Loading...
HomeMy WebLinkAboutseptic info _ _-o�_ �:� � � ,;��-o ��,,. �; o, �1 ;� . ��,�, ciTYo� o�oNa .,. � , �;� � `• ��C, � MunicipalOffices i � � '` G Street Address: Mailing Address: �9,kE$x04�� 2750 Kelley Parkway P.O. Boz 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 To: The Current Owner of Address �'� ,�c �� � ' �'�"� City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is kilown about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �No � If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attoniey for legal action. System Identi as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31, 2007 � December 31,2010 Other Septic Tank(s ump out Needed Yes . No The City recommends the septic tank(s) and/or lift tanl:be serviced and pumped o�it every three years. City records indicate the tank(s) were last pumped out on �� r�� . The tank(s) should be cleaned through the manhole and not tluough the inspection pipes, this allows for proper cleaning. Comments: � Insp Date of Inspection � " � � '�eiephone (952) 2�9-4600 � �'ax(,952)?49-�&6�f� w�wev.ci.o€�ono.ra�n.us _ ___._ ---------._...___._.__—__ � O� O ; O �-`� �- CITY of ORONO �.� ,a ���� _;: � :�. ,��'i►� E� ��,�• G,�ti 1Vtonicipal oefices �'�'��� -��.�.�, Str�eet Address: 9sa-�49—y6o O MaNing Address: ,���" 2750 Kelley ParkwaY P.O. @ox 66 Orono, MN 55356 Cr�rstal �, YN 55323-0066 To Current Owner: Address: 4�''3� S'� �t_ �� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatrnent system at�e above address has been inspected and appeais to fail into the categories checked below. SYSTEM CONFORMII'Y (1-3): � _ - __. .1 "CODE SYSTEM"�An ISTS which meets all the location,design and construction standaras of ihe current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS wkuch does not meet all the location,design and conshudion standards of the curr�t Orono Municipel C.ode but does meex the three foot sepazation requireffient�Lwo�ot requiromeat for systems installed 1996 or effiiier,and owhich is not�7ing or an i�ine�t dueat to public heait3�or safety. �`NON-COMPLIANTSYSTEM'� A���.������a�i�l�Y���p���Y�����y or may not meet all the location,design,or constzucrion stanc�rds of the curr�t Orono Municipal Code and which is failing for any reason;and any ISTS with kss man three fcet of unsa�so�7 or sand between the distn'bution device and the limiting soil characteristics. _ _--— - - — - --- TANK CONI3TTION(5-7): Tanlc inspection indicates: 5 �mpout nat needed at tlris time. �Septic tanks must be pumped out t�is year (city code recommends tanks to be pumped out once every 3 years. Tank was last P�P�. ). Make sure seotic taHks are namoed throne6�anhole and not throu¢h white insnection�ices This allows for the nraaer cleaniaQ. �een water sof�er and iron filter disc6ar�e out of sentic svstem to�rolon¢life ef drainfield Ask numoer to test alarm float to rerifv aiarm is sti11 workiue in vour�ouse. The alarm warns owner that seuta¢e is about to backan into basement 7 Inspect�on nsers miss�ng-tanks could not be inspected. Inspection risers(4"dia.pipe)mast be installed in each tank. If tanks have not been pumped out within the last t�rce years,they should be pumped out now. IELD CONDTITON(8-10): � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,nat critical yet. 10 Drainfield is saturated and visibly discharging untreated ei�luent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENT : �f a�` ��1 U \S r�d� c d�.P►:�- - � r.,,S�-- b C. {' \ac� �Z- � zo�v � � 10 -1 q-o� G1n.°"Df" Date of Inspection Matt Bolterman- Septic System Inspector . Note: In the cveat mat this inspe�ion report is used to satisfy tl►e requirements for a mortgage or other transfer of pmperty,be advised that ffiis nport does not guarantee or oertify that an existing systcm will continue to function ProP�Y> but is merely an opinioa of the adequacy of the system�curr�t conditions�b�sed�We availabk in#'ormation. .�, o,�,. .. .o�,, _ ������� CITY of �RONO ,� � ���.�� ���� .:�;�. �, � ��'���'�i� •y' Municipal Offices �'��;}F���;�;`� �yG ' Street Addross: ' Og Mailln�Address: ESI'j 2150 Kelley Parkway P.O. Box 66 - Orono, MN 55356. Crystai Bay, MN 55323-0066 95a-�49-4600 To Current Owner: Address: 4�3� s�}'� '`1V e N , City Ordinance 199 requires t�hat each existing on-site sewage treatment system in Orono be inspected every two yean. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM"An ISTS which meets all the laadon,design and corutruction standards of the cnrrent Orono Municipal Code. 2 "CONiPLIANT SYSTEM" An iSTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for sysums installed 1996 or earlier,and which is not failing or �-� an immtnent threat W public health or safery. (3 ) "NON-COMPLIAN'T SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may v or may not mcet all the location,design,or conswction standards of t�e current Orono Municipal Code and which is failing for any rcason;and any ISTS with less than three feet of unsaturated soil or sand between the disaibution device and the limiting soil characteristics. TANK CONDITION(5=:7�: � �" Taak inspection indicates: . � . �Pumpout not needed at this time. Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tanlc was last pumped i 0-�0-d Z 1. � Make sure seatic tanks are aumoed through manhole and not throu�h white insnection aioes This allows for the arouer cleaning. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. INFIELD CONDITION �Q : ,� 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. - _ � 10 Drainfield is saturated and visibly dischazging untreated effluent to the s�rface. Contact the City Inspeci`or � immediately.Repairs must be completed within 90 days. � • CO1vUv1G1V1S: IJ�`�:e��l--.l' I(�) )5 l�Cf�— � e; �-•�1,,{^"� ��V Y''�IJJ-�— �\ f /�1�%L(' � �Z-3 i-'1-� t� � -� i � -� v -o� �c� ��Zr-�.,�, Date of Inspection Matt Bolterman- Sepdc System Inspector Note: In the event that this inspection rcport is used to satisfy the requiremrnts for a mortgage or othu transfer of property.be advued that this rsport doa not guacantee or certify that an existing rystem will continue to Cunction properly,but is mqrcly an opinion ofthe adequary of the system unde�cumnt conditiont based on the available infortnation. CITY OF ORONO � O� Municipal Offices O O Post Office eox 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWACiE TREATNIENT r�`,, � INSPECTION REPORT �' G~ � `�k'�sxo�'`' Owner:_�A11 �1�/96N. YVL/q� Address: y23S 5��1 ►ti/�N /�5.���� Permit #�'s: Dates: /'"�� /�7 Contractors: (�l��i� City ordinance nunber 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is�an existing system [ ) new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic�has or [ 7 has not been identified at this time. If the limiting soil characteristic has not been ident" i this classification may be subject to revision.) TANK CONDITION (5-10): � Tank inspection indicates: 5 Punpout not needed at this time. 6 Solids accumulation in tanks irdicates they should be punped out this year to help prevent future problems. 7 Solids accunulation in tanks is at a critical level. tanks should be puiped out as soon as possible. System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been punped out within the last three years, they should be pumped out now. 10 [nspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punpeci out within the last three years, they should be punped out now. DRAINFIELD CONDITION (11-14): ai fi Ld inspection indicates: 11 ainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repeirs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (sloce.setbacks,etc.): W����,�(p�� POTENTIAL FOR SYSTEM FAILURE (decends on soils.water table,etc.): �Ey���� COMMENTS: � ".�� �j c� S-{q r�° ' ' �i S � Date o Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to f�ction properly� but is merely an opim on of the adequacy of the system under current conditions based on the available informat�on. This report must be kept on the pre�nises with the system locetion and punping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner � o� 0 0 ;_�:j��. � ,� CITY of ORONO � �� i; � �E� MunicipalOffices �� � �,��,.�.. �� � '� ',���.4�;;.,,r���'�G Stroet Address: Mailing Addross: 9�tEggOg' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 / � Owner: � a �. �� Address:4235 Sixth Ave. N. Permit #'s:5314 Dates:9/15/78 Contractors:W.D. Wyatt (owner) (This is �]. an existing system [ ] new construction) SYSTEM COMPLIANCE (1-3) : 3 1 Code Svstem: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant Svstem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. � Non-Compliant Svstem: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level � has or [ ] has not been identified at this time. If the eaturated soil level has n t been identified, this clasaification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanka [ ] were or � were not confirmed to be watertight by the licenaed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision.) DRAINFIELD CONDITION (11-14) : 11 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILUR.E: (svstem aqe and condition, soils, etc. ) : medium CONIMENTS: The non-compliant septic system must be repaired by 12/31/2006 or within 90 days of failure (surface diacharge) , whichever comea firat. �-�-9'� � � ,�----- Date of Inspection ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWAGE TREATN�NT � � INSPECTION REPORT ti ���kESH.��'�G Owner: � Address: �oZ��� ��X�d'1 /7✓1�i /V/ Permit #'s: Dates: ��l7t Contractors: �/f/jJJ� !/VL��/^vhB� City ordinance number 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is ,�.an existing system [ ] new construction) YSTEM CONFORMITY 1-3 : "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the Location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating arxi disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or �has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: � Pumpout not needed at this time. S ids accumul t' in tanks indicates they should be out this year to h o i s accumu ation in tan s is ' pe ou as soon as possi e. � 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) �st be installed tn each tank at next punpout. If tanks have not been pumped out within the last three years, they should be punped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate rt�easurement of solids accunulation). If tanks have not been punped out within the last three years, they should be pumped out now. DRAINPIELD CONDITION C11-14): D�field inspection indicates: 1 Drainfie[d is dry, no surfacing evident. Sane evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector imnediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (sloce.setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE Cdepends on soils,water table,etc.): ��>�,�,` ! COMMENTS: ���� Date of nspection ep ic Sys e Inspec or Note: in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opim on of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system locetion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATMENT „� � INSPECTION REPORT ti ��9kESHo��G Owner• GLi//IA� /M�1� Address• T1J�J/1'/L. f��/C. N` . Permit �'s:�3�L�_Dates: 9�7� Contractors:�w�Lic �vi7�owr+e�' City ordinance nunber 700 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �an existing system [ ] new construction) SYSTEM CONFORMITT C1-3): � "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING S1'STEM��-A prohibited system; a system located within a designated 100-year floodplain; any system which mey or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or �7. has not been identified at this time. If the limiting soil characteristic has not been identified, this ciassification may be subject to revision.) TANK CONDITION (5-10): T�c inspection indicates: Cy Punpout not needed at this time. 6 Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. a'f nks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be pu�ed out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia, pipe) must be installed in each tank at next p�npout. If tanks have not been punped out within the last three years, they should be punped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punpecl out within the last three years, they should be Fxmped out now. DRAINFIELD CONDITION (11-14): Dr nfield inspection indicates: Drainfield is dry, no surfacing evident. 2 Sane evidence of surfacing, not critical yet. 13 Drainfietd is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed uithin 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (sloae,setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (deaends on soils,water table.etc.): � COMMENTS: Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opim on of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system locetion and p�mping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore o f Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � � Crystal Bay,MN 55323 473-7357 � �[ ? OWNER ��� � ADDRESS T�`�� S� l�L�, � PERMIT NO.'S. ��7 DATES l���7g CONTRACTORS ���L(O�'�✓� City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat a�d dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is othe►wise creating a public nuisance.Ptease contact the City Ins�ctor to discuss system repair/ replacement proc:edures. If drainfield replacement is necessery,soil testing will usuatly be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: O Inspection pipe is located directly over tank beffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solida aecumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problema. should be pumped out now. ❑ Solids accumulation in tsnks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. ❑ Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surfa�discharge, �Drai�field is saturated and visibl dischar in untreated � Inspection risers missing—tanks could not be inspected, effluent o e su ace_ This condition mav reauire replace- Inspection risers (4"dia.pipe)must be installed in each tank ment or add�*�n.+a *o dc�infiold �^^*Arr th�s Citv InsDector at next pumpout. If tanks have not been pumped out within imme— d'iately.Reoairs must he comoleted within 90 days.� the last three years,they should be pumped out now. ❑ Dreinfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) �Adequate ❑ High water taWe ❑ Low Fair ❑ Lot size ❑ Medium ❑ Poor ❑ Lake,wetland,or stream �High ❑ Inadequate ❑ Drainage System is causing visible surface discharge. COMMENTS: � ��.�� Date of Inspection Septic System Inspector Note: In the event that this i�spection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does�ot guarantee or certify that an existing system will continue to functio�properly,but is merely an opi�ion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Sbore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � . � � 1335 S. Brown Rd. Crystal Bay,MN 55323 473-7357 OWNER / ' ADDRESS ���� SX/f'� f'fl/��� PERMIT NO.'S. �l J DATES J'��7� CONTRACTORS 'rJ City Ordinance No.210 requirea that eech on-site aewage trestment syatem in Orono be inspected on a regular besis.The oniite sewage treetment aystem at the ebove address has baen inspected and appears to fall i�to the category checked below. (This is � an existing synem ❑ new construction) �� Meets w ex�current City stenderds in all respects relating to design,conatruction,and location.Appears to be operating properly. � 2 Does not meet all current City atanderds for new conatruction (1978 Code) but in most respects appears to be designed, loceted, and constructed generolly in accordance with previous codes.System appears to be fu�ctioning properiy;no major upgrading of the system is required at this time. � 3 Does not meet current City standerds in many respects relating to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standerds for design,construction or location,but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creati�g a public nuisance.Please contect the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CON�ITION (m Checked items may require your action) Tank inspection indicetea: ❑ Inspection pipe is located directly over tank beffle.(Does not �Pumpout not needed at this time. give accurate m�urement of solids accumulation.) If tanks ❑ Solida accumulation in tanks indicatea they ahould be pump� have not been pumped out within the last three yea�s,they ed out this year to help prevent future problems, should be pumped out now. O Solicb sccumulation in tanks ia at a critical level. Tanks Drainfield inapection indicates: should be pumped out ea aoon as poseible. �Drainfield is dry,no aurfacing evident. ❑ System is diacharging to aurface. Tanks must be pumped O Some evidence of surfacing,not critical yet. within 48 hours to eliminate surfaoe discharge, � Drainfield i: saturated and visibly discharging untreated O Inspection risera miuing—tanks could not be i�apected, effluent to the surface. This condition may require replace- Inspection rieere (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs mwt be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown, SITE CHARACTERISTICS: �imiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (dePends on soil types,water Future Expansion ❑ Soil table and system condition) �Adequate ❑ High water table �low ❑ Fair ❑ Lot size Medium O Poor ❑ Lake,wetland,or stream ❑ High . ❑ Inadequate ❑ Drainage ❑System is causing visible surface discherge. COMMENTS: 9/7-90 Date of Inspection Se ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report dces�ot guarantee or certify that an existing system will continue to function properly,but is merely an opinion ot the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system locatio�and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Mi�a�zetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER ���lL��fi"/i? �✓}��'Tj ADDRESS � � `�S � � ��L� PERMIT NO.'s. '� -�� y DATES � `�� `� CONTRACTORS �W�G/C City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the ab�ove address has been inspected and appears to fall into the category checked below. (This is I� an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design, construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creati�g a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.l If tanks ---�1 Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems, should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. ----� Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks couid not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipel must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for,System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion _�—� Soil table,and system condition) �--fl Adequate ❑ High water table �—� Low ❑ Fair _�_� Lot size ❑ Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: ���6����r /•5- 11�� e Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requiremen or a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT POST OFFICE BOX 66 1335 S. Brown Rd. � Crystal Bay, MN 55323 • - • • 473-7357 OWNER����I�IArM �• ��1�1T� ADDRESS �a�]J� �1 `�l`T 1-t �1iG /U(��"�"tt PHONE PERMIT NO'S. $3Iy DATES �1'� �' 7$ City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below: � � Meets or exceeds current city standards in all respects relating to design, construction, and location. Appears to be operating properly. ❑ � Does not meet current city standards in some respects relating to design, construction, or location. Appears to be operating properly. ❑ � Does not meet current city standards in many respects relating to design, construction, or location. Appears to be operating adequately. ❑ � Does not meet current city standards of design, construction or location, is being overused, or is failing to properly treat and dispose of the current input and is therefore endangering a water supply, is a source of pollution to surface or groundwaters, is creating a safety hazard,or is otherwise creating a public nuisance. Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re- quired. In al� cases a design and site plan must be submitted for review. Your contractor must obtain a permit before work is started. WORK REQUIRED: � Septic tanks must be pumped within 48 hours. � Drainfield must be repaired or replaced within 90 days. � Inspection riser (4"diam. pipe) must be installed in each tank. � Tank inspection indicates maintenance pumpout is needed as soon as possible. City ordinance reauires that. tanks be pumped out every three years. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑Slope (depends on soil types, water Future Expansion ❑Soil table, and system condition) � Adequate ❑High water table �1ow � Fair ❑Lot size ❑Medium ❑ Poor ❑Lake,wetland,or stream ❑High ❑ Inadequate �Drainage ❑System is causing visible surface discharge. COMMENTS: Si-10�?�.0 BG P::.'1���� "'r" IS li ,/.4�'� C� E;l`���•v' Nr�tT �'.�t"j fs� Date of Inspection S tic System Inspector This report must be kept on the premises with system location and pumping records. WHITE COPY/ Inspector's File GOLD COPY/Homeowner