Loading...
HomeMy WebLinkAboutseptic info ' � �' .SEPTIC .SY.STEM INVENTORY Address: 125 Smith Ave. PID: 02-117-23 21 0017 Building Type: residence #BRs/GPD: 3 #Systems 1 Units Billed 1 Permit#: 2104, 8515 Date of Permit: 5/7/69, 6/11/8 Installer: Day Plbg., E. J. Peterson System Type standard trench Experimental: no Appliances lndry SYSTEM CONDITION Conformity: 3 Tank Condition: 9 DF condition: 11 Failure Pot: low SEPTIC TANKS Material: concrete block Capacity: 750, 750, 800 Setback to Bldg: 25 Cesspool: unknown DRAINFIELD Length of Lines 330 #Lines: 4 Trench Width: 2-3 Treatment Area: 900 Type of Filter rock Soil Boring: yes Tile Size: 4 Under Tile 12 Perc Rate: 31 Setback DF-Bldg: 40 DF Ht above Wt: 2.2 Soil Type: sandy clay loam Limitations: water table WELL DATA Setbacks - Well-Tanks: 75 Well-DF: 75 Report in File: Pump Type: Depth: Diameter: Method: INSPECTION RECORD PUMPO UT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 7/21/81 no surfacing 2 6/1/86 1500 6/20/86 added pump tank (800 ga1),DF (900 s� 2 1 U19/92 1500 10/23/86 elec. cable in 20'of lst trench,may have b 2 7/14/88 no surfacing 2 10/1/90 no surfacing-pump tanks 2 4/21/94 no surfacing 2 7/13/98 non-compliant-no repair required,pump ta 3 — �� �l � -Se �� �6 P�'�P � � ��n r�=� ��{ /3C " �' c � � I, � , ,�.. � .. 1��" �'��� ��. � 3s� ,�.�I � ; ` �r�rD �; I � ��. �y��,�'� ,� L-'• , . � - . "� ' cy y� , � �� i �, , �E z (0 3'�o S!'!o � , s � . �:�f���� ��� ���( C7'(y f "� ''� '( b '� � f� ,i•�C �.� , C_....\' _ __ D$ �� i; � lo • � ; ~ _—�� a.�' �x� ,�t �- � ' '* �� � �5.1 I i � �:,�.r"4 R-;� sxz.s�- -� - � 65'xZ / '` � ( C�'X2.5�« ' } �O x �.�, 20�x z,S'� � ��,�r�r' �o XZ,s'k .�y�/�K !2:n2.S�1 ---. I .�SX2.��± — _ ---- _ P��'��r�-1 Lr,���..r�P�ax.� ---__' _ -- - _ ����� '---'�.. �/tArnr�1ELD IS i7owNHI�L ��or� ���tr�n,G �Jw�Q-c�OLE \ ��� O O ��=�R ��� CITY of ORONO � _�r�� �' � � �x�� J�`-� :�;:,�,�;= �,�� = F, Municipal Ot'hfices , , �?�`� 'ti \, � � ?7�;`�i�'',�G Street Address: Mailin�Addreu: ,_. '�y�"Hp�" 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 Owner: �vt� l,!{ � �C� Address: ia5 S�aith 1►ve. Permit #'s: 2104, 15 Dates: 5/7/69, 6/11/86 Contractors: Day P1bQ., E. J. Petersoa Co. (This is �j an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating proper7y. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous Q codes and is functioning properly. Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturat�d soil level ia [� or is not [ ] identified uader this saptic systam. Ig the saturated soil level is aot idaatifiwd, this classificatioa is subject to revisioa.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. Q Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, ,t�he �should be pumped out now. 10 One or more tanks are cesspools, which means the sept� sy�i 'is-non-co�iant. (The taaks are [ ] or are not ( ] water tiQht or th� coaditioa is �, unkaawa. If the taaks are aot conffrmed to be watertiQht, this clasailicatioa is subject to revisioa.) INFIELD CONDITION (11-14) : 11 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low COI�Il�NTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 2.2 feet and the system is non-compliant. City Codes do not require repair or replacement of the septic system at this time. -�-->3 q� � Date of Inspection • Sept System Inspector Note: In the event that this inspection report is used to satisfy the requi;ements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Tekphone (612) 473-7337 • FAX 473-0510 CITY OF ORONO �O� M�micipal Offices O O Post Office eox 66 Crystal Bay, MN 55323-0066 � � ON—SITI� 88WAGE 'I'REA'1'l�NT � h INSPECTION REPORT ti ��9kESH.��'�G Owner• ��Address• ���)7/\ �. Permit #�'s: * atea: ��Y�9 Contractors: � Y/LX�• City ordinence nu�er 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked betow. (This is ,�!-an existing system [ ] new construction> SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, end which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "N�I-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year ftoodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic �C1 has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi'fied, this classification may be subject to revision.) TANK CONDITION CS-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed �n each tank at next puipout. If tanks have not been pun�ed out uithin the last three years, they should be p�mped out now. � Inspection pipe is located directly over tank beffle (does not give accurate measurement of solids accunulation). � If tanks have �wt been punped out wit in the last three vears. they should be punped out now. DRAINFIELD CONDITION (11-14): Drp�i,�field inspection indicetes: 11Y Drainfield is dry, no surfacinp evident. `12 Same evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. IIMITING SITE FACTORS Csloae,setbecks,etc.): POTENTIAL FOR SYSTEM FAILURE (deoends on soils.water table.etc.): � COMMENTS: Date o Inspection S p c y tem Inspector Note: ln the event thet this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properlyi but is merely an opinion of the adequacy of the system under current conditions based on the available informat�on. This report must be kept on the premises with the system lxetion and punping records. WHITE COPY/Inspectors Flle YELLOW COPY/Homeowner