Loading...
HomeMy WebLinkAboutseptic info . � SEPTIC SYSTEM INVENTORY Site Address: 1305 Sixth Ave N PID: 2611823340004 Owner Name: Mary H. Dayton Owner Address: 1305 Sixth Ave N Long Lake MN 55356 Building Type: residence Installer: Date of Permit: unknown System Type: standard trench BRs Designed for: 4 In Musa?: Yes Shoreland?: YES SEPTIC COMPLIANCE INSPECTION Report Date: Compliant Expires: Non-Compliant?: Report in Street File?: SPECIAL NOTES Site Address: 1305 Sixth Ave N 03/16/09 2009 Septic Maintenance Report Letter Sent SEPTIC TANKS Material: concrete Capacity: Tank Filter: DRAINFIELD Treatment Area: 300 Soil Boring: yes DF Ht above Wt: WELL DATA Setbacks-Well-Tanks: 100 Well-DF: 120 Report in File?: Depth: INSPECTION RECORD PUMPOUT RECORD Date Description Date Gallons 7/14/80 no surfacing-drain tile exits on hillside 07/22/80 1200 8/12/86 no surfacing 08/09/88 1000 7/13/88 no surfacing-tanks buried 10/18/04 2000 9!12/90 no surfacing-need 1st tank risers 10/12/07 2000 5/15/95 non-conforming-repair by 12/31/97 9/16/98 non-compliant-repair by 12/31/2002 8/23/99 no surfacing-repair by 12/31/2002 10/07/02 non-compliant,replace by 12/31/2010 sewer available �/�� � 10/08/04 Non-compliant, replace by 12/31/2007 U v � �� 09/01/O6 Non-compliant, replace by 12/31/2007 �i� �! /'� ` � l./ O � ,\ � � � � � 4/3/2009 1:03:13 PM iI . � I ���� ��X�"� �. � � i � � � � i � � � � � � I )� � � l � ` _ � � � � � '. , , ^ _ _, - �_ _ _ _ . - � � r� � ��E�-L i ' � I � � --�_ /S $� 38� \� s,9� i ���K � - � - - ; - - - - -� �. � - - - - - - � i � L� � �'�� ; p�TF � � i , , � I i i �----� � — � ' L oti�� !� K E � �'' i , � � --- -- ; , .� _._._.� _ _.��?` . � - s �`%'/,� � `,'', �� CITY of UIi4N0 �� i'� �, ,� �:. ; ' �,;��' Municipal Offices `,.'�'� �!' ' . G"�' � ' Street Address: Mailing Add�ess: �'4,kEsxp4��, 2750 Kelley Parkway P.O. Box 66 ,�, _,--:. -- Orono, MN 55356 Crystal Bay, MN 55323•0066 To: The Current Owner of Address � �S� .� � '� ��'� City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public alth Threat Yes No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of rec�ipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Ident' d as Non-Compliant Yes No If yes, system must be brought into c mpliance by: � \ December 31, 2007 �1� December 31,2010 � � Other �, � Septic Tank(s) Pump out Needed � Yes � ��', No The City recommends the septic tank(s) and/or lift tanl:be serviced and pumped out every three ears. City records indicate the tank(s) were last pumped out on � � �- �$-�`� . The tank(s) should be cleaned through the manhole and not throu�h the inspection pipes, this allows for proper cleaning. � Comments: � � y w p �11 Inspect��� � �� ,. '�' � Date of Inspection ( -� �' , � �� � � '�elephone (95?)2�9-4600 � Fa�(��3) 249-a6Il�, ac�w�w.ci.ot'ono.mn.us o ._ . � � o_:,:.,. o . ��:�� CITY of ORONO �, ���,'' �;;- �, M��o� � '� �.� . �~ sa� �aa�:� qsa-�►4q-y6o o reitiqB Addrsss: � ���`�p�'� 2750 Kelley Parkway P.a. �ar b6 Orono, MN 55356 Cr�►stsl �, MN 55323-0066 To Current Owner: Address: �3 a 5 S'�(�,L �J� M� City Ordinance 199 requires that each existing on-site sewage treat�nent system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. ' ' , SYSTEM CONFORMITY fl-3): � 1 "CODE SYSTEM"An ISTS which meets sll the locgkion,design�and conshuction atandards of the cu�f Orono Municipal Code. 2 "COMPLIANT SYSTEM" An LSTS wtuch dces not mec�all the locstion,design and construdion standards of the qureat Orono Municipal Code but doe.s me�tl�throe foot separatio�n requir�ent�two�oot requirem�t for systems instelled 1996 or esrlier,�d which is not failing or an i�ina►t threat to public health or safcty. 3O"NON-COIVIPLIANT SYSTEM" A prc�lubitea ISTs;an LSTs locsted within a aesi�loo-year 800a plain,�y ISTs which may or may not meet all t1�e location,desi�,or cons�udion stan�rds of the current Urono Municipel Code and which is fa�7ing for any reason;�d any ISTS with less ii�an three feex of unsst�uatod soil or sand betwe�die distnbution device�d tl�limiting soil c�aracttais6cs. TANK CONDTTION(5-71: �f T inspection indica#es: 5 Pumpout not needed at this time. 6 Septic tanks must be ed out tlus year (city code recommends tanks to be pumped out once every 3 years. T�W�i�c���D —ik-��{ �. Make sure seatic tanks are numaed f�'a�6�aeLole aad aot ti�roa¢h wLite i�scection uices. This allows for ffie aroner cleani�s. Keea w'�er softaer aed iroe fitber dischar¢e out of seatic svstem to prolong iife ef draiefield. Ask nomaer to test alarm float to verifv aiarn is�ill worki�ie vour�onse. The alar��var�s owaer t�at seata¢e is aboat to backuu into basement 7 Inspection risers missing-tanks could not be inspected. Inspaction riseis(4"dia pipe)must be installed in each tank. If tanks have not been pumped out within�e last�years,they should be pumped out now. LD CONDTITON(8-10): � -' 8 Drainfield is dry,no surfacing eviden� Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector unmediately.Repaus must be completed within 9U days. co s: �Jc�.:�.-��� �S �� co�p�.�.d- �. - c...�� bc. �c�01�u � �-L-3�-z.o t v 10 �-a� � Date of Inspaction Matt Boltern�an- Septic System Inspector Note: In the evmt that Wis iospection report is usod w satisfy the requv�ents for a mortgage or othc transfa of property,be advised that this report does aot guarantee �cxatify thffi�existing system wll o�tinuc to fundion properly, but is meaely an opinion of the adaluacy of tl�sysb�under c�urmt condidons based ort the availabk�otmstion. o � � � .� .:, o . -�"��� CITY of OR4N0 � ��. �� �a ..�;_;: s,► �1 ` � ,,� s, �-; �;.. �" � biunlcipal offces ' � � �• .i� `�4 � . l ��'',�#�.��►�,G - �•.,.;:►,Og Street Address: INatling Address: H 2150 Keiley Parkway P.O. Box 66 Orono. MN 55356� Crystal Bay. MN 55323-0066 � 95d-�49-4600 To Current Owner: Address: �3�S S '�� ��C N , City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewa�e treatment system at the above address has been inspected and appeazs to fall into the categories checked below. SYSTEM CONFORMITY (1-31: � 1 "CODE SYSTEM"M ISTS which meets all the location,duign and construction scandards of the cwtent Orono Munlcipal Code. 2 "COMPLIANT SYST'EM" An ISTS which daes not meet all the locatioa,daign and construction standards of the eurrent Orono Municipa! .Code but does mect the ttuee foot separarion requirement or two faot rcquirement for systems ir�stalled 1996 or earliet.and which is not failing or �an irsuninent threat to public health or safety. � "NON•COMPLIANT SYSTEM" A prohibited iSTS;an ISTS located within a daignated 100-year flood plain.any IS?S which may or may not meet all the location,design,or consuuction standazds of�e carrent Orono Munictpa]Code and which is fail'mg for any teason;and any ISTS with less than three feet of unsaturaud soil or sand between the distribution device and the limiting soil chazacudstics. TANK CO�IDITION(3:7): S � Tank inspection indicates: . � Pumpout not needed at this time. � 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped ), � blake sure seatic tanks are aumaed through manhole and not through�chite insaection oines This allo��•s for the arooer cleaning. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. DRAINFIELD CONDITION -�Q : �S 8 Dninfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. � 10 Drainfield is saturated and visibly dischargin�untreated effluent to the surface. Contact the City Inspector immediately.Repa'us must be completed within 90 days. , COvfi�NTS: Q�c,��C.:�\� �S �Oc.- Coc•.pl-,a��- a�e� n.vS�- be, c e Plqcec� �-r ��� � � to�o , lo =7 —o� �c� Date of Inspection Matt Boiterman— Septic System Inspector Note:In the event that this inspection rcport is used W satisfy the cequirements fo�a moctgage or other transfer o[properry.be advised that this cepoR does not guarantee or certiry�hat an existing rystem wi11 continue to function properly,but is merely an opinion ofthe adequary olthe system under eurrent conditions based on the availabte infocmation. CITY OF ORONO � O� Municipal Offices O O Post Office eox 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT r� � INSPECTION REPORT ti ��9kESH��'�G Owner:� / � �v�'v Address: %�� � �1 /�`'%� /�+�V�� D`../ Permit #'s: " Dates: f Contractors: City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site seuage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is�an existing system [ ] neu construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ 7 has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDIT[ON (5-10): Tank inspection indicates: 5 Purtipout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. 'fanks should be pumped out as soon as possible. System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface dischar�e. � Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next purtipout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation>. If tanks have not been pumped out uithin the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): ield inspection indicates: 11_ rainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS Cslope,setbacks.etc.): ��/L-f-���� POTENTIAL FOR SYSTEM FAILURE (depends on soils,uater table,etc.): ���� �,�G�� COMMENTS: � S�1 Yz t v}C i VI_�� a;� y� ` a�C�- S �/.�;a-✓1 G Sf �.•-� �� �CrZc: T�f� cr �' i 2- r-Zc�2� � Date of Inspec ion eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system uill continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system loc�tien and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner �°� . o :_, o �°� �� � CITY of ORONO � ����� �{� !4 Municipal Offices ,� � �,�;�� ;���,�n„ �'ti .t9 ,;r . `�¢.� SVeet Address: MailinQ Addrosr. $EggO 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: 1� � Address: 1305 3ixth Ave. N. Permit #'s: none Dates: Contractors: unknosvn (This is [�j an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. Q Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [�] or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] water tiqht or the condition is � unknown. If the tanks are not confirmed to be watertight, this classification is subject to revisson.) INFIELD CONDITION (11-14) : 11 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium COMMENTS: The septic system is non-compliant, but does not appear to pose an imminent threat to public health or safety (surface discharge or backup into the dwelling) . The system must be repaired or replaced by 12/31/2008 or within ninety days of posing an imminent threat to public health or safety, whichever comes first. � �� �- Date of Inspection p ic Syste ector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 '• FAX 473-0510 , CITY OF ORONO �O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SI�WA(�E TREATl�NT � � INSPECTION REPORT � Gtiti �9kESH.o�'� Owner: ! �1� Address: /.1V� . �l X7h .tf7/P„ /l/. � + Permit �'s: Dates: � Contractors: l��� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a reguler basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is�an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the enti�e current sewage inEwt without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which mey or may not meet all the location, design, and construction standards of the current City Codes end which is failing for any reason; .and an s " f " between the distribution device and the lim�tina soi characteristics. �j � e�°"r �3 7 �The limiting soil characteristic �has or [ ] has not been identified a�t t is time. If the limiting soil characteristic has not been identi � , this classification may be subject to revision.> TANK CONDITION (5-10): Tank inspection indicates: 5 P�mpout not needed at this time. 6 Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems. 7 Solids accunulation in tanks is at a critical level. 'fanks should be punped out as soon as possible. � System is discharging to the surface. Tanks must be punped out uithin 48 hours to eliminate surface dischar�e. Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next puipout. If tanks have not been p�mped out within the last three years, they should be punped out now. 10 Inspection pipe is located directl over tank baffle fdoes not give accurate me lids accunulation). !f tanks have not been pu�out aithin the last three years u punped out no . DRAINFIELD CONDITION (11-14): D�field inspection indicates: 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfietd is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. IIMITING SITE FACTORS (sloae.setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (decends on soils.water table.etc.): ���,� CO ENTS: � � � � S � Q. — � Date o Inspection S tic Syst�m nspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opin�on of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system locetion and punping records. WHITE COPY/Inspectora File YELLOW COPY/Homeowner On tbe North Sbore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT POST OFFICE BOX 66 � . � � 1335 S. Brown Rd. Crystal Bay,MN 55323 � 473-7357 OWNER Q✓�V � �V7� ADDRESS a� SJ ��1�-'• /'�' PERMIT NO.'S. � DATES ' CONTRACTORS ` City Ordinance No.210 requires that ead�on-eite sewage matment system in Orono be inspected on a regular basia.The onsite sewage treatment system at the above address has been in�ected and eppaan to fall into the category checked below. (This ia � an exiating sy:tem ❑ new conmuction) � � Meets or exceeda current City siandards in all respects relating to design,construction,and location.Appean to be operating PrW���Y. � 2 Does not meet all current City standards for new construction (1978 Codel but in most respects appears to be designed, loceted, and constructed generaliy ln accordance with previoua codea.System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Does not meet curre�t City standards in m�y respects relating to desig�,constructio�,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problema. No major upgrading of system is required at this time. � 4 System may or may not meet current City sta�dards for design,construction or location,but is faiiing to property treat and dispose of the current input,and is endangering a water supply,or is a sour�of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwite creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procxdures. If drainfield replacement is�ecesssry,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is atarted. SYSTEM CONDITION ( m Checked items may require your ection) Tank inspection indicatea: ❑ Inapection pipe is loceted directly over tank beffle.