, Mar. 28, 2013 1 :45PM No, 1514 P, 2
�
� V-P T�ST/NG� 11•V. Steven B. Schirmers• MPCA Cert.No. 627
951 Katydid Lane N� • St. Michael, MN 55376 • (763) 497-3566
FAX (763)497-5011
State License#394
March 20, 2013
Mark&Michelle Jahn
2805 Somerset Lane
Orono, MN 55�56
A Compliance Inspection was complet�d for the existing on-site sewage treatment
system located on this property. The system consists of 2-1250 gallon septic tanks, 1-
1250 gallon pumping chamber�a pressurized mound system with a 10'x 68' rock bed
built in 1997 for a 5 bedroom home. Soil boring#1 found mottled (redox features) at
2.3' into the orig+nal soil. Soil boring #3 found the original soil at elev_102.Q 8�the
bottom of the rock bed at elev.102.3 leaving .3' of sand below the rock bed &a 2.6`
separation from the bottam of the rock bed & redox features. Soil boring #2 found
mottled soil at 2.6 into the original soil. Soil boring#4 found the original soil at
elev.101.8&the bottom of the rock bed at elev.102.0 leaving .2' of sand below the rock
bed &a 2.8' separation from the bottom of the rock bed & redox features. This system
is classified as in compliance wifh Minnesota Chapter 7080 ruies with the 15%
reduction allowed..
The tanks were pumped by Elmer J. Peterson Co. &were found to be compliant at this
tirrte.
Nothing other than gray water(laundry, showers, etc.) human wast� &toilet tissue
should be disposed of ir�to the septic tanks. Garbage disposals are not recommended, �
due to adding more solids ��ine solids passing through to the system. Recommend to
divert iron filters out of the system, recommend to divert the water softner also if
diverting the iron filter. Excessive amounts of soaps, antibacterial soaps, cleaning
agents, shower cleaners used every shower&chlorine agents may kill #he bacteria
need�d to treat septic eftluent. Additives are not recommended. Recommend to pump
8�clean your tanks through the manhole by a certified pumper every 2 years. Check
with your pumper to set up a scheduie.
This Certificate of Compliance is no guarantee that this system will continue to function
ind finitefy.
�� �� ��
Steven B. Schirmers
1
, Mar. 28, 2013 1 ;45PM � No. l�l� P. 3
• � � �
' �. - �N(I`t�nesota Pollution ,� �Q���i�,��� {��p��tion Form
,,_,��:�,���,�
ry Control Agericy �r � Existing Subsur#ace Sev++age Tre�tment Systems
`'�, `'��:� 1
520 La�ayeCte Road North I �SST$�
5�P�u1,MN 5 51 5 5-4194 �
poc 7ype:Complrance and�rrlorcement
For local t�acking purposes:
Instruations: Inspectlon results based on Minnesota Pallutlon Cvntrol Agency(MPCA) ,
requiremenEs end ettached forms-additional 1oc$l requirements may also�pply. ,
$ubmlt completed form to Local Unit of(3ovemment(LUG)and gysb�m owner
withln 15 days
System Status
System statu$oo date(mtttlddlyyyy):
�Compltant-Certificate of Compli�nce ❑ NoncomRlian#-Notice of Noncompii�nce
(Velid for 3 years from r�eport date, urtless sho►ter Cme (See Upglade Requ7r�ments on pdge 3)
freme outffnad in l.oca!OrUlt�anca.)
Reason(s)for noncampllance(chack al!appllcable) �
[�ImpaCt on Public Health(Complrence Compon�nt #1)--fmminent ih�eat fo public heafth and safety°
�]01her Compllance Conditions(Compliance Component#3)-lmmrnent threat f+�pubfic healfh and sefety
❑7ank Integrity(Compliance Compon9nt #2)--Failing to protect groundweter
�]Othar Compllance Condltlons(Campllanc�Component#3J-�aili�g to pmf�ct groundwater
❑Soi1 Separatlon{Compllanc�e Component #4)-Fa�ling to protect groundwater
❑Operatlng permwmonitodng plan requl�ement�(Comp!lance Componenf #.5)-Noncamplfant
praperty Information Par�l 1DJk or Sec!"fwplRange: �r� . ��� .�
�roparty eddreas: ti � � �� ReaBo�ior Inspection: -.
PropertY owner: � _ Owners pftone: �
or �
pwner's represantative: � �� Represantaiive phone: ba'�-q� - o
Locel regulatory�uthority: G�-� � a�v � Regul�tory authority phone: q S a-a,�}q -�4S�Q__
Briet system desC�iption: - � -� L �`��^^� �"`� � �
Comments or recommendaUons: yl���(�;,�' �2pL`�"�`-� �s�Z.F�w ��'� � ����'��'� ��'��
, � , . .
Certifjcation
!her�by certiry that al!the necessary information hes been gathered to detenn�ne fhe Compllenoe status of this system.No
dete►minstion or futUr�systefn perfiormance has bean►1or Can be made due to unfmown catdltfona during system consfrucflon,
possible abuse of fhe system,lnadequete melnt�enence,orfuture watar useg�. i
lnspeclor name: r/ L� Ceclificati�n number: (d. '�
Busin�ss name� 5 �' � Llcs�se numbar:
lnspector slgneture: ..-•� � . Ph �ne number: �1�� f��t�?v� (o —
a or �ocall Re uired Attachments i
Necess ry Y Q �
�Soll boring logs ■SyslamlAs-buflt drawing (]�orms per fac�l ordlnance
❑Other information(list�: I
�
�rv�w.pca.s�ace.mn.us • 651-246-63�0 • 800•657•3864 • TTY 651-182•533Z or 00-657�3864 � AvAjldble tn altemative formdts
wq-w►vfsfs431 • i!?4/12
Ma r. 28, 2013 1 :45.��'6b � No, 1514 P, 4
. �'�_� �
� Proqerty add�e�ss: o�sLt��-'��'+� �-��� �ns �
_ pector Iniiials/f�ate: 5�;� -� �
1. Impatt on PubliC Health--Compliance companent#1 of 5
Com li�hce criterEs: Veriflcatton method(�):
Systam dischar�e sewage to Uie []Yee �No ❑ Searched fo�8urface.outl8t
round surFace. � Searched fnr seeping In yardJbackup In homa►s�
System dlscharge sewaqe to drain tile p Yes �No � ��$gFve ponding in soil syatem/D-bvxe�.►cj
o�surfac�waters, [] Momeownet tesGmony(See Gommenfs/�cplanetion)
$ystam CBuse sewa e backu �nto. � "BfaGc soif"above soil dispersa!system�.(�
dwelling ar establish ent. p ❑Yea �No d System r�qu(res"amgrgenc�'pumping
❑ Performed dye test
Any"yes"answ�r�bove lndlcates the syat�m is ❑ U�aple ko verify(See CommentslExplanatlon)
an Imminent Thnaat to Publ►c Health and$afety. Q Othef inethpds not I{sted(5ee CqmmenfslExplanatlonJ
Commentsl�xplanation: ,
Z. T�nk Integrftiy—Compliance compon�nt#2 of 5
Com Ifance criterta: Verification method(s):
System consists of a seepage pit, �]Yea ❑No ❑ Probed tank(s)bottom
cesspool,drywall,or leeching pit.
- �,] Examined oonstrudlon records
SeepeQe plfs meeting 7080.255Q may be ❑ �mined Taqk Entegfity Fom1(Attech)
Com lfant H aUowgd in locel ar!lrl8nce.
Sewa e t8nk s Iqak below their I� Obse►ved Ilquid levef below operating depth
9 ( ) C]1'es []Na ❑ ��mined empty(Pumped)t�nks(s)
desi ned o eratin de th.
IF yee,whlch sewage tank(s)leaks: � Probed outslde tank(s)for"blaGc soll"
Any"yes"answer above indlcates the C7 Unable to verliy(Sea Commenfs/F.xplanatfon)
system!s Falljng fa Protect Groundwater. d�her methods not iis#ed(SBe Comments�xplanetlon)
CommentslEuplanatfpn:
�a�� ���rGy�� �S��a� �i�� ��'���� ��P� �� �,�r���! �.o .
3, pther Compliance Conditfons-�Compllance c,omponent#3 of 5
a. Maintenanca hole covers are demag�d,cradced,un�ecured,nr appe&r to stnx:tural►y uneound. ❑Y�s• �No ❑Unknawn
b. Other Issues(el�hazanis,efc,)to immedlately and 8dversefy Impact public heallh or safely. ❑Yes' �No �]Unknown
�Sy�dem Is an!mminent th�at b publlc hee7th ahd safety
Explaln:
c. Sy�tem is non-protective of ground water for other Conditions�s determined by Inspedor ❑Yes• �No
'Speiem/s falling to protect g►+aundw�ster
Explsin:
www.pca.state.mn,us • 651•246•6j00 � BOQ-b57�3864 • TTY 651•z81•5332 Or 8�D-b57•3864 + Avaiiable in gtfemative formats
wq-wwl:rsa-3f . illq�r2
�
Ma r, 28. 2013 1 ;45 PM �4,''�7 . No. 1514 P, 5
. Property address: �� �a0 M G�..s�r� �'�•�\� Inspector initlals/Date: `�� ��1�r;�\�
4. Soil Separation-�compliance oomponent#4 of 5
aate of inst�llatipn: q,�;t2,-�'� p Unknvwn Veriflcatlon method(�):
Sho�landlWellhead p�obectlonl�ood 9everage �Yes �Na 5ot1 obsarvatfon do@s not explre.Previous aoll
Lodginp7 obse�va6Ans by two independent partles ero strfircient,
Com Iiance crlt�ri�: unless s;te conditrons have been altared orlacal �
requit�ments di8'er.
�'orsystems bullt prlar(o Apri11, 1�96, and []Yes ❑No
not locatedln Shoreland or Wellhead � Conducted soil obsarygtion(s)(Attaich boring rogs)
ProtecKon Rr�a ornat servfng a foocl, ❑ Two ptevious verific8tions(Attach bannglogs)
beve►age orlodging eshablishment:
�] Not applicabf�(MoJding tank(s),no dretnRefd)
brainReld hes at lesst a iwa�foot verilcal [J Unabl�to ver{ty(Saa Gammanta/�xp/anaNat)
separation d�stanoe from periodlcally
saturated soil or bedrock. ❑ Other(See CommB»ts�cpranation)
Non-perfarmance systems buJlt Apri11, �Yes C]Na CommentslF,xplanation:
1996,0�Iat9r pr fOr non-pe►fprtnenGe ��,,�� �5�p
systems located in Shan�land or WeUhead
Profectian AreaB pr serving a fpod, T�-1����}_
beverage,orlodgingestebllshment:
Drainfield has a three-foot vettical
separation disiance from perfodlcalfy
saturated soil or bedrock."
°Eycper�mental", "Othe�', ar "Perfo»nance" � p Yes ❑No Indicate de ths oT elevgtions
sysrems durit underpre-2ooa Rures;rype iv � r ��a��,�:,:�'s�.��
ar V systems buAt under 2008 Rules(7080. A, eottom af distnbutlon media s,,fi,"4 0. ,� .,,��s a�.•s;,
2350 or 7080.2a00 (Advgnced Inspector 5�,+�, . a,��
1.Icense requl�d) B. Periodicell sakuratet!solUbedrocic ��,+a - �..G,
Drafnfield meets the designed vertical ��' 1 q�3 a.�e �
separation di�tanc�from periodiC�ily C. S stem se aration v a+ a,,
seturated soil ot bedroCk. .,y�, m�r��wo4�-4
D. R ulred cam IianCe se aration' 3•� ���X�)r.�,a�,�
Any"no"�nswer above indlca!`es the system is� "May be reduced up to 15 percant it allawed by Locef
Falling to_Protect Qroundwat�r. � ordinance. �
5, pperat9nq Permit and N9trogen �Ahp*--Cbmpl�ance camponent#5 of 5 � Nat applicabie
Is the sy�tem oparated under an Operabng Pemrit? ❑Yes ❑No If"yea",A below Is requfred
Is the systerrl required to employ e Nitrogen BMP? ❑Yes []No ff"yea'",�beiouV Is required
BM�B�sf Menayement Precffce(s)apecih'ed ln the systenl design
If the answ�er to both quesflona!s"no';thls sectlon da�s not need to be comp/eted,
Com Ilance crlterta
a. Operating Permit number: �
Wave lhe Q erat�n Permft re ul�emeMt been metl �Y�g �NO
b. Is the re uired nitro en 8MP in 18Ce and ra erl functionin ? Yes No
Any"no"answerindicates Noncomp/lance.
Upg rAde ReqUlf�iments(MJnn.Stat.§115.55)M lmmin�nt thnaat ta pu6rl�¢ealth and safefy(fTRNS)must be upgraded,replaced,or its use
dlsaon!lnued wlthln ten months ofrecelp!of thls nofhae or wlthln$shp,ter pelfod if reqWred by IoCa!errlfnance.If the sysiem!s(alling fo profect
ground wafer,the system musf be up9+aded,rBplaced,orlts use dlscatNrlu9d wiFhin ttre f7me raqulred by fxal orClinence.K en e,rlsting system
is rnn falling as dellned in lew,erxi has et►east Iwa feet of deslyn aol!sep�raflon,thBn thg syst9m rreed'not be apgr�ded,r�peired,rBpleced,or
!ta use dlsca►tlnued,nohNPthsfending sny loce!orclln8n(ag fhat Is more sbict.fi!s p�oWslon 4ogs not�ppty ro systems In���Ra ereas,
wellhead PrvtecNon Arees,or those ased In canneclion with food peire�age,and lodgn,g eslabAshmenis ea deffnep;n lew.
www.pca,state.mn.us • 651-296-6300 • 800•b57•38b4 � TTY b5]•282-5332 or 80�657-38b4 • Available ir�altemative formats
wq•wwlsrs4•3t . r�14�r1 �
Mar. 28. 2013 1 :46PM No, 1514 P, 6
' ��� T�.�TIN�� �N�. Steven B. Schirmers • MPCA Cert.No. 627
951 Katydid Lane NE • St. Michael, MN 55376 • (763)497-356B
FAX• (763)497-5011
State License#39�
LOGS OF SOIL BORINGS
Mark 8�Michelle Jahn
Z$p5 Somerset Lane
Orono, MN 55356
Borings completed on 3-18-13, with a hand bucket auger.
BORING NUMBER�Elev.102.7 - MOTTLED SOIL AT 28" into the ariginal soil - no standing
water present in boring.
0 - 8" Fill soil loam
8" - 16" Fill soil medium sand
16" - 26" Original soil very dark gray brown loam 'lOYR 3/2
2fi" - 30" Dark brown clay loam 10YR 3/4
30" - 44" Yellowish brown clay loam 10YR 5/4
44" - 50" Yellowish brown clay laam 10YR 5/6-
distinct mottles 10YR 7/1, 10YR 6/8
BORING NUMBER 2- EIev.102.5-MOTTLED SOIL AT 31" into the ariginal soil - no standing
water present in the boring.
0 - 13" Fil1 soil ioam
13" - 15" Fill soil medium sand
15" - 22" Origin�l soil very dark gray brown loam 10YR 3/2
22" - 28" Dark brown clay loam 10YR 3/4
28" - 40" Yellowish brown clay loam 10YR 5/6
40" - 46" Yellowish brown loam 10YR 5/6
46" - 54" Yellowish brown Io�m 10YR 5/6 -
distinct motles 10YR 7/1, 10YR 5/6
Ma r. 28. 2013 1 ;4b�PM No. 1514 P, 1 �
soil borings conYd.
B4R1NG NUMBER 3- EIev.104.0 -through the mound.
0 - 10" Fill soil loam
10" - 27" Fill soii medium sand
27" - 32" Original soil dark brown loam 10YR 312
BORING NUMBER 4-EIev.103.8-through the mound.
0 - 10" Fill soil loam
10" - 26" Fill �oil medium sand
26" - 32" Original soil dark brown loam 10YR 3/2
2
Mar, 28. 2013 1 :46PM No. 1514 P. 8
"�'ank Re�vi-�
Date: M1�arch'12,2013
�lmer�. �`eterson Co.
5921 bagtxe Ave.
Delano, MN ,5.53�8
PhA17le 7fi3-972-2420
Fax r6S-912-72�7
n�IPCA T�icense# �19
Mark and Michefle J�fin
2805 SomerSet Lane '
Long Lake,MN 55356
Baf�leS:( QN OFF
��
Tank Capaciey: �-��oo��uon Tan►cs
# of Tanlzs: 3
Type o4'Tanks: Concrete
Gal.lons Pumped.� 2500
Manholes to Grade: YES Nn
Comment,s:
On Marchl2,2a13,EEtt1�p J_Pet��;bri Co, purrip�d tariks. No cr�cks bP w�te�'ieaks�t t�ist ti'tr►e.
NOT�:This xs only a c���lc rc�ort. Tl�is xs iyot a corz�pliance insj�ection for peint of sr�le nor daes
it re:plec�a compliance inspection.
License# 21J
Mar. 28. 2013 1 :46PM No, 1514 P. 9
Parcel number: � System status; �Gomplfant ❑Noncompliant
(as detertnlned 6y this(onn)
Tank Int�grity and Safety C4mpliance- Compl;ance lnspection Form fvrExisfing S57'S
Compfiance Issue #2 of 4
Date ot observation� 3��y�3 Reason for observation_ point of 5ale
This form expires on(three years): 3112/18
Compliance questionslcriCcrie:(Required} Yerification Method�`:(Optional}
Check the e �afe box (Check fhe appropriete box)
boes ihe system consist of a seepage ptt•, ❑Yes �I Na 0 probed tank bottom
cess ool d ell or laachin it?
bo any sewage tank(s)leak below their ❑Yes �NO ❑. �bservad lrnv liquid level
desi�ned.°pe-ratin�d�th? ❑ Examined conshuction records
If yes,identify which d EXamined empty(pumpsd)tank
sewage tank leak�.
- ❑ Probed auiside tank for"black soil`
Any"ye8"an8wer!►idlCeteB tRBt the syslam is failing ro prolect � pressure/vacuUm chack
ground watar.
❑ Other.
` 5eepege pits meefiing 7080.2550 may be compfiant if allowed
in ordinance by local permitting authorily.
"No stenderd p�otoco/exisls.This/isf is not exheuslive,In
sequenfraf order,nor does if indicefe which combinetions
ars necesaary to make thla dat�mlU►ptlon.
Safety Check
1. Are mainte�ance hole cover�damaged,aacked,or appeared to be struch�ralhr unsound? ❑Yes• 0 No
2. Ware rttafntenance hole covers replaced in a sacu�ed manner(0.q.,screw�replaced)? �Yes ❑No"
3. Was secondary access restraint preserrt(saFety pan,second cover,or safety netbngl—highly recammenQed, ❑Yes �No
4. Are vthe�safetylhealth ie9ue presenCl ❑Yes" �No
Explain'
•System is an fmmMent threat to publJc healrir and sefety.
C,ertificatlon
Thls 9erm is to be completed and att�ched to the SummaYy Form of the Miqnespte Po1lu�on Control Agency's(M PCA)Compllance
Inspacnon Form fer�xfsttng Subsurface Sewage Treatmant 3ystems.Observdtio�s,intarpret�tlons,end conclusiens must be
completed by an Inepectnr,ma�ncainer,or earvice provlder.Completed fo�m must be submittad to the local unK of government within
15 days.
Propelty oWner name(s): ��rli adq IIbllchellA Jahn
Property address: 2805 Somerset Lano Long Laka,MN 55366(Orono)
Properry ownePs eddress(ddifferent�: _
County; Hennepin P�operty owner phone: 612-850-951U Mark
1 heieby certrfy tliaf 1 peisorially mede 1He o6serv8tioris,inferpfetaNdhs,and coriclu�iaR�r6pOrfeal on t1fi�for/n end that they 8�e
correcL
Name: James Braegelmann Cectificaiion number: ^
Business fiCense rlame a�d number, Elmer J.Peterson Co_ Licerls�219 0�
Narile of Idc�l u cvElnment�
Signature; ���� �_._ Date: ��2�13
www.pca. e.mn.us • 651-296•6340 . 800-657-3854 • TTY 651•282•533�or BOD•557•3864 . AYaitable In alternatfve formats
wq-ww�sts4-31 • Al Z4109 Page]of 8
V�ar 28. 2013 1:46PM \ No, 1514 P. 10
\
, \
�
. �
S
e \
��
P S�
�O `
S� �
�
� ` � � ,
o,� �
�
�
,
4,� `�' � .
.. .� y �
� y�.
�
� , � -
r
� �
�6'
�� �� /�_ w � �°
- � �� � �
" � �>�� $
� �
��T x�6 '� X� P�."� „
r.
� �W� 4' G
;" ro
o`
N�
� y�� �� �I I�I I
M �G '� A cn
x � �Y ,p����, Z �� �
"d;� *, �d �.�,« R x
� S �Q 'i��; I
or°� a,j� � I�j�C�p =
K j� I�'G �''F LC , 9' �
� ���' ��, �p .�
� 'v``� a
��� i ��,Ir, ��
a � �� .To
y a r !
�
C
� ��i` c �� ��
.� Z � �� �O I r�� IC� r
�n ^ ��� '` '�i � � _L- �
'�G � �- .
� �� � " . i �_
� � ;� � �� ��, � � I Yw������
1�-, � tu '° �'� ,� �i 9 I � I+�'=ia
G r-� n -1 i� ,. (
�� �i • � G o� � � a Q �
b �'
� �
� � � � �, # � � � �I
�; ; � " �. n � � �
Z o �
� ��� � .7� a W � � . � �
"1 '�� Q+ F� ��"
� ` n . � � � ��jy O � � .
01 1 {7 Y p.}5 � �
Q1 N W`{ &
� � � w
�� �
m n
N (p
� °�
o : o
=��Y.:.��- �ITY of OR4N4
�,aj ',;����'°T''���- � '�'
''� �� ' } � �C, / Municipal Offices
,� �����f .���,..':'�;:-C�`� � ,
���� ���'�'�%'��'��-��'��' G�`i Street Address: �i5a'a4q"y6o o Mailing Address:
;\, :...�.s�. .,,c� .� i
�`���`9 'f�' '4�' ��� 2750 Kelley Parkway P.O. Box 66
.• 1`�ESI10 ;%;
��----%' Orono, MN 55356 Crystal Bay, MN 55323•0066
To Cuixent Owner: Address:^,��St' � ��:rof� �'�`�<,. +-
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY f 1-3): �
1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An LSTS whicli does not meet all the location,design and construcdon standards of the current Orono �
Municipal Code but does meet the three foot separation requirement or rivo foot requirement for systems installed 1996 or earlier,and
which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an LSTS located within a designated 100-yeaz flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any �
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION l5-7): �
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure septic tanks are aumaed throush manhole and not throush white inspection piaes. This allows for the uroaer
cleanins Keea�vater softner and iron tilter discharee out of septic svstem to arolone life of draintield. Ask aumper to test
alarm float to verifv alarm is still working in vour house. The alarm warns owner that septase is about to backun into basement.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tanic. If
tanlcs have not been pumped out within the last three years,they should be pumped out no�v.
DRAINFIELD CONDITION(8-10):c�
8 Drainfield is dry,no surfacing evident. " " '
9 Some evidence of surfacing,not criticai yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact tlie City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS:
�' :��"'' �
�
Date of Inspection Septic S��stem Inspector
�°� �
o. ::,.. , o
����_ � - CITY o� ORONO
� � �;r�-;�.
� �,, �;, �", Municipal Otfices
� f� ` , �•G~ Straet Address: Mailint Addreas:
«.. �
'��,�F�j�'�y
�$�xp�' 2750 Kelley Parkway P.O. Box 66
4rono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: a a b� S8i"`�' Sti� 1'Sne--
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY 1-3 : �
1 "CODE SYSTEM"An ISTS which meets al1 the location,design and cotutruction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" M ISTS which dces not mcet all the location,design and construction standards of the current Orono Municipal
Code but dces m�t the ttu�ee foot separation requirement or two Eoot requirement for systems installed 1996 or eartier,end which is not failing or
an immi�nt threaz to public health or safety.
3 'T10N-CONiPLIAIVT SYSTEM" A prohibited ISTS;�ISTS located within a designated 100-year flood plain,any ISTS which may
or may rat mat all the locetion,design,or cmnstrudion standards of the current Orono Municipal Code and which is failing 6or arry rea�n;�d
any ISTS with less than U�ree feet of unsaturated soil or sand between the distribution device end the limiting soil characteristics.
TANK CONDTTION(5-7): S
inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped �0"�-0� ).
Make sure septic tanks are pamaed throush manhole and not through white insuection uiues. This allows for the
uroaer cleaning. Keep water softner and iron filter dischar¢e out of se�tic svstem.
_ 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last thr�years,they should be pumped out now.
DRAINFIELD CONDITION(8-101: �
8 'nfield is dry,no surfacing evident.
Some evidence of surfacing,not critical yet.
i0 Drainfield is saturated and visibly dischazging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
co�rrrs: r�o v�� �.� ��p�-� -��`� toa� o _
q=�-6'� ��`�- �
Date of Iaspection Matt Boltennan- Septic System Inspector
NoCe:In the eveat Watthis ia4pection rzport is used to satisfy the requi�emeats for a nwrtgage or other transFer of property,be advised tl►at this�epoit does not guacan�ee
or�xrtify Wat a►cxisting sysbem will�ntin�u to function properlY>b�t is merely�opinion oftl�e adequmcy of du system under a�rrent aonditioos based ai the available
informati�.
1�ephone(952)249-4G00 • Fax(952)2A9-4616
�vww.ci.orono.ma�
� � °� .
� o ���. o � �
� � � CITY
,���� �- ,, of �RONO
,� �� r:�:
� 1�� �ti�� ti
is�.;y�'�.�,; 'ti, . . Munic�pal Offices
� "�%`�`�" ��� G Street Address: .
.q �:��i,• g,'�Y Mailing Address:
. �E$�ID 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crysta( Bay, MN 55323-0066
Owner: ��('l� �� �� c� Address:_ ��4 5 S d r���Se—?- l� .
Ciry Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs.
The on-site se�vage ueatment system at the above address has been inspected and appeazs to fall into the categories checked belaw.
YSTEM CONFORMITY 1-3 : ( '
1 "CODE SYSTEM" An ISTS which meetc ali the location�design and coruttuction standards of the cutrent Orono bfunicipal Code.
2 "CO�LIANT SYSTEM" An ISTS which doa not meet ail the location,design and consttuction standards of the cucreut prono I�funicipal
Code but does meet the ttuee foot separation requirement,s,nd which u not failing or an immiae�threat to public haalth ot safety.
3 "NON-CONIPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plaiq any ISTS which may
or may not meet all the locatioq design,or construction scandards of the cucrent Orono Municipal Coda and which is failiag for any reason;and
any ISTS with less than three feet of unsaturated soil or sand betwern the distnbution device and the limitin�§oil characteristics.
TANK CONDITION(5-101: ,� �
Tank inspection indicates: .• •
( � \ Pumpout not neaded at this time.
�J �.`''l-�0
6 Tank must be pumped out this year (city code requua tanks to be pumped out every 3 yeazs. Tank was last pumpad � �' �,
7 Solids ac�vmulation in tanks is at a critical a critical lavaL Tanks should be pumpad out av soon bs possible.
$ System is discharging to the surfa�ro. Tanks must ba pumped out within 48 hours to eliminate surface dischsrge.
9 Inspacdon riurs missing-tanks could not be inspecced. Inspection risars(4"dia.pipe)must be installed in each tank at naxt pumpout If tanks
have nut been pumped out within the(ast three yeats,they should be pumped out now.
10 Inspn:tiun pipr is located direcUy over tanlc ba�le(does not give accurate maasurement of solidt accumulstion). If tanks have not bern pumped
out withirt the l�st three yeazs,they should be pumped out no�v.
D IELD CONDITION 11-14 : I�
1 Dta�eld'u dry,no surfacing evidcat
Soma e�ndenca of surfacug,not eritica!yet � . ' ' •
13 DrainField'u ssturstad and visib(y dischacging untreated e@lurnt to the surface. Contad the City Inspactor immediatety.Repairs must be
eompleted«ithin 90 days.
1� Dra'�ntield aatenc and eondition unknown.
co�rrrs: 5 yS�� \ oDKS �
� � "`� -� � . vr�
Date of Inspection Se t�c S �
p' ystem Inspector
Note: Ia the evaU that this iaspection report is used W satisfy the tequirement�far a mortgage or other transfa of property,be advised that this repeR does not guarantee
or eectify that an e�sting systam will contiaue to functioa properly,but is merely aa opinion of the adequary of the tystem under cuaeat eoaditions baud oa the available
infocrostioa
�
0,�. �OPY
O O
�
,�r.�; � CITY of ORONO
15r Municipal Offices
��,� ' G~ Street Address: Mailing Address:
'9JtEggOg'� 2150 Kelley Parkway P.O. Box 66
� ,,�,_...,
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: ���/� ��,�� ���\ Address: 2805 Somerset Ln.
Permit #'s: 9105 Dates: 6/18/97 Contractors: Patnode Bros.
(This is [�] an existing system [ ] new construction) .
STEM COMPLIANCE (1-3) : 1
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level is [�] or is not [ ] identified under this septic system. If the
saturated soil level is not identified, this classification is subject to revision.)
NK CONDITION (5-9) : 5
5 Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are [� ] or are not [ ] water tight or the condition is [ ] unknown. If the tanks
are not confirm�d�to be watertight, this classification is subject to revision.)
INFIELD CONDITION (11-14) : 11
1 Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low
COMMENTS:
�� �n �
Date of Inspectio Sep 'c System Insp ctor
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone(612)249-4600 • Fax(612)249-4616
� O�
O :� O
��� CITY of ORONO
�,�'► "� ��'�� ,�lS� Municipal Offices
� Y � V
� � .�yG Street Address. Mailing Add�ess:
9�C'EggOg' 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
Owner: ��(/Y _ � C JJ�Cr( �.(�'� Address: 2805 Somerset Ln.
Permit #'s: 9105 Dates: 6/18/97 Contractors: Patnode Bros.
(This is [ ] an existing system [� new construction) .
SYSTEM COMPLIANCE (1-3) : 1
�Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturatad soil level [x] has or [ ] has not baen idantified at this time. If the
saturated soil level has not been identified, this classification is subject to revision.)
ANK CONDITION (5-9) : 5
Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(DurinQ the last septic tank Maintenance Pu�out tha tanks [ ware or [ ] were not confirmed
to be watertiQht by the licensad pusqpiag contractor. If he tanks were not confirmed to be
watartiQht, this classification is subject to revision.)
INFIELD CONDITION (11-14) : 11
1 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (svstem age and condition, soils etc. ) : low
COMMENTS:
��a��
Date of Inspection Sept System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510