HomeMy WebLinkAbout2000-P02500 - addn/remodel/repair • PERMIT
CITY OF ORONO Permit Number:
2750 Kelley Parkway- PO Box 66 P02522
Crystal Bay, Minnesota 55323 Permit Type: Addition/Remodel/Repair
(612) 249-4600 Date Issued: 6/20/00
SITE ADDRESS: 1065 Tamarack Dr
LONG LAKE,MN 55356
PID: 26-118-23-31-0009
DESCRIPTION: UBC Occupancy R3
Proposed Use: Construction Type VN
Permit Class: Building Census Code 434
Permit Type: Addition/Remodel/Repair Permit Sub-type(s): Single Family
DETAILS:
Approved per resolution#:
Separate permits required: Eiectricai(state)
NOTICES/REMARKS:
C14ANC-E GARAGE fNT0I MNG SPACE
FEE SUMMARY: Permit Fee: $ 349.25 Valuation: $ 21,436.00
Plan Review Fee: $ 226.98
State Surcharge Fee: $ 10.75
TOTAL FEE: $ 586.98
APPLICANT: JOHN GRAHAM OWNER: T H GRAHAM&J J GRAHAM
7239 LOGAN Ave S 3965 BAYSIDE RD
RICHFIELD,MN 55423 LONG LAKE MN 55356
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED
AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND
STATE OF MINNESOTA BUILDING CODE REQUIREMENTS.
47 ANT PERNIITEE SIGNTrUfff- UED BY SIGNATURE
Copies:City,Applicant,Assessor,Finance Page 1
Total Fee: $ I Date Received:
Entered By: .fgA Permit#: O
CITY OF ORONO - BUILDING PERMIT APPLICATION
All information must be submitted in full before plan review will be started.
(please print all information)
--------------------------------------------------------------------------------------------------------------------
THE APPLICANT IS: (circle one) OWNER CONTRACTOR
JOB SITE ADDRESS: iat _,N 2ft CK ZIP: SS3`J CO
NAME OF OWNER: to f JEu"r-4 r 6 QkPHONE: (home Y73-,35-)?
(work) F y 7 b-5351
MAILING ADDRESS: /_t r" RAA K CITY: &204 o ZIP: 3 S3 S
CONTRACTOR: 41fIF 0WAIC-Of PHONE: 86(o- g1o31
CONTACT PERSON: JoµN Ra 64 Ft#K MOBILE/PAGER: &51 5`1a -34911
MAILING ADDRESS: 7 o?,34 6064-J AV'`.S. CITY: ?�-r( b ZIP: 6SVa3
STATE LICENSE: # "A t L D -Fo R
ARCHITECT/ENGINEER: /Vov-_ - j STS)J(o STkOM14QEPHONE:
MAILING ADDRESS: CITY: ZIP:
NA IE: REGISTRATION#
TYPE OF WORK: New Addition Accessory Structure
Move Remodel/Alteration _ Land Alteration
PROPOSED WORK(describe in detail): S Ft-E A 77-WCk-E iS
STORIES: SQ. FEET OF EACH FLOOR:
NO. OF BEDROOMS: GARAGE STALLS: ATT. DET.
ESTIMATED CONSTRUCTION VALUATION (excluding land): $ � 2�1
I hereby apply for a building permit and I acknowledge that the information above is complete and
accurate; that the work will be in conformance with the ordinances and codes of the City and with
the State Building Code; that I understand this is not a permit and work is not to start without a
permit; and that the work will be in accordance ith the approved plan.
APPLICANT'S SIGNATURE: DATE: 66 -OD -00
NOTE! Parade of Homes events require separate permit approval by Police Department and
City Council 60 days prior to the event. Non permitted events will not be allowed.
9
See.13.04 RIGHTS OF SUBJECTS OF DATA
Subd. 1. Type of data. The rights of individual on whom the data is stored or to be stored shall be as set forth in this section.
Subd.2. Information required to be given individual. An individual asked to supply private or confidential data concerning himself shall
be informed of: (a)the purpose and intended use of the requested data within the collecting state agency, political subdivision, or statewide system; (b)
whether he may refuse or is legally required to supply the requested data; (c)any known consequence arising from his supplying or refusing to supply
private or confidential data;and(d)the identity of other persons or entities authorized by state or federal law to receive the data. This requirement shall
not apply when an individual is asked to supply investigative data, pursuant to section 13.82, subdivision 5,to a law enforcement officer.
The commissioner of revenue may lace the notice required under this subdivision in the individual income tax or property tax refund instruction
instead of on those forms.
Subd.3. Access to data by individual. Upon request to a responsible authority, an individual shall be informed whether he is the subject o
stored data on individuals,and whether it is classified as public,private or confidential. Upon his further request, an individual who is the subject of store
private or public data on individuals shall be shown the data without any charge to him and, if he desires, shall be informed of the content and meanin
of that data. After an individual has been shown the private data and informed of its meaning, the data need not be disclosed to him for six month
thereafter unless a dispute or action pursuant to this section is pending or additional data on the individual has been collected or created. The responsible
authority shall provide copies of the private or public data upon request by the individual subject of the data. The responsible authority may require the
requesting person to pay the actual costs of making, certifying,and compiling the copies.
The responsible authority shall comply immediately, if possible,with any request made pursuant to this subdivision, or within five days of the
date of the request,excluding Saturdays,Sundays and legal holidays, if immediate compliance is not possible. If he cannot comply with the request within
that time,he shall so inform the individual, and may have an additional five days within which to comply with the request, excluding Saturdays,Sunday
and legal holidays.
Subd.4. Procedure when data is not accurate or complete. An individual may contest the accuracy or completeness of public or private data
concerning himself. To exercise this right, an individual shall notify in writing the responsible authority describing the nature of the disagreement. The
responsible authority shall within 30 days either: (a)correct the data found to be inaccurate or incomplete and attempt to notify past recipients of inaccurate
or incomplete data,including recipients named by the individual;or(b)notify the individual that he believes the data to be correct. Data in dispute sha 1
be disclosed only if the individual's statement of disagreement is included with the disclosed data.
The determination of the responsible authority may be appealed pursuant to the provisions of the administrative procedure act relating to contestei
cases.
DATA PRIVACY ADVISORY
In accordance with M.S. 13.04, Subd. 2, "Rights of subjects of data", we would like to inform you that your reque t
for a permit or license from the City of Orono or any of its departments may require you to furnish certain private r
confidential information.
You are notified that:
1. The information you furnish will be used to determine your qualification for the permit or license requeste .
2. You may refuse to supply data, but refusal may require that the City deny the permit or license.
3. The information may be shared with other local, state or federal agencies to the extent necessary to proce s
the permit or license.
4. If your requested permit or license requires Council action to approve, some information may become publ' .
5. You have certain rights under M.S. 13.04 (available upon request) to review private data on yourself.
6. Your full name is required to process this application or permit.
First Middle Last
'?a 35 Lei Co v r
Ad ess
1116 /mit/ SY�`a 3 c t�s� - S4a • 30
City State Zip Phone
I understand my rights as stated above.
Signature
10
• CHECK OFF LIST FOR ISSUANCE OF PERMITS
FOR OFFICE USE ONLY
ADDRESSORLEGAL: ►Olds Actroc.tc
PID:
DESCRIPTION OF WORK: 14rmc-q-ed GA-,rvFr-c?- av 4n. C���/�• ze -�-�'
ZONING REVIEW BY: N10+ DATE APPROVED:
BUILDING REVIEW BY: DATE APPROVED: 6-/3-o 0
FEES TO BE CHARGED: Misc. Fees Calculated By:
PERMIT Yes ✓ No
PLAN REVIEW Yes v No SEWER CONNECTION
STATE SURCHARGE Yes ✓ No WATERCONNECTION
INVESTIGATION FEE Yes No ✓- PARK FEE
SAC Yes No c/ SITEINSPECTION
Number of SAC-Units OTHER (specify)
ZONING CHECK LIST Zoning District: /yU C 11PiW6 e
Fire Department: Post Office: School District:
Lot Area: Sq.ft. Acres Width Depth
Survey Submitted: Yes No Date of Survey:
Proposed Setbacks:
Front(Lake): Right Side:
Rear(Street): Left Side:
Adjacent Structures: W tland:
Building Height: Def. Hgt. Pe -Hgt.
