System Status
System status on date(mmlddlyyyy): 2/8/2018
® Compliant-Certificate of Compliance ❑ Noncompliant- Notice of Noncompliance
(Valid for 3 years from report date, unless shorter time (See Upgrade Requirements on page 3)
frame outlined in Local Ordinance.)
Reason(s)for noncompliance(check all applicable)
❑ Impact on Public Health (Compliance Component #1)—Imminent threat to public health and safety
0 Other Compliance Conditions(Compliance Component#3)—Imminent threat to public health and safety
❑Tank Integrity(Compliance Component #2)—Failing to protect groundwater
0 Other Compliance Conditions(Compliance Component#3)—Failing to protect groundwater
❑ Soil Separation (Compliance Component #4)—Failing to protect groundwater
❑ Operating permit/monitoring plan requirements(Compliance Component #5)—Noncompliant
Property Information Parcel ID#or Sec/Twp/Range: 0611723240014
Property address: 350 North Arm Lane, Orono,MN Reason for inspection: ProperttTransfer
Property owner: Douglas Olson Owner's phone: 612-282-8620
or
Owner's representative: Representative phone:
Local regulatory authority: City of Orono Regulatory authority phone: 952-249-4600
Approximately 1-1300, 1-1000 gallon septic tanks,1-1300 gallon lift station and 630 square feet of
Brief system description: mound rockbed.
Comments or recommendations:
TBM: Bottom of rock bed. 1.3 feet of sand under the rock.
Certification
I hereby certify that all the necessary information has been gathered to determine the compliance status of this system, No
determination of future system performance has been nor can be made due to unknown conditions during system construction,
possible abuse of the system,inadequate maintenance, or future water usage.
Inspector name: Joseph J Olson Certification number: 1255
Business name: Rusty O son's Soil& Perc.Testing License number: 810
Inspector signature: Phone number: 763-498-8779
Necessary or Locally Required Attachments
® Soil boring logs 0 System/As-built drawing 0 Forms per local ordinance
0 Other information (list):
www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats
wq-wwists4-31 • 1/24/12 Page 1 of 3
Property address: 350 North Arm Lane, Orono, MN Inspector initials/Date: J. 0. 2/08/18
1. Impact on Public Health -Compliance component#1 of 5
Compliance criteria: Verification method(s):
...........
System discharge sewage to the ❑Yes ® No ® Searched for surface outlet
ground surface. ® Searched for seeping in yard/backup in home
System discharge sewage to drain tile ❑Yes ®No ❑ Excessive ponding in soil system/D-boxes
or surface waters. ElHomeowner testimony(See Comments/Explanation)
"Black soil"above soil dispersal system
System cause sewage backup into ❑Yes ®No
dwelling or establishment. ❑ System requires"emergency"pumping
0 Performed dye test
Any"yes"answer above indicates the system is ❑ Unable to verify(See Comments/Explanation)
an Imminent Threat to Public Health and Safety. 0 Other methods not listed (See Comments/Explanation)
Comments/Explanation:
2. Tank Integrity—Compliance component#2 of 5
Compliance criteria: Verification method(s):
System consists of a seepage pit, 0 Yes ®No 0 Probed tank(s)bottom
cesspool,drywell,or leaching pit. 0 Examined construction records
Seepage pits meeting 7080.2550 may be ❑ Examined Tank Integrity Form (Attach)
Compliant if allowed in local ordinance.
Observed liquid level below operating depth
Sewage tank(s)leak below their 0 Yes ®No
designed operating depth. ❑ Examined empty(pumped)tanks(s)
If yes,which sewage tank(s)leaks: ElProbed outside tank(s)for"black soil"
Any "yes"answer above indicates the ❑ Unable to verify(See Comments/Explanation)
system is Failing to Protect Groundwater. Other methods not listed(See Comments/Explanation)
Comments/Explanation:
Elmer J Peterson Company Pumped the tanks.
3. Other Compliance Conditions-Compliance component#3 of 5
a. Maintenance hole covers are damaged,cracked,unsecured,or appear to structurally unsound. ❑Yes* ®No 0 Unknown
b. Other issues(electrical hazards,etc.)to immediately and adversely impact public health or safety. 0 Yes* ®No 0 Unknown
*System is an imminent threat to public health and safety
Explain:
c. System is non-protective of ground water for other conditions as determined by inspector 0 Yes* ►s No
*System is failing to protect groundwater
Explain:
www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats
wq-wwists4-31 • 1/24/12 Page 2 of 3
Property address: 350 North Arm Lane, Orono,MN Inspector initials/Date: J. 0.2/08/18
4. Soil Separation —Compliance component#4 of 5
Date of installation: 12/15/93 ❑ Unknown Verification method(s):
ShorelandiWellhead protection/Food Beverage ku Yes ❑ No Soil observation does not expire. Previous soil
Lodging? observations by two independent parties are sufficient,
Compliance criteria: unless site conditions have been altered or local
requirements differ.
For systems built prior to April 1, 1996. and ❑Yes ❑ No
not located in Shoreland or Wellhead ® Conducted soil observation(s)(Attach boring logs)
Protection Area or not serving a food, ❑ Two previous verifications(Attach boring logs)
beverage or lodging establishment. ❑ Not applicable(Holding tank(s),no grainfield)
Drainfield has at least a two-foot vertical 0 Unable to verify(See Comments/Explanation)
separation distance from periodically
saturated soil or bedrock. 0 Other(See Comments/Explanation)
Non-performance systems built April 1, ®Yes 0 No Comments/Explanation:
1996, or later or for non-performance
systems located in Shoreland or Wellhead
Protection Areas or serving a food,
beverage, or lodging establishment:
Drainfield has a three-foot vertical
separation distance from periodically
saturated soil or bedrock.*
"Experimental", "Other; or "Performance" 0 Yes ❑ No Indicate depths of elevations
systems built under pre-2008 Rules; Type IV
or V systems built under 2008 Rules(7080. A. Bottom of distribution media 100.0
2350 or 7080.2400 (Advanced Inspector
License required) B. Periodically saturated soil/bedrock 101.6
Drainfield meets the designed vertical C. System separation 2.8
separation distance from periodically
saturated soil or bedrock.
D. Required compliance separation' 2.6
Any "no"answer above indicates the system is "May be reduced up to 15 percent if allowed by Local
Failing to Protect Groundwater. Ordinance.
5. Operating Permit and Nitrogen BMP*—Compliance component#5 of 5 ® Not applicable
Is the system operated under an Operating Permit? ❑Yes ❑ No If"yes",A below is required
Is the system required to employ a Nitrogen BMP? ❑Yes 0 No If"yes", B below is required
BMP=Best Management Practice(s)specified in the system design
if the answer to both questions is "no", this section does not need to be completed.
Compliance criteria
a. Operating Permit number:
Have the Operating Permit requirements been met? ❑Yes 1:3 No
b. Is thereguired nitrogen BMP in place and properly functioning? ❑Yes D No
Any "no"answer indicates Noncompliance.
Upgrade Requirements(Minn. Stat.§115.55)An imminent threat to public health and safety(ITPHS)must be upgraded,replaced,or its use
discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect
ground water,the system must be upgraded,replaced,or its use discontinued within the time required by local ordinance.If an existing system
is not failing as defined in law,and has at least two feet of design soil separation,then the system need not be upgraded.repaired,replaced,or
its use discontinued,notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas,
Wellhead Protection Areas, or those used in connection with food.beverage, and lodging establishments as defined in law.
www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats
wq-wwists4-31 • 1/24/12 Page 3 of 3
Tank Report
Date: January 30,2018
Elmer J.Peterson Co.
5921 Dague Ave.
Delano,MN 55328
Phone 763-972-2420
Fax 763-972-7217
MPCA License#219
Doug Olson
350 N.Arm Lane
Orono,MN 55356
612-282-8620
Baffles: ON OFF
Tank Capacity: 1-1300 Gallon Septic, 1-1000 Gallon Septic,1-1300 Gallon Lift Station
#of Tanks: 3
Type of Tanks: Concrete
Gallons Pumped: 2500
Manholes to Grade: YES / NO
Comments:
On January 30,2018,Elmer J.Peterson Co.uncovered manholes(1n—8 inches deep,2"and lift station
to grade)and pumped septic tanks. No cracks or water leaking in tanks at that time.
NOTE:This is only a tank report. This is not a compliance inspection for point of sale nor does it
replace a compliance inspection.
Property address: 350 N.Arm Lane Inspector initials/Date: 1/30/18
1. Impact on Public Health-Compliance component#1 of 5
Compliance criteria: Verification method(s):
System discharge sewage to the 0 Yes 0 No 0 Searched for surface outlet
ground surface. 0 Searched for seeping in yard/backup in home
0 Excessive ponding in soil system/D-boxes
System discharge sewage to drain tile 0 Yes 0 No
0 Homeowner testimony(See Comments/Explanation)
or surface waters. y C )
System cause sewage backup into ❑Yes 0 No 0 'Black soil"above soil dispersal system
dwelling or establishment. ❑ System requires"emergency"pumping
❑ Performed dye test
Any"yes"answer above indicates the system is ❑ Unable to verify(See Comments/Explanation)
an Imminent Threat to Public Health and Safety.
0 Other methods not listed(See Comments/Explanation)
Comments/Explanation:
2. Tank Integrity-Compliance component#2 of 5
Compliance criteria: Verification method(s):
System consists of a seepage pit, ❑Yes ®No ❑ Probed tank(s)bottom
cesspool,drywall,or leaching pit.
0 Examined construction records
Seepage pits meeting 7080.2550 may be ❑ Examined Tank Integrity Form(Attach)
compliant Hallowed in local ordinance.
Sewage tank(s)leak below their ❑Yes ®No 0 Observed liquid level below operating depth
designed operating depth. ® Examined empty(pumped)tanks(s)
If yes,which sewage tank(s)leaks:
0 Probed outside tank(s)for'black soil"
— ❑ Unable to verify(See Comments/Explanation)
Any"yes"answer above indicates the ❑Other methods not listed(See Comments/Explanation)
system is Failing to Protect Groundwater.
Comments/Explanation:
On 1/30/18,Elmer J.Peterson Co.pumped tanks.
3. Other Compliance Conditions-Compliance component#3 of 5
a. Maintenance hole covers are damaged,cracked;unsecured,or appear to structurally unsound. 0 Yes` 0 No 0 Unknown
b. Other Issues(eledncai hazards,etc.)to immediately and adversely impact public health or safety 0 Yes' ❑No U Unknown
`System is an imminent threat to public health and safety
Explain:
c. System is non-protective of ground water for other conditions as determined by inspector 0 Yes* ❑No
'System is failing to protect groundwater
Explain:
www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800.657-3864 • Available in alternative formats
wq-wwlsts4.31 • 1/24/12 Page 2 of 3
Soil Observation Log
>WW.SepticRcsource.com vers 12.4
Owner Information
Property Owner/project: Douglas Olson Date 2/8/2018
Property Address/PID: 350 North Arm Lane
Soil Survey Information ❑refer to attached soil survey
Parent matl's: LI Till LI Outwash ❑ Lacustrine ❑ Alluvium ❑ Organic L] Bedrock
landscape position: LI Summit ❑ Shoulder ❑Side slope ❑Toe slope
soil survey map units: L41 C2 slope % direction- Lineal
Soil Log#1
LI Boring ❑ Pit Elevation 100.5 Depth to SHWT 38 inches
Depth(in) Texture fragment% matrix color redox color consistence grade shape
loose loose single grain
friable weak granular blocky
0-20 Fill <35 . firm moderate prismatic platy
rigid strong massive
20-28 Topsoil <35 10yr311 Loose Loose Single grain
28-32 Clay Loam <35 10yr4/3 Friable Strong Blocky
32-38 Clay Loam <35 10yr5i4 Friable Strong Blocks
38-46 Clay Loam <35 IOyrS'4 10y4l8.1-6i10y Firm Strong Blocky
Comments:
350 North Arm Lane Soil Log#2
❑� Boring ❑ Pit Elevation 100.5 Depth to SHWT 40 inches
Depth(in) Texture fragment% matrix color redox color consistence grade shape
loose loose single grain
friable weak granular blocky
��
0 Fill <35
firm moderate prisinatic platy
rigid strong massive
22-36 Topsoil <35 I0yr3/l Loose Loose Single grain
36-41) Clay Loam <35 10yr4/3 Friable Strong biuclk>
40-f-I Clay Loam --35 2.5y5!3 10y4;8,]-6/10y Firm Strong Blocky
<35 loose loose single grain
friable weak granular blocky
35-50
firm moderate prismatic platy
>50
rigid strong massive
350 North Arm Lane Soil Log#3
Ei Boring ❑ Pit Elevation Depth to SHWT
Depth(in) Texture fragment% matrix color redox color consistence grade shape
<35 loose loose single grain
friable weak granular blocky
35-50
firm rm moderate prismatic platy
rigid strong massive
loose loose
<35single grain
friable weak granular blocky
35-50
>50 firm moderate prismatic platy
rigid strong massive
loose loose
<35 single grain
friable weak granular blocky
35 -50
firm moderate prismatic platy
>50massive
rigid strong
<35
loose loose single grain
friable weak granular blocky
35 -50
50 firm moderate prismatic platy
rigid strong massite
loose loose
<35 single grain
friable weak granular blocky
35 -50
firm moderate prismatic plat
>50
rigid strong massive
I hereby certifi'this work was completed in accordance with MN 7080 and any local reqs.
Rusty Olson's Soil & Perc 810
Designer Signature Company License#
/ I
C -. /
w 1 / __Y .----
—
w ,
v, a r)Eili
1
1 V 6
M-4 .___ Li\
C>i
`j • i/ _ / ,_.._ __`
—a -;%, -& - / ,, /
_ _. / c,__,_ ,
I
1 l
I
+r