Loading...
HomeMy WebLinkAboutseptic info � - ' SEPTIC SYSTEM INVENTOR Y --- -- --- - --- _ -- - _--- - - --_ __- - - --_ . Address: 40 Smith Ave. PID: 02-117-23 21 0002 Bui�ding Typ residence #BRs/GPD: 2 #Systems 1 Units Billed 1 Permit#: none Date of Permit: Installer: owner? System Type wide trench Experimental: no Appliances SYSTEM CONDITION Conformity: 3 Tank Condition: 6 DF condition: 12 Failure Pot: high SEPTIC TANKS Material: concrete block Capacity: 800 , Setback to Bldg: 40 Cesspool: unknown DRAINFIELD Length of Lines 200 # Lines: 1 Trench Width: 6 Treatment Area: 1000 Type of Filter rock Soil Boring: yes Tile Size: Under Tile Perc Rate: Setback DF-Bldg: 100 DF Ht above Wt: 0 Soil Type: Limitations: water table WELL DATA Setbacks - Well-Tanks: 50 Well-DF: 100 Report in File yes Pump Type: subm. Depth: 112 Diameter: 4 Method: drilled INSPECTION RECORD PUMPOUT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 8/13/81 no surfacing 2 5/1/86 1200 7/30/86 no surfacing 2 4/3/92 800 7/14/88 no surfacing 2 4/2/93 800 9/27/90 no surfacing-need risers,pump tanks 2 6/25/96 500 4/3/92 line cleaned between tank and drop box 2 4/21/94 DF surfacing 3 12/2/97 DF surfacing-pump tanks now 3 7/13/98 non-compliant-slight surfacing,repair 12/ 3 . 7/11/00 noncompliant,connect to sewer 12/31/20 3 I/' 1/O` �(_4,�`��'�LIC1� , ll ��V.��.� i } � Srr1 r� ���-. z i . ____. ; I � � � 1 c � . /��� � � r S�l--.�e y��l � � � C �.�n �a� �C� D�3 7�p s�D U�� �i _ �9 �y ��� �o� , o 0 ; ,t �t:�_� � CITY of ORONO � ., .� :�. �� �, �;y,y��a., (� Munic3pal ofPices \,�� \�-:�Z'��=E���',�G~ Street Addrou: MaiUnQ Addross: '�'�'Hp4' 2750 Kelley Parkway P.O. Box 66 — Orono, MN 55356 Crystal Bay, MN 55323-0066 owner: _�I/�QS ��i� Address: 40 S7aith 1►ve. Permit #'s: aons Dates: Contractors: owaer? (This is [� an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous � codes and is functioning properly. Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturatwd soil lev�l is [� or is not [ ) ideati�iwd uadar this septic ayst•m. if the saturated soil laval is aot identified, this classificatioa is subject to revisioa.) TANK CONDITION (5-9) : 6 5 Pumpout not needed at this time. � Solids accumulation in tanks indicates they should be pumped out this year. System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. Zf tanks have not been pumped out within three years, they should be pumped out now. 10 one or more tanks are cesspools, which means the septic system is non-compliant. (The tanka ars [ ] or are aot [ ] water tiQht or the coadition is [� uaknowa. If the taaka sre aot coafirmed to b• wstertiQht, this classificatioa ia subjact to revision.) DRAINFIELD CONDITION (11-14) : 12 il Drainfield is dry, no surfacing evident. � Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : hiQh CONII�IENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic system is required by 12/31/2008 or within ninety days of sewage effluent discharge to the surface. 7-��-�'� Date o�-Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Tekphone (612) 473-7357 � FAX 473-0510 � °� o :� o �� CITY of ORONO �. . �,.�.�� �t� �,,�,�\��� � �`,,� ���, `; �:�' : G�lSr Municipal Offices � t��� � ¢.� SVeet Addross: MaiIInQ Address: �C'EggO 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: � ��,� ���� Address: 40 Smith Ave. Permit #'s: nona Dates: Contractors: owner? (This is [�] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous Q codes and is functioning properly. Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level [�] has or [ ] has aot been identifiad at this time. If the saturated soil level has not beea identified, this classification is subject to ravision.) TANK CONDITION (5-9) : 6 �, Pumpout not needed at this time. (6� Solids accumulation in tanks indicates they should be pumped out this year. `y System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (DurinQ the last septic tank Maiatenance Pu�out the tarilts [ ] were or [� were not confirmad to be watartiQht by the licnnsad puu�ping coatractor. If the tanks were not confirmed to ba watertight, this classification is subjact to ravision.) DRAINFIELD CONDITION (11-14) : 13 11 Drainfield is dry, no surfacing evident. � Some evidence of surfacing, not critical yet. Repair is not required at this time. ' 3 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : failin� CONIIVIENTS: The septic tanks must be pumped out as often as is necessary to prevent surface discharge of sewage until a connection to municipal sewer or a septic system replacement can be made. D��-�`� ,�- te of Inspection Sep c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (61Z) 473-7357 • FAX 473-0510 . �°� CITY OF ORONO O O Municipel Offices Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAaE TREAT!lENT INSPECTION REPORT ti Fv '�' G �9kEs8o�'� Owner• �l".Tf,��lfwbl�� Address: �71'� S/77l ft'i/1F'• � Permit #'s: Dates: '^ Contractors: ii/�K�Y�G,.Y� City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is [79. an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City Codes, end which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "Cd�iFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which mey or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any_system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ) has or � has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDiTION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be punved out this year to help prevent future problems. 7 Solids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible. � System is discharging to the surface. Tanks must be punped out uithin 48 hours to eliminate surtace dischar�e. inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe> rtwst be instelled in each tank at next purpout. If tanks have not been punped out within the last three years, they should be punped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation>. lf tanks have not been punped out within the last three years, they should be punped out now. DRAINfIELD CONDITION (11-14): � �rainfietd inspection indicates: 11 Drainfield is dry, no surfacing evident. � � Sane evidence of surfacing, not critical yet. Drainfield is saturated and visibly discharging �treated effluent to the surface. Contact the Cit Ins tor immediately. Re ' 14 Drai nfitterE�terfr a co t t t on � nown. LIMITING SITE FACTORS (sloce,setbacks.etc.): POTEN?IAL FOR SYSTEM FAILURE (decends on soils.water table.etc.): COMMENTS��—�- �, � ��' �� Date of Inspection tic S s em Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the evailable informat�on. This report must be kept on the premises with the system locstion and pu�ing records. WHITE COPYllnspectors File YELLOW COPY/Homeowner