HomeMy WebLinkAbout2015-00460 - plumbing CITY OF ORONO *2 0 1 5 — 0 0 4 6 0 * ' 2750 KELLEY PARKWAY DATE ISSUED: OS/OS/2015 � ORONO, MN 55356- 952 249-4600 FAX: 952 249-4616 ADDRESS : 3880 SHORELINE DR PIN : 17-117-23-33-0151 LEGAL DESC : LTNPLATTED 17 117 23 : LOT 000 BLOCK 000 PERMIT TYPE : PLUMBING(>$500) PROPERTY TYPE : COMMERCIAL-BUSINESS CONSTRUCTION TYPE : FIXTURES-MULTIPLE NOTE: 3 WATER CLOSETS,2 LAVATORY,2 SHOWER, 1 KITCHEN SINK, 1 SILCOCKS,8 FLOOR DRAINS,2 LAUNDRY TUB, 1 WATER HEATER, 1 FLAM TANK& 1 DRINKER VALUATION OF PLUMBING 107000 APPLICANT PLUMBING FIXTURE FEE 1,337.50 STATE SURCHARGE PLBG(VALUATION) 53.50 NORTHERN MECHANICAL MAIL-IN FEE 2.00 1975 SENECA RD TOTAL 1,393.00 EAGAN, MN 55122- (651)789-2275 Payment(s) CREDIT CARD 1930 1,393.00 OWNER Hennepin County A 1730 GOVERNMENT CTR 300 S 6TH STREET MINNEAPOLIS, MN 55487- AGREEIvIEN'�AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which cequires separate permiu. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construc[ion authorized is not commeneed within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring alI required inspections are requested in conformance with the State Building Code.This permit may be revoked at any time for due cause. i'U� .}�Q r / f; c,�� (��-�v�-v�_c,`� � �s � 1 S Applicant Permitee Signature Date Issued By Signature Date FOR CITY USE ONLY ' .� ����. City of Orono ,�� �� �� � �� /'1, i� /'� P.O.Box 66 Date Received:�ZZ�/l7 Permit# � �V ti.J 2750 Kelley Parkway r� Crystal Bay,MN 55323 Approved By: !�' '� Amount$: -6� ' (952)249-4600 Main �`<< � � � (952)249-4616 Fax �� �/s� CITY OF ORONO— PLUMBING PERMIT � � �� ����`������ � (All Commercial Pernlits Must be Approved by the State Prior to City Approval) � htt�:ll����1�w�.dli.mn.�o�!CCLD;NDI�i�c �lumb lanrc�a> >. �d�f GENERAL INFORMATION 1. You may apply for plumbing permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Plumbing permits may be issued ONLY to licensed plumbing contractors and to property owners residing in the dwelling. 4. When any new construction or remodeling is involved,a separate building permit must be obtained. 5. All work must be done in accordance with State Code requirements. 6. All work must be inspected and air tested before it is covered. Call(952)249-4600. (24-48 hour notice required) TYPE OF PERMIT Check All That A 1 ❑ Residential �Commercial (Approval Required) ❑ New �Additional ❑ Repairs ❑Replace ❑ In Accessory Structure? *You will need nrior aaproval and may need CI�P. (Per Orono City Code,Chapter 78,Article IV) Job Site/Owner Information: Site Address: J���� ���j�'��� r� � �� Owner: Mailing Address: City: �`(Q�,� Zip: Home Phone: Alternate Phone: Contractor Information: Contractor: ►'Ve��,��,�,� /�������;�.�� Contact Person: �.�"��GC, ��E's" Address: I q�7� �'v�zCc� ��) State Bond#: !YI I� G .5 �,��� City: �c � -,r�, Zipt�-�jd�� Expiration Date: �]�� "" c�U� �' Phone: �S� 7�'� ���� Alternate Phone: �%S� / S) �� ��� ❑ Insurance—Current: v� , � �. �_. �w, �... 1 PLUMBING FIXTURES BEING INSTALLED FIXTURE BSMT l�T 2ND OTHER FIXTURE BSMT ]sT 2�u OTHER TYPE FL FL TYPE FL FL Water Closet � Floor Drains p� 7 Lavatory � Sewer Ejector Bathtub Laundry Tray Shower � Washer Kitchen Sink Water Heater � Disposal Water Softener Dishwasher Wet Bar Sillcocks � Miscellaneous I — t�c,� _'�-�,n.VC � Dr:r�k.� PERMIT FEE CALCULATION(S) BASED OFF - 2002 STATE STATUE ❑ Yes,this section applies The replacement of only one Residential fixture or appliance that meets all three of the following requirements: 1. Does not require modification to electrical or gas service. 2. Has a total cost of$500.00 or less;excludin�the cost of the fixture or appliance: and 3. Is improved, installed or replaced by the homeowner or licensed plumbing contractor. Skip next section, if this applies; Cost of Permit $ 15.00 State Surcharge $ 5.00 Mail-In Fee(If Applicable) $ 2.00 Total Permit Fee $ (Permit Fees Continued On Next Page) 2 t PERMIT FEE CALGULATI�N S -JOBS OVER'$540.00 If above does not apply; falluw guidelines belqw: 1. C:ON'C'KACT PRICE '� is 1.25°!A of cantract price with a{Minimum�`er of S30.OQ) /D`?(JOC.� X .a�zs� I ..3 � ti�� (contract pricc} (minimum SS0.00) 2. STAT�SURCHARGE 1n �� t�� � i v ����.-x .fl0U5 $ v � {ca tract pricc? 3. PUSTAGE&HANQL1hiG{Qnly on Mail-ln A�ptications) $ 2.00 4. "fUTAL PERMIT FEE(Add Lines 1-3 Abave} S t �_/ � L�� ■ �` CdNTRACT PFtICE or JOB COST means the actual or esti�nated dotlar amount charged for the permitied work including materiats,(abor,prafit,and vther fixed casts. !t is the amount to be charged to the custazner for the work done. lf any materiat,equipment, labor or installations are fumished by the owi�er, tenant or any ather party, the teasonable market value of such items rnust be added ta the estimated cost ar contract price far permit fee purposes. In the event that there is a dispute an the amount of the job cost, the City may request th� subm�ission af a signed copy of the actual cantract. -FLUMBING'�PERMI.T APPLICATION ACxREEMENT ` The undersigned hereby applies to the City far issuance of a Piumbing Permit, agrecs to do all work in strict accordanc;c with the orc3inances of thc Crcy and tl�e regulations of the State of' Minnesota, and certifies that alt statemes►ts rnade an this applicatian are complete, true and correct. , �'-��f- f� Applicant s S3gn�ture• Date: � � � . . 443 Lafayette Road N. � MINNESOTA DEPARTMENT QF (651)284-5005 St. Paul, Minnesota 55155 �BOR & i 1`I DUSTRY �"80 j DIAL-DLI www.dli.mn.gov TTY: 651 297-4198 � Division of Construction Codes and Licensing REPORT ON PLANS Plans and specifications on plumbing: Hennepin County Orono Maintenance Facility Expansion,3880 Shoreline Dr,Orono,Hennepin County,Minnesota,Plan No. PLB1412-00075 OWNERSHIP: Hennepin County C/O Greg Moore, 300 S 6th St., Suite A2208 Govt,Minneapolis,MN 55487 SUBMITTER(S): Paulson&Clark Engineering Inc.,2352 E County Road J,White Bear Lake,MN 55110 Plans Dated: Mechanical Plans—December 9,2014 Water Service Plan—December 2, 2014 Date Received: December 11,2014 Date Reviewed: December 19,2014 SCOPE: This review is limited to the design of this particular project only insofar as the provisions of the Minnesota Plumbing Code,as amended,apply,and does not cover the water supply or sewerage system to which this plumbing system is connected. The review is based upon the supposition that the data on which the design is based are correct,and that necessary legal authority has been obtained to construct the project. The responsibility for the design of structural features and the efficiency of equipment must be taken by the project designer. Approval is contingent upon satisfactory disposition of any requirements included in this report. Special care should be taken to insure that the material and installation of the plumbing system are in accordance with the provisions of the Minnesota Plumbing Code. A copy of the approved plans,specifications,and this Report on Plans must be retained at the project location for future reference. INSPECTIONS: All plumbing installations must be tested and inspected in accordance with the requirements of the Minnesota Plumbing Code. As specified in Minnesota Rules,part 4715.2830,no plumbing work may be covered prior to completing the required tests and inspections. Provisions must be made for applying an air test at the time of the roughing-in inspection as outlined in Minnesota Rules,part 4715.2820, subpart 2,of the code. A manometer test,as specified in Minnesota Rules,part 47152820,subpart 3, is required at the time of the finished plumbing inspection. It is the responsibility of the contractor/installer to notify the Minnesota Department of Labor and Industry when an installation for a state contract job,Minnesota Department of Health licensed healthcare facility,or project in an area where there is no local administrative authority is ready for an inspection and test. To schedule inspections,contact the state plumbing standards representative for your region. For your regional inspector's contact information, visit our website at http://www.dli.mn.gov/CCLD/CCLDContactus.asp REQUIREMENT(S): 1. Reduced pressure zone backflow preventers are permitted when periodic testing is done by a trained backflow preventer tester acceptable to the administrative authority. Testing intervals shall not exceed one year, and records must be kept. All devices must be tested after initial installation and overhauled at least once every five years. New installations must be at least 12 inches,but not more than 6 feet,above the finished floor or ground level. 