City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTENI CONFORNIITY (1-3): �
1 "CODE SYSTEM" An ISTS which meets all the location,design and constructiou standards of the current Orono Municipal Code.
2 "CO1vIPLIANT SYS'I'EM" An ISTS which does not meet all the location,design and construction standards of the cuRent Orono
Municipal Code but does meet the three foot sepazation requ¢ement or two foot requirement for systems installed 1996 or earlier,and
rvhich is not failing or an immiaent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
er may no!neet all the location,design,or conshvction stanc�trds of tl�e current Orono Municipal Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distributinn device and t6e limiting soi]characteristics.
TANK CONDTTION(5-71: �
Tank inspection indicates:
� Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code reco.mmends tanks to be pumped out onee every 3 years.
Tank was last pumped �• 1 �=P-�o� ).
Nlalce sure septic tanks are pumaed throu�h manhole nnd not throu2h�vhite inspection aiaes. This allows for the proaer
cleanine Keep�vater softner and iron filter dischar�e out of seatic svstem to prolon�life of drainfield. Ask aumper to test
alarm float to verifv alarm is stil!�vor[cin�in your house. The alarm warns owner that septa¢e is flbout to backup into basement.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanl:s have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITTON(3-10): c�
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly dischar?ino untreated effluent to the surface. Contact the City Inspector
immediatzly.Repairs must be completed within 90 days. �
�
7 �— � � '�' ' �' '
�'c���IMF�TTS� ����t. 1 � � KS �.i ,lll� U�
� y �fr ' U� ��j ` ��
71...�..F T..,...�..,..... Canlir Cvernrn Tncn�rfn.
o ������
;-
� � ,�
;�;�O � O �� �
'� ' ` CITY of ORONO
� -_ ;
�� � }a
,�� ,� �; t�r �,�.
.�'„ `f',��}, ,'��`; ., . �lS� ' Municipal OtTices
�� '� �r� � �,
`\� �' ';.�',r+`�°;`���' G/%� Street Address: MailinQ Addross:
�\$�Eg�% 2750 Kelley Parkway P.O. Box 66
--- Orono, MN 55356 Crystal Bay, MN 55323•0066
To Current Owner: Address: ��� S `��� �'`�J �'^' ��,
Ciry Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-31: �
�"CODE SYSTEM" An[STS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which dces not meet all the location,design and consVuction standards of the current Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or conswction standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7): �
Tank inspection indicates:
5 Pumpout not needed at this time.
�Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped 6, �°�'�1 ).
Make sure seatic tanks are aumaed throueh manhole and not throueh white inspection oipes This allows for the
aroper cleaning. Keea water softner and iron filter dischar¢e out of septic svstem.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia. pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
D INFIELD CONDITION(8-10): �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
' � 1oaK..� . ��� fiCt�S o� t�.�� �e:r
COMMENTS: i'�0�..� o K ^� -� f oQfS
C,\�cl P:�'� - Y�� s�ec� 3-c tt�\�ic� fio c�pS 0� pvtip �.,�C_
S J'( Sr*,�� ' "v.,c�}tr h Z�r:�', :�.ro t�c�k5 . 5 c.o•,,. c C� qt� :r-r� ��K S �-
XC tQ.2c- '�-�^ �^ `""=�C' _
q-��-0� '�`'�� ��tS�'�i�+�-�
Date of Inspection Matt Bolterman - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy of the system under current conditions based on the available
information.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
.�,o,�.
o..:.�� o
��:r��� CITY of OR0�1T0
1� t��' .i. n:'=I �
� ���=. �;: . Muakipal Ot�ices
� ~
�r�+.��,�,a`� �G Street Addrou: M�11in�Addross:
E'8�i4g 2150 Kelley ParlcwaY P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: �al•� C)���.�Mqn Address:_330 S�,�Vt� MeqJo..,,. pC'
City Ordinance 199 requires that each e�sting on-site sewage�eatment system in Orono be inspected every nvo years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked belo�v.
S STEM CONFORI�Il'TY 1-3 : �
1 "CODE SYST'EM" M ISTS which meets ail the tocatioq daigt aad rnast�uction standards ofthe current Orono Municipa(Code,
2 "CONfPLIANT SYSTEM" An ISTS which does not med a!1 the(ocatioq design and constiuction standards ofthe c.vnent Orono Municipal
Code but does meet the three foot separation«quuement,and which u aot failiag or aa imminent threat to public health or aafety. •
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a daignated 100-year tlood p(ain,any IST'g which�ay
or may not med all the locatioq design,or coastcuctioa staadards of the cuaertt Orono�funicipal Code and which u failing for any rcazoe;aad
any ISTS with las than three feet of unsaturated soil or sand betwan the disuibutioa device and the limiting soil charactecistics,
r
T.4MC CONDITION(5-10): b
Tank inspection indicates: •
� Pumpout not needed at this time.
6O Tank must be pumped out this year (city code requiras tanks to(x pumped out evay 3 yeacs. Tank wbs last pumped 3-a-9� ).
7 Solids accumulation in tanks is at s aitical a critic�l IeveL Tanks shoutd be pumped out as soon as possibla.
8 System is discharging to the surface. Tacilcs must be pumped out within 48 ho�us to eliminate surface dischacge.
9 InsPection risacs missing-tanlcs Could not be inspected Lupection risecs(4"dia,pipe)must be iruttalled in each taak at next pumpout If tanks
have not bean pumped out within the last three yeazs,they should be pumped out now.
1� Inspection pipe is located directLy over tank ba@la(does not give accurate meacuroment of solids accumulation). If tan(cs have not been pumped
out within tha lau three years,they should be pusaped out now.
DRAINFIELD CONDTTION(11-14): l �
1�Ihainfield is dry,ao surfacing evident
12 Some evidence of surfacing,not ctitical yet
13 Drainfiald is saturated and visibly discharging u�reated e�lurnt W ihe sucface. Contact the City Inspector immediately.Repaus must be
completed within 90 days.
1-� Drainfield estent and condition wilcnoKn. `
CO1VI��NTS: S S� �ootC.S d k . Cov�� �^5 �, -,o� ; d� uh.
'C°��.�--- {�v^..p �-�a� 5 •
Q-�-�o� ��
. Date of lnspcction :
Septic System Inspector
Notr. In t!u event thac this inspection teport is used tu sat�{y�����for a moRgage or otha traasfa of property,be advised that this repoR doa not guarantee
or cectify that an e�sting system will coatinue W function propaly,but is mere(y an opiaioa of the adequacy of the syscem uada cvnent roaditions based on the availablo
informatioa
�°�
��o 0
��{� � ���
-� :�� CITY of _ __ _ �1T0
' a��l
i � �� r�*� �
�� � f�`.��3 � � Municipal Ot'fices
� "�`'✓'�,�'w 4 a� G
'Str��i AYYr�ss: MaiUn�Addrass:
���KQ�'w 2150 Kelley Parkway P.O, Box 66
-- Orono, MN 55356 Crystal Bay, MN 55323•0066
I
Owner: Address: 330 Silver Meadow Dr.
Permit #'s: 1477 Dates: 11/23/88 Contractors: Patnode Bros. j
(This is [� an existinq system ( ] new construction) .
,SySTEM COMPLIANCE (1-3) : 1
1 Code System: Meets or exceeds current City standards in all respects relatinq to design, i
construction, and location. Appears to be operating properly. i
2 Compliant System: Does not meet all current City standards for new construction, but in '
most respects appears to be designed, located, and constructed in accordance with previous �
codes and is functioning properly. ,
3 Non-Compliant System: System may or may not meet current City standards for design, ;
construction, or location, but is failing to properly treat ar.d dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of �
the drainfield and the saturated soil level.
(The saturated soil level is [�] or is not [ ] identified under this septic syatem. If the ,
saturated soil level is not identified, thia classification is subject to revision.)
