Laserfiche WebLink
� � <br /> COMMUNITY HEALTH DEPARTMENT <br /> ENVIRONMENTAL HEALTH MANAGEMENT GROUP <br /> HENNEPIN 1011 South First Street - Suite 215 <br /> Hopkins, Minnesota 55343-9413 <br /> Telephone: (612) 930-2770 FAX (612) 930-2782 <br /> August 19, 1994 <br /> Mary Jo Shirley, Director <br /> Shoreline Early Childhood Development Center <br /> 3?45 Sh�rel�n� Dr?�re <br /> Orono, Minnesota 55391 <br /> Dear Ms. Shirley: <br /> I have reviewed the plans for the addition of an infant room at the <br /> Shoreline Early Childhood Development Center. The plan is approved <br /> with the following conditions and requirements. <br /> 1. The floor covering in the feeding room and underneath the <br /> diaper changing area must be a smooth, easily cleanable <br /> surface. The linoleum proposed will be acceptable, however, <br /> when this floor covering begins to crack, chip, peel or in any <br /> other way becomes in disrepair, it must be replaced with <br /> approved floor covering such as quarry or ceramic tile. <br /> 2 . The wall covering behind the refrigerator and the length of <br /> that wall , and the wall covering behind the diapering station <br /> must be fiberglass reinforced paneling (FRP) or equivalent. <br /> This wall covering must be floor to ceiling in coverage. <br /> 3 . The counter top in the feeding room must be an approved food <br /> contact surface such as plastic laminate or stainless steel. <br /> 4 . The refrigerator must be NSF approved. Please send <br /> specifications to this office regarding this piece of <br /> equipment. <br /> 5. A minimum of one plumbed handsink is required in the infant <br /> room for food handlers and diaper changing. Two handsinks are <br /> recommended and preferred. One should be designated for the <br /> diaper changing area and one for the food preparation area. <br /> These handsinks also must be NSF approved. Soap, disposable <br /> towels, and a nailbrush are required at these handsinks. The <br /> pump handsinks are not acceptable. <br /> 6. A mechanical ventilation fan is required over the diaper <br /> changing area. <br /> HENNEPIN COUNTY <br /> an equal opportunity employer <br />