Loading...
HomeMy WebLinkAboutSeptic Compliance Inspection Form Minnesota Pollution Compliance Inspection Form Control Agency A-7_ Existing Subsurface Sewage Treatment Systems (SSTS) 520 Lafayette Road North St.Paul,MN 55155-4194 Doc Type:Compliance and Enforcement Inspection results based on Minnesota Pollution Control Agency(MPCA) For local tracking purposes: requirements and attached forms—additional local requirements may also apply. Submit completed form to Local Unit of Government(LUG)and system owner within 15 days L System Status System status on date(mm/dd/yyyy): 1/23/2019 ® Compliant— Certificate of Compliance ❑ Noncompliant— Notice of Noncompliance (Valid for 3 years from report date, unless shorter time (See Upgrade Requirements on page 3.) frame outlined in Local Ordinance.) Reason(s)for noncompliance (check all applicable) ❑ Impact on Public Health (Compliance Component#1)—Imminent threat to public health and safety ❑ Other Compliance Conditions(Compliance Component#3)—Imminent threat to public health and safety ❑Tank Integrity(Compliance Component#2)—Failing to protect groundwater ❑ Other Compliance Conditions(Compliance Component#3)—Failing to protect groundwater ❑ Soil Separation (Compliance Component#4)—Failing to protect groundwater ❑ Operating permit/monitoring plan requirements(Compliance Component#5)—Noncompliant Property Information Parcel ID#or Sec/Twp/Range: 1011723320014 Property address: 1270 French Creek Drive Reason for inspection: Property Transfer Property owner: Matt Peterson Owner's phone: 914-406-3545 or Owner's representative: Representative phone: Local regulatory authority: City of Orono Regulatory authority phone: 952-249-4600 Brief system description: Approximately 3-1000 gallon septic tanks,1-1250 gallon lift station and 24X46 feet of chamber bed _ Comments or recommendations: TBM:Top of door threshold. I meet Roger Peitso.The building inspector at the site for soils verifiction. It was the consensus that the periodically saturated soils were located 64 inches below grade. Certification I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. Inspector name: Joseph J Olson Certification number: 1255 Business name: Rusty Olson's Soil& Perc.Testing License number: 810 Inspector signature: _ Phone number: 763-498-8779 Necessary or Locally Required Attachments 0 Soil boring logs ® System/As-built drawing ❑ Forms per local ordinance 0 Other information (list): www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-wwists4-31b • 6141/14 Page 1 of 3 Property address: 1270 French Creek Drive Inspector initials/Date: J.O i 1/24/2019 (mm/ddlyyyy) ...__ 1. Impact on Public Health —Compliance component#1 of 5 Compliance criteria: Verification method(s): System discharges sewage to the ❑Yes ►1 No ® Searched for surface outlet ground surface. ® Searched for seeping in yard/backup in home System discharges sewage to drain ❑Yes ® No ❑ Excessive ponding in soil system/D-boxes tile or surface waters. ❑ Homeowner testimony(See Comments/Explanation) System causes sewage backup into ❑Yes ® No 0"Black soil"above soil dispersal system dwelling or establishment. ❑System requires"emergency"pumping Any"yes"answer above indicates the 0 Performed dye test system is an imminent threat to public ❑ Unable to verify(See Comments/Explanation) health and safety. ❑Other methods not listed (See Comments/Explanation) Comments/Explanation: 2. Tank Integrity—Compliance component#2 of 5 Compliance criteria: Verification method(s): System consists of a seepage pit, 0 Yes ® No 0 Probed tank(s) bottom cesspool, drywell, or leaching pit. ❑ Examined construction records Seepage pits meeting 7080.2550 may be ❑ Examined Tank Integrity Form(Attach) compliant if allowed in local ordinance. ❑Observed liquid level below operating depth Sewage tank(s) leak below their ❑Yes ❑ No designed operating depth. ❑ Examined empty(pumped)tanks(s) If yes,which sewage tank(s)leaks: ❑ Probed outside tank(s)for"black soil" Any "yes"answer above indicates the ❑ Unable to verify(See Comments/Explanation) system is failing to protect groundwater. Other methods not listed (See Comments/Explanation) Comments/Explanation: Elmer J. Peterson Company pumped the tanks 3. Other Compliance Conditions—Compliance component#3 of 5 a. Maintenance hole covers are damaged,cracked,unsecured,or appear to be structurally unsound. ❑Yes* ®No ❑Unknown b. Other issues(electrical