City Ordinance l99 requires that each existing on-site sewage treatrnent system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORNIITY (1-3): �
1 "CODE SYSTEM"An IST'S which meets all the location,design and coostruc6on standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" M ISTS which dces aot meet all the location,design and construction standards of the current Orono Municipal
Code but dces meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent tlueat W public health or safety.
(3�"NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any LSTS which may
v or may not meet all the location,design,or construdion standards of d�e current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the d�stnbution device and the limiting soil characteristics.
TANK CONDII'ION(5-7): �
inspection indicates:
5 Pumpout not needed at this time.
Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 yeazs.
Tank was last pumped �'1�-03 ).
Make sure septic tanks are numaed through manhole and not through white inspection aiaes. This allows for t6e
proner cleanin¢. Keep water softner and iron filter discharge out of septic svstem.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed'm each tank. If
tanks have not been pumped out within the last ti�ree years,they should be pumped out now.
IELD CONDITION 5-10 : �
8 Drainfield is dry,no surfacing evident.
Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
Q�ti�;c\ >S r�o�-cv ��h��-- a� r�JS�- �� f c �c���c J
co�rrrs: � �Q
�� ��=��-Ze�o ,
�� >-�-�� �� .�
Date of Inspection Matt Bolte,nxian- Septic System Inspector
Note: In We event thatthis in�on report is used to astisfy tl�e requirements for a rtwrtgage a other transfer of property,be edvised that this report does not guarantx
or oertify mat�existing systan wilt c�ntin�x to function properly,but is rnerely an opinioa ofthe a�q�acy of the system under curnnt conditioas based on ttu availsbl
inforrna�on.
1�elephone(952)1A9-�600 • F�(452)249-4b16
�►v►w.d.oronoanac�
_�o �
i: � � `\,,
/ O 4 ��,
�� ;., ,, _ �, ciTY o� o�oNo
,�'. � �',' r �' ��,�� MunicipalOffices
,,,
`' '� �'�`; '�`� G ` Street Address: Mailing Address:
` .�9�E s�p4�� 2750 Kelley Parkway P.O. Box 66
���� O r o n o, M N 5 5 3 5 6 C rystal Ba y, MN 55323-0066
,..::::.:._____:�_=
To: The Current Owner of Address � 7 1 J s; I i,�CrV� �c�
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The onsite sewage treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes
No �
If yes,please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brought into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identi d as Non-Compliant
Yes
No
If yes, system must be brought into compliance by:
December 31,2007
December 31, 2010
Other '
Septic Tank(s) Pump out Needed
Yes �No
The City recommends the septic tank(s) and/or lift tank be serviced and pumped
out every three years. City records indicate the tank(s) were last pumped out on
� � (�-n 3 . The tank(s) should be cleaned through the manhole and
not through the inspection pipes,this allows for proper cleanina.
Comments:
r�
Inspect��° � �.� Date of Inspection �'a �
Telephone(9�2)2�9-4600 � Fax(952)249-4616
www.ci.�rono.mn.us
���
o , o
�'=a'� CITY of ORONO
i�k:y\�,
I���'� �u' �, I�l
v�! �� ��` ::: � Munici Offices
� � �. � �
P��� � �4�� G~ Street Add�ess: Mailin� Address:
�t i a5 r„ .�„�
''�'�HQ 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066
Owner: � Address: 2715 Silver View Dr.
Permit #'s: 1663 Dates: 2/22/89 Contractors: Clover Hill Co.
(This is �] an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level is [� or is not [ ] identified under this septic system. If the
saturated soil level is not identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 9 "
S Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
� Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are [ ] or are not [ ] water tight or the condition is [ ] unknown. If the tanks
are not confirmed to be watertight, this classification is subject to revision.)
INFIELD CONDITION (11-14) : 11
Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water table.
The separation is 0.8 feet and the system is non-compliant. Repair or replacement of the septic
system is required by 12/31/2009.
�����
Date of Inspection i ystem Inspect r
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone(612)249-4600 • Fax(612)249-4616
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal eay, MN 55323-0066 � � ON—SITE SEWA(�E TREAT�NT
r�,� . �C,, INSPECTION REPORT
'�� G~
'�k�sxo�'�
Owner: a � Address• P�� �
Permit �'s: Dates:_�Jif�— Contractors:
City ordinance nunber 100 requires that each on-site sewage treatment .system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked betow.
(This is �3,an existing system [ ] new construction)
STSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which mey or may not meet all the location, design, and construction standards of the current City
Codes and which is fail�ng for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic UQ has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identifieiJ, this classification may be subject to revision.)
TANK CONDiTION CS-10):
Tank inspection indicates:
Pumpout not needed at this time.
6 Solids acc tion in tanks indicates they should be out this year to help prevent future rob .
S accunu atio
8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate s �di e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be ins a in each
tank at next pumpout. lf tanks have not been pui�ed out within the last three years, they should be punped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation).
If tanks have not been p�mped out within the last three years, they should be punped out now.
DRAINfIELD CONDITION (11-14):
Dr field inspection indicates:
1 Drainfield is dry, no surfacing evident.
Sane evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City lnspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING S1TE FACTORS (sloce.setbecks.etc.):
POTENTIAL FOR SYSTEM FAILURE (decends on soils,water table,etc.): ��)
COMMENTS:
Date of nspection ep 'c System Inspector
Note: In the event that this inspection report is used to satisfy the require�nts for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
informatton.
This report must be kept on the pre�nises with the system locstion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(3E TREATMENT
v�,� h INSPECTION REPORT
'C�� G~
9kESH0�'�
owner: �Ol►'1L31,�� 1'��Y� Address: ��� . ,I 11/P1� I�PL•� ��
Permit #'s: Dates: ��—� Contractors: ��1��✓" ITI/I Co.
City ordinance number 100 requires that each on-site sewage treatment _system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(7his is V�an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
1 ��CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 5olids accumulation in tanks is at a critical level. Tanks should be punped out as soon as possible.
8 System is discharging to the surface. Tanks must be punped out Within 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. lnspection risers (4'� dia. pipe> must be installed in each
tank at next pumpout. If tanks have not been punped out within the last three years, they should be punped
out now.
1� Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been Fxmped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION C11-14):
D nfield inspection indicates:
1�] Drainfield is dry, no surfacing evident.
T2 Sane evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slooe.setbacks,etc.):
POTENT[AL FOR SYSTEM FAILURE (deaends on soils,water table.etc.): /��
L
COMMENTS:
Date of Inspection ic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certtfy that an existing system will continue to function
properly� but is merely an optnton of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system tocstion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
On the North Shore o f
Lake Minnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � � Crystal Bay, MN 55323
473-7357
OWNER r�'�'y�a'� ADDRESS ��/�.L�l�J�� v'�� �
PERMIT NO.'S. � -� DATES ��� CONTRACTORS
City Ordinance No.210 requires that each on-site sewage treatment system i�Orono be inspected on a regular basis.The onsite sewage
ueatme�t system at the above address has been inspected and appesrs to fall into the category checked below.
(This is �an existing system ❑ new construction)
� � Meets o�exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
� 2 Dces not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generaliy in accordance with previous codes.System appears to be functioning properly;no major
upgrading of Me system is required at this time.
� 3 Does not meet current City standards in many respects relating to design,construction,o�location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION (m Checked items may require your action)
Tank inspection indicates: ❑ Inapection pipe is located directly over tank beffle.(Does not
,�Pumpout not needed at this time. give accurate m�surement of solids eccumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump� have not been pumped out within the last three years,they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon aa possible. �Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Ta�ks must be pumped Some evidence of surfaci�g,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated
❑ Inspection risera missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risen (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
O Slope (depends on soil types,water Future Expansion
� Soil table,and system condition) `�Adequate
❑ High water table �Low ❑ Fair
❑ Lot size Medium O Poor
❑ Lake,wetland,or stream ❑ High ❑ Inadequate
❑ Orainage ❑System is causi�g visible
surface discharge.
COMMENTS:
�-a9-�
Date of Inspection eptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this repo►t does not guarentee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner