HomeMy WebLinkAboutSeptic info ��
I • - -
s ,#. a •,
�
To: Orono residents on mound type septic systerns
From: Wiliie Gibbs, ISTS Manager
Date: May 10,2006
Reti Landscaping Do's and Don'ts for Mound Systems, Quick Reminder
Do plant and maintain a full cover of grass and keep mowed to a normal height, this grass cover aids
in the evaporation of large amounts of effluent(the fiquid left after the "othe�' stuff has been removed)
in the summer time and allows the mound system to help breakdown nitrogen in the effluent.
Do water the grass over the mound in extreme dry conditions, sparingly.
Do avoid unnecessary foot traffic over the mound, mow it and stay off of it. This is especially true in the
winter time. Even human foot traffic can cause frost to penetcate the mound resulting in potential
freezing problems.
D� inspect your mound system annually for winter kill, (reseed if necessary) animal damage,
(burrowing)or signs of potential failure.
Do not plant trees or shrubs on the mound system, smaller trees and shrubs may be planted at the
edges. Remember,that sunshine is the key to a healthy mound system.
Do ask questions, if you have any concerns or questions concerning your mound system
please feel free to call me,I can be reached at 952-249�626.
1
�•
♦ , . ,
Y_ O�
O , O CI'TY OF ORONO
-$,� :.- . /
� s � � MunicipalOffices
r�,,' ,�`� �, Street Address Mailing Address:
�� G'�' 2750 Kelley Parkway �-.r.,� P.O. Box 66
�i Orono, MN` 55356 , . , � � Crystal Bay, MN 55323-0066
�kESH04 's.�"
• * a..�
To: The Current Owner of Address 2990 SUSSEX RD
City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a
periodic basis. The onsite sewage treatment system at the above address has been inspected and
the following is known about the system. A sketch of the known components of the system is
available for most properties at the Orono City Hall.
Imminent Public Health Threat
Yes �No
If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of
this notice. The septic system must be brought into compliance within 90 days. Failure to do so
will result in referral to the City Attorney for legal action.
System Identified as N -Compliant
Yes
No
If yes, system must be brought into compliance by:
December 31, 2007
December 31, 2010
Other
Septic Tank(s) Pump out Needed
Yes �No
The city recommends the septic tank(s) and/or lift tank be serviced and pumped out every three
(3) years. City records indicate the tank(s) were last pumped out on S- �S•a�
The tank(s) should be cleaned through the manl�ole and not through the inspection pipes, this
allows for proper cleaning.
Comments:
�
.,.� � 7
Inspector: �� Date of Inspection: � O
Telephone (952) 249-4600 • Fax (952) 249-4616
www.ci.orono.mn.us
� °�
0 0
�= � CITY o� ORONU
,,� ,�;�����r��- _ �.
�,r�, ;�°,�' `' - Fr Municipal Offices
� ti
-.y.
��, � �����:-�
� Street Address: °ISa.-a4q-y6o O
�
���'�`,�G Mailing Address:
\,�,9 .��}�.e;;r.�4 .
_ $,E$KQ � 2750 Kelley Parkway P.O. Box 66
�—� Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: {���i0 ��S[° x 1��
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMIT'Y (1-3): �
1 "CODE SYSTEM"An ISTS which meets all the]ocation,�sign and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standazds of the current Orono
Municipal Code but does meet the three foot sepazation requirement or two foot requirement for systems iastalled 1996 or earlier,and
which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may aot meet all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDTTION(5-71: �
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanlcs to be pumped out once every 3 years.
Tank was last pumped i D - 1�-�C ).
Make sure seutirtanks are pumaed throu¢h manhole and not throuQh white insnection pipes. This allows for the aroper
cleanin�. Keep water softner and iron filter discharse out of seutic svstem to nroiong life of drainfield. Ask aumner to test
alarm float to verifv alarm is still working in vour house. The alarm warns owner that septage is about to backua into basement
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDTTION(8-101: �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS:
�
� ' d� 1 ' � �
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other U�ansfer of properry, be advised.that this report does
not guazanteE or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current
�°� , .
o���::�= o
�:�.��:_,� CITY of ORONO
. � �� � ��� �
� +�• �;: l4 Municipal Offices
/ '�ir � h,
t ��1;������ G Street Address: Mailing Addreu:
9�C'E+gHOg'�/ 2150 Kelley Parkway P.O. Boz 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
9 9� s�ss� Rd�c�
T�Current�wner: Aldress: �
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be ittspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY 1-3 : �
1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the cunent Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standerds of the current Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent throat to public health or safety.
3 "NON-COMPLIANT SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or constructian standards of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-71:
Tank inspection indicates:
� Pumpout not needed at this time.
Septic tanks must be pumped out this yeaz (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped �0�\ —0 i ).
Make sure sentic tanks are�umaed throush manhole and not through white inspection uiues. This allows for the
proaer cleaninQ. Keep water softner and iron flter dischar¢e out of seutic svstem.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out nova.
INFIELD CONDITION 8-10 : �
Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing, not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: I� ��� 1 a a b , �� Sc � � ��lcs S�M�cr
��oy , o,� cA.r. cv� ;� ��.�;Q� , cS � r�,J �n v
��5a– cc.��w��� �—,pv�- �h�S ����. o� -
\o�--o� �a� �`vo�
Date of Inspection Matt Bolterman - Septic Systcm Inspector
Note: In the event that this inspection r�port is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this nport does not guarantee
or cerdfy that an existing system will continue to function properiy,but is merely an opinion of the adequacy of the system under currentconditioas bascd on the available
information.
Telephone(952)249-4600 • Fax(952)?A9-4616
www.d.orono.mn.us
� O� � [A �a--,..�
�`�� g t� � --�w.,.�f
O�<, O
�=���= CITY of ORONO
`*� "'�� _`.�`�'-.�' �
\�'' ��' �" Offices
,� �I�,���-��� G.�, i�tunicfpat
l ��` 4i Street Address:
�q,��`�J��g MailinQ Addreu:
2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: �O (� ��-'��C S b � �°1�� S vS S C R(>
Address:_ �
Cin�Ordinance 199 requires that each existing on-site se�vage treatment system in Orono be inspected every rivo years.
The on-site se�vage treatment rystem at the above address has been inspected and appears to fall into ihe ca[e;ories checked belo�v.
STEM CONF'OR��IITY 1-3 : �
1 °CODE SYSTEM�� An ISTS which maets a1l the location,design and construction standards ofthe current Orono�funicipal Code.
2 ��COI�fPLIANT SYSTEM° An ISTS which does not meet all the localion,desig�and construction standards opthz cunrnt Orono Municipal
Code but does meet the three foot sepazation requiremznt,aad which is not failing or an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS K•hich may
or may not meet all the locatior�dasign,or construction standard�oFtha currerrt Orono�funicipal Coda and which is failing for any reason;and
any ISTS with less than three feec of unsaturated soil or sand between the distribution device and tha limiting soil characceristics.
T.-�N`fC CONDITION(�-10):
Tank inspection indicates:
� Pumpout not needed at this time.
6 Tank must be pumped out this year (city code requires tartics to be pumped out avery 3 years. Tank w�s last pumped �-1 0"'� 75 �
� Solids accumulation in tanks is at a critical a critical levzl. Tanks shou(d ba pumpzd out as soon as possibte.
8 Systam is discharging to the surface. Tu�ks must be pumped out within 43 hours to aliminata surface discharge.
9 Inspection risers missing-tanks could not be inspected Inspection risen(4"dia.pipe)must be installed in each tank at ne;ct pumpout If tanks
ha�•e not bezn pumptd out withirt the Iast thtea ytars,they should ba pumped out now.
10 Inspzction pipz is located duectly over tanic baffle(does not give accurate maysurement of solids accumulation). If tanks have not bzen pumped
out within the last threa years,they should be pumpad out now.
i LD CONDITION 11-1=1 : �\
1 Draintiald u dry,no surfacing avidrnt
12 Some avidence of surfacing,not aitical yet
13 DrainField is saturatzd and visibly dischuging untreated effluent to tha surfue. Contact the City Irupector immediately.Repairs must ba
campletad wi[hitt 90 days.
1-� Draintield e�tent and condition unknown. '
CO��I�;TS: � S �� t Od1C.�j � �(� � �, r^n S .
�1�� � � ��
Date of Inspcction • Septic System Inspector '
Note: In tha tvent that this inspection report is used to satisfy the requiremznis for a moRgage or other transfrr of property,be advised that Uus repoR doa not guazantze
or certify that an e.�asting systerrt will continue to function proprrly,but is merely an opinion af the adequacy of the systrm undzr cucrrnt conditions bued on the available
informalioa
�
O�
O :,�,_ O
���:==��� � CITY of ORONO
� �;l �
,e��5�°�"��' ti Municipal Oft3ces
� �
r��.A���r��r G'�'
�� y,���-��,� � SVeet Addtess: MaiUn�Address:
�Hp'g' 2750 Kelley Pa�kway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: Address: 2990 Sussex Rd.
Permit #'s: 4546 Dates: 8/10/92 Contractors: Coppin Plbg.
(This is [� an existing system [ ] new construction) .
STEM COMPLIANCE (1-3) : 1
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level is [�] or is not [ ] identified under this septic system. If the
saturated soil level is not idefitified, this classification is subject to revision.)
NK CONDITION (5-9) : 5 .
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are [�] or are not [ ] water tight or the condition is [ ] unknown. If the tanks
are not confirmed to be watertight, this classification is subject to revision.)
INFIELD CONDITION (11-14) : 11
11 Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low
COMMENTS:
�f�8=�
Date of Inspection Se tic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone(612)2A9-4600 • Fax(612)249-4616
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWA(;E TREATbIENT
�ti.
INSPECTION REPORT
���k o4��
ESH
Owner•�f����Address• oC / !Q ,7/.�JCI'� /�.
Permit ,�'s: Dates:_ .�S Il%�—lo� Contractors: ( n/Y�lh �/ �
City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is f� an existing system [ ) new construction)
S1'STEM CONFORMITY 1-3 :
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the Location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic �has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identifi , this classification may be subject to revision.)
TANK CONDITION (5-10):
T inspectio� indicates:
5 Pumpout not needed at this time.
Solids accunulation in tanks indicates they should be puiped out this year to help prevent future problems.
7 Solids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible.
8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar$e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe> must be installed in each
tank at next pu�pout. If tanks have not been punped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been Exmped out within the last three years, they should be punped out now.
DRAINFIELD CONDITION (11-14):
Dr field inspection indicates:
�Drainfield is dry, no surfacing evident.
'tZ Sane evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City [nspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slooe.setbacks,etc.):
POTENTIAL FOR SYSTEM fAILURE (depends on soils,water table.etc.): ��
COMMENTS:
�
Date of Inspection p c Sy te nspector
Note: !n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properlyi but is merely an opim on of the adequacy of the system under current conditions based on the available
tnformation.
This report must be kept on the premises with the system locetion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner