HomeMy WebLinkAboutRe: spiral stairs /�" ��`��\? �' � V � � _�-��- _� CITY of ORONO , .�,. ' `'� �� ��'r'_'' � 1�lunicipal Offices '� �, � .��'., -� c�, `.;'�`��, ��,,��. G �� �-�!'y.,x,� Street Address: Mailing Address: �� ���kESH���� 2750 Kelley Parkway P.O. Boz 66 ��\ �-'_—�� Orono. MN 55356 Crystal Bay, MN 55323-C�66 April 13, 1995 I3ruce Bren IIomes Attn: Doug 106 South Broadway Wayzata, N1N 55391 RI?: Illegal Spiral Stairs - 625 Sprine Hill Road Dcar pou�: As you are a�vare, ttie spiral stairs installed at 625 Spring Hill Road �vas found to be in violation of the Uniform I3uilding Code Section 3306F (see enclosed copy). The stairway manufacturer argues that as a second stairs it is not required to meet Code. Uniform Building Code Section 3306f1 (also enclosed) states, "Every stairway having two or more risers serving any building or �ortion tllereof shall conform to the requirements of this section.° The stairway manufacturer also argues lhat the treacl width is close enough to the required 7'/z" at 12" from the post. 'l�he 1'ielel insPection clone by Bruce Vang found a tread width of 4'/z" measuring correctly from nosing to nosii�g of lhe tread (sce enclosure fram �Ianc�book to the Uniform Building Cocic). "I'he stair�vay manufacturer would like to include the tread width under the next step. If tread wicltli was measured in this fashion, you could build a ladder and call it a conforming stair. The stairway manufacturer has stated he would like to bring the matter to the Orono Building Cocie I3oard of Appeals. The function of the Board is to hear and decide appeals of orders, clecisions or cietei-minations macle by the Building Offieial relative to the application ancl interpretation of the Code. The Board has no authority to waive requirements of the Code. Therefore, since it is clear that the stairs does IlOC meet Cocie anci it is not a matter of interpretation, the City will not accept an application to the Board of Appeals. The Ci[y must require the stair to be removed and replaced with a stair that meets Code. A deadline of June l, 1995 has been establis(ied for compliance. If you have any questions, feel free to contact me. Sincerely, � `�'""'—- Ly Oman Building Official LO/ISv Telephone (612) 473-7357 • FAX 473-0510 Bruce Bren Homes April 13, 1995 Page 2 cc: Jeanne A. Mabusth, Building & Zoning Administrator � � Bruce L. Vang, Field Inspector Enc. Uniform Building Code Section 3306F Uniform Building Code Section 3306A Uniform Building Code Section 204 A & B Handbook to Uniform Building Code Section 3306C