Loading...
HomeMy WebLinkAboutseptic info o��� � � . � ,: o o��,, 'f` C ITY of ORONO �' ,...;;;r,� . .. � �?�, . `'' .� � ' . �: �`�f. .,,G. ' ,,` ��C,, . Municipal Offices �� ;��..;�,.. ; .';,, � , ..�. �:;` �;t;,� G Street Address: q Sa-a4 q—y 60 � Mailing Address: �'9x��p'4�'�' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal B , MN 55323-0066 6 S��rg �i�11 � To Current Owner: Address: � � City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYST'EM CONFORMITY (1-3): � 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of[he current Orono Municipal Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an inuninent threat to public health or safety. U "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may or may not meet all the location,design,or construction stand�rds of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distriburion device and the limiting soil chazacteristics. TANK CONDITION(5-7): � Tank inspection indicates: QPumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped �l'3�0��'4 ). Make sure seatic tanks are pumped throueh manhole and not throu¢h white inspection pines. This allows for the aroaer cleaning Keep water softner and iron filter dischar¢e out of septic svstem to prolons life of drainfield. Ask aumaer to test alarm float to verifv alarm is still workine in vour house The alarm warns owner that septage is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. D INFIELD CONDITION 8-10 : 2� 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMEN S: I,S�.rG,-��4� �S rd� t o�-�1,�,�r- d-- �y l� b� �'��lc�c�� �–� �2=�1– Zo�7, � � —�'-8� �� / �-�'�� Date of Inspection Matt Bolterman - Septic System [nspector votc: ln the event tha[this inspection report is used to satisti`the requirements for a mortgaee or other transfer of propert}. be ad��ised that this repurt do�s nui ��uarantee or certitj' that an e.�istine spstem �ti•ill continue to Cunclion properh•, but is mereh an opinion of the adequac} of the s�stcm uncler cw-rcnt �on�itiun;based on the availablc inCorination. � o� . o ::,_ o � �A - � CITY of ORONO �,�,,,� �,� :��t���.-� �. ��` '� `b ��. � ��� ��lCr M�n?icipal OtYices � � � � � Street Addrou: Mailin� Addrosa: �EggO�' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 July 12, 2000 Frederick Winston 765 Spring Hill Road Wayzata, MN 55391 Deax Mr. Winston: An inspection of your septic system was conducted on Julv 12, 2UOU. A summary of the inspection is below. Septic Tank CondiNon 1. Pumpout needed within one yelr(last pumpout 11/12/97) The septic system is non-compliant due to a lack of a three foot separltion distance between the bottom of the drainfield to the seasonally high watertable. The three foot requirement is a State Code,not a City Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic system must be replaced by Decem6er 31, 2007. Enclosed is a list of state licensed septic contractors who �vork in Orono on a regulaz basis. Also enclosed is a fact sheet explaining how a septic system functions properly. Finally, an as-built drawing is enclosed that shows the approximate location of the septic system. If you have any questions regarding this report, please contact me at the Ciri� Offices at 249-4600. Res ectful , Chris Pence On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the reyuirements tiir a m��rt�;:ige or other transfer of property,be advised that this report does no guarantee or certify the esisting s}�stem will cuntinue to function properly,but is merely an opinion of the adequacy af the system under current conditions bascd un the available information This report must be kept on the premises with the system lucatiun and pumping records. Telephone(952)249-4600 • Fax(952)249-4616 www ci.orono.mn.us �- ,�0� /O O - � , !''� CITY of ORONU �`�t �, - ,,�, ;y " l�r ' Municipal Offices �, ' , .. a 'ti ����� ���_�� '�`'���.�� Street Addross: � � Mailin� Address: �'�'EggOg' 2150 Kelley Parkway P.O. Box 66 � Orono, MN 55356 Crystal Bay, MN 55323-0066 r Owner: ��P� �j� � Address: 765 SprinQ Hill Rd. Permit #'s: 3135 Dates: 6/1/72 Contractors: Sullivan (This is [�] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. n Non-Compliant System: System may or may not meet current City standards for design, U construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (Tha saturated soil level is. [�j or is not [ ] idmntified uader this septic systesa. If the saturated soil level is aot idantified, this classificatioa is subject to ravision.) TANK CONDITION (5-9) : 6 �/ 5 Pumpout not needed at this time. �I71`'-5 � Solids accumulation in tanks indicates they should be pumped out this year:>> QI��`�'��� � System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] water tiQht or the conditioa is [X] uaknown. If the tanks are not confirmed to be aratertight, this classification is subject to ravisioa.) INFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIRL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : hiQh COMMENTS: The segtic system is non-compliant, but does not appear to pose an imminent threat to public health or safety (surface discharge or backup into the dwelling) . The system must be repaired or replaced by 12/31/2002 or within ninety days of posing an imminent threat to public health or safety, whichever comes first. - J �.-- Date of Inspection Se tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-'7357 • FAX 473-0510 CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATI�NT r�,� � INSPECTION REPORT 'C�� G~ 9kEsHo�'� �,�/I �� /�1r � Owner• / ► wl Y✓11�� Address• �• Permit �'s: Dates: fi'��� Contractors:��1�l�►1 City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (7his is � an existing system [ ] neW construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing ot the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which � is operating satisfectorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "NON-C�IFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which mey or mey not meet all the location, design, arxi construction standards of the current City Codes and which is failing for any reason; and an s stem with less than 3 feet of unsaturated soil between the distribution device and the limiting soi c ara . � l -� �(The limiting soil characteristic�has or [ ] has not been identifi atrt?iis ti . r[f t e limiting soil characteristic has not been ident ied, this classification may be subject to revision.) TANK CONDITION (5-10): � T�yc inspection indicates: (�J Pumpout not needed at this time. b Solids accunulation in tenks indicates they should be punped out this year to help prevent future problems. 7 Solids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be p�ed out within 48 hours to eliminate surface dischar$e. 9 inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next p�npout. If tanks have not been pumped out within the last three years, they should be punped out now. 10 Inspection pipe is located directly over tank batfle (does not give accurate measurement of solids accumuletion). If tanks have not been punped out within the last three years, they should be punped out now. DRAINFIELD CONDITION C11-14): D field inspection indicates: 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City [nspector immediately. Repairs must be completed Within 90 days. 14 Drainfield extent and condition unknown. LIMiTING SITE fACTORS (sloae.setbacks.etc.): � POTENTIAL fOR SYSTEM FAILURE (decends on soils,water table,etc.): /� COMMENTS: jh � � Date of Inspection e ic Sy em Inspector ��3�� r Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will contirwe to function properly� but is merely an opim on of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system locetion and p�m�ing records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner