HomeMy WebLinkAbout2017-00936 - alarm system , CITY OF ORONO * 2 0 1 7 - 0 0 9 3 6 *
2750 KELLEY PARKWAY DATE ISSUED: 09/08/2017
� ORONO,MN 55356-
(952 249-4600 FAX: (952)249-4616
ADDRESS : 3542 SHORELINE DR
PIN : 17-117-23-43-0113
LEGAL DESC : NAVARRE HEIGHTS
: LOT 000 BLOCK 007
PERMIT TYPE : FIRE SYSTEMS
PROPERTY TYPE : COMMERCIAL-BUSINESS
CONSTRUCTION TYPE : ALARM SYSTEM
VALUATION : $ 5,582.00
NOTE: INSPECTIONS ARE DONE BY FIRE MARSHALL,JAMES VAN EYLL.
PLEASE CALL JAMES VAN EYLL DIRECTLY AT:(952)473-9701 TO SET UP AN INSPECTION.
COMMERCIAL FIRE ALARM-REPLACEMENT
ENTER CONTRACT PRICE 5582 ENTER THE VALUTATION 5582
APPLICANT FIRE ALARM 139.36
TYCO INTEGRATED STATE SURCHARGE VAL OTHER 2.79
2720 ARTHUR STREET ADVANCED PLAN REVIEW 90.58
ROSEVILLE,MN 55113- TOTAL 232.73
(651)587-4156 Payment(s)
Minnesota State License#:FIRE-TS0021 CHECK 3635981 232.73
OWNER
Shorelin�Navarre LLC
C/O LNR PROPERTIES
319 BARRY AVE S#301
WAYZATA,MN 55391-
AGREEMENT AND SWORN STATEMENT
The work for which this pertnit is issued shall be performed according to
the approved plans and specifications,applicable City approvals,and the
State Building Code. 1'his pertnit is for only the work described and dces
not grant permission for additional or related work which requires separate
permits. All provisions of laws and ordinances governing this type of work
shall be compied with whether or not specified herein.This permit will
expire and become null and void if construction authorized is not
commenced within 180 days of ihe date of issuance,or if construction is
' �pended for a period of 180 days at any time after work has commenced.
applicant is respons�bk for assuring all required inspect'ans are
ested in conformance wit6 the State Building Code.This permit may be
'ced at any time for due cause.
� /`L`i� / U /
'pP1r
�t Permitee Signature Date Issue By ' ahue Date
�
�
O/�T City of Orono R C USE ONLY
� ` VO P.O.Box 66 Date Received�� Permit# �` ��
2750 Kelley Parkway
Crystal Bay,MN �5323 Amount: $
�, �, (952)249-4600 roved B
y ,t App y: ❑Charge Plan Review
F �,�
�qKfSHU�'� Recommends: A roval Denial ❑
CITY OF ORONO—FIRE ALARM OR ,� ��,�J�
KITCHEN EXTINGUISHER/GENERAL PERMIT Q�
(All permits must be approved by the I�ire.�larsh,�ll and/or Building Official)
1. All fire alarm systems, voluntary or required by Minnesota State Building Code (MUBC) or
Minnesota State Fire Code(MUFC) shall be installed and maintained as per National Fire Protection
Association (NFPA) 72 and 72E, 1996 edition,National Electrical Code and manufacturers
requirements.
2. Permits are required for all fire alarm system installations. Permits can be obtained from the City of
Orono- Building Official at, 2750 Kelly Parkway Orono, MN or via phone(952)249-4600.
Permits are also available online at:www.ci.orono.mn.us
3. Two sets of plans and specification sheets shall be submitted to the Orono Fire Marshal for approval
at least 7 working davs before start of installation and shall include:
a. Specification data sheets on all components of system.
b. Floor plans indicating locations of devices, fire alarm control panel, sub-panels,transponders,
enunciator, interconnecting wiring and zoning.
c. Power connections including source and branch circuit data.
d. Type of back up power system.
e. Fire alarm control panel shall be compatible with all devices.
£ All components of the system shall be UL or FM listed for their applications. Smoke
detectors shall be listed for commerciaUindustrial use.
4. All systems shall be addressable. Smoke detectors shall be photo-electric. No combination
burglar/fire alarm systems are allowed unless approved by the Orono Fire Marshal.
�. Power supply for the system shall include battery back-up with a UL listed fire alarm panel. Alarm
verification is required for all systems using smoke detectors.
6. The alarm system shall be audible above the ambient noise level in all areas of the building.
Audio/visual signaling devices are required.
7. When central station notification is required or provided it must be through a UL or FM listed
communicator or control panel.
8. If a smoke detecting system installed in the tenant space of a building is directly connected to the
building fire alarm panel, then
a. A zone on the alarm panel must identify the tenant space or zone of the building that the
system is located(i.e., second floor, west wing).
b. A visual annunciation light shall be installed on the corridor side of the main door of the
tenants space and activate when the detection system in the tenants space activates.
9. The system shall be tested in the presence of the Orono Fire Marshal for final approval.
Appointments can be made by calling the Fire Marshall at(952) 473-9701,
24-hours notice is requested. The test will include:
a. Random testing of system devices. R��+��V��
b. Random testing for system trouble and ground fault trouble. ��� � � ZQ,7
c. Correct operation of back-up power system.
CITY OF ORONO
i
l
FIRE ALARM OR KITCHEN EXTINQUISHER P TS
� ' In�� � 1� _ ' i��j
��
��`UV� 1 '� l�'
Please Check One: � ���
W G�
'� New ❑ Addition ❑ Remodel 0 Replace � �
Job Site/Owner Information:
Site Address: 3542 SHORELINE DR
CARQUEST
Owner: Mailing Address: 3542 SHORELINE DR
City: NAVARRE Z�p: 55392
Home Phone: 952-471-0156 Alternate Phone:
Contractor/Applicant Information:
Contractor/App.: TYCO INTEGRATED SEC Contact Person: _jF'FF FRRNC'H
Address: 2720 ARTHUR ST State License #: TS0021
City: ROSEVILLE Zip: 55ll3 Expiration Date: MAY 2018
Phone: F51-5R7-41 5� Alternate Phone:
TYPES OF FIRE PERMITS
�J ����� � ��
� Commercial —Fire Alarm Com�—Fire Extin u�sher
Fire Systems Pennit Fire S}'stcros Pem�it
*(�er UBC) *(�er UBC)
*Contract Price: $ 5582 *Contract Price: $
❑ Residential—Fire Alarm
Fire Systems Yennit
* (Per UBC)
" Contract Price: $
*Note: Permits are calculated with UBC Fee Schedule;submit application and we will�,��J���.�e for the
pennit.
I herby apply for a Fire Alarm/Extinguisher Permit and I acknowledge that the information above is complete
and accurate; that the work will be in conformance with the Ordinances and Codes required by Minnesota
State Building Code(MUBC)or Minnesota State Fire Code(MUFC)shall be installed and maintained as per
National Fire Protection Association (NFPA) 72 and 72E, 1996 edition, National Electrical Code and
manufacturers requirements; that I understand this is not a permit and work is not to start without a permit;
and that the wark will be in accordance with the approved plan.
Applicant Date
i
QFNEAAL INFORMAT�ON �.��.'.
'� �w.e>.E,.�w a s�o tYd ��Y 4�-P aw�atn No�:ff'
,� •�nw`.�"�+v�`� � . . ���� � � e�W cl[I6�tt5 M 5f
t �s� n�� �(�y�tK /�t� Y `
w ..,�,�,.z _e, �
..�. ..�..-,•�.. wNt::�a
�i n..°so�uwe ��FF�'�FB�id Ykltl 4�o64G' �_'�`�y�M j
Y Mb 9v W i ����
f 2Y SYcz�lv Gs sw a� �� ����i�'.��
:����:��t:�,� .,��ce City of�rono ' � � / 1 � �ro�P����
�.,�..�. //����1////���' �
tri W atw Iv lmlO M[kl F ~ �� 1/ 1� 1
� aYfU�IGN N�1E5:ffE PLW lq16�
,�. ias w ra.�...a�vw srm. � t v , N�ES
:����, � ��- � \ �ro�v,rnmEs:esou rwa na
.....a va w....v. . ;" '��Ol�f«T°��!l5 5�t 1�6WL� ���
w.�.e.,r r..i.nwn.-.s .
, " F71�R4 91U1Y1G M k\4iY SECIION OF PJ(IFIS �.
�'»'."`_'n°'q�i�i� 4 s W � Pb[Wro CO�npM'1/an ��,.
�
��� � SECOND LEVEL MEZZ ,����,� "'� � ,
�a so n sn s�� :
sw[srtoa+m R �n i�t
vu�rs pCPf Sq rt 1171 YAZ
r�Y-Y
� �-S f�' S�l �'-Y � ��
WIB 4�
b ��S ��y� I�
�` «Yr`
i S� 5y # i� . I ! �y/� ��[/����yt�
� .� � i� F .�`i . I '_ _`_s�Js -�....___��'�������.������_�eve�ee�i�`���`����i �M'r^ YlNu
_---�......��..vee>e..>...xna�..e _ __________ • ,
��'� 4 i $� '. �isR � � u ,I IHl %$
C � �
I !-! SX fX `� �� �!{ !; °� �� � �
� rr rc � '� , ws�s��an xmrtrn t/dl�' r%M'M
b
��, �-r i.�� � .. "�!� „ � �.� ':., w 9a5 Ra i 5tc� 7e Ti
�� � � i t ��� ra 9ul Wn7Y � ��+Ti
' � �k� r\t=�. wK9�f60�C9a&MW
� r.� rn p��r FA�P .� ,, � � K.� w iman iKm sns:�wm
� � �; D� r-r � wr+�vx sw cvxm uaua�ctaa ra
F;� w s � �� , !�aa x�z,��na wR[.tx
� � `-- b-- �,r =__ _== "= === =__ __= _ _,__ F�AA �CJ ist:a[w aau Ft�w w su vnoM
� rt �� �� �Z
. � f�! ta' 161[tt+WGWC10k b ���n � C i—/�� KEY:
3 IYl ��u ti �l.�y L � �� ��.tl�l L�!
-� � ,:�,¢ M d..s.dp6p[i D S 4I VCW 6F�I Sqi[6�
n er w
'., '' ' i `� i `' I Q °'—°Oi061d6 A�E01K a RMK GFAYIR
'',... 3 ; �•:r'}' � �"4' �d � �J avn,wv�� o�n uvwavo�
; r-r rr " mt�6 ti i--=-----_'i__-__----� __-=__-_====�UfV1�ll��� _.:�_ _ v�tuEecx. w�M �
..... _ „ " � , '_.�__ '-r-------- � _ _ _ ' - OPEPhfWHS �!h MI[
��... i t$ � S�' tY-f HY.IAi1R. WfUD/h W1[ .
4
RM9pNi
,, � f-1' Y-0' F ti �� F �I.
i
� '.. � �{ MMf UIlIf Nd U�ME Md pIR Md s{ �,..
n
i i� �
,,. N ti II ti * ,�.
!f Yd y Q�A1CH ��
�� .; Y-f 5-! .
§ F ntiT � �_==__=x=�x=�o-Y� ___z_==t�s==_�Y=t_Y_rr�_ _ �SS
: /�� ���'�"` �$ • KB naa a ua:m/nln �os/u/u
\'.';"" � � �� � Q� YYr AYiY rr M4 ❑
� ' _ �-/i fu-w l.�I lY.T ��w:��-��
"� OUTSIDE PIV AND KNOX E GATE AND FLOW �t�°.�2 +n� w�c.M
NOIE TO Ff17111�5:f5TAL1 M�OI 1Nf.ItlIE NI � 1FiW All&)l7(IiiWTD!�{RD 0!I 1NC 84�E 9F NP Fl7�lUR[S. n o a1��
WTD!
i NOT MONITORED � o ° ��
_ _ _ - - ,� .
- �
GO
/ntegrated Security
Fire Alarm Submittal
Preparedfor
Advance Auto Parts
3542 Shoreline Drive
Navarre, MN 55392
Submitted By:
Tyco Integrated Security
2720 Arthur Street
Roseville,MN 55113
651-846-8010
Jerry Polomny
j a polom ny(o�tYco.co
Designed By:
Tyco Integrated Security
National Accounts Sales&Support
1800 International Park Dr STE 500
Birmingham,AL 35211
Joel Remson
Phone: (205)943-6538
Fax: (205)942-4943
N[CET lll#130880.
Install Location
Customer Name Advance Auto Parts
Store Number 3962
Address 3542 Shoreline Drive
Cit Navarre
State MN
Zip Code 55392
Contact
Phone
Branch 5$
Monitorin Center 5004
NAM,#
NAM
NAM Address
NAM Cit
NAM State
NAM Zip
NAM Phone
NAM Fax
NAM Email
Fire Planner Joel Remson
FP Address 1800 International Park Dr STE 500
FP City Birmingham
FP State AL
FP Zi 35211
FP Phone (205)943-6538
FP Fax (205)942-4943
FP Nicet Number 130880
System Outline
I. Location
Advance Auto Parts 3962
3542 Shoreline Drive
Navarre,MN 55392
IL Codes
A. 2015 NFPA 72 Chapters 1-27 as Applicable(Remote Station)
B. 2015 Minnesota Electrical Code Articles 250,725,760
C. 2015 Minnesota Fire and Building Code
D. All Current editions of Local,City and State adopted codes
III. Control
A. 1 MS-9050UD Addressable Fire Alarm Control Panel
B.
IV. Dialer/Communicator
A. 1 IPGSM-4G IP Internet&GSM 4G Dual Path Conmmunicator
V. Fire Alarm Initiating Devices
A. 1 SD355 Smoke Detector Photo
B. 1 BG-12LX Manual Pull Station Addressable
C. 1 Water flow Connection Only, Provided by Others
D.
E.
F.
F.
G.
VI. Fire Alarm Indicating Devices
A. 1 P2R-110 Wall Horn strobe RED 24VDC 110CD
B.
C.
D.
E.
F.
VII. Zones
All devices are addressable with there own address
1-50 Detector/Module addresses
SLC Loop is style 4 Class B
VIII. Wiring
All Circuits and Wiring Shall be"Power Limited"
SLC Circuits Shall be 16/2 Shielded U.L.FPLP Cable
Indicating Circuits Shall be 14/2 U.L. FPLP Cable
System Ground Shall be 14 THWN Green Conductor
Under Ground and Outside Wire shall be 14 THWN in Approved Raceway
IX. Listings
A. All Equipment Shall Be U.L. Listed and Compatible
X. Power Supply
A. Primary-110 VAC Dedicated 20 Amp Circuit
B. Secondary-10 Amp Hour
X. Alarm Supervision
A. Human
B. Remote Station Installing Branch/Contractor
TYCO Integrated Security Tyco Integrated Security
14200 E Exposition Blvd. 2720 Arthur Street
Aurora,CO 80012 Roseville, MN 35113
(303)338-8200 651-846-8010
S994-183 UUFX
Standby Battery Calculations
MS-9050UD
Advance Auto Parts
Navarre, MN 55392
Standby Current Alarm Current
Part Number Descri tion Quanti Per Device All Devices Per Device All Devices
MS-9050UD Addressable Fire Alarm Control Panel 1 0.120000 0.120000 0.020000 0.020000
SD355 Smoke Detector Photo 1 0.120000 0.120000 0.020000 0.020000
BG-12LX Manual Pull Station Addressable 1 0.000300 0.000300 0.000300 0.000300
MMF-300 Monitor Module Single input 3 0.000400 0.001200 0.005100 0.015300
._._.�__._..................... ...........................................
Total Aux current Max 3 Amps 0.242 Alarm 0.056
Si nal Circuits
Current Current
Circuit Device Quanti Per Device All Devices
Circuit 1
P2R-110 1 0.212 0.212
....................................................._,,...,,,,......,,.,,....,...
Total 1 Maximum 2.5 Amps 0.212
Circuit 2 Not Used
.................................................................�...,..._....._
Total 2 Maximum 2.5 Amps 0.000
Totals Maximum 2.7 Am s 0.212
Circuit 1 Circuit 2
Max Wire Run Distance For AWG 14 3073
Actual Wire run Distance 50 0
Voltage Drop for 14 AWG wire 0.065
Volta e Dro =2'Wire Run Distance`3.07 Ohms Per 1000 ft 14 AWG'Total Current for Circuit/1000
Standby Hours 24
Standby Battery Draw 0.242
Standb Amp Hrs 5.796
Alarm Current 0.212
Alarm Current 5 Min 0.018
Battery Size Required
with 5 Min.Alarm Time
and 20%Reserve 6.976
Batte Size Supplied 10 A.H
FACP
Voltage Drop Calculations
Point to Poin[Method End of Line Method Load Centerin Me[hod
Prolect Name Advance Auto Parts-Navarre MN CIRCUI7IS W ITHIN LIMITS CIRCUIT IS W ITHIN LIMITS CIRCUI7IS WI7HIN LIMI7S
Date 5/Jul/17
CircudNumber NAC-1 Totals Vottage Totals Vottage Totals Voltape
Power Source 120 VAC Current Distance Orop Current Distance Drop Curtent Distance Drop
Nominal System Vottage 20.4 0212 50 0.07 0212 50 0.065 0.212 50 0.03J
Minimum Device Voltage i6 End of Line Volta e 20.33 End of Line Volta e 20.33 Entl of Line Volta e 20.37
Total Circuit Curren� 0212 Wire Ohm's Percent Dro o.3z% Percent Dro o.3z% Percent Dm o.16%
Gau e Per 7000 End of Line and Load Centering Methods use only ihe wire guage forthe frst tlevice to source
50 14 3.07 Standard Wire Resistance in Ohms per 1000 teet.
Wire Gau e for balance of circuit 14 3.07 18=777 16=4.89 14=3.07 12=1.98 10=L24
Enter curteM in amps. Distance 18-14 Aw =Solid Conductors 12-10 Aw =Stranded Conductors
.150=150 ma (rom Vottage Notes:
Device Device previous At Drop fmn Percent Wire resistance is doubled in the calculations for hvo wires(Positive and Negative)
Number Current 35 Device source Dro The voltage calculatetl to the last tlevice in any method must not be lower then
Device 1 P2R-110 0212 50 20.33 0.065 oazzu the manufactures listed minimum operating voNage QE rated operating voltage 2032 VDC).
END 20.33 0.065 0.32°b
END 20.33 0.0fi5 oaz°t, Device Manu(acturer System Sensor
END 20.33 0.065 0.32%
END 20.33 0.065 o�ru Hom/Strobe Devices Sirobe Onl Devices
END 20.33 0.065 o.a2w Wall Current Wall Ceiling Current UL
END 20.33 0.065 0.32% Mount Ceiling Mount Cantlela UL Max Mount Mount Candela Max
END 20.33 O.OfiS o.32% P2RM/ PC2R/W 15 0.079 SRNV SCR/W 15 0.066
END 20.33 O.OfiS o.3zss P2RM/ PC2R/W 30 0.107 SRM/ SCRNV 30 0.094
END 20.33 0.065 0.32% P2RNJ PC2R/W 75 0.176 SRM/ SCR/W 75 0.158
END 20.33 0.065 o.3zss P2RNV PC2R/W 95 0.194 SRM/ SCWW 95 0.181
END 20.33 0.065 0.32% P2RNJ PC2R/W 170 0212 SRNJ SCR/W 110 0202
END 2033 O.OfiS o.3rw P2RNJ PC2R/W 115 0218 SRNV SCR/W 115 0210
END 20.33 0.065 0.32% P2RH/N/H PC2RH/WH 135 0245 SRH/VJH SCRHM/H 135 0228
END 20.33 O.OfiS o.rns P2RH/WH PC2RH/WH 150 0259 SRH/WH SCRH/WH 150 0246
END 20.33 0.065 0.32% P2RH/WH PC2RH/WH 777 0290 SRH/VJH SCRH/VJH V7 0281
END 20.33 0.065 o.rrw P2RH/WH PC2RH/WH 165 0297 SRH/WH SCRH�'WH 185 0286
END 20.33 0.065 0.32% m icates re evice. in icates re evme.
END 20.33 O.OfiS o.rzx "W"indicates whde device. "W"Indlcates white device.
EN� 20.33 0.065 0.32% "H"indicates high candela device "H"indicates high candela device
Totals 0212 50 End o(Line Vofla e 20.33
� � Point to Point Method End of Line Method Load Centerin Method
Prolect Name � Advance Auto Parts-Navarre MN CIRCUIT IS W ITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS W ITHIN LIMITS
Date 5/JuV17
Circuit Number NAC-2 Totals Vottage Totals Vottage Totals Voltage
Power Source 120 VAC Current Dislance Drop Current Distance Drop Current Distance Drop
Nominal System Vottage 20.4 0.000 0 0.00 0.000 0 0.000 0.000 0 0.000
Minimum�evice Voltage 16 End of Line Vofta e 20,40 Entl of Line Volta e 20.40 Entl of Line Volta e 20.40
Total Circuit Current 0.000 Wire Ohm's Percent Dro o.msc Percent Dro oo055 Percent Dro oao°c
Gau e Per 1000 End of Line and Load Centering Methods use only the wire guage for[he first device to source
Distance from source to tst device 0 14 3.07 Slantlartl Wire Resistance in Ohms per 1000 feet.
Wire Gau e for balance of circuit 14 3.07 18=777 16=4.89 14=3.07 12=1.98 10=L24
Enter curtent in amps. Distance 18-14 Aw =Solid Conductors 12-10 Aw =Stranded Conduclors
.150=150 ma from Vottage Notes:
Device Device previous At �rop fron Percent Wire resistance is doubled in the calculations forhvo wires(Posi[ive and Negative)
Number Curtent device Device source Dro The vottage calculated to the last tlevice in any methotl must not be lower then
Device 1 20.40 0.000 o.m55 ihe manu(actures listed minimum operating vottage QE:rated opereting voltage 20-32 VDC).
END 20.40 0.000 0.00%
END 20.40 0.000 o.m°6 Device Manufaclurer System Sensor
END 20.40 0.000 o.arx
END 20.40 0.000 o.00s6 Hom/Strobe Devices Strobe Onl Devices
END 20.40 0.000 o.arw Wall Curtent Wall Ceiling CurrentUL
END 20.40 0.0�0 0.00% Mount Ceiling Mount Candela UL Max Mount Mount Cantlela Max
END 20.40 0.000 o.00ss P2RNV PC2R/W 15 0.079 SRM/ SCR/W 15 0.066
END 20.40 0.000 o.00°b P2R/W PC2R/W 30 0_107 SR/W SCR/W 30 0.094
END 20.40 0.000 o.00ss P2RNJ PC2R/W 75 0.176 SRM/ SCR/W 75 0.158
END 20.40 0.000 0.00% P2RM/ PC2RlVJ 95 0.194 SR/W SCR/W 95 0.181
END 20.40 0.000 o.W% P2RNV PC2R/W 110 0212 SRNJ SCR/W 110 0202
END 20.40 0.000 o.mv, P2RNV PC2R/W 115 0.218 SR/W SCR/W 115 0210
END 20.40 0.000 o.00°a P2RH/VJH PC2RH/WH 135 0245 SRH/WH SCRHM/H 135 0228
END 20.40 0.000 o.00v, P2RH/WH PC2RH/WH 150 0.259 SRH/WH SCRHM/H 150 0246
END 20.40 0.000 0.00% P2RH/WH PC2RH/VJH 177 0290 SRH/WH SCRHNJH 177 0281
END 20.40 0.000 o.009c P2RH/WH PC2RH/WH 785 0.297 SRH/WH SCRHMJH 185 0.286
END 20.40 0.000 0.0096 'indicales re evice. 'm Icates re evice.
END 20.40 0.000 o.00ss "W"intlicates whde device. "W"indlcates white device.
END 20.40 0.000 o.W% "H"indicates high candela device "H"intlicates high candela device
Totals 0.000 0 End of Line Volta e 20.40
Standby Battery Calculations
IPGSM-4G
Advance Auto Parts
Navarre, MN 55392
Standby Current Alarm Current
Part Number Description Quanti Per Device AII Devices Per Device All Devices
IPGSM-4G IP Internet&GSM 4G Dual Path Conn 1 0.230 0.230 0.950 0.950
Auxilia devices Maximum 3 Am s
o.000 o.000
o.000 o.000
Total Aux current Max 3 Amps 0.230 Alarm 0.950
Calculations are based on a minimum supply voltage of 20.4 Volts Standby Hours 24
and a minimum voltage at the end of line of 16 Volts. Standby Battery Draw 0.230
Calculations assume that all devices are at the end of the line. Standb Amp Hrs 5.520
Alarm Current 0.950
Alarm Current 5 Min 0.080
Battery Size Required
with 5 Min.Alarm Time
and 20%Reserve 6.720
Batte Size Su lied 7 A.H.
DF-52418:E1 •A1-20
MS-9050UD(E) � Flf'�•�i-reA�arms
Fire Alarm Control Panel
with DACT by Honeywell
General ............,,...�,.,...._....
The Fire•Lite MS-9050UD(E) is a Fire Alarm Control Panel
(FACP) and Digital Alarm CommunicatorlTransmitter (DACT)
combined into one circuit board. This compact, intelligent
addressable control panel supports up to 50 addressable �,: �
devices of any type of detectors and modules. With an exten-
sive list of powerful features,the MS-9050UD programs just like
Fire•Lite's larger products, yet fits into applications previously
served only by conventional panels. ���
The MS-9050UD's integral DACT transmits system status b
(alarms,troubles,AC loss,etc.)to a Central Station via the pub- 3.
lic switched telephone network. It also allows remote and local `�'�
programming of the control panel using the PK-CD Upload/
Download utility. In addition, the control panel may be pro-
grammed or interrogated off-site via the public switched tele-
phone network. Any personal computer with WindowsT" 95 or
greater, and compatible modem with a speed of 14.4 kbps or
faster and Fire•Lite Upload/Download software kit PK-CD, may � _ _ v�
serve as a Service Terminal.This allows download of the entire
program or upload of the entire program, history file, walk-test
data,current status and system voltages. • Point trouble identification.
The power supply and all electronics are contained on a single • Waterflow selection per module point.
circuit board supported on a new quick install chassis and • Alarm verification selection per detector point.
housed in a metal cabinet. Available accessories include local . Maintenance alert warns when smoke detector dust accumu-
and remote upload/download software, remote annunciators, lation is excessive.
and reverse polarity/city box transmitter.(4XTMF) . One-person audible or silent walk test with walk-test log and
New options include a UL listed printer, PRN-6F and the new printout.
IPDACT Internet Monitoring module.The FireWatch Series inter- . System alarm verification selection per detector point.
net monitqring modules IPDACT-2 and IPDACT-2UD permit
monitoring of alarm signals over the Internet,saving the monthly ' PAS (Positive Alarm Sequence) and Pre-signal per point
cost of two telephone lines. Although not required, the second- (NFPA 72 compliant).
ary telephone line may be retained providing backup communi- • Up to eight ANN-BUS annunciators
cation over the public switched telephone line. • Remote Acknowledge, Alarm Silence, Reset and Drill via
NOTE: Unless otherwise specified, the term MS-9050UD is used addressable modules or remote annunciator.
in this data sheet to refer to both the MS-9050UD and the MS- • Upload/Download (local or remote) of program and data via
9050UDE FACPs. For MS-9050UDC,refer to DF-60445. integral DACT.
Features SLC COMMUNICATION LOOP
• Single addressable SLC loop which meets NFPA Style 4, 6
• Listed to UL Standard 864,9th edition. and 7 requirements.
• Auto-program (learn mode) reduces installation time. . 50 addressable device capacity(any combination of address-
Reports two devices set to the same address. able detectors and modules).
• On-board DACT. • Compatible with Fire•Lite's addressable devices(refer to SLC
• Two independently programmable Style Z(Class A) or Style Wiring Manua�.
Y(Class B)NAC circuits.
• Selectable strobe synchronization for System Sensor,Whee- NOTIFICATION APPLIANCE CIRCUITS(NACS)
lock,and Gentex devices. • Two independently programmable output circuits. Circuits
• Remote Acknowledge, Silence, Reset and Drill via address- can be configured for the following outputs:
able monitor modules. –Style Y(Class 8)
• Two programmable relays and one fixed trouble relay. –Style Z(Class A)
• Built-in Programmer. –Door Holder Service(cannot be used for notification appliances)
• Telephone Line Active LEDs. –Aux Power Source(cannot be used tor nocification appiiances)
• EIA-232 PC interface. • Silence Inhibit and Autosilence timer options.
• Integral SO-character LCD display with backlighting. • Continuous, March Time, Temporal or California code for
• Real-time clock/calendar with automatic daylight savings main circuit board NACs with two-stage capability.
control. • Selectable strobe synchronization per NAC.
• History file with 500 event capacity. • 2.5 A total power for NACs.
• Automatic detector sensitivity testing(NFPA 72 compliant). NOTE: Maximum or total 24VDC system power shared between
• Automatic device type-code verification. all NAC circuits and the ANN-BUS is 2.7A.
DF-52418:E1•1/27/12—Page 1 of 4
PROGRAMM/NG AND SOFTWARE
• Autoprogram(learn mode)reduces installation time.
• Custom English labels (per point) may be manually entered
or selected from an internal library file.
, • Two programmable Form-C relay outputs.
�$�..�' • 20 software zones.
'" • Continuous fire protection during online programming at the
front panel.
�^.�S y�s;�u�.: � • Program Check automatically catches common errors not
FireAlarm �, linked to any zone or input point.
Controi Panel �y``
• OFFLINE PROGRAMMING: Create the entire program in
g FlNN ao your office using a Windows0-based software package(order
� programming kit PK-CD, containing PS-Tools, separately).
N Upload/download system programming locally.
�, _
SD355 �r��,cPr User interface
Photo Detector Gateway LED/NDICATORS
ANN-S/PG
• AC Power(green)
� _ . � • Fire Alarm(red)
�;.,--.
• Supervisory(yellow)
AD355 Graphic LED Module • Trouble(yellow)
Adapt Detectw ANN-i/0
• Alarm Silenced signals(yellow)
t KEYPAD
�'� :�� • 16 key alpha-numeric pad
� .
H355M355R/H355HT Relay Module Acknowledge/Step
Heat Detecta ANN-RLY P2R • Alarm Silenced
Strobe • Drill(Manual Evacuate)
• Reset(lamp test)
MDF-300 � Product Line Information
Dual Monitor Module
P2R MS-9050UD(E): Combination DACT/Fire Alarm Control Panel
Strobe with one SLC�loop. Includes main circuit board with display,
�� Power Suppry chassis with transformer,backbox with door,plastic bag contain-
� . ,� . FCPS-24FSfi � ing screws, cables, key, etc., manuaL (For MS-9050UDC, refer
"' FCPS-24FS8 to DF-60445.)
SD355T �
Phato/Thermal PK-CD: Contains PS-Tools programming software for Win-
� Strabe dowsabased PC computer(cable not included).
r .� DP-51050:Optional dress panel for the MS-9050UD.
�_. ':
Multi-Modules TR-CE:Optional trim ring for semi-flush mounting.
MMF-300 . �RF-300-6 Six-Relay Control Module BB-2F:Optional cabinet for one or two modules.
Monitor Module . �F-300-6 Six-Circuit Su ervised ConVol Module
P BB-6F: Optional cabinet for up to six modules mounted on
• MMF-302-6 Six-Zone InteAace Module CHS-6 chassis.
_ • MMF-300-10 Ten-Input Monitor Module gg_26: Battery backbox, holds up to two 25 AH batteries and
' CHG-75.
MMF-302 BB-55F: Battery box, houses two 55 AH batteries
2-Wire Detector
MonitorModule � CHS-6: Chassis, mounts up to six multi-modules in a BB-6F
, cabinet.
CHG-75: Battery charger for lead-acid batteries with a rating of
+�� 25 to 75 AH.
D355PL eeam Detector CHG-120F: Remote battery charging system for lead-acid bat-
Duct Detector 8�-335/(S) teries with a rating of 55 to 120 AH. Requires additional BB-55F
for mounting.
MS-9050UD BAT Series: Batteries,see data sheet DF-52397.
� PRT/PK-CABLE: Cable printer/personal computer interface
�, ADDRESSABLE FIRE ALARM pRN 6F: UL listed compatible event printer. Uses tractor-fed
eG-�z�zaddressable C�NTR�� PANE� paper.
Manual Pull Station
IPDACT, IPDACT-2/2UD Internet Monitoring Module: Mounts
in bottom of enclosure with optional mounting kit(PN IPBRKT).
Connects to primary and secondary DACT telephone output
ports for internet communications over customer provided ether-
Page 2 of 4—DF-52418:E1•1/27/12
net internet connection. Requires compatible Teldat Visoralarm 4.0"(10.16 cm.)box.Includes plastic cover plate and end-of-line
Central Station Receiver.Can use DHCP or static IP. (See data resistor.Module may be configured for either a Style B(Class B)
sheet df-52424 for more information.) or Style D(Class A)IDC.
IPBRKT:Mounting kit for IPDACT-2/2UD in common enclosure. MDF-300: Dual Monitor Module. Same as MMF-300 except it
IPSPLT:Y-adaptor option allows connection of both panel dialer provides two Sryle B(Class B)only IDCs.
outputs to one IPDACT-2/2UD cable input. MMF-301: Miniature version of MMF-300. Excludes LED and
AC-TRMBLK:AC Terminal Block mounts to a metal bracket, in Style D option.Connects with wire pigtails.May mount in device
turn, mounts to the FACP chassis.Use AC-TRMBLK when wire backbox.
nuts are not allowed for AC connections to the transformer. MMF-302A:Similar to MMF-300A.Addressable Monitor Module
for one zone of conventional two-wire detectors. Requires reset-
OPTIONAL MODULES table 24 VDC power. Refer to the Device Compatibiliry Docu-
4XTMF Reverse Polarity Transmitter Module: Provides a mentfor listed compatible devices and quantity limitation.
supervised output for local energy municipal box transmitter, CMF-300:Addressable Control Module for one Style Y/Z(Class
alarm and trouble. Includes a disable switch and disable trouble g/A) zone of supervised polarized Notification Appliances.
LED. Mounts directly to a 4.0" (10.16 cm.)electrical box. Notification
ANN-SEC: Optional secondary ANN-BUS interface module. Appliance Circuit option requires external 24 VDC to power noti-
Note:Used only with firmware 3.0 or higher. fication appliances.
COMPATIBLEANNUNCIATORS CRF-300: Addressable relay module containing two isolated
sets of Form-C contacts, which operate as a DPDT switch.
ANN-80(-W): Remote LCD annunciator mimics the information Mounts directly to a 4.0" (10.16 cm.) box, surface mount using
displayed on the FACP LCD display.Recommended wire type is the SM8500.
un-shielded.(Basic model is red;order-W version for white;see gG-12LX: Addressable manual pull station with interface mod-
DF-52417.) ule mounted inside.
ANN-I/O: LED Driver Module provides connections to a user �300:This module isolates the SLC loop from short circuit condi-
supplied graphic annunciator.(See DF-52430.) tions(required for Sryle 6 or 7 operation).
ANN-LED: Annunciator Module provides three LEDs for each SMB500: Used to mount all modules except the MMF-301 and
zone: Alarm, Trouble, and Supervisory. Ships with red enclo- M301.
sure. (See DF-60241.)
ANN-RLED: Provides alarm (red) indicators for up to 30 input MMF-300-10:Ten-input monitor module.Mount one or two mod-
zones or addressable points. (See DF-60241.) ules in a BB-2F cabinet(optional).Mount up to six modules on a
CHS-6 chassis in a BB-6F cabinet.
ANN-RLY: Relay Module provides 10 programmable Form-C MMF-302-6: Six-zone interface module.Mount one or two mod-
relays. Can be mounted inside the cabinet.(See DF-52431.) ules in a BB-2F cabinet(optional).Mount up to six modules on a
� ANN-S/PG: Serial/Parallel Printer Gateway module provides a CHS-6 chassis in a BB-6F cabinet.
connection for a serial or parallel printer. (See DF-52429.) CMF�00-6:Six-circuit supervised control module.Mount one or
� � ADDRESSABLE DEVICES two mpdules in a BB-2F cabinet(optional).Mount up to six mod-
� All feature a polling LED and rotary switches for addressing. ules on'a CHS-6 chassis in a BB-6F cabinet. �
CP355:Addressable low-profile ionization smoke detector. CRF-300-6: Six-reiay control module (Form-C relays). Mount
one or two modules in a BB-2F cabinet(optional).Mount up to
SD355:Addressable low-profile photoelectric smoke detector. six modules on a CHS-6 chassis in a BB-6F cabinet.
SD355T: Addressable low-profile photoelectric smoke detector NOTE:For more information on Compatib/e Addressab/e Devices
with thermal sensor. for use with the MS-9050UD,see ihe following data sheets(docu-
SD355R: Remote test capable addressable photoelectric meni numbers):AD355(DF-52386), BG-12LX(DF-52013), CMF-
smoke detector for use with DNR(W)duct detector housing. 300-6(DF-52365),CRF-300-6(DF52374),CMF/CRF Series(DF-
52130), CP355(DF-52383), H355 Series (DF-52385), 1300 (DF-
H355:Fast-response,low-profile heat detector. 52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10
H355R: Fast-response, low-profile heat detector with rate-of- (DF-52347), MMF-302-6 (DF52356), SD355/SD355T (DF
rise option. 52384).
H355HT: Fast-response, low-profile heat detector that activates ADDRESSABLE DEVICE ACCESSORIES
at 190°F/88°C. End-of-Line Resistor Assembly (R-47K and R�.9K): The
AD355: Low-profile, intelligent, "AdapY' multi-sensor detector 47k ohm assembly supervises the MMF-300, MDF-300, MMF-
(B350LP base included). 301, and CMF-300 module circuits. The 3.9k ohm assembly
BEAM355: Intelligent beam smoke detector. supervises the MMF-302 module circuit. These resistors are
BEAM355S: Intelligent beam smoke detector with integral sen- �ncluded with each module.
sitivity test. Power Supervision Relay: Supervises the power to 4-wire
D355PL: InnovairFlex low-flow non-relay duct-detector housing; smoke detectors and notification appliances.
includes SD355R.
DNR: InnovairFlex low-flow non-relay duct-detector housing. W�ring Requirements
(Order SD355R separately.) While shielded wire is not required, it is recommended that all
DNRW: InnovairFlex low-flow non-relay duct-detector housing, SLC wiring be twisted-pair to minimize the effects of electrical
with NEMA-4 rating. Watertight.(Order SD355R separately.) interference. Refer to the panel manual for wiring details.
MMF-300: Addressable Monitor Module for one zone of nor-
mally-open dry-contact initiating devices. Mounts in standard
DF-52418:E1•1/27/12—Page 3 of 4
SYSTEM SPECIFICATIONS
System Capacity condensing) at 32°C ±2°C (90°F t 3°F). However, the useful
life of the system's standby batteries and the electronic compo-
• Intelligent Signalling Line Circuits.........................................1 nents may be adversely affected by extreme temperature ranges
• Addressable device capacity..............................................50 and humidity. Therefore,it is recommended that this system and
• Programmable software zones...........................................20 its peripherals be installed in an environment with a normal room
• Annunciators.........................................................................8 temperature of 15—27°C/60—80°F.
Electrical Specifications NFPA Standards
AC Power: MS-9050UD 120 VAC,60 Hz,3.0 A.MS-9050UDE: The MS-9050UD(E) complies with the following NFPA 72 Fire
240 VAC,50 Hz, 1.5 A.Wire size:minimum 14 AWG(2.00 mm2) Alarm Systems requirements:
with 600 V insulation.Nonpower-limited,supervised. —LOCAL (Automatic, Manual, Waterflow and Sprinkler
Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Supervisory).
Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of two —AUXILIARY (Automatic, Manual and Waterflow) (requires
18 AH batteries.) 4XTMF).
Communication Loop: Supervised and power-limited. —REMOTE STATION (Automatic, Manual and Waterflow)
(Where a DACT is not accepted, the alarm, trouble and
Notification Appliance Circuits: Terminal Block provides con- supervisory relays may be connected to UL 864 listed
nections for two NACs, Style Y (Class B) or Style Z(Class A). transmitters. For reverse polarity signaling of alarm and
Special Application power. Power-limited, supervised circuitry. trouble,4XTMF is required.)
Maximum signaling current per circuit:2.5 A.End-of-Line Resis- _pROPR1ETARY(Automatic,Manual and Waterflow).
tor:4.7k ohm,'/z watt(P/N 71252 UL listed)for Style Y(Class B)
NAC. Refer to the Fire•Lite Device Compatibility Document for —CENTRAL STATION (Automatic, Manual and Waterflow,
listed compatible devices. and Sprinkler Supervised).
Two Programmable Relays and One Fixed Trouble Relay: —OT,PSDN(Other Technologies,Packet-switched Data Net-
Contact rating: 2.0 A (�3 30 VDC (resistive), 0.5 A � 30 VAC Work)
(resistive). Form-C relays,nonpower-limited,nonsupervised.
Agency Listings and Approvals
Cabinet Specifications The listings and approvals below apply to the basic MS-
Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.72" 9050UD(E) control panel. In some cases, certain modules may
(1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" not be listed by certain approval agencies, or listing may be in
(42.29 cm.)wide x 5.25" (13.34 cm.)deep.Trim Ring(TR-CE): Process.Consult factory for latest listing status.
=- 22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • UL:S624
• FM approved
Shipping Specifications • CSFM:7165-0075:210
Weight: 26.9 Ibs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) • MEA:442-06-E
high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. NOTE:See DF-60445 for ULC-listed model.
Temperature and Humidity Ranges
This system meets NFPA requirements for operation at 0 —
49°C/32—120°F and at a relative humidity 93%t 2%RH(non-
FireLite� Alarms� and System Sensor� are registered trademarks oi
Honeywell International Inc. MicrosoflC� and Windows� are registered
trademarks of the Microsoft Corporation.
002012 by Honeywell International Inc.All rights reserved.Unauthorized use
of this document is strictly prohibited.
'�O 9001 This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements. ��
EN6INEERIN6 8 MANIIFACNAIN6 All specifications are subject to change without notice. �
QUALITY SYSiEMS MadeintheU.S.A.
For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105.
www.firelite.com
Page 4 of 4—DF-52418:E1•1/27/12
Install Portal - Tyco Integrated Security Page 1 of 1
�ty�coedSecurity Install Portal
Cust#105829857,Job#02
ADVANCE AU7'O PARTS#396
WAYZATA,MN55391
Scope Of Work
Syslem Opere[ion Repla:e e�ixtine obwlete 6112 comM syrv�Al�r moni�onng panel u�ilh new MS 9�50[7D,ro Cmlomer Expxtations
monimrnser.Lave new ViM 12RI'I3P as is,FA points have aUewh been removed.f�:usting Complete a.�mon as pisnblz.Get ins�:[ions/cuswmer u
panelis6112
Site Conditlon5 �:����� '�e o for business.Rrniovc oW 6112 wmbo 1�viN s nnkler 'Ls m�d move to Ke��Contacts 7yco In�egls0.vl S�t:urity ConmcLs',�,Insmlla[ion Coordin,
�s� � P�2 p �� .�2125.Jce mast be called imm�iuteh u I th
ne���aAdr�ssable pa�el.Add modules for nch(3)su'ikh.Wata Ilow,gate valve and PI V.Wue ' pon artiva on
as bern a�kled J needed.Use e.�isting wire il possible. Olsen 20i-943-6538.Call for Code or s�stem deiign yue
Cttavolo 20i.9JU.7338�Nauonal Accoun[Mnnager-Mi
hodiu:t Support Gmuµfor T.xhnical suppott 8�7 2]0 d-
ProgrcmminK tire.
Srar�dard pro@cwnnilng.Program Wel¢flow,pull slallon end smoke detecmr as nn alarm Gate
and PN valve as a supervison'.Prograni hom stmt+c lor any elnm�. 7ruining Expecm�ions
Tain onsi�e mmu¢emenU supervisory persomel on use o
Existing Equipmenl
E�isling Hudionics 6112 a'iW 3 tlre point,ehunging m Fvelite M590iUW xith c<II Lack up IX)
NOI'MAKI�.ANY CHAN(71�:5 TO NF,W VISTn 128 F➢P.I"I'EIAS NO I�A P()INTS ON IT. po�umeotation Needs
RaoN ol completion once tested,cmiticd and inspecteal
marf:cd up�mint for creation of as builLs if zyuipmrnt loc:
Customer Responei
.Custom�i ro be r�sp�nsible(or elenncal 120v po�+�tr to�his loca�on,iCnot in pla<e.
Gcneral Commenb
La��out is for spnMler onitoring but bcd aulhonn mo�
deiamiml in review pmcess.
https://tip.tycois.com/job/sow/12387349 8/8/2017
DF-52384:D•E-160
SD355(A) Series � FII''�•LITemALarl'Y1S
Addressable Photoelectric
Smoke Detectors b�/ �""�OI'le�/We��
.
General
The SD355(A), SD355T(A), and SD355R(A) addressable,
low-profile plug-in photoelectric detectors use a state-of-the-
art photoelectric sensing chamber with communications to
provide open area protection and are used exclusively with
Fire•Lite's Addressable Fire Alarm Control Panels (FACPs).
The SD355T(A)adds thermal sensors that will alarm at a fixed ( � a
temperature of 135°F (57°C). Since these detectors are �" z
addressable, they will help emergency personnel quickly �
locate a fire during its early stages, potentially saving precious � � / m'
rescue time while also reducing property damage. Two LEDs
on each sensor light to provide a local, visible sensor indica- "�
tion. Remote LED annunciator capability is available as an "
optional accessory, PN RA100Z(A). The SD355R(A) is a SD355(A) in B210LP(A) Base
remote test capable detector for use with D355PL(A) or
DNR(A)/DNRW duct smoke detector housings.
Features OPTIONS
• Remote LED output connection, PN RA100Z(A).
SLC LOOP
• Two-wire loop connection. App�ICat1011S
• Unit uses base for wiring. Use photoelectric detectors in life-safety applications to pro-
ADDRESSING vide a broad range of fire-sensing capability, especially where
smoldering fires are anticipated. lonization detectors are often
• Addressable by device. better than photoelectric detectors at sensing fast, flaming
• Rotary, decimal addressing: 01 –99 with MS-9200UD(LS), fires.
and 01 –159 with MS-9600UD(LS).
ARCHITECTURE Construction
• Unique single-source, dual-chamber design to respond These detectors are constructed of off-white fire resistant plas-
quickly and dependably to a broad range of fires. tic. SD355(A) series plug-in, low-profile smoke detectors are
Sleek, low-profile design. designed to commercial standards and offer an attractive
� appearance.
• Integral communications and built-in type identification.
• Built-in tamper-resistant feature. �nstallation
• Removable cover and insect-resistant screen for simple SD355(A) series plug-in detectors use a detachable mounting
field cleaning. base to simplify installation,service and maintenance.
OPERATION Mount base (all base types) on an electrical backbox which is
• Withstands air velocities up to 4,000 feet-per-minute(20 m/ at least 1.5" (3.81 cm)deep. For a chart of compatible junction
sec.)without triggering a false alarm. boxes,see DF-60059.
• Factory preset at 1.5% nominal sensitivity for panel alarm NOTE:Because of the inherent supervision provided by the SLC
threshold level. loop, end-of-line resistors are not required. Wiring "T-taps" or
• Visible LED "blinks"when the unit is addressed (communi- branches are permitted for Style 4 (C/ass B) wiring. SD355R(A)
cating with the fire panel)and latches on in alarm. mounts in a D355PL(A)or DNR(A)/DNRW duct detector housing.
MECHANICALS Operation
• Sealed against back pressure. Each SD355(A) series detector uses one of 99 possible
• Direct surface mounting or electrical box mounting. addresses on the MS-9200UD(LS) and up to 318 (159 on
• Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 each loop) on the MS-9600UD(LS) Signaling Line Circuit
cm)octagonal box,or 4.0" (10.16 cm)square electrical box (SLC).It responds to regular polls from the system and reports
(using a plaster ring—included). its type and status.
OTHER SYSTEM FEATURES The addressable photoelectric sensor in the SD355(A) series
has a unique unipolar chamber that responds quickly and uni-
• Fully coated circuit boards and superior RF/transient pro- formly to a broad range of smoke conditions. It can withstand
tection. wind gusts up to 4,000 feet-per-minute (20 m/sec.) without
• 94-VO plastic flammability rating. sending an alarm level signal. Because of its unipolar cham-
• Low standby current. ber, the SD355(A) series is approximately two times more
responsive than most photoelectric sensors. This makes it a
more stable detector.
DF-52384:D•2/11/2015—Page 1 of 2
Detector Sensitivity Test SD355RA: Same as SD355R with ULC Listing for use with a
D355PLA or DNRA duct detector housing; 6210LPA base
Each detector can have its sensitivity tested (required per included.
NFPA 72,Chapter 14 on Inspection, Testing and Maintenance)
when installed/connected to a MS-9200UD(l.S) or MS- INTELLIGENT BASES
9600UD(LS)addressable fire alarm control panel.The results NOTE:`A"suffix indicates ULC Listed model.
of the sensitivity test can be printed off the MS-9200UD(LS)or
MS-9600UD(LS)for record keeping. NOTE:The detector's plug-in base can be changed off for special
applications. For details about inteiligent bases and their mount-
ing,see DF-60059.
Specification 6210LP(A): Plug-in detector base (included); standard U.S.
Voftage range: 15-32 VDC(peak). flanged low-profile mounting base.
Standby current:300 NA C�3 24 VDC. B210LPBP:Bulk pack of B210LP;package contains 10.
LED current:6.5 mA� 24 VDC(latched"ON"). B501(A):Standard European flangeless mounting base.
Air velocity:4,000 ft./min.(20 m/sec.)maximum. 8501 BP:Bulk pack of 8501;package contains 10.
Size:2.1"(5.33 cm)high;base determines diameter. 8200SR(A): Intelligent sounder base capable of producing
-6210LP(A):6.1"(15.5 cm)diameter. sound output with ANSI Temporal 3 or continuous tone.
-B501(A):4.1"(10.4 cm)diameter. Replaces 6501 BH series bases in retrofit applications.
-B200SR(A):6.875"(17.46 cm)diameter. B224RB(A): Plug-in System Sensor relay base. Screw termi-
-6224RB{Aj:6.2"(15.748 cm)diameter. nals:up to 14 AWG(2.0 mm2).Relay type:Form-C.Rating:2.0
A � 30 VDC resistive; 0.3 A � 110 VDC inductive; 1.0 A �
Weight:3.6 oz.(102 g). 30 VDC inductive.
Operating temperature range: for SD355(A): 0°C to 49°C g224B1(A): Plug-in System Sensor iso/afor detector base.
(32°F to 120°F); for SD355T(A):0°C to 38°C(32°F to 100°F). Maximum 25 devices between isolator bases(see DF-52389).
SD355R(A):installed in a DNR(A)/DNRW-20°C to 70°C(-4°F
to 158°F). ACCESSORIES
Temperature:0°C-49°C(32°F-120°F). F110: Retrofit flange to convert B210LP(A) to match the
B350LP(A) profile, or to convert older high-profile bases to
Relative humidity: 10%-93%,non-condensing. low-profile.
Listings F110BP:Bulk pack of F110;package contains 15.
Listings and approvals below apply to the SD355(A), F210: Replacement flange for B210LP(A)base.
SD355T(A), and SD355RT(A) detectors. In some cases, cer- RA100Z(A): Remote LED annunciator.3-32 VDC.Mounts to
tain modules may not be listed by certain approval agencies, a U.S. single-gang electrical box. For use with B501(A) and
or listing may be in process. Consult factory for latest listing B210LP(A)bases only.
status. SMB600:Surface mounting kit
• UL Listed:S1059. M02-04-OO:Test magnet.
• ULC Listed:S1059. M02-09-00:Test magnet with telescoping handle.
• CSFM:7272-0075:0194. XR2B: Detector removal tool. Allows installation and/or
• MEA:243-02-E. removal of detector heads from bases in high ceiling applica-
• FM approved. tions.
XP-4: Extension pole for XR26. Comes in three 5-foot
Product Line Information (1.524 m)sections.
NOTE:'A"suffix indicates ULC Listed model. T55-127-010: Detector removal tool without pole.
SD355: Addressable photoelectric detector; B210LP base BCK-2006: Black detector covers for use with SD355(A)only;
included. box of 10.
SD355A: Sames as SD355 with ULC Listing; 6210LPA base WCK-200B: White detector covers for use with SD355(A)
included. only;box of 10.
SD355T: Same as SD355 but with thermal element; 8210LP
base included.
SD355TA: Same as SD355T with ULC Listing; B210LPA base
included.
SD355R: Remote test Capable addressable photoeleCtriC FireLite�Alarms is a registered trademark of Honeywell International Inc.
detector for Use wlth a D355PL(A) Or DNRA/DNRW duCt 002015 by Honeywell International Inc.All rights reserved.Unauthorized use
detector housing;B210LP base included. of tnis document is strictly pronibited.
I�O �oo� This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
- We cannot cover all specific applications or anticipate all requirements.
BYCII�EBIINi B MAfY1FI�T1AIN6 All specifications are subject to change without notice.
QUALITY SYSTEMS
For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105.
www.firelite.com
Page 2 of 2-DF-52384:D•2/11/2015
DF-52121:E•E-325
MMF-300(A) Series,
MDF-300 � F��'��TC�`ALarCY1S
Addressable Monitor Modules by Honeywell
� -
General
Four different monitor modules are available for Fire•Lite's
;.,.�.,:w,.,.,&�i
intelligent control panels to suit a variety of applications. Moni- > `` �,.w,i
tor modules are used to supervise a circuit of dry-contact input ° ` ` t
devices,such as conventional heat detectors and pull stations, �L ! , '°"' �
or monitor and power a circuit of two-wire smoke detectors � y ' � 0�> �
(MMF-302(A)). 1�E"" �µ�. ��M
MMF-300(A)is a standard-sized module(typically mounts to a ��_�-�*�
4" [10.16 cm] square box) that supervises either a Style D �«�
(Class A) or Style B (Class B) circuit of dry-contact input '�`",�, 5,��-'*�
devices. ,�..�-,��,��.,....�.,,....o
MMF-301(A)is a miniature monitor module a mere 1.3"(3.302 �•�•� ��,.:
cm) H x 2.75" (6.985 cm)W x 0.65" (1.651 cm) D that super- o,'° `` � '�;
vises a Style B(Class B)circuit of dry-contact input devices.Its ,� t,��, J Wp�� -
compact design allows the MMF-301(A) to be mounted in a �,� � ,,,�,
single-gang box behind the device it monitors. a
;� g
MMF-302(A) is a standard-sized module used to monitor and � �� .,,_;.. _ .___._ __ .,::�;,_;>`
supervise compatible two-wire, 24 volt, smoke detectors on a �'`' - �""�` �`
Style D(Class A)or Style B(Class B)circuit. `' �'� `U
MDF-300(A) is a standard-sized dual monitor module used to MMF-300(A)(Type H)
monitor and supervise two independent two-wire Style B
(Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit
separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B (Class B)or Style D (Class
tems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor
LiteSpeedT"" is a communication protocol developed by (provided)terminates the Style B circuit.No resistor is required
Fire•Lite Engineering that greatly increases the speed of com- for supervision of the Style D circuit.
munication between analog intelligent devices. Intelligent MMF-300(A) OPeRar�oN
devices communicate in a grouped fashion. If one of the
devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module
stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from
net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor-
other communication protocols. mal/short)of its Initiating Device Circuit(IDC).A flashing LED
indicates that the module is in communication with the control
MMF-300(A) Monitor MOdule panel. The LED latches steady on alarm (subject to current
limitations on the loop).
• Built-in type identification automatically identifies this device
as a monitor module to the control panel. MMF-300(A)SPECIFICATIONS
• Powered directly by two-wire SLC loop. No additional Nominal operating voltage: 15 to 32 VDC.
power required. Maximum current draw: 5.0 mA(LED on).
• High noise(EMF/RFI)immunity. Average operating current: 375 NA (LED flashing), 1 com-
• SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL.
• Direct-dial entry of address: 01 — 159 on MS-9600 series Maximum IDC wiring resistance: 1500 Ohms.
panels,01 —99 on other compatible systems.
• LED flashes during normal operation and latches on steady Maximum IDC Voltage: 11 Volts.
to indicate alarm. EOL resistance:47K Ohms.
The MMF-300(A) Monitor Module is intended for use in intelli- Temperature range:32°F to 120°F(O�C to 49°C).
gent, two-wire systems, where the individual address of each Humidity range: 10°/o to 93%noncondensing.
module is selected using the built-in rotary switches. It pro-
vides either a two-wire or four-wire fault-tolerant Initiating Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x
Device Circuit (IDC)for normally-open-contact fire alarm and 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x
supervisory devices. The module has a panel-controlled LED 2•125"(5.398 cm)deep box.
indicator. The MMF-300(A) can be used to replace M300(A)
modules in existing systems. MMF-301(A) Mini Monitor Module
MMF-300(A)APPLICAT/ONS • Built-in type identifcation automatically identifies this device
Use to monitor a zone of four-wire smoke detectors, manual as a monitor module to the panel.
fire alarm pull stations, waterflow devices, or other normally- • Powered directly by two-wire SLC loop. No additional
open dry-contact alarm activation devices. May also be used power required.
to monitor normally-open supervisory devices with special • High noise(EMF/RFI)immunity.
DF-52121:E•07/30/2015—Page 1 of 4
• Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power
• Direct-dial entry of address: 01 — 159 on MS-9600 series source.
panels,01 —99 on other compatible systems • High noise(EMF/RFI)immunity.
___ • SEMS screws with clamping plates for ease of wiring.
3 14�5 0 � 0 � • Direct-dial entry entry of address: 01 — 159 on MS-9600
� �g 2 2 series panels,01 —99 on other compatible systems.
3 12 3 3 • LED flashes during normal operation.
� �� O 4 � O 4 • LED latches steady to indicate alarm on command from
1
control panel.
9 8 � 6 9 8 � 6 The MMF-302(A)Interface Module is intended for use in intelli-
TENS ONES
gent, addressable systems, where the individual address of
; each module is selected using built-in rotary switches. This
module allows intelligent panels to interface and monitor two-
wire conventional smoke detectors. It transmits the status
Y (normal, open, or alarm) of one full zone of conventional
� � � � detectors back to the control panel. All two-wire detectors
� ) ap being monitored must be UL compatible with the module.The
MMF-302(A) can be used to replace M302(A) modules in
existing systems.
MMF-302(A)AaaucanoNs
Use the MMF-302(A) to monitor a zone of two-wire smoke
The MMF-301(A) Mini Monitor Module can be installed in a detectors. The monitored circuit may be wired as an NFPA
single-gang junction directly behind the monitored unit. Its Style B(Class B)or Sryle D(Class A)Initiating Device Circuit.
small size and light weight allow it to be installed without rigid A 3.9 K Ohm End-of-Line Resistor (provided) terminates the
mounting. The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A) circuit(maximum IDC
two-wire systems where the individual address of each module loop resistance is 25 Ohms). Install ELR across terminals 8
is selected using rotary switches. It provides a two-wire initiat- and 9 for Style D application.
ing device circuit for normally-0pen-contact fire alarm devices.
The MMF-301(A)can be used to replace M301(A)modules in MMF-302(A)OPERATION
existing systems. Each MMF-302(A) uses one of the available module
MMF-301(A)APPLICATIONs addresses on an SLC loop. It responds to regular polls from
the control panel and reports its type and the status(open/nor-
Use to monitor a single,device or a zone of four-wire smoke maVshort)of its Initiating Device Circuit(IDC).A flashing LED
detectors, manual fire alarm pull stations, waterflow devices, indicates that the module is in communication with the control
or other normally-open dq/;�ontact devices.May also be used panel. The LED latches steady o�,alarm (subject to curcent
to monitor normally-open.,,supervisory devices with special limitations on the loop). .,
supervisory indication at the control panel. Monitored circuiU
device is wired as an NFPA Style B(Class B)Initiating Device MMF-302(A)SPec�FlCATIon►s
Circuit.A 47K Ohm End-of-Line Resistor(provided)terminates Nominal operating voltage: 15 to 32 VDC.
the circuit. Maximum current draw:5.1 mA(LED on).
MMF-$O'I(A�OPERATION Maximum IDC wiring resistance:25 Ohms.
Each MMF-301(A) uses one of the available module p�erage operating current: 270 NA, 1 communication and 1
addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol.
the control panel and reports its type and the status(open/nor-
mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3.9K Ohms.
MMF-301(A)SPECIF�CaT1oNS External supply voltage(between Terminals T10 and T11):
Nominal operating voltage: 15 to 32 VDC. • DC voltage:24 volts power limited.
Average operating current: 350 uA, 1 communication every ' Ripple voltage:0.1 Vrms maximum.
5 seconds, 47k EOL; 600 NA Max. (Communicating, IDC ' Current:90 mA per module maximum.
Shorted). Temperature range:32°F to 120°F(0°C to 49°C).
Maximum IDC wiring resistance: 1500 Ohms. Humidity range: 10%to 93%noncondensing.
Maximum IDC Voltage: 11 Volts. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x
Maximum IDC Current:450 NA. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x
2.125"(5.398 cm)deep box.
EOL resistance:47K Ohms.
Temperature range:32°F to 12o°F(o°C to 4s°C). MDF-300(A] Dual Monitor Module
Humidity range: 10%to 93%noncondensing. The MDF-300(A) Dual Monitor Module is intended for use in
Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x intelligent, two-wire systems. It provides two independent two-
0.65"(1.651 cm)deep. wire initiating device circuits(IDCs)at two separate,consecutive
addresses.It is capable of monitoring normally open contact fire
Wire length:6"(15.24 cm)minimum. alarm and supervisory devices.The module has a single panel-
controlled LED.
MMF-302(A) Interface Module
• Supports compatible two-wire smoke detectors.
Page 2 of 4—DF-52121:E•07130/2015
NOTE: The MDF-300(A)provides iwo Style 8 (Class 8) IDC cir- MDF-300(A): Monitor module, dual,two independent Class B
cuits ONLY. Style D (Class A) IDC circuifs are NOT supported in circuits.
any application.
SM6500:Optional surface-mount backbox.
MDF-300(A)SPECIFICATIONS NOTE: See installation instructions and refer to the SLC Wiring
Nortnal operating voltage range: 15 to 32 VDC. Manual,PN 51309.
Maximum current draw:6.4 mA(LED on).
Architects'/Engineers' Specifications
Average operating current:750 NA(LED flashing).
Maximum IDC wiring resistance: 1,500 Ohms. Specifications of these devices and all FireLite products are
available from FireLite.
Maximum IDC Voltage: 11 Volts.
Maximum IDC Current:240 NA
EOL resistance:47K Ohms.
Temperature range:32°to 120°F(0°to 49°C).
Humidity range: 10%to 93%(non-condensing).
Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x
1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x
2.125"(5.398 cm)deep box.
MDF-300(A)AUTOMATIC ADDRESSING
The MDF-300(A) automatically assigns itself to two address-
able points, starting with the original address. For example, if
the MDF-300(A) is set to address "26", then it will automati-
cally assign itself to addresses"26"and"27".
NOTE: "Ones"addresses on the MDF-300(A) are 0, 2, 4, 6, or 8
only. Terminals 6 and 7 use the first address,and terminals 8 and
9 use the second address.
CAUTION:
Avoid duplicating addresses on the system.
Installation
MMF-300(A), MM'F-302(A), and MDF-300(A) modules mount
directly to a standard 4"(10.16 cm)square,2.125"(5.398 cm)
deep, electrical box. They may also be mounted to the
SMB500 surface-mount box. Mounting hardware and installa-
tion instructions are provided with each module. All wiring
must conform to applicable local codes,ordinances,and regu-
lations. These modules are intended for power-limited wiring
only.
The MMF-301(A)module is intended to be wired and mounted
without rigid connections inside a standard electrical box. All
wiring must conform to applicable local codes, ordinances,
and regulations.
Agency Listings and Approvals
In some cases, certain modules may not be listed by certain
approval agencies, or listing may be in process. Consult fac-
tory for latest listing status.
• UL:S2424.
• ULC: S2424.
• FM Approved.
• CSFM:7300-0075:0185.
• MEA:72-01-E.
Product Line Information
NOTE:'A"su�x indicates ULC-listed model.
MMF-300(A): Monitor module.
MMF-301(A): Monitor module,miniature.
MMF-302(A): Monitor module,two-wire detectors.
DF-52121:E•07/30/2015—Page 3 of 4
DATE TIME
CITY OF ORONO CALLED IN ��
INSPECTION NO E SOHEouLED (rs/'G//'� I � 3�9
PERMR NO. 1�1 � VO�� COMPLETED
ADDRESS �� � S����`^� `D,r
OWNER ,s�i�.c�cr� �-� �� TELEPHONE NO.
CONTRACTOR T��► �+���
� DESCRIPTION �'�1✓� p—�-��� l J '�- �� ��`"`�
�y ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL
Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING
O ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL
Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION
Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS
� ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑COMPLAINT
Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP
41 ❑AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL
J ❑ DEMO-SITE ❑�PTIC INSTALL
2 OlMN�KTAACT'OR TO MEET Y�U: YES_NO
� COMMENT�
4 i='n«.� �-•... n t.�.� n�.� ���
� ����� ��� � �
0
�
�
W
�
� )�
� K�,T„ �oK S�r�`G � � 3�SS�
W ` V
� ��• .T_(,�v-u w �� 1 .� S
�
�
,
4�j ❑WORK SATISFACTORY:PROCEED �PROJECT(�MPLETE
� ❑OORRECT WORK 3 PROCEED O ISSUE CERTIFICATE OF OCCUPANCY
W
OO ❑COqRECT WORK�u�REINSPECTION TEMPORARY
V BEFORE CdNERINO PERMANENT
❑CORRECTUNSAFECON01710NWfTHIN H��• O PHOTOTAKEN
INSPECTOR WILL RETURN
O STOP ORDER POSTED.CALL INSPECTOR ❑pTATION ISSUED
D INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
caa ror u�e�t 24 hours in advance. (952) 249-4600
own�IComrector on sna , o�•,�•
�11g�6Ct0�: ��'.a.L� �i�.-� ���l
WMb CaPYMtpsCto�s FlM C�nary CopylSib Notbs