My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
04/21/1999 -letter re: Septic System Site Plan
Orono
>
Property Files
>
Street Address
>
C
>
Carriage Lane
>
2120 Carriage Lane - 10-117-23-24-0036
>
Septic
>
04/21/1999 -letter re: Septic System Site Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:22:12 PM
Creation date
3/27/2019 2:44:12 PM
Metadata
Fields
Template:
x Address Old
House Number
2120
Street Name
Carriage
Street Type
Lane
Address
2120 Carriage Lane
Document Type
Septic
PIN
1011723240036
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Z zo Carr aLvt, lavu <br /> ' Westwood Professional Services,Inc. <br /> 104 Marty Drive,Suite 3 <br /> Buffalo,MN 55313 <br /> Phone:612-682-2587 <br /> Fax:612-682-2639 <br /> Toll Free: 1-888-682-2587 <br /> April 21, 1 999 Email:wps@westwoodps.com <br /> Steve Bohl <br /> Bohland Development <br /> 420 Upland Lane <br /> Plymouth, MN 55447 <br /> RE: Septic System Site Plan for Lot 5, Carriage Hill, Orono, Minnesota. <br /> Dear Steve: <br /> This proposed on-site septic system was designed for a 5 bedroom home, with an estimated flow of 750 <br /> gallons per day. Due to mottled soils at a depth of 24" in the primary site, the primary will need to be a <br /> mound system with 12"of sand under the rockbed at the upslope side. The site in which this system is <br /> proposed has a existing ground slope of 6%, and percolation rates ranging from 11-20 MPI. The rock <br /> bed size will be 10 feet wide and 63 feet long with the overall dimensions of the primary mound being <br /> 101.0 feet long and 38.6 feet wide. <br /> An alternate septic system has been shown on the plan to show that there is enough undisturbed area on <br /> the lot to support another septic system. This system will also need to be a mound system. Mottled <br /> soils were found at a depth of 24 inches and the average slope of the area is 4%. This system will not <br /> need to be constructed unless the primary mound fails. <br /> Certain precautions will need to be made to protect the areas in which the above referenced septic <br /> systems are proposed. Both primary and alternate septic areas have been or will be staked off. It is <br /> recommended that safety fence be placed around both of the sites for protection during construction of <br /> this project. It is critical that the soil is not disturbed before, during, and after construction of the <br /> system. <br /> These system should treat the septic effluent effectively if the systems are installed properly and are <br /> maintained properly. It is recommenced that the septic tanks be pumped once every two years. This <br /> will reduce the chance of solids reaching the system. It is also recommended not to use excessive <br /> amounts of chlorine, soaps,and chlorine products which can kill bacteria in the septic tanks. This <br /> bacteria is needed to treat the septic effluent <br /> Designing the Future Today.since 1972 <br />
The URL can be used to link to this page
Your browser does not support the video tag.