(Does not ❑ Pumpout not needed at this time. give accurate m�ureme�t of solids accumulation.) If tanks ❑ Solids aecumulation in tanks indicetea they should be pump� have not been pumped out within the la:t three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Soli� accumulation i� tanka ia at a critical level. Tanks Drainfield inspection indicates: ahould be pumped out aa aon es poseible. �Drainfield is dry,no surfacing evident. ❑ System ia discharging to surface. Tanka must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Dreinfield is saturated and visibly discharging untreated � ,� Inspection risers misting—tanks could not be inq�ected, effluent to the surface, This condition may require replace- Inapection risera (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contect the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repeirs muat be completed within 90 days. the IastJyear�,they shoutd be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil typea,water Future Expansion O Soil table,and system condition) �Adequate ❑ High water table �Low ❑ Fair ❑ Lot size ❑Medium ❑Poor ❑ Lake,wetland,or stream ❑ High . O Inadequate O Drainage ❑System is causing visible surface disctiarge. � � � COMMENTS: A '' -9 �ia-� Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does�ot guarentee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions bssed on the avaitable informatio�. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the NoYth Shore o f Lakc Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER �v`�'�-r � ADDRESS ��� S�X�f"� /�1V�ue No►�1y,, W�Z�1 PERMIT NO.'S. " DATES "LL CONTRACTORS � City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is l�an existing system ❑ new construction) � � Meets Q�f exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. �2 Does not meet all current City standards for new construction (1978 Codel but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design, construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrsding of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( � Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Dr in ield inspection indicates: should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet, within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated �Inspection risers missing—tanks could not be inspected. effluent to the surface. This condition may require replace- � Inspection risers (4" dia. pipel must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limi 'ng Site Factors Potential for System Failure Site Capabilities for �Slope (depends on soil types,water Future Expansion ❑ Soil table and system condition) Adequate ❑ High water table �Low �� ��Nf t<<n:S �t.l{, 'Fair ❑ Lot size �Medium� � ❑ Poor ��L�e,wetland,or stream ❑ High ❑ Inadequate ��Drainage ❑ System is causing visible surface discharge. COM M E N TS: ���� �/1�(��hYl/1.1/Yi(,� '�I,�[(,�2� !U GY1(,� ��1,Y',i�(,! c�-� l�1 L " ,L7 /U �(.i,�Ol�r�l 7 �vs�lu ►'�aU.c� _ � U��,-��. .�A��_� �.�m,� , �U.�t ��v�.a.Pc� j r�. l��D_ �,�.(. �-��-�� Date of Inspection eptic Sys pector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/ Inspector's File GOLD COPY/Homeowner On the North Shore of Lake Misznetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER 1�C���� �I 4�.��I /�i!v ADDRESS � ..S�Cj�SI - ,(t' fl� �_vE ;��� PERMIT NO.'S. � DATES CONTRACTORS � City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the ab�ov/e address has been inspected and appears to fall into the category checked below. (This is L7 an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly, � 2 Ooes not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. ❑ 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future probtems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( � Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle,(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. ❑ Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated v---� Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia, pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ----E� Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for �---� Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) ----�Adequate ❑ High water table ---�7 Low ❑ Fair ❑ Lot size ❑ Medium ❑ Poor ___.--� Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑System is causing visible surface discharge. COMMENTS: /'l tt U �.1 S� �:�- � ��O tc� � Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirem ts for a mortgage or other transfer ot property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the availabie information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner