Loading...
HomeMy WebLinkAboutseptic info ,-_o_�,, � ;� ��� �� ��., ;:�o �� i'►'' � '` CITY of OIZUNO , �,i `'� � � ,.T �J% Municipal Offices '�� � li' �k � ,:: � � � + ;' G � Street Address: Mailing Address: �9kEs.Kp4� 2750 Kelley Parkway P.O. Box 66 � Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Current Owner of Address c.��� 5'U i3� S 3.�,{ � City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No _� If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes �No If yes, system must be brought into compliance by: December 31,2007 December 31,2010 Other ' Septic Tank(s)Pump out Needed Yes �_ No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on ; Cv -�3-v� . The tank(s) should be cleaned through the manhole and not through the inspection pipes,this allows for proper cleaning. Comments: � n ` Inspecto . � Date of Inspection �� -�� Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us � �� � . O .:; O ��°���T� � . CITY of ORON4 . � ������;�, � Nt��t� ot��� � ��{` ~ ����.��� � .� l,;}�f���:g .� Stroet Addross: Mailing Address: '9$�xpg' � 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 To Current Owner: Address: �� `S�-'bbs Q�'��! ��� N� Ciry Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatrnent system at the above address has been inspected and appears to fall into the categories checked below. SYSTBM CONFORMITY 1-3 : � 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the currcnt Orono Municipal Code. 2 "COMPLIANT SYST'EM" An ISTS which does not meet all the location,design and construction standards of the current Omno Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or eartier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYS'TEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipsl Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characuristics. TANK CONDITION(5-7): � Tank inspection indicates: 5 Pumpout not needed at this time. �Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tanlc was last pumped 7 3�`16 ). Make sure seotic tanks are uumped throug6 manhole and not throush white insuection uipes. This allows for the proner cleaning. Keep water softner and iron filter discharge out of septic svstem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DR INFIELD CONDITTON 8-10 : 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacittg,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: �e<�-��.;e\� 1�c`LS Ol�-, Q u�� S c P�:�-- '��ICS 6 r,c,L ��i��� � �!���C S � a-L�--o"� ��u,� �� Date of Inspection Matt Bolterman - Septic Systern Inspector Note: In the event that this inspection report is used to satisfy the requiromenis for a mortgage or otha transfer of propercy,be advised that this report does notguarantee or cerdfy that an existing system will continue to function properly,but is menly an opinion of the adequacy ofthe system undercurrent conditions based on the available information. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us � � °� .. � 0s,::��. 0 � � ���=���� CITYof �RONO ,.: '�"�.�: �' .,.r. ,�+ ;� 1���'-;��°�(� ,�,ti .. MunIcipal ,� ��.,-.:tii ",'�f�a Of�ices � "'• '��}" "'���iG Street Address: Mailing Address: , ,• • ��,¢ . �'Eg��I� 2750 Kelley ParkwaY P.O. Box 66 Orono, MN 55356 Crystat Bay, MN 55323•0�66 Owner: ( �,t'�� S `�d�� �S � Address: �-� S�-u b bS � �/ Ciry Ordinance 199 requires that each existing on-site servage tr�atment system in Orono be inspected every tcvo yeazs. The on-site sewage treatment system at the above address has been inspected and appeazs to fall into the categories checked beloc�. !STEM CONFORNIITY 1-3 : � . � 1 "CODE SYSTEM" An ISTS which meetc a11 the locatioq design and constcuction standards ofthe current Orono bfuaicipal Code. . 2 "COI�LIANT SYSTEM" An ISTS which does aot meet a11 the location,design and constcuction staadards of the eurrrnt Orono Muaicipal Code but doss meet the three foot separation requirement,and which is not failing or aa immine�threat to public health or safaty. 3 "NON-COMPLIANT SYSTEM" A pmhibited ISTS;an ISTS located within a desigiated 100-year flood plaia,aay ISTS which may or atay not meet all the locatioq desig�or coastcuction standards of the cuaent Orono blunicipal Code aad which is failing for any reasoa;and any ISTS with less than three feet of unsahuated soi!or sand betwern the distnbution device and the limiting soil characteristia, TANK CONDITION(5-10): G . � � Tank inspection indicates: �• • Pumpout not needed at this time. 6 Tank must be pumped out this year (city code requira tanks to be pumped aut every 3 years. Tank was lut pumped �—�' � � ), Solids ac�vmulation in tanks is at a critical a ailical leveL Tanks should be pumptd out ac sooa as possible. $ S�stem is discharging to tha surface. Tanlcs must ba pumped out within 48 hours to eliminate aurface d'ucharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risats(4"dia pipe)must be installed in each tank at next pumpout fftanks have nut bean pumpad out within the last three years,they shculd be pumped out now. 1� Inspectiun pipa is located direcdy over tanlc ba@le(doas not give aaurate measurement of solids accumulation). If i.lnks havz not bern pumped out�vithin the last three yeazs,they should be pumped out now. D IELD CO�IDITION 11-14 : � 11 Drain.fiald'u dry,no sarfacing evidrnt 12 Some e�ndance of surfacing,not criticsl yet • � ' ' 13 Drsinfieid is satur.►tad and visibly discharging untreated e@luent to tha surface. Contact the City Inspector immediately.Repaus must be complrtedµithin 90 days. 1� Drainfield estrnt and condition unkno«n. COM�NTS: S�IS�-c� . � O Ok� �� _ `� �r. �-��� S - �—\� —0 \ � � ,� Date of Inspcction Septic System Iaspeetor ' Nate: Ia the evmt that this iaspcctioa repod is used to satisfy the requiremeuta for a madgage or otha ttansfa of property,be advised that this repod daes nat guaraniee o�eectify that an esisting systam will eontiaue to functioa properly,but is merely an opinioa of the adequary of the systam under eucreat conditiom based on the availabta infocrostioa CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal eay, MN 55323-0066 � � ON-3ITE SEWAQ�E TREA'1'l�NT INSPECTION REPORT � Gti �9kESHOg'� Owner: �l�r�$�A�bR, � IIIS Address: �Z� ���75 �!¢�/ /�•� �''j3�'(,J Permit #'s: /�y Dates:_ ��� ZC�-'$�] Contractora: W!