HomeMy WebLinkAboutseptic info ' � � ,SEPTIC SY.STEM INVENTORY Address: 115 Smith Ave. PID: 02-117-23 21 0016 Building Type: residence #BRs/GPD: 3 #Systems 1 Units Billed 1 Permit#: 8176 Date of Permit: 11/8/85 Installer. Halstad Const. System Type standard trench Experimental: no Appliances lndry SYSTEM CONDITION Conformity: 3 Tank Condition: 6 DF condition: 11 Failure Pot: low SEPTIC TANKS Material: precast concrete Capacity: 1000, 1000 Setback to Bldg: 10 Cesspool: no DRAINFIELD Length of Lines 180 #Lines: 4 Trench Width: 4 Treatment Area: 720 Type of Filter rock Soil Boring: yes Tile Size: 4 Under Tile 12 Perc Rate: 27 Setback DF-Bldg: 20 DF Ht above Wt: .3 Soil Type: loam,clay loam Limitations: water table WELL DATA Setbacks - Well-Tanks: 50 Well-DF: 50 Report in File: Pump Type: Depth: Diameter: Method: INSPECTION RECORD P UMPO UT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 11/8/85 replacement installation 1 9/1/90 1600 9/18/87 no surfacing 1 1/26/94 500 10/1/90 no surfacing 1 4/21/94 no surfacing 1 7/13/98 non-compliant-repair by 12/31/2008,pum 3 �p�rr�c�PC� � SP W� � �/ � ��l� l�-cc %� �fx�� � � a�'� �1 ���5 ��I � I I T J x I�' �XS7 _ __� r � - - - - - i �, , � ,hXsz -- - - - -- -i � , q I i . � M ° � � Ik �' -� � `� � � � ; � i � � � �j �_ �,. ' ` �� i � I�, �' ���, _.� o � � i z `� ,��. � � � o�,� I , ��' � � � s � _ f � ' � � _ — _ _ - , � -� , - _ _ - i � o I , � ������c � � : I � ' /l� � -- - - - - - - ' �, -� ( _ . . % °� 0 0 -,�i� ��- CITY of ORONO , �-�.� � , j��, � � �� t,�; .���,�.,� ' Municipat Offices %����.��� �ih' t-_ � -.�,���¢.�, Street Addroas. Ma11inQ Addross: �`�'Eg'HO 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: � Y Address: 115 Smith 11va. Permit #'s: 8176 Dates: 11/8/85 Contractors: Halstad Const. (This is [�] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (Tha saturatad soil level is ( or is aot [ ] identifi.d uader thia aeptic systeat. If tha saturated soil lavml is aot ident fied, this classification is subject to revisioa.) TANK CONDITION (5-9) : 6 5 Pumpout not needed at this time. Tj Solids accumulation in tanks indicates they should be pumped out this year. �/ System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or ar• aot [ ] water tiQht or ths coaditioa is [�] unkaaaa. If the taaks are not coafirmed to bw watertiQht, this classification ia subject to revisioa.) D INFIELD CONDITION (11-14) : il Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low CONIIyiENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0.3 feet and the system is non-compliant. Repair or replacement of the septic system is required by 12/31/2008. i �-I��'� Date�Inspection Se ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Tdephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(iE TREATl�1T � �H. INSPECTION REPORT ��9kEsHa4'�G Owner• Address• Permit #�'s: O Dates: — /�/�5� Contractors: � City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to tall into the category checked below. (This is (�.an existing system [ ] new construction) SYSTEM COMFORMtTY (1-3): � "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input witha�t discharging any poltutants into grou� or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into gro�d or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic �}. has or [ ] has not been identified at this time. if the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): � T,dnk inspection indicates: l5/ Punpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pun�ed out this year to help prevent future problems. 7 Solids accunutation in tanks is at a critical level. Tanks should be punped out as soon as possible. 8 System is discharging to the surfece. Tanks must be punped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next rxnpout. If tanks have not been punped out within the last three years, they should be punped out now. 10 Inspection pipe is located directly over tank baffle (dces not give accurate measurement of solids accunulation). If tanks have not been p�mped out within the last three years, they should be puiped out now. DRAINFIELD CONDITION C11-14): Dr,�,nfield inspection indicates: (1y+ Drainfield is dry, no surfacing evident. 'T2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition �known. LIMITING S1TE FACTORS (sloae.setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (deoends on soits.water table,etc.): %h� -Jcr�� COMMENTS: Da e of Inspection p ic System Inspector Note: In the event that this inspection report is used to satisfy the rec�irements for a mortgage or other transfer ot property, be advised that this report does not guarantee or certify that an existing system will continue to f�ction properly� but is merely an opim on of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system locetion and punping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner