Loading...
HomeMy WebLinkAbout2016-00352 - fire systems CITY OF ORONO * Z 0 1 6 - 0 0 3 5 2 * ' 2750 KELLEY PARKWAY DATE ISSUED: 04/14/2016 ORONO, MN 55356- (952) 249-4600 FAX: (952) 249-4616 ADDRESS : 3382 SHORELINE DR PIN : 17-117-23-44-0100 LEGAL DESC : TOWNSITE OF LANGDON PARK : LOT 005 BLOCK 003 PERMIT TYPE : FIRE SYSTEMS PROPERTY TYPE : COMMERCIAL-BUSINESS CONSTRUCTION TYPE : SPRINKLER SYSTEM-IN BUILDING NOTE: INSPECTIONS ARE DONE BY FIRE MARSHALL,JAMES VAN EYLL. PLEASE CALL JAMES VAN EYLL DIRECTLY AT:(952)473-9701 TO SET UP AN INSPECTION. PERMIT FOR:3380 SHORELINE DR ENTER THE VALUTATION 11000 APPLICANT FIRE SPRINKLER-COMMERCIAL 137.50 STATE SURCHARGE VAL OTHER 5.50 OLSEN FIRE PROTECTION,INC. MAIL-IN FEE 1.50 321 WILSON ST NE MINNEAPOLIS,MN 55413- TOTAL 144.50 (612)290-4700 Payment(s) Minnesota State License#: FIRE-0045 CHECK 21440 144.50 OWNER Narrows LLC PO BOX 36 NAVARRE,MN 55392- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permiks. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within l80 days of the date of issuance,or if construction is suspended for a period of 180 days at any time afrer work has commenced. The applicant is responsible for assuring all required inspections are requested in confortnance with the State Building Code.This permit may be revoked at any time for due cause. C,�'��iC-G�--(.,�-L�,) L i � � �=> Applicant Permitee Signature ' Date Issu d S gnature Date �1,���i(� ��''p`'��` City of Orono F�E ortt,Y �� �Y 1 P.O.Box 66 Date Received: � Permit# ����°� �� �`�Z- '` 2750 Kelley Parkway � �a li �-'� �'� Amount: $' �� ]� � . G�. Crystal Bay,MN 55323 . ���oa�j (952)249-4600 �1�,L�.Y�a,�.rc- ,v� d.-r.z.�,�„e 2. � Approved By: K�/" Recommendsc A roval Denial ❑ CITY OF ORONO—�AUTOMATIC FIRE SPRINKLER/GENERAL PERNIIT (All peilnits must be app�oved by the I'irc hinrslialf and/or Building OfFicixl) 1. Permits are required for all fire sprinkler installation and repair. All work shall be done by a licensed fire sprinkler contractor. Two sets of plans, specification data sheets, fire flow tests and hydraulic calculation sheets shall be subinitted to the Orono Fire Marshal a miniinuin of�7 da,�s Uefore start of worlc. 2. Pennits can be applied for by mail at PO box 66, Orono, MN, 55323 or in person at, 2750 Kelly Parkway ; phone: (952) 249-4600. Pennits are also available online at: www.ci.orono.i�.us 3. All systems shall be designed, installed and maintained to N.F.P.A.-13,N.F.P.A.-25, Minnesota State Building Code,Minnesota State Fire Code and Standards. All attic systeins are to be spaced at a rnaxunum 130 square foot coverage. Plastic pipe will not be allowed at any time in attic spaces. 4. All equipinent installed shall be U.L. or F.M. approved for fire p:otection service.W ater flow test shall be coinpleted on all new systems. Water flow test reports shall be submitted to the Orono Fire Marshal along with plan submittal. 5. Yard or wall post indicator valves are required. All indicating and control values installed shall be provided with tamper protection. On dry systeins, the control vaive to service the pressure switch(air) shall be supervised. 6. Inspectors test valve shall be installed on each floor level or zone of system. All systems shall have main drain and inspectors test valves piped to the outside. 7. No water is to be introduced into the sprinkler system until main has been thoroughly flushed. 200# air test and flushing shall be witnessed by the City of Orono Water Department. 8. An approved audible/visual device wired to main flow switch shall be installed above F.D. connection and in areas normally occupied by tenants. 9. EXISTING SYSTEMS: If any changes in the hydraulically most demanding area,change in occupancy classification or an addition of 20 or more heads, hydraulic calculations and flow test will be required. 10. The Orono Fire Marshal shall witness all final flow or trip tests. Appointments can be made by calling(952)4�3-9�34, 8:00-4:00 p.m.Monday-Friday. 24-hours notice is requested. d��—{9K�t� 11. When required, (30 foot building height) stairwell standpipe's shall have 2 Yz gate valves installed with 2 '/z x 1 %z caps. 6/I/2004 j - ' �L�TO1�I_�TIC FIRE SPRLNKLER PER�YIITS . � t�1 l.�'� '''- ;:��i ✓ � �;;Please Cbecic.One: - - ❑ New ❑ Addition � Remodel ❑ Replace Job Site./,Own,er Information: ' _ ,< , ���� ���z Site Address: _- �' � �i �Z�� r�r` \ CZ Owner: 1� ti`�1 Mailing Address: City: ���� r�1�.j Zip: Home Phone: Altemate Phone: � 1� - P�`� ���' � Contractor/Applicaut Information Contractor/App.:�c_5�;__, ��.�,�_ ��.�,� ContactPerson: Y1����� ��,; Address: �-�Z...1 V��1,Sc-,r� 'S i 1�, State License#: ����4�� City: �`'�'�. �, Zip: �!}�� Expiration Date: C-, - "3C:;- 1 (r� Phone: �\Z. �Z'�D - 11`1�?C � Alternate Phone: ;. TYPES OF'FIRE SPRINKLER PERMITS �' � ' � Commercial—Fire S rp inkler ❑ Residential—Fire Sprinkler Fire Systems Permit Fire Systems Permit � _. *Base Price=Contract Price: � �I ,G C``; x.0125 =$ 1�`> ?, (Minimum$35.00) s c � *Surcharge=Contract Price: $ 1 1 ,c('�C_> x.0005 =� �' (Minimum $ .50) *Mail-In Fee(Only On Mail In Applications) _$ 1.50 �� c-- *Total Cost of Permit: _$ � �k�} , The undersigned herby applies to the City for issuance of a Sprinkler Systems Permit. Applicant agrees that all systems shall be designed, installed and maintained to N.F.P.A.-13,N.F.P.A.-25, Minnesota State Building Code,Minnesota State Fire Code and Standards, and certifes that all statements made on this application are complete, true and coiYect. �h����; �t-���v �-� - -7 � I ci.c� Applicant Date Reset Form • �� Page 1 ' MAIN I�.EVEL Date HYDRAUL/C CALCULATIONS for Projectname: NARROWS SALOON Location: 3380 SHORELINE DRIVE, NAVARRE, MN Drawing no: 1 Date: 4-4-2016 Design Remote area number: 1 Remote area location: MAIN FLOOR Occupancyclassification: SEATING Density: .10 - Gpm/SqFt Area of application: 900 - SqFt Coverage per sprink/er: 182 - SqFt Type of sprink/ers calculated: RECESS No. of sprinklers calculated: 8 In-rack demand: -GPM Hose streams: 100-GPM Total water required(including hose streams): 255.19 - GPM @ 43.11 - Psi Type of system: W ET Volume of dry or preaction system: - Gal Water supply information Date: 2015 Location; 3380 SHORELINE DRIVE Source: CITY& CUSTOM DESIGN FLOW TEST Name of contractor: OLSEN FIRE PROTECTION Address: 321 WILSON STREET, N.E. MPLS., MN Phone number; 612-331-3111 Name of designer: D CARLSON Authority having jurisdiction: CITY FIRE INSPECTIONS Notes:(Include peaking information or gridded systems here.) Water Supply Curve C _ _ . Page 2 MAIN LEVEL Date • City Water Supply: Demand: C1 - Static Pressure : '62 D1 - Elevation : 10.394 C2 - Residual Pressure: ''50 D2 - System Flow : 155.19 . C2 - Residual Flow : 1235 D2 - System Pressure : 43.112 Hose ( Demand ) : 100 D3 - System Demand : 255.19 Safety Margin : 18.239 150 140 130 P 120 R 110 E 100 S 90 S $� � 70 C1 R 60 C2 E 50 D2 40 30 20 10 pi 200 400 600 ; 800 1000 1200 1400 1600 1800 FLOW ( N ^ 1.85) ' Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary - � • Page 3 MAIN LEVEL Date . = Fitting Legend Abbrev. Name Yz 3/0 1 1'/a 1 Yz 2 2'/z 3 3Yz 4 5 6 8 10 12 14 16 18 2Q 24 , B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 1 i 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary - Diameter Units Inches Length Units Feet' Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a* show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings'not marked with a"will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ', Pr�s�ure / Flow Summary - STANDARD Page 4 ' MAIN �EVEL Date Node Elevation ` K-Fact - Pt � Pn Flow Density Area ' Press �� � No. Actual Actual Req. 1 24.0 5.6 10.56 na 18.2 0.1 182 7.0 2 24.0 5.6 10.85 na 18.45 0.1 182 7.0 3 24.0 5.6 12.19 na 19.55 0.1 182 7.0 4 24.0 5.6 13.28 na 20.41 0.1 182 7.0 6 24.0 5.6 11.12 na 18.67 0.1 182 7.0 7 24.0 5.6 11.42 na 18.93 0.1 182 7.0 8 24.0 5.6 12.82 na 20.05 0.1 182 7.0 9 24.0 5.6 13.97 na 20.93 0.1 182 7.0 5 24.0 15.6 na 10 24.0 16.41 na 11 24.0 19.37 na 37 12.0 31.77 na BAS 0.0 40.74 na SPG 0.0 41.13 na HYD 0.0 43.1 na 100.0 CITY 0.0 43.11 na The maximum velocity is 14.84 and it occurs in the pipe between nodes 10 and 11 _ Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ', Final;Calculations - Hazen-Williams Page 5 ' MAIN LEVEL Date Hyd -- Qa Dia. Fitting pipe _ Pi Pt _.. Ref. "C" or Ftng's Pe Pv ******* Notes '`'`"*'* Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 18.20 1.380 0.0 10.000 10.562 K Factor=5.60 to 120.0 0.0 0.0 0.0 2 18.2 0.0288 0.0 10.000 0.288 Vel = 3.90 2 18.45 1.610 5E 20.0 7.000 10.850 K Factor=5.60 to 120.0 0.0 20.000 0.0 3 36.65 0.0495 0.0 27.000 1.337 Vel = 5.78 3 19.55 1.610 0.0 10.000 12.187 K Factor=5.60 to 120.0 0.0 0.0 OA 4 56.2 0.1093 0.0 10.000 1.093 Vel = 8.86 4 20.40 1.610 T 8.0 4.000 13.280 K Factor=5.60 to 120.0 0.0 8.000 0.0 5 76.6 0.1938 0.0 12.000 2.325 Vel = 12.07 0.0 76.60 15.605 K Factor= 19.39 6 18.67 1.380 0.0 10.000 11.121 K Factor=5.60 to 120.0 0.0 0.0 0.0 7 18.67 0.0301 0.0 10.000 0.301 Vel = 4.00 7 18.93 1.610 5E 20.0 7.000 11.422 K Factor=5.60 to _ 120.0 0.0 20.000 0.0 8 37.6 0.0520 0.0 27.000 1.403 Vel = 5.93 8 20.06 1.610 0.0 10.000 12.825 K Factor=5.60 to 120.0 0.0 0.0 0.0 9 57.66 0.1145 0.0 10.000 1.145 Vel = 9.09 9 20.93 1.610 T 8.0 4.000 13.970 K Factor=5.60 to 120.0 0.0 8.000 OA 10 78.59 0.2032 0.0 12.000 2.438 Vel = 12.39 0.0 -- ---------- - -- 78.59 16.408 K Factor= 19.40 5 76.60 2.067 0.0 14.000 15.605 to 120.0 0.0 0.0 0.0 10 76.6 0.0574 0.0 14.000 0.803 Vel = 7.32 10 78.59 2.067 T 10.0 4.000 16.408 to 120.0 0.0 10.000 0.0 11 155.19 0.2119 0.0 14.000 2.966 Vel = 14.84 11 0.0 2.067 2E 10.0 14.000 19.374 to - 120.0 T 10.0 20.000 5.197 . 37 155.19 0.2119 0.0 34.000 7.203 Vel = 14.84 37 0.0 3.26 11 E 103.484 60.000 31.774 to 120.0 0.0 103.484 5.197 BAS 155.19 0.0230 0.0 163.484 3.766 Vel = 5.97 BAS 0.0 4.026 2B 24.0 2.OQ0 40.737 to 120.0 S 22.0 46.000 0.0 SPG 155.19 0.0082 0.0 48.000 0.396 Vel = 3.91 SPG 0.0 4.1 E 14.534 300.000 41.133 to 140.0 G 2.907 46.508 0.0 HYD 155.19 0.0057 T 29.067 346.508 1.965 Vel = 3.77 HYD 100.00 4.1 0.0 1.000 43.098 Qa= 100 to 140.0 0.0 0.0 0.0 CITY 255.19 0.0140 0.0 1.000 0.014 Vel = 6.20 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ', Fina� Calculations - Hazen-Williams Page 6 ' MAIN LEVEL Date Hyd. Qa Dfa. Fitting Pipe Pt Pt - � � Ref. "C" or Ftng's Pe Pv *"**`*` Notes "*"* Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 255.19 43.112 K Factor= 38.87 _ __ _ Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 1 � LOWER LEVEL Date � HYDRAUL/C CALCULATIONS � - for Projectname: NARROWS SALOON Location: 3380 SHORELINE DRIVE, NAVARRE, MN Drawing no: 1 Date: 4-4-2016 Design. Remote area number: 2 Remote area location: LOWER FLOOR Occupancy classification: SEATING Density: .10 -Gpm/SqFt Area of application: 900-SqFt Coverage per sprinkler: 182 -SqFt Type of sprinklers calculated: RECESS No, of sprinklers calculated: 11 In-rack demand: - GPM Hose streams: 100 -GPM Tota/water required(including hose streams): 320.84 - GPM @ 46.62- Psi Type of system: W ET Vo/ume of dry or preaction system; - Gal Water supp/y information Date: 2015 Location: 3380 SHORELINE DRIVE Source: CITY& CUSTOM DESIGN FLOW TEST Name of contractor: OLSEN FIRE PROTECTION Address: 321 WILSON STREET, N.E. MPLS., MN Phone number: 612-331-3111 Name of designer: D CARLSON Auth.ority having jurisdiction:CITY FIRE INSPECTIONS _ Notes:(Include peaking information or gridded systems here.) Water Supply Curve C _ . Page 2 LOWER LEVEL Date _ City Water Supply: - Demand: � C1 -Static Pressure : 62 D1 - Elevation : 5.197 C2 - Residual Pressure: 50 D2 - System Flow : 220.841 C2 - Residual Flow : 1235 D2 -System Pressure : 46.625 Hose ( Demand ) : 100 D3 -System Demand : 320.841 Safety Margin : 14.384 � 150 140 130 P 120 R 110 E 100 S 90 S 80 U �� C� R 60 C2 E 50 40 3 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N ^ 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary , . Page 3 , LOWER LEVEL Date Fitting Legend Abbrev. Name Y2 3/a 1 1'/a 1 Yz �2 2�/z 3 3Yz 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90'Standard Efbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 1 i 13 I 90'Grvd-Vic Elbow#10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 3Ei 40 S NFPA 13 Swing Check 0 0 5 7 9 1� 14 ?6 19 22 27 32 45 55 65 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with '. The fittings marked with a* show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a`will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by H.ydratec Inc. Route 111 Windham N.H. USA 03087 � . Pressure / Flow Summary - STANDARD Page 4 � LOWER LEVEL Date " 'Node Elevation `K-Fact " � pt � Pn " Flow" ` Uensity ' Area � Press " `� No. Actual Actual Req. DP 0.0 5.6 7.17 na 15.0 0.1 150 7.0 21 12.0 5.6 7.17 na 15.0 0.1 150 7.0 22 12.0 5.6 7.56 na 15.39 0.1 150 7.0 23 12.0 5.6 10.38 na 18.04 0.1 150 7.0 24 12.0 12.14 na 25 12.0 K=K�a DP1 13.01 na 19.2 26 12.0 K=K@ DP1 14.86 na 20.52 28 12.0 K=K@ DP1 16.1 na 21.36 29 12.0 K-K@ DP1 16.29 na 21.49 30 12.0 K=K@ DP1 17.08 na 22.0 32 12.0 K=K@ DP1 17.48 na 22.26 33 12.0 K=K@ DP1 17.89 na 22.52 34 12.0 K=K@ DP1 18.76 na 23.06 27 12.0 18.62 na 31 12.0 19.22 na 35 12.0 21.08 na 36 12.0 26.37 na 37 12.0 29.64 na BAS 0.0 42.07 na SPG 0.0 42.83 na HYD 0.0 46.6 na 100.0 CITY 0.0 46.63 na The maximum velocity is 21.11 and it occurs in the pipe between nodes 35 and 36 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 . Final�Calculations - Hazen-Williams Page 5 • LOWER LEVEL Date _,r.. .� .: . .. _ _ _ ... ti, : _ Hyd. t�a Dia. Fitting Pipe Pt � Ref. "C" or Ftng's Pe Pv "'*'**` Notes *"**** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn DP 15.00 1.049 2E 4.0 1.000 7.175 K Factor=5.60 to 120.0 T 5.0 9.000 0.0 DP1 15.0 0.0764 0.0 10.000 0.764 Vel = 5.57 0.0 15.00 7.939 K Factor= 5.32 21 15.00 1.049 E 2.0 3.000 7.175 K Factor=5.60 to 120.0 0.0 2.000 0.0 22 15.0 0.0764 0.0 5.000 0.382 Vel = 5.57 22 15.39 1.049 0.0 10.000 7.557 K Factor=5.60 to 120.0 0.0 0.0 0.0 23 30.39 0.2822 0.0 10.000 2.822 Vel = 11.28 23 18.05 1.380 E 3.0 1.000 10.379 K Factor=5.60 to 120.0 T 6.0 9.000 0.0 24 48.44 0.1758 0.0 10.000 1.758 Vel = 10.39 24 0.0 1.610 0.0 10.500 12.137 to 120.0 0.0 0.0 0.0 25 48.44 0.0830 0.0 10.500 0.872 Vel = 7.63 25 19.20 1.610 0.0 12.000 13.009 K Factor @ node DP1 to 120.0 0.0 0.0 OA 26 67.64 0.1539 0.0 12.000 1.847 Vel = 10.66 26 20.52 1.610 E 4.0 3.000 14.856 K Factor @ node DP1 to 120.0 T 8.0 12.000 0.0 27 88.16 0.2512 0.0 15.000 3.768 Vel = 13.89 0.0 88.16 18.624 K Factor= 20.43 � 28 21.36-- 1.610 0.0 10.500 16.099 K Factor @ node DP1 to 120.0 0.0 0.0 0.0 29 21.36 0.0182 0.0 10.500 0.191 Vel = 3.37 29 21.49 1.610 0.0 12.000 16.290 K Factor @ node DP1 to 120.0 0.0 0.0 0.0 30 42.85 0.0662 0.0 12.000 0.794 Vel = 6.75 30 22.00 1.610 E 4.0 3.000 17.084 K Factor @ node DP1 to 120.0 T 8.0 12.000 0.0 31 64.85 0.1424 0.0 15.000 2.136 Vel = 10.22 0.0 64.85 - 19.220 K Factor= 14.79 32 22.26 1.610 2E 8.0 13.000 17.481 K Factor @ node DP1 to 120.0 0.0 8.000 0.0 33 22.26 0.0197 0.0 21.000 0.414 Vel = 3.51 33 22.52 1.610 0.0 12.000 17.895 K Factor @ node DP1 to 120A 0.0 0.0 0.0 34 44.78 0.0718 0.0 12.000 0.861 Vel = 7.06 34 23.05 1.610 E 4.0 3.000 18.756 K Factor @ node DP1 to 120.0 T 8.0 12.000 0.0 35 67.83 0.1547 0.0 15.000 2.321 Vel = 10.69 0.0 67.83 21.077 K Factor= 14.77 27 88.16 2.067 0.0 8.000 18.624 to 120.0 0.0 0.0 OA 31 88.16 0.0745 0.0 8.000 0.596 Vel = 8.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 , Fir�a�.Calculations - Hazen-Williams Page 6 � LOUN�R LEVEL Date Hyd. c`�a via. Fitting Pipe Pt Pt , _ _ ._, .._ , �„ Ref. "C" or Ftng's Pe Pv """*** Notes *'*"'`'` Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 31 64.85 2.067 0.0 9.000 19.220 to 120.0 0.0 0.0 0.0 35 153.01 0.2063 0.0 9.000 1.857 Vel = 14.63 35 67.83 2.067 21 7.0 6.000 21.077 to 120.0 0.0 7.000 0.0 36 220.84 0.4069 0.0 13.000 5.290 Vel = 21.11 36 0.0 2.635 I 8.237 18.000 26.367 to 120.0 0.0 8.237 0.0 37 220.84 0.1247 0.0 26.237 3.273 Vel = 12.99 37 0.0 3.26 11 E 103.484 60.000 29.640 to 120.0 0.0 103.484 5.197 BAS 220.84 0.0442 0.0 163.484 7.233 Vel = 8.49 BAS 0.0 4.026 2B 24.0 2.000 42.070 , to 120.0 S 22.0 46.000 0.0 SPG 220.84 0.0158 0.0 48.000 0.759 Vel = 5.57 SPG 0.0 4.1 E 14.534 300.000 42.829 to 140.0 G 2.907 46.508 0.0 HYD 220.84 0.0109 T 29.067 346.508 3.774 Vel = 5.37 HYD 100.00 4.1 0.0 1.000 46.603 Qa= 100 to 140.0 0.0 0.0 0.0 CITY 320.84 0.0220 0.0 1.000 0.022 Vel = 7.80 0.0 320.84 46.625 K Factor= 46.99 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087