HomeMy WebLinkAbout2006-fire/safety inspection •fi -
�.
... ._..... , . .- .. ... .
...... ... .. ..
OCCLlPANGY: DATE: KNOX: TYPE:
�'�/ l/�iC►- C.�-���- R E i N B� � � V 1C�
�!� n ����% � SPR SYS: ALARM: , J
�z//� �C.,� f /�� bb }.� �
ADORE55: �� ' / EMERGENCY �( �'%f� "vV .�C.l��
(�I/� �v�(/� CONTACT: � T
PHONE: 1 EMERGENCY � ��
��P� . �� �, g�O� PHONE�': ���,.-� . �j,.� . j
Inspeation of th4 occupa�cy listed above been DEEPHAVEN COMMENTS:
compieted in accorda�ce with the 2000 IFC and IXCELSIOR
the MSFC adopted by the city of:»»»» GREENWOOD
The following violations and/or deficienc' SHOREWOOD
uirin corrective actio�are noted bel .��C-'b'`}� TONKA BAY
EXTERIOR: # FIRE PROTECTION SYSTEMS: #
Address visible and I ible-Front and rear doors 1 S rinkler heads in ood condition- ro r covera e 1
Fire h drants accessible-36"minimum clearance 2 Door to s rinkler tem control room marked 2�
Fire lanes-Fire De rtment access 3 Riser 8 control valves accessible/current ins tion
FDC unobstructed 8 visibie- ro r ca -3' clear 4 Control vaives locked o n or tam er roteoted 24
Hom/strobe o erational-unobstructed�visibie Extin uishers ro rl located-current ins tion
Knox Box with ro rl labeled ke 6 ommercial hood s tems-clean &ins ected
Dum ters minimum 5' from buildin 7 Class K extin uisher resent in commercial kitchen 27
Gas meters 8� i in rotected 8 Fire alarm tem in ood condition-ins ected 2$
Buildin exterior maintained 9 Door to fire alarm room identified 29
IXITS: # INTERIOR/STORAGE: #
Exit doors unobstructed, o rable, ro er hardware 10 Stora e 18" or more below s rinkler heads 30
Exit corridors maintained and unobstructed 11 Stora e 24"or more below un rotected ceilin s 31
Exit si ns illuminated 12 No stora e in un rotected attics or below stairs 32
Pro er exit si ns dis la ed-6" minimum letters 1 No stora e in mechanical or electrical nel rooms 33
Emer en li htin in ood o eratin condition 1 o stora e in boiler or el�ator ui ment rooms 34
Occu n load osted (assembl ) Trash 8 oil ra s ro erl ke t or removed dail 35
ELECTRICAL EQUIPMENT: # Flammable and combustible li uids ro r stored 36
Door to electrical room/ nel labeled 16 Hazardous materials ro rl stored and identified 37
30" clear access to electrical anels 17 Com ressed as linders ro erl secured 38
Open s ces in electrical panels-knockout plugs 18 Ceiling tiles in lace 8�undamaged 39
Electrical hazards- er stri /circuit rotected 19 Wall or ceilin dama e re ired/seal netrations 40
No extension cords used as ermanent wirin 20 Smoke detectors o erational/ ro r location 41
Code Violation Summa :
l O��-T . G7 ✓�'�� O.� z��.�vi— �� /�Ul` �
,��.1� �Li ` ' L-�-�'�s
'� �� r G ,C-U� � � ���, f—i.�
-�
/ ' �" C�'��C�,�. .��-�1 �- �..`+G ,�c.� �
J � / / �-�
�' ' ' G �� _ !_�%��''� �%� � ` . � < < Lp !� /` a �' L.�
�-� �- - �v,� � � r� �. ,� � �`f"S �= i� S S�S ,
. �%`x�.i �-- • �c r C ti�,� .� ;� � �i�
� -,L�'S��-G-� � M �C T i�-� �7-"I:•1.-�� (J S � ,� ,,U ,'
�,�C�/1� � QD� � �' �O '�✓ The Fire District reserves the right to enforce the
r...,_� .�..y�-- MSFC If any other violations are diecovered during
�v���-'� � ✓ the compliance procasa or ae they may ariee.
� � Signature indicates receipt of copy
X � �'"., and cooperati with canpliance
Owner or Representative E�I�;or F; at�;ot I a orders within�days-
��.�—� �� � S � , ya- �--