HomeMy WebLinkAboutseptic info � °� � � �
o :. o .
�:y����: . �I7�Y of �RUNO
r� ,+�!��`'T��` ': �+
� ; �; "'�� f„ Municipal Offices
;Y ����:.:_�
`�� ,�, �� �,,, 'r ���� �ti G / o O
�:��'` � � i
� ��.:- �".��� ��� Street Address: �15a'a49'�16 Mailing Address:
� ,� ...��.��.�,.�� �,i/ .
�`\`q$�SKpg',;'' 2750 Kelley Parkway P.O. Boz 66
��--�' Orono, MN 55356 Crystal Bay, MN 55323•0066
To Current Owner: Address: 3� � 5�1 U� /��� �C���
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the cateoories checked below.
SYSTEM CONFORMITY (1-3): `
1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
Z "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
Niunicipal Code but does meet the three foot separation requaement or two foot requirement for systems installed 1996 or eazlier,and
which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLTANT SYSTEM" A prohibited ISTS;an ISTS locnted�vithin a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of tlie current Orono Municipal Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and thc limiting soil characteristics.
TANK CONDITION(5-71: �
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tanl:was last pumped �-� "l:J � �.
11�Ialce sure septic tanks are pumped throush manhole and not throu�h white inspection nipes. This allows for the aroper
cleanine. Keep water softner and iron filter disch�rQe out of septic svstem to prolonE life of drainfield. Ask pumper to test
alarm float to verifv alarm is still workin�in vour house. The alarm warns owner that septnee is about to backup into basement.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DR.AINFIELD CONDITIOIv'(5-10): �c5
S Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly dischar�ing untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days. i
3
�nM��IE�TTS:
�
�- l (� CC:.;J �
T...� ..:7_��».:..� Ce...:., c..�.a.., r......�,.«,..
�°� �
o ,:� : o
���:�-� ::_,�. CITY o� ORONO
. "� ,',���;��� Nt�� o���
�,t, �,. �
G Street Addresa: Mailin� Addreu:
1 � `r�
� F���� �"� 2150 Kelley Parkway P.O. Box 66
'�'EggO
4rono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: 3�S s;�v(( Mc�a�w ��
City Ordinance 199 requires that each existing on-site sewage treaiment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
YSTEM CONFORNIITY 1-3 : i
"CODE SYSTEM"M ISTS which meets all the location,design and construction stat►dards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Oroao Municipal
Code but does meet the ttvee fioot separation requirement or two foot requirement for systems instailed 1996 or earlier,end which is not failing or
an imminent threat to public health or safety.
3 'NON-COMPLIAIVT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standerds of the current Orono Municipal Code and which is failing for atry reason;and
any ISTS with less than three feet of unsaturated soil or sand between d�e distribudon device and the limiting soil characteristics.
TANK CONDITTON(5-7): �
T inspection indicates:
5 Pumpout not needed at i�is rime.
Septi+e tanks must be pump�out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped 1—d3 ).
Make sure sentic tanks are pumned through manhole and not#hrough white inspection fli�es. This atlows for the
proaer cleanin¢. Keen water softaer and iron filter discharge out of sevtic svstem.
7 Inspection risers missing-tanks could not be inspected Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within�e last du�ee yeazs,they should be pumped out now.
DRAINFIELD CONDITION(8-10): �
Drainfield is dry,no surfacing evident.
Some evidence of surfacing,not critical yet.
Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMII�NTS: M q� Sc ��- ��1c.S aDIL � ',�o.� C��
C v ;� c c.�-r� , � sd�- o� c�.d� � h� ur c �-�v
p J�r- c�,D S c� � �cS�� v.,. c v�-- �c h-
�
����U� �� ��
Date of Inspection Matt Bolterman- Septic System Inspoctor
No�:Ia tde event thatt6is i�on report is used to sffiisfy Uu re9uiroments for a mortgage or aRher transfer of propercy,be advised ffiat this ropat does not guaranroee
�oeKify tf��exLsting system will continue to functioa properly,but is merely�opinion oftlie adequs�y of tlu system under current condidons based on the available
information.
17elephone(952)249-4G00 • Fax(952)249-4616
vrww ci.orono.mn.�
� o�
O `;.'a O
���:;��.' ,� CITY of ORONO
� r
x. 5 ,;��'
"�• 1 �'-,� ,-, ,y,�' Municipa! OtTices
,�, �� � ,�
'!��''��1�' G Street Addross:
� , ����Og� 2150 Kelle Parlcwa Mailin�Address:
ES�I Y Y P.O. Box 66
Orano, MN 55356 Crystal Bay, MN 55323-0066
Owner: �N��\��q M �f V n:nq Address: 31S S:IvCr MQ4�ow. Dr
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every rivo years.
The on-site sewage treatment system at the above address has been inspected and appeazs to fall into the categories checked below.
SYSTENi CONFORI�IITY (1-3): 1
lO °CODE SYSTEM" An ISTS which mcets all the location,design and construction standards of the cuarnt Orono Municipal Code.
2 "CONiPLIANT SYST'EM" An ISTS which does not meet all the locatioq desigi aad construction standards of the cunent Orono Municipal
Code but does meet the three foot separation requuement,and which is not failing or aa imminrnt threat to public health or safety.
3 "NON-COMPLIANT SYS'TEM" A prohibited ISTS;an ISTS located withia a daignated 100-year IIood plain,any ISTS which may
or may not meet all the(ocatioq design,or construction standard4 of the currrnt Orono�,funicipal Code and which is failing for any reacon;and
any ISTS with less thaa three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
T.�NK CONDITION(5-10): S�
Tank inspection indicates:
OPumpout not needed at this time.
6 Tank must ba pumped out this year (city code requires tanics to be pumped out every 3 years. Tank was l�st pumpad �_��� l 7 �
7 Solidc accumulation in tanks is at a criticai a critical leveL Tanks should be pumped out ac soon as possibla.
8 Systam is dischar3ing to tha surface. Tariks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspectioa risats missing-tanks could not be inspected Inspection risen(4"dia pipe)must be installed in each tanlc at next pumpout If tanks
ha�•e nut been pumped out withict the last three years,they should be pumped out now.
10 InspeMion pipe is located directly over tank ba�le(doas not give accurate measurement of solids accumulation). If tanks have not bern pumped
out within tha last three years,they should be pumped out now.
DRAINFTELD CONDITION 11_14): I)
11 Drainfield is dry,no surfacing evident
12 Soma evidence of surfacing,not critical yet
13 Drainfiald is saturated and visibly discharging untreated eglurnt to the surface. Cornact the City Inspector immediate(y.Repairs must be
complatad within 90 days.
1� Ihai�ald e�ctent and condition unknown.
COM�NTS: S Ste� �oo�S 0� , 01� �o��d d-�c� r�o n,ee.�'
- 5�xb�c� r e.a v-. �� m�c.��-- N�� 'a.4 �c�' -ro 1 o-r 1:�� a�
�'`� Q.55e.r..e�t .
q-4 - o t �yy��d
Dau of Inspection Septic System Inspector '
Note: In the evrnt that this inspection repoR is used W satitfy the requirements for a mortgage or othc traasfar of propeRy,be advised that this repod does not guarantae
or cectify that an existing system will continue to function properly,but is merely an opinion of the adequary of the system under cuaent coaditions ba4ed on the availablz
informatioa
'�,O,�
O�, , O
,#,���;.� � CIT��� ORONO
-� ti M���� offi�
� f��,���,���� ti
\ '���� r `�`�,�G Street AddreSS: M�t!!n�Addross:
�\'�'�Hp�" 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323•0066 '
� f ;
Owner: � Address: 315 Silver Meadow Dr.
Permit #'s: 1495, 3938 Dates: 12/5/88, 9/12/91 Contractors: American S 6 W, 3ullivan j
(This is (� an existing system [ ] new construction) . I
SYSTEM COMPLIANCE (1-3) : 1 '
1 Code System: Meets or exceeds current City standards in all respects relating to design, I
construction, and location. Appears to be operating properly. ;
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous �
codes and is functioning properly. i
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of I
the drainfield and the saturated soil level.
(The aaturated soil level is X] or is not [ ] identified under this septic system. if the
saturated soil level is not idantiPied, this clasaification is subject to reviaion.) �
�K CONDITION (5-9) : 5
5 Pumpout not needed at this time. �
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out �•��thir 4? hours. �'
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out �
within three years, they should be pumped out and risers installed now. ;
9 Inspection pipe is located 'over tank baffle-can not measure solids accumulation. If tanks !
have not been pumped out within three years, they should be pumped out now. !
10 One or more tanks are cesspools, which means the septic system is non-compliant. ,
(The tanka are [� or are not [ ] water tight or the condition is [ ] unknomn. If the tanks �
are not confirme o be watertight, this classification ia subject to revision.)
INFIELD CONDITION (11-14) : 11 I
1 Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact I
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown. ;
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low
CObIl�lENTS: '
U � / I
Date of Inspec ion ic System nspect r
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing �system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone(612)249-4600 • Fax(612)249-4616
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 a � ON—SITE SEWA(;E TREATMENT
INSPECTION REPORT
ti
ti
��9k o��G
�sx
/
Owner• � ��� 1� Address• �
� h
Permit #�'s: Dates: ontractors: / �/ J�
City ordinance nu�er 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is � an existing system [ l new construction)
SYSTEM CONFORMITY C1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system wh�ch does not meet all the location, design, and construction standards of the
current City Codes, but Was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONfORMING SYSTEM"-A prohibited system; a system located uithin a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the curre�t City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limitin� soil characteristic �has or [ ] has not been identified at this time. It the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION C5-10):
T,an�jc inspection indicates:
/ y' Pumpout not needed at this time.
v6 Solids acc�mulation in tenks indicates they should be p�mped out this year to help prevent future Problems.
7 Solids accumulation in tanks is at a critical level. Yanks should be punped out as soon as possible.
8 System is discharging to the surface. Tanks must be p�n�ed out within 48 hours to eliminate surface dischar�e.
9 lnspection risers missing-tanks could not be inspected. [nspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. 1f tanks have not been pu�ed out within the last three years, they should be p►mped
out now.
10 Inspection pipe is loceted directly over tank baffle (does not give accurate measurement of solids accunulation>.
If tanks have not been puqx�d out within the last three years, they should be punped out now.
DRAINFIELD CONDITION (11-14):
D field inspection indicates:
11 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE fACTORS (sloce.setbecks,etc.):
POTENTIAL FOR SYSTEM FAILURE (deoends on soils.water table,etc.):
COMMENTS:
Date of Inspection ep System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or cert�fy that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
�nformetion.
This report must be kept on the premises with the system locetion and pumping records.
WHITE COPY/Inspectora File YELLOW COPY/Homeowner
CITY OF ORONO �O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATl+�NT
� . � INSPECTION REPORT
ti
��9kESH0��G
Owner: .��]�� L�A�ILI� Address:__��� .�/I/F°l� / ►'1`�� �r.
�
Permit �'s: Dates: — — Contractors: iN7 4-
�� S!/ ✓4�15
City ordinance number 1 0 requires that each o�f-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is �an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
"CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface uaters.
3 ��NON-CONFORMING SYSTEM��-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic �has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDIT[ON C5-10):
Tank inspection indicates:
5 Punpout not needed at this time.
6 Solids accunulation in tanks indicates they should be punped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e.
9 Inspect�on risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next purtipout. lf tanks have not been punped out within the last three years, they should be punped
out now.
� Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation).
If tanks have not been puq�ed out within the last three years, they should be pumped out now.
DRAINfIELD CONDITION (11-14):
Dr�field inspection indicates:
[11) Drainfield is dry, no surfacing evident.
'IZ Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
lIM1TING SITE FACTORS (slope,setbacks,etc.): k�
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): L�>
COMMENTS:
='S�/��
Date of Inspection ep c System Insp ctor
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system location and punping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
On the North Shore o f
Lake�Ninnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � Crystal Bay,MN 55323
473-7357
OWNER v v�h ���r��� ADDRESS ��� ,,,2)!�°tr ���
PERMIT NO.'S. / � �`� DATES I���� CONTRACTORS W
City Ordinance No, 210 requirea that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage
treatment system at the above address has been inapected and appears to fall into the category checked below.
(This is �an existing system ❑ new construction)
�� Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly,
� 2 Does not meet all current City standards for new construction (1978 Codel but in most respects appesrs to be designed,
located, and co�structed generally in accordanc�e with p�evious codes.System appears to be functioning properiy;no major
upgrading of the systern is required at this time.