2. Potable and nonpotable water distribution systems and outlets must be identified in accordance with Minnesota Rules,part 4715.1910. This information can be provided to you in alternative formats(Braille,large print or audio). An Equal Opportunity Employer � ' r ! Hennepin County Orono Maintenance Facility Expansion Plumbing Plan No.PLB1412-00075 Page 2 December 19,2014 3. The combination fire protection/domestic water service shall comply with the backflow protection requirements of AWWA-M14, Chapter 6 (1990)with the exception that the following statement is deleted from section 6.3: "At any time where the fire sprinkler piping is not an acceptable potable water system material,there shall be a backflow-prevention assembly isolating the fire sprinkler system from the potable water system." Fire sprinkler systems in which corrosion inhibitors or other chemicals may be introduced either directly or by pumper connections require a reduced pressure zone(RPZ)backflow preventer on the public water supply. Local jurisdictions may require additional backflow protection. Please contact the local water purveyor for information concerning their requirements. 4. Pressure vacuum breakers must be installed at least 12 inches above spill line and no possibility of back pressure permitted. If a hose will be installed,the backflow preventer must be installed above the highest point that the hose will located when in use. The minimum recommended height is 6 feet 6 inches. 5. The plans indicate that a faucet with a hand-held sprayer will be provided. If it is possible to submerge the sprayer and contaminate the potable water system,then an approved backflow preventer shall be provided on the water supply to the sprayer(see Minnesota Rules,part 4715.2100). 6. The flammable waste interceptor installation shall comply with Minnesota Rules,part 4715.1120: a. The interceptor shall be located so it is readily accessible for service and maintenance. b. The interceptor may be constructed either: (i)of monolithic poured reinforced concrete with a minimum floor and wall thickness of six inches,(ii)of iron or steel of a minimum thickness of 3/16 inch,protected with an approved corrosion resistant coating on both the inside and the outside,or(iii)of fiberglass resins that comply with ASTM C581 and meet IAPMO Material and Property Standard,PS 80-2003b, for clarifiers. 7. Showers and combination showers-baths shall be equipped with individual thermostatic,pressure balancing, or combination thermostatic and pressure-balancing control valves in accordance with ASSE 1016(see Minnesota Rules,part 4715.1380, subpart 5). The maximum temperature setting must be set or adjusted in accordance with the standard and should not exceed 110 degrees F. 8. Equipment used for heating water or storing hot water shall be protected by approved safety devices in accordance with Minnesota Rules,part 4715.2210 and part 4715.2230. 9. In no case shall water from roofs be allowed to flow upon the public sidewalk(see Minnesota Rules, part 4715.2700). Verify that the discharge from all rainwater leaders will meet this requirement. 10. Sheet M1.1 shows 8-inch storm drainage pipe serving approximately 11,700 square feet of roof area exiting the building. A 8-inch horizontal storm drain can only accommodate 11,500 square feet of roof area at a 1/8 inch per foot slope(see Minnesota Rules,part 4715.2710,subpart 4).Verify that the referenced 8-inch horizontal storm drainage pipe is sloped'/a inch per foot slope at a minimum or else the pipe shall be increased to 10 inches in diameter. 11. All portions of the storm sewer system located within 10 feet of the building or water service line must be tested in accordance with Minnesota Rules,part 4715.2820. A , Hennepin County Orono Maintenance Facility Expansion Plumbing Plan No. PLB 1412-00075 Page 3 December 19, 2014 12. Verify that the two-way cleanout referenced on Sheet M1.1 serving the flammable waste line is a single manufactured piece of equipment and not two separate cleanouts. No fitting,connection,or device which obstructs or retards the flow of water or sewage in an amount greater than the normal frictional resistance to show shall be used(see Minnesota Rules,part 4715.2420, subpart 3). 13. Each horizontal drain branch, including floor drain branches,shall be provided with a cleanout at its upper terminal with the following exceptions(see Minnesota Rules,part 4715.1000): a. A readily removable fixture trap or a fixture with an integral trap may be accepted as a cleanout. b. A floor drain cleanout may be omitted if the floor drain branch line is less than 5 feet. c. Shower drain,mop sink,and receptor cleanouts may be on the fixture vent,or on the fixture. 14. A cleanout shall be provided on a common vertical fixture drain or common vent serving two fixture traps that connect to a vertical drain at the same level. The cleanout shall be the same nominal pipe size as the drain serving the fixtures. Where the vertical fixture drain is accessible through the trap opening,the cleanout may be eliminated(see Minnesota Rules,part 4715.1000). I5. Above-grade horizontal plumbing piping must be supported as follows(see Minnesota Rules, part 4715.1430, subpart 4): a. Plastic pipe: at least every 32 inches. b. Cast iron: at least every 5 feet; or 10 feet when ten foot lengths of pipe are used. c. Copper tubing(P/a-inch or less): at least every 6 feet. d. Copper tubing(1'/z-inch or over): at least every 10 feet. 16. A full-way valve must be provided on the cold water supply line to the water heater(see Minnesota Rules, part 4715.1800). NOTE(S): 1. The scope of this project consists of the remodeling of an existing building. The plumbing installation shall include five roof drains and storm water drainage piping,water heaters,hose bibbs,pressure washers,a flammable waste interceptor,trench drains, floor drains,an emergency eyewash, an electric water cooler,a single compartment sink, two showers,and two public restrooms with flush valve water closets. 2. This facility will be served by an existing sanitary sewer and a new municipal water service. Authorization for construction in accordance with the approved plans may be withdrawn if construction is not undertaken within a period of two years. The fact that the plans have been approved does not necessarily mean that recommendations or requirements for change will not be made at some later time when changed conditions, additional information,or advanced knowledge make improvements necessary. -.. Hennepin County Orono Maintenance Facility Expansion Plumbing Plan No.PLB 1412-00075 Page 4 December 19, 2014 Approved: ----, . � ��_. r' Bob Johnson Public Health Engineer Plumbing Plan Review and Inspections Unit Phone: 651/284-5183 Email: Robert.L.Johnson@state.mn.us cc: Hennepin County C/O Greg Moore Paulson&Clark Engineering Inc. City of Oronoco Building Official Wsb&Associates Inc. File � DATE TIME ✓ ITY OF ORONO CALLED IN INSPECTION NOTICE /�,.�I,I�SCHEDULED �� � PERMIT NO.T��1�/5�(�[J'-YW�COMPLETED ADDRESS ��cS�S� �`��i'P ( i�Z� OWNER TELE HONE NO.I OSI'� l.Q�-�035Z CONTRACTOR �I���=�1��! ��" � DESCRIPTION ��uh'1��<'�'� � � ly ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL � Q ❑ POURED WALL �=R6UMBING RI ❑ EXCAV/GRADING/FILLING O ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ PROGRESS � ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP _ ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ HARD COVER REMOVAL J ❑ DEMO-SITE S TIC INSTALL ❑ FOUNDATION/REMOVAL � OWNERICONTRACTOR TO MEEf YO�YES_NO c�., COMMENTS: !,r G � ^ r � a �Jw V �r I'Ke'4S � W o w�,�.�f �G1G.�c�.� � 0 !'odN1 �l 4LE.' rJui �es� roo� d- WKc.I-r. ✓O!�- � � o �w � ��/C �� �j,v _ Q .5 � 4.� �e.SL is h�aP-;� .� � z � OK ZS Co�✓ W � j � 'T�44(ORKSATISFACTORY:PROCEED ❑ PROJECT COMPLEfE W �CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY 0 ❑CORRECT WORK,CAIL FOR REINSPECTION TEMPORARY V BEFORECWERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. � pH0T0 TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED ❑ INSPECTION REQUIRED_CALL TO ARRANGE ACCESS. Cail forthe next inspection 24 hours in advance. (g52) 249-46�� OwnerlContractor on site: �✓ Inspector_ I � White Copyllnspector's File Canary CopylSite Notice ::_. ��� ✓/ �.�7�"� DATE TIME� v CIn OF ORONO CALLED IN INSPECTION OTICE SCHEDULED ��� � PERMIT NO. �v�5 C%D�fPQ COMPLETED ADDRESS � S c��,> �Sj'1 L Y� %i��.E' �2� OWNER TELEP O��5�`�C� -�-�t� CONTRACTOR �I��/�/� /�'"�Q('�2� � DESCRIPTION �� ���"� � �'��-'��fr�u/2C� ty ❑ FOOTING D O-FINAL ❑ SEPTIC FINAL Q ❑ POURED WALL ❑ PLUMBING ❑ EXCAV/GRADING/FILLING y ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ PROGRESS � ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP _ ❑ AS BUILT-SURVEY ❑ S ER HOOK-UP ❑ HARD COVER REMOVAL J ❑ DEMO-SITE ❑�PTIC INSTALL ❑ FOUNDATION/REMOVAL � OWNERICONTRACTOR TO MEET YOU: YES_NO � COMMENTS: � � 5 ,ho� b�. �t-G. - � � v - �vG o � _ �,� _ � �. ° ^� � f�f �: ��� is �i�l� � -_ W 1 � ��MI'it�P LJei.f�C �4K�C /.S S�i '+ �/pC �or Z�s.cc�C Q � ��f � Z / � no v��.�c �� — W j �� � Go�� � d 4��MfOFiK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE 41,/�CORRECT WORK 8 PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY W O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ pHOTO TAKEN INSPECTOR WILL REfURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Ca11 for the next inspection 2a hours in advance. (952� 249-460� OwnerfContractor on site: Inspector. �/•,-.- White Copyllnspector's File Canary CopylSite Notice :�� DATE TIME CITY OF ORONO CALLED IN INSPECTION NOTICE SCHEDULED � � PERMIT NO. f(�( �-��nu .I/.'l`�� COMPLEf � ADDRESS �� ;���. r�� OWNER TELEPHONE NO. D���!' '�r '�G3S�, CONTRACTOR . ��,�,�Tr��r r� Or�L� � DESCRIPTION ,�L�<I'P ��G'Z`'Z�C�'1� f�'�d • W ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL�/;� Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADIN /FILLING O ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS � ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP _ ❑ AS BUILT-SURVEY ❑ S ER HOOK-UP ❑ FOUNDATION/REMOVAL J ❑ DEMO-SITE EPTIC INSTALL 2 OWNERlCONTRACTOR TO MEEi YOU• YES_NO c� COMMENTS: a� � r � 0 �. � � � � W � Q � W � W � j d W WOflKSATISFACTORY:PROCEED ❑ PROJECTCOMPLEfE � ❑ RRECT WORK 8 PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY 0 ❑CORRECT WORK,CALI FOR REINSPECTION TEMPORARY V BEFORECOVERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. p pHOTOTAKEN INSPECTOR WFLL RETURN ❑STOP OROER POSTED.CALL INSPECTOR �CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARHANGE ACCESS. Call for the next inspection 24 in a�2) 249-460� OwnerlContractor on site: Inspector: � White CopyAnspector's File Canary CopylSite Notiee �..J-.5 �:��. �. ---�:p� TIME CfTY OF ORONO CAL�ED IN �j a INSPECTION NOTICE /��i scHeou�E� �—�5--�5 .�s�7� PERMfT NO. %�✓� � `��` "r' COMPLEfED �j<� —�-- ADDRESS D�L/ _ ��j'`�}�'�(ti Li_. .�� �[:,'� OWNER � T EPH NE NO.f� l%'��" % � ' �,. CONTRACTOR ' '��^ �y t ' � �" � DESCRIPTION J�� . 4~j ❑ FOOTING ❑ DEMO F AL ❑ SEPTIC FINAL Q ❑ POURED WALL ❑ PLUMBI G RI ❑ EXCAV/GRADING/FILIING �O ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS � ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT � ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP W ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL _ J ❑ DEMO-SITE ❑ SEPTIC INSTALL ? OWNERICONTRACTOR TO MEET 1POU:_YES_NO � COMMENTS: � j 0 � � �O W � Q � W � W � j d W ❑WORKSATISFACTORY:PROCEED JECT COMPLETE � ❑CORRECT WORK 6 PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY W 0 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORECdVERiNG PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. p pH0T0 TAKEN INSPECTOR NfFLL RETURN ❑CITATION ISSUED ❑STOP ORDER POSTED.CALL INSPECTOR ❑INSPECTION REOUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hou 'n advance. 249-46�� OwnerlContractor on site: Inspector: White CopyAnspector's Fik Cenary CopylSfte Notice