System Status
System status on date(mmiddlyyyy): 5/20/2013
® Compliant—Certificate of Compliance ❑ Noncompliant—Notice of Noncompliance
(Valid for 3 years from report date, unless shorter time (See Upgrade Requirements on page 3)
frame outlined in Local Ordinance.)
Reason(s)for noncompliance(check all applicable)
❑ Impact on Public Health (Compliance Component #1)—Imminent threat to public health and safety
❑Other Compliance Conditions(Compliance Component#3)—Imminent threat to public health and safety
❑Tank Integrity(Compliance Component #2)—Failing to protect groundwater
❑Other Compliance Conditions(Compliance Component#3)—Failing to protect groundwater
❑ Soil Separation(Compliance Component #4)—Failing to protect groundwater
❑ Operating permittmonitoring plan requirements(Compliance Component #5)—Noncompliant
Property Information Parcel ID#or Sec/Twp/Range: 04-117-23-11-0018
Property address: 2425 Throughbred Lane, Orono,MN Reason for inspection: Property Transfer _
Property owner: Paul Dejute Owner's phone: 952-404-1144
or
Owner's representative: Representative phone:
Local regulatory authority: City of Orono Regulatory authority phone. 952-249-4600
2-1300 gallon septic tanks,1-1300 gallon lift station and 680 square feet of mound rockbed. per city
Nef system description: records
Comments or recommendations:
,)tThe edsting iron filter must be plumbed out of the septic system.
Certification
f hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No
determination of future system performance has been nor can be made due to unknown conditions during system construction,
possible abuse of the system,inadequate maintenance, or future water usage.
inspector name: Joseph J Olson Certification number: 1255
Business name: Rust on's Soil &Perc.Testing License number 810
Inspector signature- Phone number: 763-498-8779
Necessary or Locally Required Attachments
®Soil boring logs ® System/As-built drawing ❑ Forms per local ordinance
❑Other information (fist):
www.pca.state.mn.us • 651-296-6300 • 800-657-3864 TTY 651.282-5332 or 800-657-3864 • Available in alternative formats
wq-wwists4-31 • 1124112 Page f of 3
May 22 13 08:55a Joseph Olson 763-498-8290 p.3
Property address: 2425 Throughbred Lane Orono MN Inspector initials/Date: J. 0.05120M3
1. Impact on Public Health—Compliance component#1 of 5
Compliance criteria: Verification method(s):
System discharge sewage to the j ❑Yes ®No ® Searched for surface outlet
round surface. ® Searched for seeping in yard/backup in home
System discharge sewage to drain file [:]Yes ®No ❑ Excessive ponding in soil system/D-boxes
or surface waters. ❑ Homeowner testimony(see Commerns(F.xp/anaum)
❑ "Black soil'above soil dispersal system
System cause sewage backup into [--]Yes ®No ❑ System requires'emergency'pumping
dwelling or establishment
❑ Performed dye test
Any"yes"answer above indicates the system is
an Imminent Threat to Public Health and Safety. ❑ Unable to verify(see CommentslExplanaSon)
❑ Other methods not listed(See CommentslExplanation)
Com mentslExplanation:
2. Tank Integrity—Compliance component#2 of 5
Compliance criteria: Verification method(s):
System consists of a seepage pit, ❑Yes ®No ® Probed tank(s)bottom
cesspool,drywell,or leaching pit. ® Examined construction records
Seepage pits rneeft 7080.2550 may be ❑ Examined Tank Integrity Form(Attach)
cornpAW if Mowed in local ordinance.
❑ Observed liquid level below operating depth
Sewage tank(s)leak below their El Yes 0 No
designed operating depth. ❑ Examined empty(pumped)tanks(s)
If yes,which sewage tank(s)leaks: ❑ Probed outside tank(s)for"black soir
Any`Yes"answer above indicates the ❑ Unable to verify(Sea CommentwExplanation)
system is Failing to Protect Groundwater. ❑Other methods not listed(See Commentv&p/anation)
Comments/Explanation:
3. Other Compliance Conditions—Compliance component#3 of 5
a. Maintenance hole covers are damaged,cracked,unsecured,or appear to structurally unsound. ❑Yes' ®No ❑Unknown
b. Other issues(electrical hazards etc.)to immediately and adversely impact public health or safety. ❑Yes' ®No ❑Unknown
'System is an imminent threat to public health and safety
Explain:
c. System is nonprotective of ground water for other conditions as determined by inspector ❑Yes` ®No
"System is failing to protect groundwater
Explain:
www.pca.state.mn.us • 651-296-6340 • a00.657-3864 TTY 651-282-5332 or 800-657.3864 Availabte in altemative formats
wq-ww1sts4-31 • 1124112 Page 2 of 3
May 22 13 08:55a Joseph Olson 763-498-8290 p.4
Property address: 2425 Throughbred Lane Orono MN _ Inspector initials/Date: J.0.05120113
4. Sail Separation—Compliance component#4 of 5
Date of installation: 9/23/96 ❑Unknown Verification method(s):
ShorelLodgiin /MVellhead protectioNFood Beverage
Lodging?
❑Yes 0 No Soil observation does not expire_Previous soil
observations by two independent parties are sufficient,
Compliance criteria: unless site conditions have been altered or local
For systems built prior to April 1, 1996,and ❑Yes ❑No requirements differ.
not located in Shoreland or Wellhead ® Conducted soil observation(s)(Attach boring logs)
Protection Area or not serving a food, ❑ Two previous verifications(Attach boring logs)
beverage or lodging establishment
❑ Not applicable(Holding tarNc(s),no drainfield)
Drainfield has at least a two-foot vertical ❑ unable to verify(See CommenwExplanation)
separation distance from periodically
saturated soil or bedrock. ❑ Other(See Commenwiaplana6m)
Non-performance systems built April 1, ®Yes ❑ No Comrnents/Explanation:
1996. or later or for non-performance
systems located in Shoreland or Wellhead
Protection Areas or serving a food,
beverage,orlodgrngestablishment
Drainfield has a three-foot vertical
separation distance from periodically
saturated soil or bedrock.*
'Experimental" "Other',or Performance" ❑Yes ❑No Indicate depths of elevations
Systems built under pre-2008 Rules,Type 1V
or V systems built under 2008 Rules(7080. A. Bottom of distribution media 1017.3
2350 or 7080.2400 (Advanced Inspector
License required) B. Periodically saturated soiUbedrodc j 1014
Drainfield meets the designed vertical 1
separation distance from periodically J C. S rasion 3.2
saturated soil or bedrock.
D. Required compliance separation" 2.6
Any"no"answer above indicates the system is 'May be reduced up to 15 percent if allowed by Local
Failing to Protect Groundwater. Ordinance.
S. Operating Permit and Nitrogen BMP*—Compliance component#5 of 5 ® Not applicable
Is the system operated under an Operating Permit? ❑Yes ❑ No If"yes",A below is required
Is the system required to employ a Nitrogen BMP? ❑Yes ❑No If"yes",B below is required
BM!}Best Management Practice(s)specified in the system design
If the answer to both questions is"no"N this section does not need to be completed.
Compliance criteria _
a. Operating Permit number.
No
Have the Operating Permit requirements been met? El Yes El
b. is the required nitrogen BMP in place and-Properly functioning? ❑Yes_Q No
Any"no"answer indicates Noncompliance.
Upgrade Requirements(Minn.Stat.§115.55)An imminent threat to public health and safety(l7PHS)must be upgraded,replaced,orits use
discontinued wrlhin ten months of receipt of this notice or within a shorter period if required by local ordinance.if the system is failing to protect
ground water,the system must be upgraded,replaced,Grits use discontinued within the time required by local ordinance.If an existing system
is not failing as defined in law,and has at least two feet of design sod separation,than the system need not be upgraded,repaired,replaced,or
its use discontinued,nolwithstandrrg any local ordinance that is more strict This provision does not apply to systems in shoreland areas,
Wellhead Protection Areas,or those used in connection with food,beverage,and lodging establishments as defined in law.
www.pca.state.mn.us - 651-296-6300 • 1300-657-3864 TTY 651-282-5332 or 80o-657-3864 . Available in alternative formats
wq-wwists4-31 • 11241 f2 Page 3 of 3
May 2213 08:55a Joseph Olson 763-498-8290 p.5
Loots of Soil Borings
License#810
Location or Project:2425 Thoroughbred Lane
Borings made by: Rusty Olson's Soil and Perc testing 5/20/2013
Classification System: AASHO USDS•USDS-SCS X Unified ; Other
Auger.used(check two):Hand or Power, Flight, Bucket or Probe_X—
Boring Number_1_Surface elevation_1017.4 Mottled Soil at_X_feet
0"-18"Dark brown loam 10yr312 H2O present at—X—
IV-24"Brown loam 10yr414
Boring Number-2—Surface elevation_1015.8, Mottled Soil at 1.7 feet
0-6"Dark brown loam 10yr3/2 H2O present at—X-
6"-12" Brown loam 10yr414
12"-20"Brown sandy loam 10y5/4
20"-30"Rusty brown loam 10y514
TBM:Top of block Elv.-1027.4 assumed
Original soil underthe rockbed Elv.- 1015.8
Bottom of rock bed Elv.-1017.3
There is 1.5 feet of sand under the rockbed
May 22 13 08:55a Joseph Olson 763-498-8290 p.6
• ��
71 o kb(j
-A 13
T; m 4 4410CO- Lf
T � q,9' -
oo� sqd 06
-F3 M f g �`
,
CITYof ORONO
,�►� t§J'J; Municipal Offices
Street Address: Mailing Address:
2750 Kelley Parkway P.O. Box 66
\9xESxDg Orono, MN 55356 Crystal Bay, MN 55323.0066
To: The Current Owner of Address 2 -)g .s-- %A c) v�%`, '/r,'{� ✓
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes
No
If yes,please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identified as Non-Compliant
Yes 7z
No
If yes, system must be brought into compliance by:
December 31,2007
December 31,2010
Other
_Septic_Tank(s) Pump out Needed - - - -
Yes
No
The City recommends the septic tank(s) and/or lift tank be serviced and pumped
out every three years. City records indicate the tank(s)were last pumped out on
6r� `�� The tank(s) should be cleaned through the manhole and
not through the inspection pipes,this allows for proper cleaning.
Comments:
Inspector:_ W Date of Inspection1
Telephone(952)249-4600 • Fax(952)249-4616
www.cLorono.mn.us
o
o ,_
: - CITY of ORONO
",�► �l�r Municipal Offices
t a Street Address: Mailing Address:
2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, W 55323-0066
Owl
To
. A14 01 7�o�v�51, b�cd
+C�trem# ttrer: ddress:
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
TEM CONFORMITY (1-3):
1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not mat all the location,design and construction standards of the current Orono Municipal
Code but does mat the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7):
Tank inspection indicates:
Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped C-)-03 ).
Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the
proper cleaning. Keep water softner and iron filter discharge out of septiLsyMem.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
D*ARIEELD CONDITION(8-10):
8 13rainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
CONNffi'NTS:
�o -
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised Wal this report Ones not;guaraetee
or certify dug w existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions basad an the available
Telephone(952)24946M • Fax(952)249-4616
www cLorono amus
CiTyof ORONO
�26ti Municipal Offices
F Street Address:
���g'�Y Mailing Address:
2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: 4 U\ e .� a4
Address: 'fk0 r-U vy��,c J
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards ofthe current Orono Municipal
Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting$oil characteristics.
TANK CONDITION 0-10):
Tank inspection indicates:
Pumpout not needed at this time.
Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped
7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible.
3 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks
have not been pumped out within the last three years,they should be pumped out now.
10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped
out within the list three years,they should be pumped out now.
DRAINFIELD CONDITION 11-14
I 1 Drainfield is dry,no surfacing evident
Some evidence of surfacing,not critical yet
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be
completed within 90 days.
14 Drainfield extent and condition unknown.
CON2,4ENTS: S-�/Str_
OA
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
O
O : O
CITY of ORONO
Municipal Offices
Street Address: Mailing Address:
` HQ¢' 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: J;AaAddress: 2425 Thoroughbred Ln.
Permit Vs: 9510 Dates: 10/13/97 Contractors: Clover Hill Co.
(This is [x] an existing system [ ] new construction) .
STEM COMPLIANCE (1-3) : 1
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level is [3] or is not [ ] identified under this septic system. If the
saturated soil level is not identified, this classification is subject to revision.)
NK CONDITION (5-9) : 5
5 Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are [)�L or are not [ ] water tight or the condition is [ ] unknown. If the tanks
are not confirmed to be watertight, this classification is subject to revision.)
2JSEINFIELD CONDITION (11-14) : 11
[lP Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low
COMMENTS:
Date of InspectionA—SzeiprfAcSy=,tem- Inspec or
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone(612)249-4600 • Fax(612)249-4616