K CONDITION (5-9) : 5
5 Pumpout not needed at this time. �
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours. �
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now. �
9 Inspection pipe is located 'over tank baffle-can not measure solids accumulation. If tanks '
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant. '
(The tanks are [ ] or are not [ ] water tight or the condition is [�] unknown. If the tanks
are not con£irmed to be watertight, this classificstion is aubject to ie�sion.)
INFIELD CONDITION (11-14) : 11 i
1 Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact �
the City Inspector immediately. Repair must be completed within 90 days. �
14 Drainfield extent and condition unknown. �
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low
CONIl�IENTS: In order to confirm that your septic system meets Minnesota standards, soil borings �,
were performed to verify a 3 foot separation between the drainfield and the seasonal water table.
The separation is 3 feet and the system is compliant.
-�-q�
Date of Inspection ep ic System Inspector
Note: In the event that this inspection report is used to satisfy • the requirements for a
transfer of property, this report does not guarantee that an existinq system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone(612)249-4600 • Fax(612)249-4616
CITY OF ORONO � O�
Municipal Offices O O
Post Office eox 66
Crystal Bay, MN 55323-0066 � � ON—SITE SIRWA(;L TREATb�NT
� ti INSPECTION REPORT
'�� G~
9kESH�4�
��n�, //
Owner• � r II C.f�''�Address• � ! �
Permit #'s: Dates: ��o�J o C� Contractors: �J D�
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is �an existing system [ ] new construction)
SYSTEM CONFORMiTY 1-3 :
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM��-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting sotl characteristics.
(The limitin� soil characteristic ,p9..has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi�ied, this classificatio� may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
� P�npout not needed at this time.
Solids ' ' 'ndicates ey should be out ture roblems
s accumulation in tanks �s a an s s ou d be pixnped out as soon as possi e.
8 System is discharging to the surface. Tanks must be p�miped out within 48 hours to eliminate surface dischar�e.
9 [nspection risers missing-tanks could not be inspected. lnspection risers (4" dia. pipe) must be installed in each
tank at next p�mpout. If tanks have not been punped out within the last three years, they should be punped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation).
If tanks have not been pimped out within the last three years, they should be pu�ed out now.
DRAINFIELD CONDITION (11-14):
D�e�fietd inspection indicates:
/11/ Drainfield is dry, no surfacing evident.
`rT2 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City lnspector
immediately. Repeirs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slooe,setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE (deoends on soils.water table,etc.): 1���
CO :� � �j
Date of Inspection Se ic System nspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
informat�on.
This report must be kept on the premises with the system locstion arid Fxmping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeow�er
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(iE TREATl�NT
r�`,� � INSPECTION REPORT
'�� G~
9kESH��'�
L ? i
Owner:��0/)� 1�n'Y1���Address• J�� 1!
Permit #'s: Dates: ��d�.�'� Contractors:
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is � an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
"CODE SYSTEM'�-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface uaters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting sotl characteristics.
(The limiting soil characteristic ,[� has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be p�xnped out this year to help prevent future problems.
Solids accumulation in tanks is at a critical level. 'fanks should be p�rnped out as soon as possible.
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next Fxmpout. If tanks have not been pumped out within the last three years, they should be punped
out now.
70 [nspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation).
If tanks have not been pimped out uithin the last three years, they should be punped out now.
DRAINFIELD CONDITION (11-14):
D�field inspection indicates:
1 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (sloae.setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (deaends on soils.water table,etc.): �
COMMENTS: � '' g S�
Date of Inspection Se ic System Inspector
Note: ln the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
informat�on.
This report must be kept on the premises with the system location and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
On the North Shore o f
Lake Minnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � � Crystal Bay, MN 55323
473-7357
OWNER ✓��� �✓T'rQr��� ADDRESS O a
PERMIT NO.'S. !�/ DATES `����o CONTRACTORS S�JL[��
City Ordinance No.210 requires that each on-site sewage treatment system in Orono be i�spected on a regular basis.The onsite sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is �an existing system ❑ new construction)
�]I� Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
��" properly.
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
loceted, and co�structed generaliy in accordance with previous codes.System appears to be functioning properiy;no major
upgrading of the system is required at this time.
� 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public�uisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testi�g will usually be required,and a design and site plan
must be submitted for review.Your co�tractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not
❑ Pumpout not needed at this time. give accurate measurement of solids eccumulation.) If tanks
�Solids aecumulation in ta�ks indicates they should be pump� have not been pumped out within the last three years,they
ed out this year to help prevent future problems, should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drai field inspection indicates:
should be pumped out as soon es possible. �Dreinfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to elimi�ate surfaoe discharge, ❑ Orainfield is saturated and visibly discharging untreated
❑ Inspection risen missing—tanks could not be i�spected, effluent to the surface. This condition may require replace-
Inspection risero (4"dia.pipe)muat be installed i�each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the laat three years,they should be pumped out now. ❑ Drainfield extent and condition unknown,
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Futu Expansion
O Soil table and system conditionl �Adequate
�High water table �Low ❑ Fair
Lot size ❑Medium O Poor
❑ Lake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage ❑System is causing visible
surface discharge.
COMMENTS:
�/
Date of Inspection ptic System Inspector
Note: In the event that this inspection report is used to satisfy the requireme�ts for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current co�ditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOID COPY/Homeowner
On tbe Nortb Sbore o f
Lake Minnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
� . � � 1335 S. Brown Rd.
Crystal Bay,MN 55323
473-7357
OWNER ��a?�'1 C�FiY'r'V1�QY� ADDRE��/�Pilr /"/LAdI�..J D�
PERMIT NO.'S. ��y�- DATES l�a�g� CONTRACTORS
City Ordinance No.210►equires that eech on-site sewage treatment system in Orono be inspected on a regular baais.The onsite sewage
t�tment system at the above eddress has been inspected and appeers to fall into the cetegory checked below.
(This ia 1ai an exi:ting system ❑ new consuuction)
� � Meeu or excesda current City standarda in all respects relating to design,construction,and location.Appears to be operating
properly,
� 2 Does not meet all current City atandards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordence with previous codes.Syatem�pears to be functioning properly;no major
upgrsding of the system is required at this time.
� 3 Does not meet current City standarda in many respects relating to design,construction,or location.Appears to be operating
adequately at this time,but has a relatively high potential for future proWems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City atanderds for design,construction or location,but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of pollutio� to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replecement ia necessary,soil testi�g will usually be required,a�d a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is atarted.
SYSTEM CONDITION (m Checked items mey require your action)
Tank inspection indicates: ❑ Inapection pipe is located directly over tank bsffle.(Does not
,�Pumpout not needed at this time. give accurate m�surement of solida accumulation.) If tanks
❑ Solids accumulation in tenks indicates they should be pump� have �ot baen pumpsd out within the last three years,they
ed out this yeer to halp prevent future prodems. should be pumped out now.
O Solids accumulation in tanks is at a critical level. Tanks Dreinfield inapection indicates:
should be pumped out as soon aa posaible. � Oroinfield is dry,no aurfacing evident.
❑ System is diacharging to surface. Tanka must be pumped O Some evidence of surfecing,not critical yet.
within 48 houn to eliminate aurface di�harge. O Drainfield ia aaturated and visibly discharging untreated
❑ Inspection riaere miaing—tanks could not be inapected, effluent to the surfece. 7his conditio� mey require replace-
Inspection rifen (4"dia.pipe)must be inatsHed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanlcs have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they:hould be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table,and system condition) �-Adequate
❑ High water table �Low ❑ Fair
O Lot size ❑ Medium ❑ Poor
❑ Lake,wetland,or stream ❑ High . ❑ Inadequate
❑ Drainage ❑System is causing visible
surface discharge.
COMMENTS:
�
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requireme�ts for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existi�g system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available informatio�.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner