HomeMy WebLinkAboutseptic info 06/29/2006 23:19 7634988296 RUSTVS PERC TESTING PAGE 02
� RUSTY OLSON'S SOIL AND PERC. T�STIMG
i 11481 Riverview Rd. NE � NANOVER, MN 55�41
Phone 783�98-8779 � Fax 763�98-8290
Joseph J. Olson--MPCA license #810
Randy�eyr,on
3160 Sussex Road.
Ozono, I�enne�in County
Tv whonn it may concer�,
�was contact�ed by Eric Myhran to pe�r;form a Septic certification on the property at 3160
Sussex �toad. �n the ciry of Orono. Th,e results of the Septic certification are as follows.
Soil bori�ngs on the�roperty at 3160 Sussex Road. Indicate that the Septic system does
conform�to the three�oot separation xule from the high water table. Therefoz�e the existizag trench
system as in a state of compliance to tb.e code Chapter 7080.
Soal bori�g#1 EIv.-103.� Matt,led soil was located at Elv.-97.8
Soil boriug#2 Elv.-1(?6.7 Mott�ed soi]was located at Elv.-�00.7
Crrour�d at trench#1 as at Elv.-107.0 BotCom of rock in trench#1 is at Elv.-�05.5
Ground at trench#5 is at Elv.-1U4.2 $ottor�of rock in trench#5 is at Elv.-101.8
The bottom of the rock is 2.4 feet in the ground. Mottled soils are�ocated at 5.5 feet
below grade.
This is no guarar�tee that the existing system will functio�for any tame because t�uis
inspector does not known what went into th�system�rior to or after the inspection.
If you have any questxons�lease ca11.
Sincerely,
�
Joseph J. Olson
06/29I2066 23:19 7634988290 RUSTVS PERC TESTING PAGE 03
1/29/02 Water/Wastewater-ISTS4.31
Compllance Inspectio� Fornn far Existing
Individual Sewage Treatment S�stems Mlnne�vta Pofludon
Conb�ol Agency
CanA/eNon of this form fuNPps the mdnlmal�qu/rementa o�Minn. Stat. § 115.55(2001 J and Minnesote R. ch. 7080(1999). Prease
rete�to/ocel oidinences ff�r od►er�equl�ements or infr�rma6on,aspeclaily for compliance�epuirements f�r bedmom addiKons.
w
�.116�iia l I
Dabe of Inspection: OG/28/06 REASON for inspeclJon: �rooertv Transfer
Properly Owner(s) Teleplwne ( )
Person requestinq inspectlon: Ed�M�►hran Telepha�e (612) 810-3745
S16e Address: 3150 Su�c�q$d Clty: �rono Zip Code 55356
Fire No./ Paroel No. Cau�y: H�neoln TO�wnshlp:
Lepsl Despipaon
Local Reyul�bory Authoritfl:�,y of Orono
Date sys�em oonstrvtbed: �/15102 Stirs�em in Shoreland Aroa: yes no S�sbem in Wellhead
Protection Ar+ea: yes no S�m serviny a MDH lioensdr!fadiily: yes no Loeal Perntit# (if any)�
S�rs�ems built prior tp Ap�l 1, 1996 a�d not locabed In Systems located in Shereland or Wellhead Pro�tfon
Shoneland or Wellhead Prot�ct9on Anea or Serving a Food, Areas or Serving a Food, Bev�erage or Lndging
Beverage or ladging Establlshment Establishment, or systems Buiit afber
March 31 1996
ls the srs�em an Imminrrrt tfir+e�a�t b��ublic healtl�or
�(a y�s ansr+�r�r an ITJ�Yi�S sys��m) or�af ieetv� (a yes an�ssw�r is an.I7PH5 syst�+n)
-Disd�arge of sewege to tt�e grou�d surtdoe? YES NO - Discharge of sewage to tl�e ground surtaae7 YES
-Disd�arge of sewage bo draintile or surfaae wat+ers? YES NO -Discharge of sewage to diaintile or surfaoe watet5?YES
-Sewage badaup Into dwelling� YES NO -Sewage backup InCo dwelling� YES
-Sibuation wRt�the pobe�bal tn Immedlabefy and -Sit.uatlon with the paten�l to ImrrrediaDely and
ad�,,eiy impact or threaCen public heatth or adversely Impact or threaben public health or �
safiety7 YES NO 5afety? YES N
Is fite�vsst��am failina? (a y�s answ�r ls a faI/!ng system) �tlte svstem !°alllna? (a y�s ansvr�r/s a Failing syst�mJ
-Less lt�n TVYO feet of vertial 9ep�aradon bc�ween - Less tfian THREE feet of verUtal separation between
sy�bern bottom anG saburated soil or bedrock? YES NO syst�em bottom and saturated soll or bedrock� Y
-A 5eepage pit,oesspool,drywell,or leathing plt? YES NO -A 5eepdge plt,oesspool,drywell, or leaching pit? Y
Is tlre svetem non-comnliant? ��,��y�p!�an-comMiant?