�l�td'ti �/10S . City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category eheeked below. (This is,j� an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "COOE SYSTEM"-A system which meets all the location, design, and construction standa�ds of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING S1fSTEM"-A system which does not meet all the tocation, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which mey or may not meet ell the location, design, and construction standards of the current City Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting so�l characteristics. (The limitin� soil characteristic �Q has or [ � has not been identified at this time. If the limiting soil characteristic has not been identi�fied, this classification.may be subject to revision.) TANK CONOITION CS-10): � Tip(c inspection indicates: ��J Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be punped out this year to help prevent future Probtems. 7 Sotids accurulation in tanks is at a critical level. Yanks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar$e. 9 Inspection risers missing-tanks coutd not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next p�mpout. If tanks have not been punped out within the last three years, they should be punped aut now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out within the last three years, they should be pu�ed out now. QRAINFIELD CONOITION (11-14): ` D�nfield inspection indicates: 11 Drainfietd is dry, no surfacing evident. Sane evidence of surfacing, not eritical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City inspector immediately. Repeirs must be compteted within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE PACTORS Cslooe.setbacks.etc.): W�}.f�,��q��� POTENTIAL FOR SYSTEM FAILURE (decends on soils.water table etc.): �0� _l ' COMMENTS: � . Date of Inspection Septic ystem Inspector • Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system witl continue to function properly� but is merely an opim on of the adequacy of the system wxler current conditions based on the available informat�on. `This report must be kept on the prerises with the system location and punping records. WHITE COPYlI�apectors Fite YELLOW COPY/Homeowner � O� O : O � � -�� CITY of ORONO '����'r�� '� � � � �` � �l4 MunicipalOffices �� �� ���'����`� G Street Address: MailinQ Address: '�,9�` �i�i4��� 4,'`Y $'EgHO 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystai Bay, MN 55323-0066 )� Owner: ��n�� � �� . / Address:220 Stubbs Bay Rd. N. Permit #'s:484 Dates:ll/20/87 Contractors:Widmer Bros. (This is � an existing system [ ] new construction) .��YSTEM COMPLIANCE (1-3) : 1 ( 1� Code Svstem,: Meets or exceeds current City standards in all respects relating to `J design, construction, and location. Appears to be operating properly. 2 Compliant Svstem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant Svstem: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level �] has or ( ] has not been identified at thia time. If the eaturated soil level has not been identified, this classification is subject to revision.) . K CONDITION (5-9) : 5 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or � were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision.) AINFIELD CONDITION 11-14 : 11 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system aae and condition, soils, etc. ) : low COMMENTS: �`/�--�`r� , �--� Date of Inspection ep c System Ins ector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telep6one (612) 473-7357 • FAX 473-0510 CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT „� � INSPECTION RLPORT ti ��`�kEsKo�`'�o Owner: C�i J� ����� Address: oSo�� S7U�S' �i/ /�d•/i/i � �� Permit �'s: Dates: l�d'��"�7 Contractors: //1%��1� L�1�L�S- City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is {� an existing system [ ] neW construction) SYSTEM CONFORMITY (1-3): � 10 ��CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface r►aters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting sotl characteristics. (The limiting soil characteristic �has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): T� inspection indicates: Ptmpout not needed at this time. Solids accunulation in tanks indicates they should be p�xnped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. 'fanks should be punped out as soon as possible. 8 System is discharging to the surface. 7anks must be punped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) �st be installed in each tank at next purtipout. If tanks have not been ptmped out uithin the last three years, they should be punped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out within the last three years, they should be punped out now. DRAINFIELD CONDITION (17-14): D�ey�field inspection indicates: (1y Drainfie[d is dry, no surfacing evident. 'T2 Sane evidence of surfacing, not critical yet. 73 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City lnspector immediately. Repairs must be completed uithin 90 days. 74 Drainfield extent and condition unknown. L1MITING S1TE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE Cdepends on soils,Water table.etc.): �� COMMENTS: Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay, MN 55323 473-7357 OWNER � � ADDRESS a � �"► PERMIT NO.'S. DATES /�a��$7 CONTRACTORS P �� City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be i�spected on a regular basis.The onsite sewage ueatment system at the above address has been inspected and appears to fall into the category checked below. (This is �an existing system ❑ new construction) � � Meets or exceeds current City stendards in all respects relating to design,construction,and location.Appea�s to be operating properly. � 2 Does not meet alt current City standards for new constructio� (1978 Code) but in most respects appears to be designed, Iocated, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Does not meet current City atandards in many respects relating to design,construction,or locatio�.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for desig�,construction or location,but is fai�ing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) ,Tan�kJ'nspection indicetes: ❑ Inspection pipe is located directly over tank baffle.(Does not � �Q Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Sotids accumulation in tanks is at a critical level. Tanks Drain ield inspection indicates: should be pumped out as soon as possible. �rainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risen (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector et next pumpout. If tenks have not been pumped out within immediatety.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Fut�uj e Expansion ❑ Soil table,and system conditio�) '�I-Adequate ❑ High water table �L.ow � Fair ❑ Lot size b Medium O Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑System is causing visible urface disch ge. / COMMENTS:� � �� � i� 'P! R �C7C�T �l�-�� - Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existi�g system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner