HomeMy WebLinkAbout2006-fire/safety inspection � I� � .} �-`j ��
OCCUPANCY: DATE: � KNOX: TYPE:
(�--� C�L��'`� i .�-�� 1 �o D �
REIN P: SPIZ SY9: � ALARM: �
/ a-C�p y
ADDRE85: \� y(� EM RGENCY �`— �
S • s �� IU�-� N � V CONTAC'T' �A�/ �I
PHONE: ��� ' �� ` O �� � EMERQENCY �� ' , i ��' � �
( PHONE iOE: �L
Inspection of the oxupancy listed above been DEEPHAVEN COMMENTS:
completed in axordance with the 2000 IFC and DCCELSIOR
the MSFC adopted by the city of:»»»» GREENWOOD
The followi� violations and/or deficienci �SHOREWOOD
r uirin aorrective ection are noted below. �� � TONKA BAY
EXTERIOR: # FIRE PROTECTION SYSTEMS: #
Address visible and le ible-Front and rear doors 1 S rinkler heads in ood condition- ro er covera e 21
Fire h drants accessible-36" minimum clearance 2 Door to s rinkler tem control room marked
Fire lanes-Fire De artment access 3 Riser 8 control valves accessible/current ins tio 23
FDC unobstructed&visible- ro er ca -3'clear 4 Control valves lodced o n or tam er rotected 24
Hom/strobe o rational-unobstructed 8 visible 5 Extin uishers ro rl located-current ins ection 25
Knox Box with ro rl labeled ke s 6 Commercial hood tems-clean 8�ins ected 26
Dum ters minimum 5'from buildin 7 Class K extin uisher resent in commercial kitchen 27
Gas meters & i in rotected 8 Fire alarm tem in ood condition-ins ected 28
Buildin exterior maintained 9 Door to fire alarm room identified 29
IXITS: # INTERIOR/STORAGE: #
Exit doors unobstructed, o rable, ro er hardware 10 Stora e 18" or more below s rinkler heads 30
Exit corridors maintained and unobstructed 11 Stora e 24" or more below un rotected ceilin s 31
Exit si ns illuminated 12 No stora e in un rotected attics or below stairs 32
Pro exit si ns dis la ed-6" minimum letters 13 No stora e in mechanical or electrical anel rooms 33
Emer en li htin in ood o eratin condition 14 No stora e in boiler or elevator ui ment rooms 34
Occu n load osted (assembl ) 15 Trash &oil ra s o I ke t or removed dail 35
ELECTRICAL E UIPMENT: # Flammable and combustible li uids ro erl stored 36
Door to electrical room/ nel labeled 16 Hazardous materials ro rl stored and identified 37
30" clear access to electrical anels 17 Com ressed as inders ro rl secured 38
Open spaces in electrical panels-knockout lugs 18 Ceiling tiles in place 8�undamaged 39
Electrical hazards- ower stri /circuit rotected 19 Wall or ceilin dama e re ired/seal enetrations 40
No extension cords used as ermanent wirin 20 Smoke detectors operational/ ro er location 41
C e�olation Summa :
��/ �� �dC, C��N v�� :L n>� .
��t'r � ��J J-� ."'�.�.;,,� '
., ..
:�-� C�-��t-,� �' �--- %�� G�ti
�-= .. � ,..._` L7`l
The Fire District reaerves the right to enforce the
MSFC if any other violationa are discovered du�ing
the compliance process or as they may ariae.
� ignature indicates receipt of copy
� � X � and cooperation with compliance
owner or Fiepres�,tativ�e uor istrict or ord@fs_within �� days.