HomeMy WebLinkAboutseptic info _.-o�������
;:- � � ��,,,
,�
/;i ,;
j;' , ;:� :,_ 'i CITY of ORONO►
�� a , a� �
�, k, �, � �,,/ Municipal Offices
� ti,;;;
��,� �� . :< ;' ,�G; � Street Address: Mailing Address:
�.kE,$xp4� 2750 Keltey Parkway P.O. Box 66
�- Orono, MN 55356 Crystal Bay, MN 55323-0066
To: The Current Owner of Address G/�d S �v t3�.�5 ��`� �
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes �No
If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identified as Non-Compliant
Yes �No
If yes, system must be brought into compliance by:
December 31,2007
December 31,2010
Other �
Septic Tank(s) Pump out Needed -
Yes �,_
No �
The City recommends the septic tank(s) and/or lift tank be serviced and pumped
out every three years. CiTy records indicate the tank(s)were last pumped out on
,2- G� - � S . The tank(s) should be cleaned through the manhole and
not through the inspection pipes,this allows for proper cleaning.
Comments:
y
���
Inspector: Date of Inspection �d � �
Telephone(952)249-4600 • Fax(952)249-461b
www.ci.orono.mn.us
�°� �
o :.:, o
���-�T � �- CITY of ORONO
. `� �' ���.-`� Ht�� o�
'� � �' �
�` ' ,�yG SVeet Addreaa: M�ilm�A�ress:
, }���i t. M
E+g�0�' 2150 Kelley Pa�kway P.O. Box 66
Orono, MN 55356 Crystal Bay, 1�l 55323-0066
To Current Owner: Address: `7'�� s�V� Utiy i�(1 ��/.
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into ffie categories checked below.
TEM CONFORNIITY 1�: �
1 CODE SYSTEM"M iSTS which mcets all the location,design and wnstruction standards of the c�urent Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not mcet all the location,design and construction standards of tl�e current Orono Municipai
Code but dces meet the three foot separation trquircanent or two foot requirement for systems installed 1996 or earlier,end which is not failing or
an immiaent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located witfiin a designated 100 year 800d plein,any ISTS which may
or may not meet all tl�e location,design,or construction standards of the current Orono Municipal Code and which is failing for nny reason;and
any ISTS with less t6an three feet of unsaturated soil or sand betwan the distribution device and the(imitin�soil char�cteristics.
TANK CONDITION(5-7): �,_
Tank inspection indicates:
5 Pumpout not needed at this time.
�Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure se�tic tanks are pumped throueh manhote and not t6rou�h white insnection pipes. This allows for the
proper cleaning. K�p water softner and iron filter discharge out of se�tic svstem.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,ihey should be pumped out now.
D IELD CONDITION(8-10): �
8 Drainfield is dry,no s�u�facing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saxurated and visbly discharging untreated ePfluent to the surface. Contact d�e City Inspector
immediately.Repairs mnst be completed within 9fl'days.
COMIt�NTS: /�►� .•a ����f S �K. Q�� SC r �� �.Z.
�°lV�. ..6 c�.. v.� ti--� =� �'1! � r�
Lv''� :c.1Q C�h-:.�.� �`�'l.� �c'C) Q►« t 0 ^ l��D V� i
°��.1-� G�r� F�.
Date of Inspection Matt Boltamsn- Sepdc System InsQcctor
Note:Io d�ev�t th�this iospocxron report is used oo�atisty the reqaiiements f�a roortgege or other transfer of P�P�Y,be advised that ffiis report does not guuaneee
w c�tify th��existing system will contimx to function properlY,but s merely�opinion ofdte a�dequs�y of�e system under c�nent aonditioaa b�ed a�the avsilable
a�formati�.
TielepLone(952)1A9-�600 • F�x(9S2)249-4616
�ve�v.ci.orono.tnn.�
� '�, 0,�. .
� �s„�. � �
� ������ CITY of �]EtONO
,.:?.
����.��? �,
,3 �;��' �;` ��;� �
� �S• �%:�, ,(� ,ti, � Municipal Offices
���`��`�'t�;`''���'yG � Street Address: Mailin Address: �
S
,`�'Eg�i�g 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: � v�U b.q il S� � 4 tJ� �� /�/
Address: �� St�l�b5 ,�
Ciry Ordinance 199 requires that each existing on-site se�vage treatment system in Orono be inspected every two yeazs.
The on-site se�vage treatment system at the above address has been inspected and appeazs to fall into the categories checked below.
SYSTEM CONFORMIT'Y 1-3 : � '
1 °CODE SYS'TEM" An ISTS which meets all the locatioq design and constcuction standards of the currrnt Orono bfunicipal Code. ,
2 "CO�LIANT SYSTEM" An ISTS which does not meet a11 the location,daigt and construction staadards of the currrnR preao Municipal
Code but doa meet the three foot separatioa requirement,and which is not failing or aa�r*+*+��•�thceat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prolu'bited ISTS;an ISTS located wiWin a desig�ated 100-year flood plaia,aay ISTS which may
or may not meet all the locatioq drsign,or coastruction staadards of the cutreat Orono btunicipal Code and which is failing for any reazon;and
any ISTS with las than three feet of unsahuated soil or sand betweea the distdbution device and the limitin�goil characteristics.
TA��TK CONDITION(5-10): 6 . �
Tank inspection indicates: �• -
� Pumpout not needad at this time.
� Tsnk must be pumped out this year (city code requires tanks to be purnped out every 3 years. Tank was lut pumped U��`-'^ ),
7 Solids ac�vrtiulation in tastks is at a critical a critiralleveL Tanks should be pumpad out as soon as possibla.
8 Systtm is discharging W the surface. Tanks must ba pumped out withict 48 houts to eliminate surface discharge.
9 Inspection risers missing-tanks could not be ir�pected Irupaction risers(4"dia pipe)must be installed in each tank at next pumpout If tanks
have nut bean pumprd out wiehin the(ast three years,they should be pumped out now.
10 InspaKiun pipe is locatad direcdy over tank baffle(does not give accurate measurement of solids accumulsdon). If tanks hava not been pumped
out within tha Isct thrae yeus,thay should be pumptd out no�v.
D IELD CONDITION 11-14 : �_
Drsinfield is dry,no surfacing evidrnt
12 Some e�ndmce of surfacing,not critical yet • � ' '
13 Drainfield'u sstucated and visibiy dischacging unttrated eHlurnt to tha surfaca Contact the City Icupactoc immediataly.Repaics must be
completedµithin 90 days.
1� Drainfield estent and condition unknown.
CONMENTS: S s-�e� � \oak C� �. _ ��N, t�,�ks �� �,�� ��� c•d�'
bc�.. �� �.. ,- .,� ��, 3 � � rs.
°�-1�6\ �
Date of Inspectioa Se he S �
p� ystem Inspector
Nota: Ia the event that this iaspection tepod is used to satisfy the tequimaents for a moctgage or other t�cansfa of property,be advised that this report daes nat guarantae
or cectify that an e�sting sysum will continue to functioa propezly,but is merely aa opiaion of the adequary of the system uader current eonditiaag based oa the available
informatioa
CITY OF ORONO �O�
Municipel Offices O O
Post Office Box 66
Crystal eay, MN 55323-0066 � � ON—SITE SEWAf3E TREATI�NT
�C,, INSPECTION REPORT
'�, Gti'
�9kESI;Og'�
Owner: ��Q' l.:�ALlSE Address: YSD S�dhs �J�9.�/ /pC�, /l� 55356,
Permit #'a: � y Dates: y`o��'- 1�8 Contractora: /`�i�¢TNdI�� ,�3205.
City ordinance nunber 100 requires that each on-site sewage treetment system in Orono be inspected on a regutar besis.
The on-site sewage treatment system at the above address has bee� inspected and appears to falt into the category
ehecked below.
(This is� an existing system [ ] new construction)
SYSTEM CONFORM[TY (1-3):
1 "COOE SYSTEM��-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING S�STEM"-A system which does not meet all the location, design, and construction standards of the
eurrent City Codes, but was instalted according to the code in effect at the time of instaltati�, and which
is operating satisfactority by treating and disposing of the entire current sewage input without discharging
any pollutants into grand or surface waters.
3 "NON-CONFORMING STSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand
between the distribution device and the timiting soil characteristics.
(The limitin� soil characteristic�as or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.)
TANK CONDITION CS-10):�
Zanl� inspection indicates:
�J Punpout not needed at this time.
6 Solids eccunulation in tanks indicates they should be �� out this year to help prevent future problems.
7 Solids aecunulation in tanks is at a critical level. at nks should be p�rnped out as soon as possible.
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface discharye.
9 inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next punpout. If tanks have not been punped out within the last three years, they should be purped
out now.
10 Inspection pipe is loceted directty over tank baffle (does not give accurate measurement of solids accunutation).
If tanks have not been punped out within the last th�ee years, they should be punped out now.
DRAINFIELD CONDITION C11-14]:
D field inspection indicates:
11 Drainfield is dry, no surfacing evident.
�Some evidence of surfacing, not critical yet.
13 Drainfietd is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Dreinfietd extent and condition unknown.
LIMITING SITE FACTORS (sloce.setbacks.etc.): �
POTENTIAL FOR SYSTEM FAILURE (deoerids on soils.water table etc ): �n�
' COMMENTS: �fJ O�t S
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this �eport does not guarantee or certtfy that an existing system will continue to f�ction
properlys but is merely an opim on of the adequacy of the system under current conditions based on the available
�nformat�on.
fihis report must be kept on the premises with the system locstion end punping records.
WHITE COPY/lnspeeton File YELLOW COPY/Homeowner
� o�
0 0
�;�#j�,:-� �, CITY of ORONO
�►�,, �` �` !4 Municipal Offices
,�, ��;����i���� �ti
� '�' �'�`� Street Address: Mailing Address:
, ,,`r.���.�� �j
'9$EgHOg' 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
�'��;� � LJ;�?
Owner: r � Address:480 Stubbs Bay Rd. N.
Permit #'s:3294 Dates:9/8/72 Contractors:owner-Lathrop
(This is [�] an existing system [ ] new construction)
SYSTEM COMPLIANCE (1-3) : 3
1 Code Svstem; Meets or exceeds current City standards in all respects relating to
design, construction, and location. Appears to be operating properly.
2 Compliant Svstem: Does not meet all current City standards for new construction,
but in most respects appears to be designed, located, and constructed in accordance
with previous codes and is functioning properly.
� Non-Compliant Svstem: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the
current input; and any system with less than three feet of vertical ae�arar_;on
between the bottom o� t�—Te drainfield and the saturated soi evel.
(The saturated soil level J� has or [ ] has not been identified at this time. If the
saturated soil level has not been identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 9
5 Pumpout not needed at this time
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been
pumped out within three years, they should be pumped out and risers installed now.
� Inspection pipe is located over tank baffle-can not measure solids accumulation. ��
tanks have not been pumped out within three years, thev Gh�»i� �-� n��;��a �„r „oW.
--� ,� •--T�_
(During the last septic tank Maintenance Pumpout the tanks [ ] were or !�1 were not
confirmed to be watertight by the licensed pumping contractor. If the tanks were not
confirmed to be watertight, this classification is subject to revision.)
DR.AINFIELD CONDITION (11-14) : 11
1 � Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (svstem aae and condition, soils, etc. ) : high
CONIl�IENTS: Tha non-compliant septic system must be repaired by 12/31/2006 or within 90 days
of failure (surface discharge) , whichever comes first. f
_�v�-l� ,�� ,��,.�.�-
Date of Inspection Sep c System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue
to function properly, but indicates the operation of the system under current conditions.
Tetep6one (612) 473-7357 • FAX 473-0510
CITY OF ORONO �O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON–SITE SEWA(�E TREATMP;NT
� � INSPECTION REPORT
ti
��9kESH0��G
Owner: ���1��("Y�'�!/�� Address:
Permit �'s: Dates: /�ct�7� Contractors: OJ�1/�GC�T/11�i�/�
City ordinance number 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is ;� an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3): �
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in etfect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; arxi any system with less than 3 feet of unsaturated soil or sand
betWeen the distribution device and the limiting soil characteristics.
(The limiting soil characteristic [ ] has or,DSi has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10): �
Tank inspecti�n �ndicates:
5 P needed at this time.
� � unulation in tanks indicates they should be p�rriped out this year to help prevent future problems.
accumulation in tanks is at a critical level. Tanks should be pWnped out as soon�as �ossible.
8 System is discharging to the surface. Tanks must be pumpe�IIt�rrtfTiTf48'�idOF� o e iminat—e s0'f"r�C�Thschar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next �xmpout. If tanks have not been pumped out withtn the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been punped out within the last three years, they should be pixnped out now.
DRAINFIELD CONDITION (11-74):
Drainfield inspection indicates:
}�, Drainfield is dry, no surfacing evident.
/77! Some evidence of surfacing, not critical yet.
`TS Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and corxiition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (deoends on soils,water table,etc.):
COMMENTS:
Date of Inspection e ic System Inspector
Note: In the event that this inspection report is used to satisfy the requirerr�nts for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the precnises with the system locetion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
On the North Shore o f
Lake Minnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � Crystal Bay,MN 55323
473-7357
OWNER ��v/ � L�no�tlSP� ADDRESS �"`�' �S�i/� 1C �JL/f
PERMIT NO.'S. 3�/`� DATES ��7� CONTRACTORS��'1�_-'_��./l�r�
City Ordinance No. 210 requires that each on-site sewage treatment syatem in Orono be inspected on a regular basis.The onsite sewage
treatment system at the above address has been inspected a�d appears to fali into the category checked below.
(This is �5-an existing system ❑ new construction)
� � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appean to be operating
properly.
� 2 Does not meet all current City standerds for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major
upgreding of the system is required at this time.
� 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating
adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at
thia time.
� 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or ia otherwise creating a public nuisance.Please contact the City I�spector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted fo�review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION (m Checked items may require your action)
Tank'nspection indicates: ❑ Inspection pipe is located directly over tank bsff�e.(Does not
�Pumpout not needed at this time, give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump� have not been pumped out within the last three years,they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. ❑ Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Drai�field is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inapected. effluent to the surface. This condition may require replace-
Inspection risera (4"dia.pipe)must be installed in each tank ment or additions to drai�field. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. �Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiti�g Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table,and system condition) �Adequate
❑ High water table ❑ Low Fair
❑ Lot size �Medium ❑Poor
❑ Lake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage ❑System is causing visible
surface discharge.
COMMENTS:
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner