septic tanks are pumped through manhole and not through white inspection wipes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic system. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. D INFIELD CONDI ON 8-10 : Q8j Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: o„r. \00)0 off, R M s �:, l- Sup.. r Date of Inspection Matt Bolterman- Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy ofthe system under current conditions based on the available information. Telephone(952)2494600 - Fax(952)249-4616 www_ci_nrnnn_mn_uc 0 0 CITY of ORONO Municipal Offices Street Address: Mailing Address: �Eg1;I0 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: Ant� 0�w �''� C,1 �" Address: �S 7S �a�a v 1,�� L ' e +� Cite Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards ofthe cunent Orono Municipal Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. T.kNK CONDITION(5-10): 5 ink inspection indicates: ( � Pumpout not needed at this time. p,l 6 Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped C1-30 -91 1, 7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years,they should be pumped out now. 10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(11-14). \\ 11 Drainfreld is dry,no surfacing evident 12 Some evidence of surfacing,not critical yet 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. 1.1 Dminfield extent and condition unknown. ` COUNTS: to, ook� oldoP q-�'� -D Date of on 6 ec Ins + p Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information.