� 3 Dces not meet current City standards in many respects relating to design,construction,or location.Appears to be operating
adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design,construction or location,but is failing to properly treat and
dispote of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.PleaSe contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,a�d a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION (m Checked items may require your action)
Tank inspection indicates: ❑ Inapection pipe is located directly over tank baffle.(Dces not
'�-Pumpout not needed at this time, give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they ahould be pump� have not been pumped out within the last three years,they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level, Tanks Drainfield inspection indicetes:
ahould be pumped out as soon as possible. �Drainfield is dry,�o surfacing evident.
O System is discharging to surface. Tanka must be pumped O Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge, ❑ Orainfield is saturated and visibly discharging untreated
❑ Inspection risen missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risere (4"dia.pipe)must be instslled in each tank ment or additionc to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the laat three years,they should 6e pumped out now. ❑ Dreinfield extent and condition unknown.
SITE CHARACTERISTICS: �
Limiting Site Factors Potential for System Failure Site Capabilities for
O Slope (depends on soil types,water Future Expansion
Soil table and system condition) �..Adequate
High water table �Low ❑ Fair
❑ Lot size ❑ Medium ❑Poor
❑ Lake,wetla�d,or stream ❑ High ❑ Inadequate
❑ Drainage ❑System is causing visible
surface discharge.
COMMENTS:
� �
Date of Inspection eptic System Inspector
Note: �n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify thas an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner
On the North Sbore of
Lake�Iinnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT POST OFFICE BOX 66
� _ � � 1335 S. Brown Rd.
Crystal Bay,MN 55323
� 473-7357
OWNER �„�11'� �/L'� ���,UP)/ �t�! G�i.J �
AODRESS � �
PERMIT NO.'S. �1�� DATES �C�` _> —� CONTRACTORS � �
City Ordinance No.210 requires that each oniite sewage treatment system in Orono be inapected on a regular basis.The onsite sewage
treatment system at the above addreas has bee�inspected and appears to fall into the categay checked beiow.
IThis is � an exiating system ❑ new conatruction)
� � Meets or exceeds current City atandards in all respecta relating to design,construction,a�d location.Appears to be operating
properly.
� 2 Does not meet all current City standerds for new construction (1878 Code1 but in most respects appears to be decigned,
located, end conatructed generelly in accorda�ce with previous codes.System appears to be functioning properly;no major
upgrading of Me system is required at this time.
� 3 Does not meet current City standarda in many respects relating to desig�,construction,or location.Appears to be operating
adequately at this time,but has a relatively high potential for future problema. No major upgrading of system is required at
thit time.
� 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a sefety hazard,or is otherwiae cresting a public nuisance.Ptease contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usuelly be required,and a design and site plan
muat be submitted for review.Your contractor must obtain a permit before work is started. "
SYSTEM CONDITION (m Checked items may require your action)
Tank inspection indicatea: ❑ Inapection pipe is located directly over tank baffle.(Does not
� Pumpout not needed at this time. give eccurate m�aurement of solids accumulation.) If tanks
❑ Solid�accumulatio� in tanks indicetea they ahould be pump- have not been pumped out within the last three yeers,they
ed out this year to help prevent future problema. should be pumped out now.
❑ Solids accumulation in tanka is at a criticel level. Tanks Drainfield inspection indicatea:
should be pumped out ae won�posaible. �,� Droinfield ia dry,no:urfecing evident.
❑ System is diacharging to aurface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Oreinfield is saturoted and visibly discharging untreated
❑ Inspection rieera missing—tanka could not be inspected, effluent to the aurfs�. 7his condition may require replace-
Inspection ri�ra (4"dia.pipe)muat be inatslled in each tank ment or additions to drainfield. Contact Me City Inapector
at next pumpout. If tanka have not been pumped out within immediately.Repeirs must be completed within 90 days.
the laat three yeara,they should be pumped out now. ❑ Drainfield exte�t and condition unknown.
SITE CHAHACTEFiISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table,and system condition) �Adequate
❑ High water table �Low ❑ Fair
❑ Lot size ❑Medium ❑Poor
❑ l.ake,wetland,or stream ❑ High . ❑ Inadequate
❑ Drainage ❑System is causing visible
surface discharge.
COMMENTS: � / � � l� l� I�
v �/I/II✓� .
9"ao-�Q
Date of Inspection Septic System Inspector
Note: In the event that this inapection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner