HomeMy WebLinkAboutseptic info . _��
' s � • •
� �
To: Orono residents on mound type septic systems
From: Willie Gibbs, ISTS Manager
Date: May 10,2006
Ree Landscaping Do's and Don'ts for Mound Systems, Quick Reminder
Do plant and maintain a full cover of grass and keep mowed to a normal height, this grass cover aids
in the evaporation of large amounts of effluent(the fiquid left after the "othe�' stuff has been removed)
in the summer time and ailows the mound system to help breakdown nitrogen in the effluent,
Do water the grass over the mound in extreme dry conditions, sparingiy.
Da avoid unnecessery foot traffic over the mound, mow it and stay off of it. This is especially true in the
winter time. Even human foot traffic can cause frost to penetrate the mound resulting in potential
freezing problems.
Do inspect your mound system annually for winter kill, (reseed if necessary) animal damage,
(burrowing)or signs of potential failure.
Do nat plant trees or shrubs on the mound system, smaller trees and shrubs may be planted at the
edges. Remember,that sunshine is the key to a healthy mound system.
Do ask questions, if you have any concerns or questions concerning your mound system
please feel free to call me, I can be reached at 952-249-4626.
1
- -�-,
�O�
O O CITY OF ORONO
Muaicipal Offices
�,, ti 8traet Address Mailing Address:
�� G�' 2750 Kelley Pazkway P.O. Box 66
�i Orono,MN 55356 Crystal Bay,MN 55323-0066
�'EsHo�'
To: The Current Owner of Address 480 SUSSEX LA
City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a
periodic basis. The onsite sewage treatment system at the above address has been inspected and
the following is known about the system. A sketch of the known components of the system is
available for most properties at the Orono City Hall.
Imminent Public Health hreat
Yes
No
If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of
this notice. The septic system must be brought into compliance within 90 days. Failure to do so
will result in referral to the City Attorney for legal action.
System Identified as -Compliant
Yes
No
If yes, system must be brought into compliance by:
December 31,2007
December 31, 2010
Other
Septic Tank(s) Punp�out Needed
Yes ✓
No
The"city recorrimerids tlie s"eptic tarik(s�;ancU�r.lif�tank be serviced and pumped o every three
(3) years. City records.indicate the-tank(s)were last pumped.outon � .�=/`�O .
The tarik(s) should be�cleaned through_tl�€-marihole and not through the inspection pipes, this
allovws�far�rQ}�.ez-�leamng..� --- _. .. .. . - -
_.. .._ _ _ . _ .�
Coai�ents:-�._... _ .._._ .._ ._,�... ,. __
.__
�_
_ __...>_ .----
^__-.._ _ .
.
__ ---------
. . .. ` _....�_ ...__ . _ �...__-..
_ . _.._..
.__-__ .,_._..._--
Inspector: ._ T : -.-�- �� .+ _ Date of Inspection: � ��
Telephone (952) 249-4600 • Fax(952) 249-4616
www.ci.oroao.mn.us
� °�
o: . o
�^y� �::�..; :_ CITY of ORONa
� ��z���T
,�It:;. �.`,;�-:...,.. '�+r
�,\`� '�Ir , "',;.� ��, Municipal Offices
r ,�'.-y `! t
�\� ��,;,��'� ���� G Street Address: �15a—a49—y6� � Mailing Address:
\��`�k �`E'��p4'� / 2750 Kelley Parkway . P.O. Box 66
��ESK� Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: �'���"a �<..�.5.�� X L ,��'��
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMIT'Y (1-3): �
1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an imoiinent threat to public health or safety.
3 "NON-COMPLIA.NT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any LSTS which may
or may not meet all the location,design,or construction standards of the cuaent Orono Municipal Code and which is fazling for any
reason;and any ISTS with less than three feet of unsaturated soil or sand beriveen the dishibution device and the limiting soil characteristics.
TANK CONDTTION(5-7): C�
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped �- �t�-�G ).
Make sure seatic tanks are pumaed throuQh manhole and not throush white insuection pipes. This allows for the proper
cleanins. Keea water softner and iron filter discharae out of septic svstem to prolon¢life of drainfield. Ask pumuer to test
alarm float to verifv alarm is still workin¢in vour house. The alarm warns owner thst septage is about to backup into basement.
7 Inspection risers missing-tanks could not be inspected: Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumpe�.oat within the last three years,they should be pumped out now.
DR.AINFIELD CONDITION(8-10): � _ _-.-_
8 Drainfield is dry,no surfacing evident. J^
9 Some evidence of surfacing,not critical yet. • —`
10 Drainfield is saturated and visibly discharging untreated effluenf to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS:
. _ "� ����J 4'�
� �r -�� �...�
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requiremenu for a mortgage or other transfer of property,be advised that this report does
not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the systcm under current
� °� � .
o .: o
��`�������z �� CITY of ORONO
, , ? .�
� ,,;��r��;
:,�. �,
�� a�- l4 Municipal Offices
� �,.�.:
� ���.�;�a�,y� ��
� �f�,. ,� Street Addross: Mailing Addross:
�ESYi�4 2750 Kelley Parkway P.O. Box 66
Orona, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address:
��� 5 uSSt-�c �.� ��,
Ciry Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appeazs to fall into the categories checked below.
TEM CONFORMITY 1-3 : �
1 "CODE SYSTEM" M ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the curnnt Oroao Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or oarlier,and which is not failing or
an imminent throat to public health or safety.
3 "NON-COMPLIANT SYSTBM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any ceason;and
any ISTS with less thsn three feet of unsaturated soil or sand between the dishibution device and the limiting soil cheracteristics.
TANK CONDITION(5-7): �
Tank inspection indicates:
5 Pumpout not needed at this time.
6OSeptic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure seatic tanks are pumoed throu¢6 manhole and not throuPh white insuection aipes. This allows for the
proper cleaning. Keeo water softner and iron filter discharge out of septic system.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank, If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION 8-10 : �
Drainfield is dry,no surfacing evident.
Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly dischazging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
co�rrrs: r�o��� \od1�5 �'�_ P�,�� stip �-;� ��k.S sv��.e�
o b'� .
1 O -�_�� c�.� f��-�
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the event that this inspection nport is used to satisfy the roquirements for a moRgage or other uansfer of property,be advised that this ropoR does not guarantee
or certify that an existing system will condnue to function properly,but is merely an opinion of the adequacy ofthe sysum under current conditioos based on the available
information.
Telephone(952)249-4600 • Fax(952)249-4616
www ci_nrnnn.mnu.c
� ��
O�}:� O
��:;��-� ,, CITY of 4RON0
J1 A�� � �
� `�• 1� �+'S:, k;`, ,ti,ti Municipal Offices
� ����!���a��► G
� ' '%``,i��� Street Addrou:
g,4i Mailln�Address:
�'Eg'fi0 2750 Keiley Parlcway P.O. Bax 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
Owner: � �'c.c��` �rv .''��v�
Address:__ y'� S��.SC X I q
Cin•Ordinance 199 requires that each e�sting on-site sewage treatment rystem in Orono be inspected every rivo yeazs.
The on-site se�vage treatment system at the above address has been inspected and appeazs to fall into the categories checked belo�v.
SYSTEM CONFORMITY 1-3 : �
1 "CODE SYSTEM" An ISTS which meets a(1 the location,desi�and construction standards of the cuaent Orono�funicipa(Code.
2 "COI�SPLIANT SYST'EM" An ISTS which does not meet all the(ocatioq design aad construction standacd4 ofthe cunrnt Orono Municipa!
Code but does meet the three foot separation requiremrnt,aad which is not failing or an imminrnt t}ueat W public health or safety.
3 "NON-COMPLIANf SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year Aood plain,any ISTS which may
or may not meet all the locatioq design,or construction standard4 ef the current prono�tunicipal Code and which is failing for any reason;and
any ISTS with las than three faet of unsaturated soil or sand between the distribution device and the limiting soi(characteristics,
T:�.'VIC CONDITION(�-10): �_
•nk inspection indicates:
� Pumpout not naeded at this time.
Tank must ba pumped out this yaar (city code requires tanks to be pumped out every 3 years. Tank was last pumped �,
7 Solids accumulation in t.v�ks is at a crilical a critical lavel. Tanks should be pumpad out as soon a�possible.
8 System is discharging to tha surfaca. Tuiks must be pumped out within 48 hours to eliminata surface discharge.
9 Iacpaction risers missing-tanks could not be inspecead Inspection risers(4"dia pipe)must ba installed in each tank at neM pumpout If tanks
ha�•a not been pumpad out within the last three yeacs,they should be pumped out now.
10 Inspection pipe is located directly over tacdc ba�le(does not give accurata measuremmt of solids aecumulation). If tanks have not been pumpad
out withiit the lact three years,they should be pumped out now.
D LD CONDITION 11-1� : �
11 rainfieid'u dcy,na surfacing evident
12 Some evidence of surfacing,not critical yet
13 Dra�eld is saturatad and visibly discharging untreated e@lurnt to tha surface. Contad the City Inspector immediatety.Repairs must be
completed within 90 days.
1� Drsintield astant and condition unknown.
COM�NTS: S �(S'SC �--- � b b`�� �� _
��-.0 - D \ �
. Dace of Inspcction . +
Septic System Inspector
Note: In the event that this itupection repoR is ased to satisfy the requuemrnts for a mortgage or otha transfa of property,be advised that this report doa aot guacantee
or certify that an a�sting system will continue to function properly,but is mere(y an opinion of the adequary of the sysiem uada cucrmt eond�e;�nQ hx.�,��.,rt,�a�a�t�t,it