Loading...
HomeMy WebLinkAboutseptic info ` i SEPTIC SYSTEM INVENTOR Y Address: 2060 Sixth Ave. N. PID: 27-118-23 31 0002 Building Type church BRs Install'd for: 575 In Musa: Yes Permit#: 1409 Date of Permit: 11/7/88 Installer: Jerry Johnson System Type: mound Experimental: no Tank Filter: SYSTEM CONDITION Conformity: 1 Tank Condition: 5 DF condition: 11 Failure Pot: low SEPTIC TANKS Material: precast concrete Capacity: 1000, 1000, 1000 Setback to Bldg: 20 Cesspool: no DRAINFIELD Length of Lines: 150 # Lines: 3 Trench Width: 10 Treatment Area: 80*30 Type of Filter: rock,clean sand Soil Boring: yes Tile Size: 1.5 Under Tile: 9 Perc Rate: 15 Setback DF-Bldg: 75 DF Ht above Wt: 3 Soil Type: clay loam Limitations: water table WELL DATA Setbacks - Well-Tanks: 90 Well-DF: 75 Report in File yes Pump Type: subm. Depth: 179 Diameter: 4 Method: drilled INSPECTION RECORD PUMPOUT RECORD DA TE DESCRIPTION COMPLIANCE DA TE GALL ONS 11/18/88 replacement installation 1 9/25/00 2600 9/13/90 no surfacing 1 3/11/02 2800 5/16/95 no surfacing-pump tanks 1 9/23/98 compliant 1 9/5/00 no surfacing, pump tanks 1 10/08/02 no surfacing code system f�_ i 2.o�l Q IG N��j K� �1 5 U � �/ o G ��"'#'�'' � �A''TG Q�o L�� � `� d 7 � �` _ � �, , , i _ I � � � i ��C� �JX-�-� /-�✓�k /l�� --_---_, ; �� , �� � ---- , � . ---______ __ --_- -- -- - - -�-_--- , ; , , - , � , , � ` � - - - � � � � ��s't' I� � ' ; � � — �. _ _ _ , � � � i �\� � I I � C� i � � �� � � , � ( � - � � I � N � F.e� � � � � $i P °�' o o ° � 7", � Tz ��' 2�'a ` � " � T3 8'� �lo'(� 7' ��' O : O ����- CITY of ORONO �, '��'� �.. ti M�«� ort� �t—� , G~ Street Addreas: �ISa-�49-�'160 o M�ilia�Addross: "��k •i�` � '�$'�p�" 2750 Kelley Pa�kway P.O. Bar 56 Ororw, MN 55356 Crystal B�s�yy, MN 55323-�66 To Current Owner: . Address: o�C�60 S;X�'1� {�d t, I v� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. _. _ _ _ TEM CONFORMITY 1-3 : � T "CODE SYSTEM"An�ISTS which meets all the location,design and construction standards of the cutrent Orono Municipal Code. 2 "COMPLIANI'SYSTEM" An LSTS which does not meet all�e location,design and conshvdi�standards of the�t Orono Iviunicipal Code bui does me�t!�Wree foot separation requir�ent or two foot requir��t for systems iastalled 1996 or eaiiia,and wluch is not failing or mm ro�mineat Wreat w public health�safety 3 `2iON�0IVIPLIAN7'SYSTEM" A prolubitea IS1s;an ISTs located wid�in a aesignatea loo-year aooa plain,any ISZs whic�may or may not me�all the location,design,or canstruc�ion standards of the cutre�t Urono Municipal Code and wl�ich is failing fior any reason;and�y ISTS wiW less than t�uee fcet of unsaUuated soil or sand betwe�t�e dish�'bution device�d the limiting soil charact�ris6cs. TANK CONDITION(5-�: Tank inspection indicates: �\��umpout not needed at this time. 6 Septic tanks mast be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped �-1\—�L ). Make sure seatic�taaks are aue�ued t�reu�h�aehole and aot t�rou¢h w�ite iasnection niaes. T�is allows for ffie oroaer cle�nins. Kcea water soi�wer and iron�ilter discLar�e oet of seatic svsbem M urolong life of dr�iafield. Ask oa�cer to test alarm 8oat te verifv alara�is stiil w�ua ia vour�ouse. T�e alarm waras evrner tbat seot�e is abont to backna into basement 7 inspection risers missing-tanks could not be inspected. �nspection risers{4"dia.pipe)must be installed in each tank. If tarilcs have not baen pumpad out within the last three years,dzey should be pumped out now. D IELD CONDITION 8-10 : � � 8 rainfield is dry,no surfacing eviden� 9 Some evidence of surfacing,not critical yet. 10 Ihsinfield is saturated and visibly discharging untreated e$luent to the surface. Contact the Gity Inspector immadiately.Repairs must be completed within 90 days. CO��IlvIENTS: /``�u^J � St�1-.'Z_. ��5 t bo� b�� . \o-IL-v� �� � Date of Inspecrion Matt Bolterman- Septic System Inspactor Note: In the tve�t th�t fhis in�a�report is used to satisfy the require�ents for a mortgage or otha tiansfer of�xoperty,be advised that thic report�es not guarantoe oi catify that an existing system wll continue w fiwchon properly, but is meaely an opinion of the adequacy of the syst�aadea cuaent conditions based on the available�matiion. o �� � � .i .��, . o . -��=j��? � CI�`Yof ORONO � .a �1 '��,l'�<=�. ti `�',� •�f4i�j,i+�� G'ti btunlcipal offices .. '`' } .;. 'Z '•�.}}��Og'�Y ' Street Address: Malltng Addrasss �K . 2750 Keliey ParScway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•006b � 9sa•�4q-y600 � To Current Owner: Address: a�6O S�k-f� �V.� �/ . Ciry Ordinance 199 requires that each existin�on-site sewage treatment system in Orono be inspected every two years. The on-site sewa�e treatrnent system at the above address has 6een inspected and appeazs to fall into the categories checked below. SYSTEM CONFORMITY (1-31: � 1�"CODE SYSTEM"An ISTS which mcets ali the location,design and construcdon standards of the current Orono hiunicipal Code. 2 "CO�LIANT SYSTEM" An ISTS which doa not meet all the location,design and construction standards of the current Orono hiunicipa! Code but dou mect the three foot separation requirement or two foot requirement for systems uutalled 1996 or eazlier,and which is not failing or 'an icnmiaent tlueat to publie health or safery. 3 "NON-COyiPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a duignated 100-yeu flood plain,any ISTS which may or may not meet all the lecatioa,design,or eonstrucdon standards of the current Orono Municipal Code and which is failing[or any rcason;and any ISTS with less than three feet of unsaturated soil or sand between the distribudon device and the limidng soi]eharacteristia. TANK CONDITION(5.?l: s . Tank inspection indicates: � . . 5 Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requues tanks to be pumped out once every 3 years. Tank was last pumpzd 3-��-o� ), � l�iake sure sentic tanl:s are aumned throuah manhole and not through�vhite insnection nipes This allo�ti•s for the orooer cleaning. 7 Inspection risers missin�tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. DRAINFIELD CO�IDITION!S-tQ): � �8 Dninfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. , � 10 Drainfield is saturated and visibly dischargin�untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be eompleted within 90 days. CO1�11�i iENTS: M��^� n^� SeP+� � �-ank5 Ico� d� - 1� - �'-Oa �a�C Date of Inspection Matt Belterman— Septie System Inspector Note: In the event that this inspection rcport is vsed W satisfy th�rcquiremencs fa�a mortga;e or other transfer of properry.be advised that this rcpoR doa not gu��.'���� or certify that an eristing rystem wili continue W function properIy.but is meceiy an opinion ofthe adequary of the system under eurrent eonditions based on the avsilabie information. �o� ;,,�o 0 �,', :, .t�, .�, ,� CITY of ORONO ' � l5� � Municipal Off3ces �� �� ��;_ �� r �j� ti � ,t .:°::�:_,'�'>,`-;�G Street Addross: Mailina Addross: ''�'Egg04' 2750 Kelley Pa�kway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 September 6, 2000 Trinity Lutheran Church 2060 Sixth Avenue North Long Lake, NIN 55356 To Whom It May Concem: An inspection of your septic system was conducted on September 5, 2000. A summary of the inspection is below. Septic Tank Condition 1. Pumpout needed within one year. (last pumpout date unknown) The septic system is a compliant system, meaning it meets all or most current City and State Standards. Enclosed is a list of licensed contractors who work in Orono on a regular basis. This list is enclosed simply for your reference in case your septic system needs maintenance in the future. Also enclosed is a fact sheet explaining your septic system and how it functions. Finally, an as-built dra�ving is enclosed showing the approximate location of the septic system. If you have any questions regardin�this report, please contact me at the City Offices at 249-4600. R pect lly, s ) ,�tit,c� Chris Pence On-Site Systems Mana�er Enclosures In the e�ent this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be ad�•ised that this report does no guarantee or certify the eusting sv stem«�ill continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the sy stem location and pumping records. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us /� �� ,; o o , ;�, � ,i ��f�L ��, ,� I CITY of ORONO ``��'�'+� � ,'�- '�� �� ,�l5r Municipal OfSces \\��9 �`;�I �'�g.�G Street Address: Mailin�Address: �EgHO 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 � Owner: � t(�'/r 1^'., � ' f.� , Address: 2060 Sixth Ave. N. Permit #'s: 1409 Dates: 11/7/88 Contractors: Jerry Johnson (This is [x] an existing system [ ] new construction) . YSTEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [�( ] or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) TANK CONDITION (5-9) : 6 �{ Pumpout not needed at this time. ( 6J Solids accumulation in tanks indicates they should be pumped out this year. � System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [�] or are not [ ] water tight or the condition is [ ] unknovm. If the tanks are not confirmed to be watertight, this classification is subject to revision.) RAINFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low CONIl�IENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 3 feet and the system is compliant. ����1'�� ' � --�ate of 2nspection ep i System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO �O� Municipal Offices O O Post Office eox 66 Crystal Bay, MN 55323-0066 a � ON—SITI� SEWA(;L TREATl�NT v�;, �, IN3PECTION REPORT � G� �9kESH.Og'� C�u� ^ Owner• Address• ��(y S) � � I . Permit #�'s: 0 Dates: �/��� Contractors: City ordinance number 100 requires that each on-site sewage treatment system in Orono inspected on a regutar besis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked betow. (7his is �, an existing system [ ] neW construction) SYSTEM CONFORMITY 1-3 : "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the lxation, design, and coqstruction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating setisfacto�ily by treating and disposing of the entire current sewage input without discharging any po llutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM��-A prohibited system; a system located within a designated 100-year floodplain; any system which mey or mey not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limitin� soil characteristic '�D'�]�has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: Pumpout not needed at this time. 6 Solids eccunulation in tanks indicates they should be punped out this year to help prevent future problems. Solids accunulation in tanks is at a critical level. Yanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in eech tank at next punpout. If tanks have not been pumped out within the last three years, they should be pun�ed OUL 110M. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out within the last three years, they should be puiped out now. DRAINFIELO CONDITION (11-14): D�nfield inspection indicates: 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City lnspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition �known. LIMITING S1TE FACTORS (sloce.setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (decends on soils,water table.etc.): COMMENTS: Date of Inspection ep c Syatem Inspector Note: !n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an op�m on of the adequacy of the system under current conditions based on the available informati�. This report must be kept on the premises with the system lxstion and punping records. WHITE COPYllnspectors File YELLOW COPY/Homeowner