hazards,etc.)to immediately and adversely impact public health or safety. ❑Yes* ®No ❑Unknown *System is an imminent threat to public health and safety. Explain: c. System is non-protective of ground water for other conditions as determined by inspector. ❑Yes* ®No *System is failing to protect groundwater. Explain: www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-wwists4-31b • 6/4/14 Page 2 of 3 Property address: 1270 French Creek Drive Inspector initials/Date: J.0 I 1/24/2019 (mm/dd/yyyy) 4. Soil Separation— Compliance component#4 of 5 Date of installation: 5/21/2015 ❑ Unknown Verification method(s): (mm/dd/yyyy) ShoretandNVellhead protection/Food beverage Soil observation does not expire. Previous soil lodging? ®Yes 0 No observations by two independent parties are sufficient, unless site conditions have been altered or local Compliance criteria: requirements differ. For systems built prior to April 1, 1996, and 0 Yes 0 No ® Conducted soil observation(s) (Attach boring logs) not located in Shore/and or Wellhead ❑Two previous verifications(Attach boring logs) Protection Area or not serving a food, beverage or lodging establishment: ❑ Not applicable(Holding tank(s),no drainfield) Drainfield has at least a two-foot vertical ❑ Unable to verify(See Comments/Explanation) separation distance from periodically ❑ Other(See Comments/Explanation) saturated soil or bedrock. Non-performance systems built April 1, ®Yes 0 No Comments/Explanation: 1996, or later or for non-performance systems located in Shoreland or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.* "Experimental", "Other", or "Performance" ❑Yes ❑ No Indicate depths or elevations systems built under pre-2008 Rules; Type IV or V systems built under 2008 Rules(7080. A.. Bottom of distribution media 92.1 2350 or 7080.2400 (Advanced Inspector License required) B. Periodically saturated soil/bedrock 89.1 Drainfield meets the designed vertical C. System separation 3.0 separation distance from periodically saturated soil or bedrock. D. Required compliance separation* l 2.6 Any "no"answer above indicates the system is *May be reduced up to 15 percent if allowed by Local failing to protect groundwater. Ordinance. 5. Operating Permit and Nitrogen BMP*—Compliance component#5 of 5 ❑ Not applicable Is the system operated under an Operating Permit? ❑Yes ❑ No If"yes",A below is required Is the system required to employ a Nitrogen BMP? ❑Yes 0 No If"yes", B below is required BMP=Best Management Practice(s)specified in the system design If the answer to both questions is "no'; this section does not need to be completed. Compliance criteria a. Operating Permit number: Have the Operating Permit requirements been met? ❑Yes ❑ No b. Is the required nitrogen BMP in place and properly functionin•? ❑Yes ❑ No Any "no"answer indicates Noncompliance. Upgrade Requirements(Minn. Stat. §115.55)An imminent threat to public health and safety(ITPHS)must be upgraded,replaced,or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance.If the system is failing to protect ground water, the system must be upgraded, replaced,or its use discontinued within the time required by local ordinance.If an existing system is not failing as defined in law,and has at least two feet of design soil separation, then the system need not be upgraded,repaired,replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas,or those used in connection with food,beverage, and lodging establishments as defined in law. www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 Available in alternative formats wq-wwists4-31b • 6/4/14 Page 3 of 3 Tank Report Date: January 11, 2019 Elmer J. Peterson Co. 5921 Dague Ave. Delano, MN 55328 Phone 763-972-2420 Fax 763-972-7217 MPCA License# 219 Matt Petersen 1270 French Creek Drive Orono, MN 55391 914-406-3545 Baffles: DONOFF Tank Capacity: 3-1000 Gallon Tanks. 1-1250 Gallon Lift Station Per City Records #of Tanks: 4 Type of Tanks: Concrete Gallons Pumped: 3500 Manholes to Grade: YES / NO Comments: On January 11, 2019, Elmer J. Peterson Co. uncovered 2nd manhole (12 inches deep) and pumped septic tanks. Filter in the 3rd tank. No cracks or water leaking in tanks at that time, NOTE: This is only a tank report. This is not a compliance inspection for point of sale nor does it replace a compliance inspection. Property address: 1270 French Creek Drive Inspector initials/Date: 1/11/19 1 1. Impact on Public Health-Compliance component#1 of 5 Compliance criteria: Verification method(s): System discharge sewage to the 0 Yes ❑ No 0 Searched for surface outlet ground surface, 0 Searched for seeping in yard/backup in home System discharge sewage to drain tile 0 Yes El No ❑ Excessive ponding in soil system/D boxes or surface waters. ❑ Homeowner testimony(See Comments/Explanation) ❑ "Black soil"above soil dispersal system System cause sewage backup into 0 Yes ❑ No El System requires"emergency"pumping dwelling or establishment. ❑ Performed dye test Any"yes"answer above indicates the system is El Unable to verify(See Comments/Explanation) an Imminent Threat to Public Health and Safety. ❑ Other methods not listed (See Comments/Explanation) Comments/Explanation: 2. Tank Integrity-Compliance component#2 of 5 Compliance criteria: _-_-� Verification method(s): System consists of a seepage pit, ❑Yes ® No 0 Probed tank(s)bottom cesspool,drywell, or leaching pit. 0 Examined construction records Seepage pits meeting 7080.2550 may be El Examined Tank integrity Form(Attach) compliant if allowed in local ordinance. El Observed liquid level below operating depth Sewage tank(s)leak below their El Yes ® No ® Examined empty(pumped)tanks(s) designed operating depth. If yes,which sewage tank(s) leaks: O Probed outside tank(s)for"black soil" O Unable to verify(See Comments/Explanation) Any"yes"answer above indicates the system is Failing to Protect Groundwater. ❑ Other methods not listed(See Comments/Explanation) Comments/Explanation: On 1/11/19, Elmer J. Peterson Co.pumped septic tanks. 3. Other Compliance Conditions-Compliance component#3 of 5 a. Maintenance hole covers are damaged,cracked,unsecured,or appear to structurally unsound. 0 Yes* ❑No 0 Unknown b. Other issues(electrical hazards,etc.)to immediately and adversely impact public health or safety. ❑Yes* 0 No ❑Unknown *System is an imminent threat to public health and safety Explain: c. System is non-protective of ground water for other conditions as determined by inspector 0 Yes* ❑No *System is failing to protect groundwater Explain: www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • "(TY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-wwists4-31 • 1124/12 Page 2 of 3 Soil Observation Log www.SepticResource.com vers 12.4 Owner Information Property Owner/project: Matt Peterson Date 1/23/2019 Property Address/PID: 1270 French Creek Drive. Soil Survey Information ❑ refer to attached soil survey Parent matl's: ❑Till 0 Outwash ❑ Lacustrine ❑Alluvium ❑ Organic ❑ Bedrock landscape position: ❑ Summit ❑ Shoulder 0 Side slope ❑Toe slope soil survey map units: L4C slope % direction- Linear Soil Log#1 0 Boring ❑ Pit Elevation 94.3 Depth to SHWT 64 Inches Depth(in) Texture fragment% matrix color redox color consistence grade shape 0-10 Fill <35 10-22 Clay Loam <35 I0yr4/3 Firm Moderate Blocky 22-26 Clay Loam <35 10yr4/3 10y4/8 faint Firm Moderate Blocky 26-36 Loamy Sand <35 10yr5/3 Friable Weak Granular 36-64 Med Sand <35 l 0yr5/3 Loose Loose Single grain Comments: . 1270 French Creek Drive. 0 Boring ❑ Pit Elevation Depth to SHWT inches Depth(in) Texture fragment% matrix color redox color consistence grade shape 64-72 Fine sand <35 10yr5/2 10y4/8,1-6/l0y Loose Loose Single grain <35 loose loose single grain friable weak granular blocky 35 -50 firm moderate prismatic platy >50 rigid strong massive <35 loose loose single grain friable weak granular blocky 35 -50 >50 firm moderate prismatic platy rigid strong massive <35 loose loose single grain friable weak granular blocky 35 -50 >50 firm moderate prismatic platy rigid strong massive loose loose <3$ single grain friable weak granular blocky 35 -50 >50 firm moderate prismatic platy rigid strong massive 1270 French Creek Drive. Soil Log#2 0 Boring ❑ Pit Elevation 94.3 Depth to SHWT 64 Inches Depth(in) Texture fragment% matrix color redox color consistence grade shape 0-40 Fill <35 40-50 Sandy Clay Loam <35 10yr4/3 Friable Moderate Blocky 50-60 Sandy Loam <35 10yr513 Friable Moderate Granular 60-64 Med Sand <35 10yr5/3 Loose Loose Single grain 64-72 Fine sand <35 10yr5/2 10y4/8,1-6/l0y Loose Loose Single grain I hereby certifi,this work was completed in accordance with MN 7080 and any local req's. Rusty Olson's Soil & Perc. 810 ..-75"1"esigner Signature Company License# 5C wfSl1k)t 1+": 1278 TRzAck (:ft k '\e — ORo MO A -I) 3t $-t) f14-� u� NO! Ti? SCALE fs 34 ?-3 . C