- Is tfie system regulated under a monftoring plan or - Is the system regulated under a monito�ing pla
ope�ating permit'� (�no, go to page 2) YES NO operating pertnit? ("rfno, goo to pege 2) Y NO
1!yes, If yes,
-Has the�equire� monitoring taken place? YES NO -Has the required monitoring taken place7 YES NO
(If no, fhe system is non-complying) (If no, the system is nor�-complying)
-The monitori�g indicate that the system meets -The monitoring indicate that the system meets
performance expectations? YES NO perFormance eXpectations? YE5 NO
�rr�o, the system is non-compJyingJ (l1 no, the aystem is non�anplying)
Page 1 of 2 wq-wwists4.31
06/29/2006 23:19 7634988290 RUSTYS PERC TESTING PAGE 64
Property Owner(s) Ran �4n Site Add�ess: �160 S ssen Road
Svsbem�irna�nenls(Ple�ase de�crib+e the system cnrnpov,enCs):
I n xlm
sausre�af trand�as oer citv r+eo�rd.
What mathod�were used to make the determinations br the compflanae Inspectlon� (Note:No s�indard prol�rol Qx/sti
' 71�e�ing/lsr Is not e.r/�ataGNe, rwt in s�quentia/aoier naor�ndira�es whkh canb/na�ars ere�ary ro make a determinado�hj
Watier�iaht tenk(s) Vertical Seaar�,tlon Disianc�
o Prohed tank bot6om � Searthed For surface outlet m Conduded soil borings
C] Obse►ved low liquid level ❑ Pe�fam►ed h,ydraulic test Depth to limltfng layer �.�'
� Examined mnst ne4ords � Sea�hed for seeping in yard Depth ta sys�em battom j,Qj,�
i 6omined empty(pumped)tank � Checked fo�back-up in home O Examined r8o�rds
� Probed outside tank for"black soll" o Exce�lve ponding In soil system/D-boxes C] LGU l.lmlting Layer Verificabion
O Pressure/vacuum check i� Homeovmer te5iimony o Other
o Ott�er ❑ Examfned fnr surging in tank
p "Black sofl"above soil system
❑ Other
on tfie aompllanoe criberia,tl�e sysbem status is: (check one) ❑ failing (to protect groundwater) ❑ an
i minent threat to publfc health or safety (1TPH5), � non�omplient(monitoring Issue). � compliant (non-of the 3
oo�ditions). Is thls systiem a EPA Cls�V I�ectlon Wall? O yes � no
this document!s a: 'Certifica0e of Com iance 0 Notiae of Noncvm liance
I oertify as a staCe of Minne9ola lioensed Inspec�or and/o�Designer I or Qualified Employee Inspector and/or Qualified Employee
ner I tl�at I conduc�ed an irn�tigatlon that a�urately debermineO the eompllanoe�s of tfiis system and that my reoorded
s are acarate as af thls dabe. No determination of future hy�drauli�perfo►mance has been nor can be made due to
u oondifions duHng sys0em oon�ion,abuse of the syskem,lnadequabe malnbenanae,o�futu�e water usage.
I s narne(pririt) �QS�I�h] 0190n Phone:1763]498-$779
and/or Reglstra�on Number�l� AddresS= 11481 Rlvervlew Road NE..Hanover.MN.55341
ployed by- ' Address: 11481 Riverview Road NE.,Hanover.MN._55341
nabu Date: 6/29/06
jdeiivtrd from Minniesl�ta Statutes-§X15.SS)
A 17PHS must be upgraded, r�c�d, or its use discontinr�ed rvithin ten montfis of rac�ipt of Uiis nobce or wrthin a shwter peiio0 if
u�+d by�4aca/orrl/nancae If die syst�m falls lt�Fvavide su�nt qrnunrJw�ter prot�c�ion, then dre system must be upgra�ed,
,cY iLs uste disrs�n�'nued wibhin tl�e lime repuirad by�u/e ar bhe/ara/Ord/nan� If an exls�ng syst�m is not failing as�fiirEd in
!a ,and has at/aast twiv feiet of des�qn s�il s�rabov�, tllen�he system ne�d not de upgrad�d,�pair�d, replaaed, or ils us�
tinuer/,nolwi�h.s�rldi»g any lara/adinanc�that ls more sbict. Th�Cs dc�s noot app�ly to sys�ns/n srio�/an0 a�as, w�ell%a0
� a�s,or those as�d in cvnne�ction wit�"��ad, beverage, and lodging establis�hmenls as def�ned/n/aw.
1) Slke sketch which includes the system Ivcation(mandatory). Other items could fnclude: well, wetl setback to system,dwelling or
olher buildings,tank(s), reserved soll treatment area,surface water and soil boring locations. Include as-built d�awing if available.
2) Soil boring logs,showing eadi horizon. Indicatie the b�cture,mlor,redoximorphfc features depth to hedrock, standing water and
whether the meberial Is HII.
3) A Iist of any and all requirements of the locai ordlnanoe tliat are different from the state requirements referred to on [hls form_
4) A homeowner survey of syst�em perFormance, signed by the homevwner as being Factual.
S) MoniCoring data as appropriat�e.
PageZof2
06/29/2006 23:19 7634988290 RUSTVS PERC TESTING PAGE 65
L of i
Licen�s#810
Locadon or ProJect: 3160 Sussex Road i
Barings made by: Rusty Olson's Soil and Perc testing 6/28IZ006
Classlflcation System: AASHO : USDS-USDS�CS 7�_; Unifled ; Other
Auger used(check two):Hand_X_,o�Power ,Flight, eucket o�Probe�X_
Boring Number 1_Surtace elevation_103.3_ Mottled Soil at_5.5_feet
0"-14"Daric bro�vn bam 10yr3/Z
14"-24"Brown loam 10yr4/4
24"-30"Brvwn clay loam 1 Qy�/4
30"-�2"Brown loam 10yr5/4
42"�6"Brown Ieem some iron nodules no grays 10yB/4
66"-72"Rusty brvwn loamy sand 10yr5/4
Boring Number_2 Surface elevation_106.7_ Mot�ed Soil at X�feet
0"-18"DaAc brown loem 10yr3J2
19"-28"Brown loam 10yr4/4
28"48"Brown Ioem 10yrS/4
48"-72"Brown loem 10yt8/4
06/29/2006 23:19 7634988290 RUSTVS PERC TESTING PAGE 06
�SS � I`U �
� 1 � � s �`- . .
M\`�� .
. �,-.
, �s � 1s��.�.�- � �
F:' . .I
�f�
/ �Z►.
�9/� � �
s;� � t�G.,�� 'S
e
t,�.� c;4�,.
��,�� �� . .
' �(��
� 't` � �
IV
� g .
W � 53� �°� 6�� ._ q .
,N� �. ��i -76 ' 9rar�!�'��p '
�i ' P`'�,P �O . .
� MN3 7�' 6 $ � �Io�S�
c>
�
�
� �
�II .
�-IS-O a
06/29/2006 23:19 7634988290 RUSTYS PERC TESTING PAGE 67
.
�6/Z7iZooB 09:4Y F�X 7998722420 61mer J. Peterson Co. �001
lenk Re�r
, —
; ,
; ,
� I i I
D��: June 27, Z006
�Imet J. Petetson'Co.
59Z1 Daaue Ave.
�Delano, MN 55328
(763) 972-2420/ (952) 471-8151
Randy Peyton
3160 Sus�ax Rodd
Oronv, MN.
Ba�els: � O�F
Tel1k Ca�Gly: � 300 gallons each
�of Tank�: 3
T� ��`�n�,: conczete
���n�: 3000 qallons pumped
Manholes to Grade: YES / NO
No cr�cks found at this time.
NOTE: This is onir e t�nk nport. Thi�i� not a corttpAano� insp�r:tion far poi�t af sale
na dot� it repioos�C�OfnpUsnoe in�pec�ion.
license # 219
� � ,
�O�
O O CI'TY OF ORONO
� � Municipal Offices
v$, �, Street Address Mailiag Address:
� �j'�' 2750 Kelley Parkway P.O. Box 66
'�.� �i Orono,MN 55356 Crystal Bay,MN 55323-0066
k'EsHo4'
To: The Current Owner of Address 3160 SUSSEX RD
City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a
periodic basis. The onsite sewage treatment system at the above address has been inspected and
the following is known about the system. A sketch of the known components of the system is
available for most properties at the Orono City Hall.
Imminent Public Health Threat
Yes �/
No ✓
If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of
this notice. The septic system must be brought into compliance within 90 days. Failure to do so
will result in referral to the City Attorney for legal action.
System Identified as Non- mpliant
Yes
No
If yes, system must be brought into compliance by:
December_31,2007 �
. December 31, 2010 �
Qther
Septic Tank(s)"Pu�out Needed
_ Yes- �/ -
�o.._._ ._..
The city recommends the septic tank(s) and/or lift tank be serviced and pumped out every three
(3) �ears, :City records indicate the tank(s)were last pumped out on �,lo S'�.FO
The tank(s} should be cleaned through the manhole and not through the inspection pipes, this
allows for proper cleaning.
Comments:
�
InspeC�;�J �_ Date of Inspection: �r a �
Telephone (952) 249-4600 • Fax(952) 249-4616
www.ci.orono.ma.us
/ ��
� � s •
�
To: Orono residents on mound type septic systerns
Prom: Willie Gibbs, ISTS Manager
Date: May 10,2006
Re: Landscaping Do's and Don'ts for Mound Systems, Quick Reminder
Do plant and maintain a full cover of grass and keep mowed to a normal height, this grass cover aids
in the evaporation of large amounts of effluent(the iiquid left after the"othe�' stuff has been removed)
in the summer time and allows the mound system to help breakdown nitrogen in the effluent,
Do water the grass over the mound in extreme dry conditions, sparingly.
Do avoid unnecessary foot traffic over the mound, mow it and stay off of it. This is especially true in the
winter time. Even human foot traffic can cause frost to penetrate the mound resul#ing in potential
freezing problems.
Do inspect your mound system annually for winter kill, (reseed if necessary} animal damage,
(burrowing)or signs of potential failure.
Do not plant trees or shrubs on the mound system, smaller trees and shrubs may be planted at the
edges. Remember,that sunshine is the key to a healthy mound system.
Do ask questions, if you have any concerns or questions concerning your mound system
please feel free to call me,I can be reached at 952-249,4626.
1
� °�
o . r o��,
�. ���,�:r���,�- .._ �. !' �I'�Y of ORON4
1''�,r�,, '��' �.r. d,ji", - �,�� Municipal Offices
��; ,�t, ����rc� f�`� ��� � �
\\` '�� . ��'��,��+`�`` G� Street Address: �15a'a49"�I6� � Mailing pddress:
,: .0 � r � .�,
`\�'�� 2750 Kelley Parkway P.O. Boz 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
o Current Owner: Address: �/�G S�S'S�t�'� ��
ity Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
he on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): �
1 "CODE SYSTEM" An LSTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLTANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an imm;nent threat to public health or safety.
3 "NOI�'-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which ma_y
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chazacteristics.
TANI�CONDITION(5-7): �
Tanl:inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure septic tanks are pumped throu�h manhole and not throuQh white inspection pipes. This allows for the proper
cleanina. Keep water softner and iron filter dischar�e out of septic svstem to prolonQ life of drainfield. Ask pumper to test
alarm float to verifv alarm is still workinQ in your house. The alarm warns owner that septaae is about to backup into basement.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tanlc. If
tanl:s have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION(8-10): �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
C MMENTS:
;,
y: -- j
� �'����� � ��
�_ _ .� ) - (.��� `�� � —
Date of Inspection Septic System Inspector
Not : In the event that this inspec[ion report is used to satisfy the requirements for a mortgaee or other transfer of property, be advised that this report does
not uazantee or certify that an existing system will continue to function properly, but is mere.ly an opinion of the adequacy of the system under cuirent
� °� , .
0 0
-�-� � - C ITY of ORONU
,� 's����'��,�- -: �
�',, `�` �'` .���,,:`-j�~ �lS�� Municipal Offices
'� I�(�`�`��''�'s��+'l� �'j i�
� .t -,�`,';�a;��'�R �// Street Address: Mailing Address:
`��i'EggO¢�" 2750 Keliey Parkway P.O. Boz 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
To Current Owner: Address: 3� �f� S�'��S��c �\�I
City Ordinance 199 requires that each existing on-site sewage trea�nent system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
YSTEM CONFORMITY 1-3 : �
1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standazds of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does mcet the three foot separation tequirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may
or may not meet al(the location,design,or construction standazds of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than threc feet of unsaturated soii or sand between the disVibution device and the limiting soil characteristics.
TANK CONDITION(5-7): S
Tank inspection indicates:
� Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure seatic tanks are numaed through manhole and not throu�h white insaection pipes. This allows for the
proper cleaninQ. Keep water softner and iron filter discharee out of septic svstem.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia. pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION 8-10 : �
8 Drainfield is dry,no surfacing evident.
Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
COMMENTS:_ �Q'"`^ � � .S�P N'< }-c�r.k.s IUG�� v�
�o -�-�� G�- /� �--�
Date of Inspection Matt Bolterman - Septic System Inspector
Note: In the event that this inspection repoR is used to satisfy the rcquirements for a mortgagc or other transfer of property,bc advised that this report does not guarantee
or certify that an exisfing system will continue to function properly,but is merely an opinion ofthe adequacy of the system under cuaent conditions based on the available
information.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
SEPTIC SYSTEM INVENTORY
Site Address: 3160 Sussex Rd PID 04-117-23-32-0008
Owner Name: Richard & Patricia Chenitz
Owner Address: 3160 Sussex Rd Long Lake MN 55356-
BuildingType: residence Installer: I.D. Septic
Date of Permit: 8/9/02
System Type: standard trench BR's Designed for 5
In Musa?: No Shoreland?:
SEPTIC TANKS:
Material: precast concrete Capacity: 1300,1300,1300 Tank Filter:
DRAINFIELD:
Treatment Area: 1365 Soil Boring: yes DF Ht above Wt: 3
WELL DATA
Setbacks -Well Tanks: 75+ Well DF: 75 Report In File: Depth: 148
INSPECTION RECORDSPUMPOUT RECORDS- -
Date Notes r Date GallonsOfLiquid 1,
7/1/2007 Okay ! 11/16/2018 3000
6/21/2005 Okay 6/14/2014 3000
10/1/2003 no surfacing 7/20/2011 3000
8/15/2002 installation L 8/7/2008 3000