Lot Coverage:
Grading: Staff Approval Date: Council Approval Date:
Septic: Staff Approval Date: B :
Zoning File: # Resolution: # Resolution Date:
Shoreland District:
Avg. Setback: Bluff Setback: Lot Coverage:
Existing Proposed
Hardcover: 0-75'
75-250'
250-500'
500-1000'
Hardcover Variance Required: Yes No Date of Council Approval:
REMARKS(in house):
7
BUELDING REVIEW CHECK LIST
UBC: R-3 CONSTRUCTION TYPE: VN
Sq Footage $Per Sq Ftg
Basement x
1st Floor a =
2nd Floor x =
Garage x =
ZZ x 22a YS x ` q.Z,9 = 2 1, q3(o
TOTAL
Estimated Construction Value: $_ Z I A'4316 o%
Inspections Required: Work Requiring Separate Permits:
Site Plumbing Fire
Hardcover Removal Mechanical Water Connection
Footing Septic Sewer Connection
__)L Framing Fireplace Lawn Irrigation
►� Insulation (Masonry) Other
N Wall Board (Mfg.) Well(State Permit)
�Final Grading/Filling G Electrical(State Permit)
Other
REIN ARKS(IN HOUSE):
REVIEW BY OTHERS: DATE:
Access: Existing New
Access Approval: Date By:
REMARKS (TO BE NOTED ON PERMIT:
8
t
1065 Tamarack ORONO
copy
Proposed garage to living space / storage remodel
Description
• Install 2x4 treated sleepers over existing slab
• Install 2"Dow board (R-10) between sleepers
• Install 4mil vapor barrier
• Install 3/4" T&G OSB decking
• Remove existing garage door
• Install 2x6 framed wall l 6oc in place of garage door
•
Install 1/2" cdx plywood on new ext.wall
• Install R-19 Fiberglass in new ext. wall
• Install 4 mil vapor barrier on new ext. wall
•
Install 1/2" gymsum board on new ext. wall
• Install double hung windows w/wood grills
(1) RO W: 2' 6" x RO H: 6' 8 5/8" in back wall
(1) RO W: 4' 11 '/2"x RO H: 6' 8 5/8" in new
framed ext. wall
• Install 2 DR swing patio door w/wood grills, Hinged on center astragal, Left
operating/Right fixed as viewed from exterior
(1) RO W: 6' x RO H 6" 8 5/8" in new framed
ext.wall
• Install brick between door unit and window unit of new ext. wall
• Install electrical outlets to code
• Install (9) light fixtures (2 S3)
• Install (3) new ceiling supplies and (1)wall return
• Install 2x4 framed int.wall between stairs to water heater room
• Install 1/2"' gymsum on new int. wall
• Install 2'8" 6 panel int. door to water heater room stair
• Install 3' 6 panel int door to new living/ storage room
• Install 2x4 framed walls to make new electrical/phone/cable TV closet
• Install ''/Z" gymsum on new closet walls
• Install 2'8" 6 panel int. door to above closet
CITY OF ORONO
BUILDINGE'ER T PLAN REVIEW
INSPECTOR �'
SPECIAL NOTE DATE &-► 3 -11 PERMIT NO.
SEE ATTACKED SHEET �❑ A¢ POVcD AS SUBN11TTED
l=�rSC; 'D Y,IIT'H OO .RECTIO%IS AS NOTED
; FOR R D NOT MOR LVED---CG^r SECT&RES11SMI!T
CODE REQU1Rtwvlc.NTS 7tese comments ara'or p,— iG10rm9'i r. A!I Y.'ut{$h81i 5e Cona
I(1 tall CGlT1DII3.iCd 1'itl 2h 'd7;'.t ;hid CUIICj;r.c and zoning c.�a-
Requiromarta InCIU',:d'!}::�?fi S ili S�cCiflGu'�,i need in*,h;S.6V12t14
KEEP THIS PLAN SLT ON SITE AT ALL TINIES
• max,a���
Front View ' Beck View
i
Front View sick View
00
CO PGFTV,�
Front View Bock View
•
W
ofi i —
OUND a
GRAHAM
HVAC LOAD ANALYSIS
for
John Graham
1065 Tamarack Dr.
Orono, MN
Lop
HVANiA�I'i` At�
Prepared By:
Doug Bjork
Ditter Inc.,Cooling and Heating
820 Tower Drive
Medina,MN. 55340
(612)478-9558
RHVAC=Residentlal&Light Commercial HVAC Loads Program Elite 5oftwars Development,Inc.
i Ditter,Inc. Graham
Hamel,MN 55340-9691 rage 2
Total Building Summary Loads
Component---- ----- --- ----- ---- ------------- ---- Area -- Sen. Lat. Sen. Total
Description_ _ _ Quan Loss Gain Gain Gain
3A Window Double Pane Clear Glass Wood Frame 408 20,682 0 20,846 20,846
8M Glass Door Double Clear Glass Wood Frame 84 4,258 0 3,990 3,990
10F Door Wood Solid Core& Metal Storm 21 618 0 159 159
12D Wall R-11 + 1/2"Asphlt Board(R-1.3) 2,079 15,301 0 3,925 3,925
16G Ceiling R-30 Insulation 2,298 6,977 0 3,337 3,337
22A Slab on Grade No Edge Insulation _ 288 21,462 0 0 0
Subtotals for structure: 5,178 69,298 0 32,257 32,257
Active People: 4 0 920 1,200 2,120
Inactive People: 0 0 0 0 0
Appliances: 0 0 0 1,600 1,600
Lighting: 0 0 0
Ductwork: 0 0 0 0 0
Infiltration: Winter CFM: 206.9, Summer CFM: 103.4 513 20,311 2,456 2,208 4,664
Ventilation: Winter CFM: 50.0, Summer CFM: 25.0 0 4,909 594 534 1,127
Sensible Gain Total: - 37,799-
Temperature Swing Multiplier: X1.00
Building Load Totals: --- - --- - --- ------------- - - 94,518 3,970 37,799 41,768
Check Figures
Total Building Supply CFM: 1746 CFM per square foot: 0.76
Square feet of room area: 2,298 Square feet per ton: 547.163
Building Loads
Total heating required with outside air: 94,518 Btuh 94.518 MBH
Total sensible gain: 37,799 Btuh 90 %
Total latent gain: 3,970 Btuh 10 %
Total cooling required with outside air: 41,768 Btuh 3.481 Tons(based on sensible + latent)
4.200 Tons (based on 75% sensible capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
Saturday,May 27,2000
DATE yIME
CITY OF ORONO CALLED IN L11-o o
INSPECTION NTIC C SCHEDULED �-Q_
PERMIT NO. G `� � COMPLETED
ADDRESS ,�1 D
OWNER 1�f-h-SIIL � CONTR.
TELEPHONE NO. C�e /� S� 57-A 3 O 7 7
DESCRIPTION --/7 Y23 3 S l J
W 01 FOOTING 11 MECHANICAL RI 18 EXCAWGRADING/FILLING
2 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS
NSU ION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL
Z
04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION
Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS
07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT
J 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP
W 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL
= 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL
J
Q OWNERICONTRACTOR TO MEET YOU:_YES_NO
Z
MENT :
W � k V
a
J
O
a
O
W
W
W
Q
f2
Z
W
z
W
CC
d
W (�7 WORK SATISFACTORY:PROCEED El PROJECT COMPLETE
_
Cr ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY
W
D ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
0 BEFORECOVERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. F' PHOTO TAKEN
INSPECTOR WILL RETURN
CITATION ISSUED
[ISTOP ORDER POSTED.CALL INSPECTOR
❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. 249-4600
Owner/Contractor on site:
Inspector.
White Copy/Inspector's File Canary Copy/Site Notice
DATE /TIME
,�
CITY OF ORONO CALLED IN �y
'
INSPECTION NOTICE SCHEDULED
PERMIT NCOMPLETED '-� C 31->
ADDRESS /0 (0 S
OWNER CONTR.
TELEPHONE NO. Lf -23 -
DESCRIPTION
W 01 FOOTING 11 MECHANI L RI 18 EXCAV/GRADING/FILLING
W 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS
�3 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL
WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION
Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS
07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT
J 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP
W 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL
Z 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL
J
Q OWNER/CONTRACTOR TO MEET YOU:_YES_NO
Z
OC COMMENTS:
Cc
W
Q_
CC
O
O
Cz
O
W
W
cc
Q
Z
W
W
cc
j
Q 4ORK SATISFACTORY:PROCEED 17, PROJECT COMPLETE
W (❑CORRECT ORRECT WORK&PROCEED Fl ISSUE CERTIFICATE OF OCCUPANCY
O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
BEFORE COVERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. r; PHOTO TAKEN
INSPECTOR WILL RETURN
F CITATION ISSUED
❑STOP ORDER POSTED.CALL INSPECTOR
❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. 249-4600
Owner/Contractor on site:
��Inspector.T. /i i --
White Copy/Inspector's File Canary Copy/Site Notice
DATE TIME
CITY OF ORONO CALLED IN 7-27-co
INSPECTION NOTICE SCHEDULED
PERMIT NO. An-252-2- COMPLETED
ADDRESS
OWNER CONTR. Cv�►rn
TELEPHONE NO. 412 3' 35/
DESCRIPTION
LLQ 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING
LL
02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS
y
O 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL
Z 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION
Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS
07 D MO-SITE 27 SEPTIC MAINT. 21 COMPLAINT
v 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP
09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL
v 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL
Z OWN ERICONTRACTOR TO MEET YOU:_YES_NO
� COMMENTS:
QC
W
Q.
cc
J
O
cc
O
U_
W
Q
Z
W
Z
W
QC
QC /WORK SATISFACTORY:PROCEED ROJECT COMPLETE
W/ ❑CORRECT WORK&PROCEED C ISSUE CERTIFICATE OF OCCUPANCY
❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
BEFORE COVERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. C PHOTO TAKEN
INSPECTOR WILL RETURN
ElSTOP ORDER POSTED.CALL INSPECTOR F' CITATION ISSUED
❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. 249-4600
Owner/Contr t on site:
Inspector.
White Copy/inspector's File Canary Copy/Site Notice