Loading...
HomeMy WebLinkAboutseptic info �o� . . o ::2 .. . o ��:��::_ ,, CITY of OR4N0 � � . ;�� �.�j,, �ti M�;�� ot��� � ��.�',�jf.�'�`�" G \,� '�;�,��; ,� Street Address: Mailing Address: '�'Egg04 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: ��5 � ��"( Z`'t� �U�V d � City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): � �"CODE SYSTEM" An ISTS which meets all the location,design snd construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the cumnt Orono Municipal Code but does mat the thnee foot separation roquiroment or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 'TTON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or wnstruction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting sail characteristics. TANK CONDITION f5-7): � Tank inspection indicates: 5 Pumpout not needed at this time. � Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped �a-1-S�� ). Make sure sentic tanks are pumned throug6 manhole and not throuQh white insaection oines. This allows for the proper cleanin¢. Keea water softner and iron filter dischar¢e out of septic svstem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION 8-10 : Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. co�nv�rrrs: r.•o�,� �- st��.z -3-�;.� l ooi� o�, �u�.� sc���� ��.\L� � �cc_. �vc�...� 3 ye�c S - l U-'L'S—U^� ��'`�ct;� /r --. Date of Inspection Matt Bolterman- Septic System Inspector Note: in the event that this inspection nport is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guerantee or certify that aa existing system wilt continue to function properly,but is merely an opinion ofthe adequacy ofthe system under currentconditions ba4ed on the available information. Telephone(952)?A9-4600 • Fax(952)249-4616 wvvw.d.ornno.mn.us . � °� � , o. o � . r ��:�� CITY �����:�:? ,� of O]EZON4 � y;+�;r:���;� ti �+',� �i.;�,t'�;��,1�� G'y . Municipal Oftices ,i;•.�; � • ,• •;;;•�4�i Street Address: Mailing Address: � .�ESIIO 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 Owner: �G`(''� '�'. f �2�e.r' Address: 4 SS� �y 1�►� ���'d , Ciry Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every rivo years. The on-site se�r�age treatment system at the above address has been inspected and appears to fall into the categories checked below. YSTEM CONFORMITY 1-3 : 1 ' 1 "CODE SYSTEM" An ISTS which meets a11 the location,daign and construction standards of the cuaent Orono hfuaicipal Code. 2 "CO�LIANT SYS'TEM" An ISTS which does not meet all the locatioq design aad cronstruction startdards of the currrnt Orono Municipal Code but doa meet the three foot separation requiremen�and which u not failing or aa immiaeat threat to public health or safety, 3 "NON-COMPLIANT SYSTEM" A pmhibited ISTS;an ISTS located within a designated 100-yeaz flood plain,aay ISTS which may or may not meet all the locatioq design,or wnstruction standards of the curreat Orono htunicipal Coda aad which u failing for any reasoq and any ISTS with las than three feet of uruaturated seil or sand betwern the distn'bution device and the limiting soil characceristics, TANK CONDITION(5-10): � � Tank inspecdon indicates: .• - � Pumpout not needad at this Ume. �� Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was lact pumped ��(—�-\ �, J � Sotidi aa�umulation in tanlcs is at a critical a critical(aveL Tanks should be pumped out as soon as possibla. 8 S sta ' o tha surface. Tanks must be pumped out within 48 hours to atiminate surface d'ucharge. 9 Ins ection risas missing-anks could not ba inspectad Inspection risecs(4"dia pipe)must ba installad in each tank at next pumpout If tanks have nut been pumpe out within the last three years,they should ba pumped out now. 10 Inspectiun pipa is located dira:tly ovec tank ba�le(doas not give accurate mrasurement of solids accumulation). If tanks have not bern pumped out�vithirt the tast three years,they should be pumped out no�v. DRAINFIELD CONDITION 11-14 : �\ 11 rsinfield is dry.no surfacing erident 12 Some e�ndence of surfacing,not critical yet . ' ' • 13 Drainfeeld'u saturstad and visibly discharging untreated e@luent to tha surface. Contact the City Inspector immediataly.Repaus must be complrtad«ithin 90 days. 1�F Drainfiald a�trnt and condition unknown. COMI�NTS: 5 S�^-� � �06�5 �K- _ v^� -���kS _ fVc�P ��Se�S 10 -1 -� \ �� Date of Iaspectioa Septic System Iaspector � Note: In the event that this inspectioa repad'u used to satisfy the requiremenis for a moctgage or other tiansfer of property,be advised that this repod doa not guarantae or eertify thai an esisting rystam will contiaue to funetion properly,but is mereIy an apinion of the adequacy of the system unda eucreat eoaditioas based oa tha availsble infocmatioa CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(;S TREAT�NT INSPECTION REPORT ti ti '�',� G 9kEsH.o�'� Owner: �Ak`( � /J61/ERI� �j�e�2/E/� Address: KS55 Wr��?_vt-'� ��VD ( � Permit #�'s: C��d6 Dates: �� 22 8 Contractors:�� U�JII�Cd�J City ordinence number 100 requires that each on-site sewage treatment system in Orono be inspected on e regular besis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): I 1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into grow�d or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the lxation, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "N�1-CONFORMING SYSTEM°-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, end construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limitin� soil characteristic [ ] has or I ] has not been identified at this time. If the limiting soil characteristic has not been identified, this clessification may be subject to revision.) TANK CONDIT[ON (5-10): Tank inspection indicates: 5 Punpout not needed at this time. 6 Solids accunulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible. System is discharging to the surface. Tanks must be p�mpEd out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. lnspection risers (4" dia. pipe) must be installed in each tank at next Fxmpout. If tanks have not been punped out within the last three years, they should be punped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out within the last three years, they should be punped out now. DRAINFIELD CONDITION (11-14): � Dr nfield inspection indicates: �1 Drainfield is dry, no surfacing evident. TZ Same evidence of surfacing, not critical yet. 13 Drainfield is satureted and visibly discharging untreated effluent to the surface. Contact the City Inspector iim�ediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition �known. LIMITING S1TE FACTORS (sloae,setbacks.etc.): W�q,.{��{-�(L, POTENTIAL FOR SYSTEM FAILURE (decends on soils,water table,etc.): �y—lj��� COMMENTS: i Date of Inspection Septic System Inspector Note: in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opim on of the adequacy of the systern under current conditions based on the available informetion. This report must be kept on the premises with the system locetion and punping records. WHITE COPY/Inspectors Flle YELLOW COPY/Homeowner � �� O :. O ���� =� CITY of ORONO ���� 1a! ��, 1��� ?r '�'+� �'p`,�,'��`�� ,�ti Municipal Offices �� IE�'�,�,�-�'�::�� 9�,,,<�r��,O¢.�G Street Address: Mailing Address: �,'gH 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 Owner: ( � �i7 ��� Address:4555 Wayzata Blvd. Permit #'s:6156 Dates:l0/22/80 Contractors:Gerry Robinson (This is [�], an existing system [ ] new construction) SYSTEM COMPLIANCE (1-3) : 2 1 Code Svstem: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. � Comuliant Svstem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance , with previous codes and is functioning properly. 3 Non-Compliant Svstem: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level �} has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or (�. were not confirmed to be watertight by the licensed pumping contractor. If the tanka were not confirmed to be watertight, this classification is subject to revision.) INFIELD CONDITION 11-14 : 11 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (svstem aae and condition soils etc ) : medium CONIMENTS: i�-�� � —�Date of Inspection Sep ic System Insp ctor Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telep6one (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATMENT � � INSPECTION REPORT '�t' Gti �9kESH.a�'� Owner: l�IG(� ��dV"1 Address: Y'���1 � �Q'V21�.(4 �/� Permit �'s: Dates:_�Q-�O -R(� Contractors: ,T YK/ C�b1�LSSC�I�\ City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �. an existing system [ ] neW construction) SYSTEM CONFORMITY C1-3): 1 ��CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the ' current City Codes, but was installed according to the code in effect at the time of installation, and Which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 ��NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting so�l characteristics. (The limiting soil characteristic � has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accunulation in tanks indicates they should be punped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. 9 inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each � tank at next pumpout. If tanks have not been pumped out with�n the last three years, they should be punped out now. Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). If tanks have not been puriped out within the last three years, they should be punped out now. DRAINFIELD CONDITION (17-14): Dr field inspection indicates: �Drainfield is dry, no surfacing evident. T� Sane evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector imnediately. Repairs must be completed Within 90 days. 14 Drainfield extent and condition unknoWn. LIMITING S1TE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table.etc.): ��j���i�,�'"� ! COMM NTS: � '� r Date of Inspection p ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properlyi but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system location and pumping records. WHITE COPY/tnspectors File YELLOW COPY/Homeowner On the North Shore o f Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay,MN 55323 473-7357 OWNER �/�C� o� ��Jn��' ADDRESS ZATdr • PERMIT NO.'S. �11��� DATES I���a�d CONTRACTORS �L�� City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address h�been inspected and appears to fali into the category checked below. (This is � an existing system ❑ new conatruction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accorda�ce with previous codea.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Dces not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction ot location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) �an,k_,/"nspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not J�Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump. have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulatio� in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to e�iminate surface discharge, ❑ Drainfield is seturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection'risers (4"dia,pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potentiat for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) O Adequate �High water table ❑ Low �Fair Lot size �Medium O Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate � Drainage �System is causing visible surface disc arge. COMMENTS: L �-9--�j Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report dces not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner ,=-----_._ � � O � �` 1r� O . O\\`� � � � CITY of OIiONO i `�, � : �,!, � : > ,,.8 �,; , � �;' � � , ��, Municipal Offices `\ � �' � � `\' G " Street Address: Mailing Address: ��`9 1�'E$x Q'�'� 2 7 5 0 Kelley Parkway P.O. Box 66 ��= -._. Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Current Owner of Address `'� S S� (�A�I 2�1TA �t vp City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the lc�own components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes _ _ No �~ If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for � legal action. - - System Identified as Non-Compliant Yes No � .. If yes, system must be brought into compliance by: December 31,2007 December 31,2010 Other Se�t�c.Tank(s „ ump out Needed Yes � _ ....___. .N� . _.,-. _ . . _ The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every tTiree ear"s.�City records�indieate the tank(s) were last pumped out on . �' (� �� . The tank(s) should be cleaned through the manhole and not through the inspection pipes, this"allows for proper'cleaning: Comments: . . ... Inspecto , ��-r''�.�G. .�t�� Date of Inspection � � ^� S - , . .. . Telephone(952)249-4600 • Fax(952)249-461h www.ci.orono.mn.us