Loading...
HomeMy WebLinkAboutseptic info � °� 0,;�,,, O ��'�� CITY of ORONO ,� ����°�'� � '�'i� y. �;��1' ,�ti Municipal offices ��9 �;� ��� ¢�G Street Address: Mailing Address: �'EgHO 2750 Kelley Parkway P.O. Boz 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 November 19, 2007 Dear Onsite Septic System Owners: The Orono City Council has adopted new regulations intended to ensure that non- compliant septic systems aze repaired or replaced in a timely manner. As a result of Orono's comprehensive septic system program, many subsurface sewage treatment systems (SSTS)have been deemed to be non-compliant and in need of replacement. In the defined Shoreland Management Areas, owners of non-complaint SSTS have a December 31, 2007 deadline to bring their systems into compliance (December 31,2010 for non-shoreland areas). The Council recognized that many homeowners who were notified of these deadlines, as much as 10-12 years ago, have not taken the necessary steps to upgrade their SSTS. � Under the new ordinance, after the defined deadline date all non-complaint systems must be brought into compliance whenever a building permit is required for any improvements to the home or property. Home maintenance items are exempt, such as painting, furnace or water heater replacement. In addition, formal compliance inspections, in accordance with Minnesota Rules Chapter 7080 will now be required any time a home is sold. These inspections must be performed by a State of Minnesota Licensed Inspector or Designer One. The State of Minnesota has spelled out the criteria for this type of inspection and the required form that must be filled out. The Inspector or Designer One must file a copy of the inspection form with the city within 30 days of the inspection. The SSTS that aze found to be non-complaint must be brought up to code at the time of property transfer. Provisions can be made for transfer during winter conditions. A list of Licensed Inspectors or Designer Ones can be found at the following website, www.uca.state.mn.us/pro�rams/ists/ists xls. Since they are state licensed you may contact anyone/company on the list regardless of county listed. If you have further questions regarding this matter,please feel free to call me at 952-249-4600. Sincerely � ����l�Ci ���� ,��-.✓ Willie Gibbs R.S. . SSTS Manager Telephone(952)249-4600 • Fax(952)249-461b www.ci.orono.mn.us Septic System Upgrade Deadline is Approaching Here's a friendly reminder to all Orono property owners with non-compliant onsite septic systems. Beginning in the mid-1990s the City began to identify those septic systems that made use of trench drainfields, a majority of which do not maintain the minimum required vertical separation above seasonal water tables. Each existing system was subjected to soil borings to determine the seasonal water table depth. When a system was identified as non-compliant,the owner was notified of the need to bring the system into compliance and given several years to complete the upgrade. The deadlines to upgrade were divided into whether or not the property was in the Shoreland District(within 1000' of a lake, or within 300' of a protected tributary stream). Properties in the Shoreland District were given until December 31, 2007 to become compliant. Properties outside the Shoreland area with non-compliant systems were allowed until December 31, 2010 to confoim to the septic code. Don't wait until the last minute! The City is strongly recommending that property owners not wait until the deadline arrives to bring their systems into compliance. The process to upgrade your septic system can be quite lengthy. The first step in the process is to hire a site evaluator& designer to determine what type of system is required and provide the blueprint for the system installation. The property owner must then contract with a septic system installer to have the system constructed. The installation of septic systems is very weather depenclent, especially for niound systems,which can onTy be installed when the ground is relatively dry, i.e. typically June thru September. Contractors' schedules fill up quickly, so it's important to start your planning and design process now to ensure a timely installation. The period of time from deciding to update your septic system to the actual installation can easily exceed three to four months or more. Please contact the Building and Zoning Department at (952-249- 4600) with any questions you may have about bringing your septic system into compliance. For a list of licensed designers and installers you may go to ww�.ci.orono.mn.us, click on City Departments, click on Septic, then click on the link to www.pca.state.mn.us/programs. SEPTIC SYSTEM INVENTORY site Adaress: 3025 Sixth Ave N PID: 2811823320009 Owner Name: Brent A.&Angela McKee Owner Address: 3025 Sixth Ave N Long Lake MN 55356 Building Type: residence Installer: Date of Permit: 12/18/80 Thompson Plbg. System Type: standard trench BRs Designed for: 2 In Musa?: Yes Shoreland?: YES SEPTIC COMPLIANCE INSPECTION Report Date: Compliant Expires: Non-Compliant?: Report in Street File?: SPECIAL NOTES Site Address: 3025 Sixth Ave N 03/16/09 2009 Septic Maintenance Report Letter Sent SEPTIC TANKS Material: precast concrete Capacity: 1000, 1000 Tank Filter: DRAINFIELD Treatment Area: 900 Soil Boring: yes DF Ht above Wt: 0.5 WELL DATA Setbacks-Well-Tanks: 80 Well-DF: 100 Report in File?: Depth: 213 INSPECTION RECORD PUMPOUT RECORD Date Descriation Date Gallons 1 /2/81 replacement installation 04/01/03 2000 8/14/86 no surfacing OS/14/07 1500 6/8/88 no surfacing 9/14/90 no surfacing 8/13/91 no surfacing-pump tanks 10/21/93 no surfacing-pump tanks 4/24/95 no surfacing 7/22/96 no surfacing-pump tanks 10/2/98 non-compliant-repair by 12/31/2005 10/11/99 non-compliant-repair by 12/31/2005 10/09/02 non-compliant,replace by 12/31/2010 10/12/04 Non-complant, replace by 12/31/2007 09/01/06 Non-compliant,replace by 12/31/2007 4/3/2009 1:03:14 PM �C3��" S�x ���. /1.� � � ��I C�d���� � , � � � � : � ; . i� _ � � � � � .� . ; . : _ . . : �, � - � �: � � ` �/ � 1 / . N , ' � ' b I _� �° � ao , a, � ., ,o ; _o''�\ \ � r � �� ; �-_._ . � �1 1 , I000 ��� ' ., � � �� . ' i �� ; 1000 G4L `� � � � •` . ;1 � i Y�_ � � ♦ \ D.Sox ' � . i � � � I _ � I 1 � � � i , , � I 900•s� i I �c'a��n ��c Lc� � I ( � 3o2.s �+� Ave � I I I, 1-2-8( i • i i . � ra ''"� -.... .�;, ; . ,� .� � � �� /,f,,o �.,,\,'11 !�� � i�� CITY of OliOloTO ��. ,� �� , �,: ;�: , ' "� �, Municipal Offices ,, "� ' ti � `, Street Address: Mailing Address: �9 ' `r p4�'G 2750 Kelley Parkway P.O. Box 66 k'ES?�I .--.__ - Orono, MN 55356 Crystai Bay, MN 55323�0066 To: The Current Owner of Address 3G � � S %�'"�� City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Ident' d as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31,2007 � December 31, 2014 Other Septic Tank(s) Pump out Needed Yes �No The City recommends the septic tank(s) and/or lift tanlc be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on � - � -�� . The tank(s) should be cleaned through the manhole and not tlu•ough the inspection pipes, this allows for proper cleaning. r Comments: �c.,t"�� � �T� � ��� � � � � w � � �-aC Inspe � °° � Date of Inspection 'lle6ep�aone (9�2)2�9-�d600 � �'ax (9�?j 2�9-��5�� www.ci.o�ono.nn.us � _ __ _ � � . O <., O ��:��� ciT�o� oRo�vo � � ����� __ . �„ ' ` ��'• Municipal Offices ' '�r� r� �����K� G�' o 0 ��:,;�� .�� 1�',�, Street Address: �i Sa-a►4 q-y b Mailiog A�ross: ,�p'�" 2150 Kelley Parkway P.O. Baa 56 Orono, MN 55356 G�stal 13ay, �I+I 55323-0066 . /�- , To Current Owner: Address: 3�'� s'�` '�"L , N- City Ordinance�99 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. The on-site sewage treatment system at the above address has been inspected and appeais to fall into the categories chec:ked below. SYSTEM CONFORMTTY (1-3): � . ___ --- _ . _ _ . 1 "CUDE�SYSTEM"An 1ST5 which meets all the location,design and construction standards of the came�t Orono Municip�t Code. 2 "COMPLIANT SYSTEM" An LSTS which does not meet all We location,design and constiucri�standards of the curreut Orono Municipal Code but doe.s moet the Wree foot sep�ation requuement�trvo Soot iequir�t f�systems installed 1996 or earlier,and � wlrich is nar�iling or�immine�t tlueat to public health or safexy. (3 ) "NON-CO1vIPLiAN'I'SYSTEM" A plohibitoa LSTs;�ISTs tocatea w;min a aesignacoa loo-year fiooa plain,any rsTs wbich may `/ �may not meet sll the location,design,or construdion stan�rds of�e ciureflt Orono Municipal Code and wluch is failing for any reason;ffid any IST'S wiW less fhan thtee feex of unsaUuated soil�sand b�vvcen the distnbution dcvice and the limiting soil charactetistics. TANK CONDITTON f5-?): � Tank inspection indicates: 5 Pompout not nceded at this time. �Septic tanks must be pumpad out dris year (city code recommends#anks to be pumped out once every 3 years. Tank was last P�P�. �-���� 1. Make sure seatic tseks sne��ned throeeh manhok and aet�roa¢h wribe iosaectioa nices. Tkis allows for the nrooer eleanies Keea water soffaer aad iron 61ter disc�arge oat of sentic svstem to nroloa¢lih ef drainfield. Ask aumner to test a�arm#loat to verifv alar�is still werki�m vour hoase. The alarm wares ow�er ffiat�uta�e�about to backsa iHto besee�nt 7 Inspection rise.rs missing-tanks could not be inspected. Inspedi�ris�s(4"dia.pipe)must be installed in each tank. If tanks have not bee�►pumped out within die last t�uee years,they should be pumped out now. DRAINFIELD CONDTTION 8-10 : � ' 8 �ainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. i0 Drainfield is sabu�ated and visibly discharging�u►treated e$luent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. co�rrT : pc�,,.�t�� :5 ro� c v�.p�.�..�- - � ���r be. c�4��c.L� b-� �i.-��- Z:a�o ., \v �t=o� G`�� �.�-�, Date of Inspection Matt Bolteaman- Septic System Inspactor Note: In the eveu d�t this iospa�ion report is used to satisfy We requirements for a mortgage or othcr transfa of propaiy,be advised that this report dces not guarantae or attify Wai an existin8 system w71 contin�to fimction ProPaIY, but is m�rely an opinion of the ad�quacy of ti�e system under curnnt conditions besed on the ava�'lable�#'orma�ion. Y f � O� �t •�q� O . ��``��� . CI�I�"'of ORONO ' °�`'���? `�¢► 1�,�� �''�. ti ., �; .� ��p�i}.j-'^���� G'ti Munic4pal onces • l �•:r,�;�;,�. �i ' Street Address: �K�g 2150 Kelie Paricwa Mailin�Addreu: y y P.O. Box 66 Orono, MN 55356 . � Crystal Bay, MN 55323•0066 � 95d-�yq=y600 To Current Owner: Address: 3 oas s;�i, f��c� _�l/, Ciry Ordinance 199 requires that each existin�on-site sewage treatment system in Orono be inspected every two yean. The on-site sewaae treatment system at the above address haz been inspected and appears to fall into the eategories checked below. SYSTEM CONFORMITY (1-31: ,� 1 "CODE SYSTEM"An ISTS which meets sIl the location,design and construction standards of the enrrent Orono Municipal Code. 2 "CO�LIANT SYSTEM" An iSTS which does not meet all the location,daign and eonstruction sundards of the eurtent Orono Municipal Code but does meet the three foot separation nquirement or two foot rcquirement for rystems irutalled 1996 or tariier.and which is not failir.;or 3O ='an tmminent threat to pablic health or safery. "NON-CObiPLIANT SYSTEhi" A prohibited ISTS;an ISTS locaud within a daignated 100-year flood plain,any IS?S which may or may not meet all the locatian.design,or eonswcdon standards of tju current Ocono Municipal Code and whIeh is fa�'ling for any teason;and any ISTS with less than three feet of unsaturated soil or sand between the distribndon device and the limiting soil eharacteristics, TANK CONDITION(�-:7�: 5 Y �� T inspection indicates: � . . ��Pumpout not needed at this time. � 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 yeazs. Tank was last pumped_ ), � �Iake sure seotic tanks are oumoed throuoh manhole and not throu,gh white inspection pines This allo�►s for the proper cleaning. 7 Ins�ection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. RAINFIELD CONDITION -IQ : � 8 Drainfield is dry,no surfacing evident. _- Some evidance of surfacing,not critical yet. ; ��� � 10 Drainfield is saeurated and visibly discharging unG�eated eE�luent to the surface. Contact the Ciry Inspector immediately.Repain must be completed within 90 days. Co��NTs: DSG:tS.�\� �s r�dc,- cv�.��;�.�} QnJ fi.�S�- �z� <�p�cce� � y \�-��-LO�v _ I 0 -�1—��- �2� Date of Inspecdon hiatt Bolterman- Septic System Inspector Note:in tlse event thst this inspection report is used to satisfy the rcquirements for a moctgage or other transfer o[properry.be advised that this reFoR does not gu�n��- orcertiPy thst an existing system will eontinae to function properly.but is merely an apinion afthe adequary of the system under eurrent condidoru based on the avulabie infortnstion. , � CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWA(�E TREATMENT v�,',� ��, INSPECTION REPORT G �9kESH�4`'� Owner:_�1�✓1 f �clr�e. Addres s: 30 2 J� S%X�"/� /�-t/t+'�/�� ��c3b'(s 1 Permit �'s: 233 Dates: ��"/�—� Contractors: �l�L�'�1d�d)') l���l �-, City ordinance n�ni�er 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular besis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �J an existing system [ ] new construction) SYSTEM CONFORMITY C1-3): � 1 ��CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limitin� soil characteristic J� has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi�ie8; this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids eccumulation in tanks indicates they should be puriped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. tanks should be punped out as soon as possible. System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface discharye. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe> must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). If tanks have not been punped out within the last three years, they should be p�rnped out now. ORAINFIELO CONO1T10N (11-14): ' t -;-F— D �eld inspection indicetes: Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not criticel yet. 13 Dreinfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING S1TE fACTORS Cslope,setbacks.etc.): ��.�n,.f�,y(��L POTENTIAL FOR SYSTEM FAILURE (deaends on soils.water table.etc.): ��/�V� COMMENTS: S � /� t ` � (,'�C�C, �{ /r �f- S ' ►nc ` l eas ! 2- Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opin�on of the adequacy of the system under current conditions based on the available informat�on. This report must be kept on the prerises with the system locstion and punping records. WHITE COPY/Ins�ctors File YELLOW COPY/Homeowner ,,��°� ,'o 0 CITY of ORONO .��,, '�' �y �� ', lS� Municipal Offices � . l .. r t���i1A �/� �� � 1 �,a ,� Street Address: Mailing Address: \lt'�g0'�' 2750 Kelley Parkway PA. Box 66 Orona, MN 55356 Crystal Bay, MN 55323-0066 Owner: �rei')� '"� L' �C� Address: 3025 3ixth Ave. N. Permit #'s: 6233 Dates: 12/18/BO Contractors: Thompson Plbg. (This is (x] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) :�� 1 Code System: Meets r exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. � Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [X] or is not [ ] identified under this septic system. If the ' saturated soil level is not id�ntified, this classification is subject to revision.) TANK CONDITION (5-9) : 9� 5 Pumpout not neede at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [� or are not [ ] water tight or the condition is [ ] unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) D�tP,INFIELD CONDITION (11-14) : � 11 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0.5 feet and the system is non-compliant. Repair or replacement of the septic system is required by 12/31/2005. v' �L� ' � J � � � Date of Inspection Sep System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 - - ,_,: . � O�\\� O O ��. � CITY o� ORONO �. , ,���r�, � �� v��`�, ��� `�� '��fi �.���� �l� �� Municipal Offices '�' ��' '`�.:, ``r�,;:� G / .� .�/ Street Address: Mailing Address: `q$'EgKOg/ 2750 Kelley Parkway P.O. Box 66 =_-_= Orono, MN 55356 Crystal Bay, MN 55323-0066 , � � �J Owner: ,( ��� �" � ��f^- � - Address:3025 Sixth Ave. N. Permit #'s:6233 Dates:l2/18/80 Contractors:Thompson Plbg. (This is (X] an existing system [ ] new construction) / 4 YSTEM COMPLIANCE 1-3 : 1 � 1 Code Svstem: Meets or exceeds current City standards in all respects relating to -- design, construction, and location. Appears to be operating properly. 2 Compliant Svstem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant Svstem: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level � has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision. ) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been � pumped out within three years, they should be pumped out and risers installed now. ,�9)" Inspection pipe is located over tank baffle-can not measure solids accumulation. If V tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or [ ] were not confirmed to be watertight by the licensed pumping contractor. If the a ks were not confirmed to be watertight, this classification is subject to revision. ) D INFIELD CONDITION 11-14 : 11 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system aqe and condition, soils, etc. ) : low COMMENTS: . �d`�D��_�C 3 e��----- !r'.�iLI Date of Inspection Sep ic System nspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 . . �°� CITY OF ORONO O O Municipal Offices Post Offite Box 66 Crystal eay, MN 55323-0066 � � ON—SITE SEWAQ�E TREA'1'I�NT INSPECTION REPORT ti ti ��9k o��G ESII Owner: Address: .\C,oCJ J/X� �1/�is /Vi Permit �'s: Dates: ����C_Q( 7 Contractors: �C�L7� �LYI�. City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a reg�lar besis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system [ ] new construction) STEM CONFORMITY 1-3 : 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM'�-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any poltutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodptain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limitin� soil characteristic„� has or [ ] has not been identified at this time. If the limiting soil characterist�c has not been ident�fied, this classification may be subject to revision.) TANK CONDITION (5-10): � T,en1c inspection indicates: ��1 Punpout not needed at this time. 6 Solids accunulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. 'fanks should be punped out as soon as possible. 8 System is discharging to the surface. Tanks must be Fxmped out within 48 hours to eliminate surface dischar$e. 9 lnspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. lf tanks have not been pu�ped out within the last three years, they should be puqxd out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). If tanks have not been p�mped out within the last three yeers, they should be Fxnped out now. DRA[NFIELD CONDITION C11-14): Dr i field inspection indicates: t Drainfield is dry, no surfacing evident. Sane evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (sloae,setbecks,etc.): POTENTIAL FOR SYSTEM FAILURE (decends on soils.uater table.etc.): COMMENTS: Date of nspection e ic System nspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to f�mcti� properly� but is merely an opinion of the adequacy of the system under current conditions besed on the available informat�on. This report must be kept on the premises with the system locetion and pumping records. WHITE COPYllnspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(�E TREATMENT r�`,� � INSPECTION REPORT ti ��9kESH.��'�G Owner• +.J� �/ Address• �� .S17(� �/j0 /(l1 d Permit �'s: ��.� Dates: ����� Contractors: //�v�,�,or�►-�, 1'7I�, City ordinance number 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is P7•.an existing system [ ] neW construction) SYSTEM CONFORMITY (1-3): 1Q "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system Which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface uaters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic p�]..has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identifiied, this classification may be subject to revision.> TANK CONDITION C5-10): � Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. 'fanks should be pumped out as soon as possible. 8 System is discharging to the surface. tanks must be pumped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed tn each tank at next purtipout. If tanks have not been punped out Within the last three years, they should be pumped out now. lnspection pipe is located direc�� over tank baffle (does not give accurate measurement of solids accumulation). If tanks haua_nnr Iwen n n�i uithin the Last three vearc_ YhPv shnulrl hP rvmnari nur nnu r r DRAINFIELD CONDITION (11-14): D field inspection indicates: 71 Drainfie[d is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �� COMMENTS: � " _ � Date of Inspection ptic yste nspector Note: In the event that this inspection report is used to satisfy the requirements for a �rtgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properlyi but is merely an opinion of the adequacy of the system under current conditions based on the available �nformatton. This report must be kept on the premises with the system location and pianping records. WHITE COPY/Inspectors Ffle YELLOW COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay, MN 55323 473-7357 OWNER ADDRESS ��d`� ��� ��� /�"� PERMITNO.'S. DATES ���b� CONTRACTORS � City Ordinance No.210 requires that each on-site sewa�treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has bee�inapected and appears to fall into tne category checked below. IThis is � an existing system ❑ new construction) �� Meets or exceeda current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and co�structed generally in accorda�ce with previous codes.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Dces not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time,but has a relatively high potential for future problems. No majo►upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location,but is fai�ing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is ne�ssary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION (m Checked items may require your action) Tank inspection indicates: �Inspection pipe is located directly over tank beffle.(Dces not ❑ Pumpout not needed at this time. grve accura e mea:uremen o so i s accumu a�o . ❑ Solids accumulation in tenks indicates they should be pump- have not n um ou w��� e as t ree years,they ed out this year to help prevent future problems. ould be pumped out now. ❑ Solida accumulation in tanks is at a critical level. Tanks Drainfield inspect�on in icetes: should be pumped out as soon as possible. $�Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge, ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risera miasing—tanks could not be inapected. effluent to the surface. This condition may require replace- Inspection risers (4"dia. pipe)must be instslled in each ta�k ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system co�ditio�) O Adequate ❑ High water table ❑ Low �.Fair ❑ Lot size �-Medium ❑Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑System is causing visible ^ surface discharge. � - ✓ COMMENTS: n � dJ.�, lGI � t ��H Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requireme�ts for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available info�matio�. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner