Loading...
HomeMy WebLinkAbout07/03/18 Septic Compliance Inspection SP TESTING INC. Steven B.Schirmers —951 Katydid Lane NE—St. Michael, MN 55376 Cert. No 627 — State License#394 — Phone 763-497-3566 — Fax 763-497-5011 www.sptestinzwastewater@comcast.net— schirmerswastewater.com July 11, 2018 Robert Innes 4720 North Arm Dr. Orono, MN A Compliance inspection was completed for the existing on-site sewage treatment system located on this property for the sale of the home. The system consists of 2-1000 gallon septic tanks, 1-1000 gallon pump tank & a pressurized mound system with a 10' x 51' rock bed, built in 1990 for a 4 bedroom home. Soil boring #1A found mottled soil (redox features) at 1.7' into the original soil & the original soil at elev. 92.7 & the bottom of the rock bed at elev. 93.6 leaving .9' of sand below the rock bed & a 2.6' separation from the bottom of the rock & redox features. Soil boring #2A found mottled soil at 1.3' into the original soil & the original soil at elev. 91.8 & the bottom of the rock bed at elev. 93.3 leaving 1.5' of sand & a 2,8" separation. This system meets the required 3' separation from the bottom of the trenches & redox features & is classified as in compliance with Minnesota Chapter 7080 rules. The tanks were pumped by Kothrade Sewer , Water & Excavating & were found to be compliant. Nothing other than gray water (laundry, showers etc.) human waste & toilet tissue should be disposed of into the septic tanks. Garbage disposals are not recommended due to adding more solids & fine solids passing through into the system. iron filters are also not recommended & should be diverted out of the system. Excessive amounts of soaps, antibacterial soaps, cleaning agents, shower cleaners used every shower & chlorine agents may kill the bacteria you need living in the system. Additives are not recommended. Recommend to pump & clean you tanks through the manhole by a certified pumper every 2 years. Check with your pumper to set up a schedule. This certificate of compliance is no guarantee that this system will continue to function indefinitely. Steven B. Schirmers S-P TESTING, INCa Steven B. Schirmers • MPCA Cert.No. 627 951 Katydid Lane NE • St. Michael, MN 55376 • (763) 497-3566 FAX (763) 497-5011 State License #394 wwwsptesting.wastewater@comcast.net- sehirmerswastewater.com v.oci " \I-1,..\ \-1 .?-,..c.) t--10. 14¢ts. Q-• 01-ci s) M.LLIAfi ,L"...0 ScN.,r•6 '. .L"7'yo ..._. 65. rk,S/:::--- ii -11 " 144 K414\: \a qM v ..- .,..-4A---) 4,.. -Mc,•v w : F raF.- S .� ,6 a* !-i 'I c M"2u)..� 'v-44..1.4 4c C, `5.2 *14 ' 3 IC 9 . / 9 s� ,� o, ‘.L i _c'` 3. 11-Y3 w r.`' _f,fi' cc 0a e1., ,t 1,,/ - 1ct3 1.p' ,,4a.-\t7 la 0 rj •1' ,,ev " td.-rl ti: ,,J 1T,.4- c J.- _5T,,''it_- 'Pi i c7Ge+1a , Sa% 33.3. 91.S R'S-'A - 9 .a ,�.�.s,AL. I ,.,10 if'%^/1,..J 3, 1 ,Q .- 4a a?-'s,.7 y: ,`_ 4. 4 � _w�4c7 - s '...a •.,., •S� ,i414_-,,, s. `, ��,� ,�jo y,Y 1,3 C�\a•��,ai L. —70.4(s op, ,,,c.. , .,„,� 91 43 p...r..o 4J<, c4 c-5'1•? / s 14e /.a 11 , hou;c, / j / 26 / / IC' ‘,I { • • . Minnesota Pollution Corn p ince Inspection Fernvos, Control Agency 520 Lafayette Road North Existing Subsurface Sewage Treatment Systems St.Paul,MN 55155-4194 (SSTS) Doc Type:Compliance end Enforcement Instructions: Inspection results based on Minnesota Pollution Control Agency(MPCA) For local tracking purposes: requirements and attached forms-additional local requirements may also apply. Submit completed form to Local Unit of Government(LUG)and system owner within 15 days System Status System status on date(mmlddlyyyy): `'1-~-1` tri Compliant—Certificate of Compliance ❑ Noncompliant—Notice of Noncompliance (Valid for 3 years from report date,unless shorter time (See Upgrade Requirements on page 3) frame outlined in Local Ordinance.) Reason(s)for noncompliance(check all applicable) ❑ Impact on Public Health(Compliance Component #1)-Imminent threat to public health and safety ❑ Other Compliance Conditions(Compliance Component#3)-Imminent threat to public health and safety ❑Tank Integrity(Compliance Component #2)-Falling to protect groundwater Other Compliance Conditions(Compliance Component#3)-Failing to protect groundwater ❑Soil Separation(Compliance Component #4)-Failing to protect groundwater ❑Operating permit/monitoring plan requirements(Compliance Component #5)-Noncompliant Property Information Parcel ID#or Sec/Twp/Range: y , Property address: Lir'? CI 0 h40C,(''\ A o `. , Reason for inspection: ,cr /4 Property owner: Owner's phone: (,tip- - �c� or Owner's representative: Representative phone: Local regulatory authority: c.t-C-( 04 1,7“ Regulatory authority phone: 95; - y q _ 4 b fl o Brief system description: - a.I epeAFK,cP vq- /00 o _tV�1--% 441-Y4- ed MuComments or recommendations: ✓} Fgfi= Pow � t-s�,�.,��. Certification I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system,inadequate maintenance, or future water usage. Inspector name: 5-f�y LA‘1.-1,,A4:10 -„,. Certification number: Business name: -� � IP, License number: Inspector signature: .-.4.111,77._., Phone number: ita - '"l - 5i,to Necessary or Locally Required Attachments 153 Soil boring logs IN System/As-built drawing 0 Forms per local ordinance ❑Other information(list): www.pca.state.mn,us 651.296.6300 0 800-657-3864 o TfY 651.282.5332 or 800-657-3864 . Available in alternative formats wq-wwlsts4-31 • 1124/12 • • Property address: Inspector Initials/Date: 1. Impact on Public Health—Compliance component#1 of 5 Com•fiance criteria: Verification method(e): System discharge sewage to the ❑Yes 13 tido 0 Searched for surface outlet ...round surface. In Searched for seeping in yard/backup in home System discharge sewage to drain the ❑Yes t3 No ® Exoesalve ponding in soil systerNp-boxes or surface waters. 0 Homeowner testimony(See Comments/Explanation) System cause sewage bacwp into ❑ye6 ❑ -Black soil above soil dispersal system dwelling or establishment. ®No ❑ System requires"emergency"pumping ❑ Performed dye test Any"yes"answer above Indicates the system Is 0 Unable to verify(See CommentsWExpienation) an Imminent Threat to Public Health and Safety. 0 Other methods not listed(See Commenta/Explenation) Comments/Explanation: • • 2. Tank Integrity—Compliance component#2 of 5 • Compliance criteria: Verification method(s): System consists of a seepage pit, 0 Yes 0 No 0 Probed tank(s)bottom cesspool,drywall,or leading pit. 0 Examined construction records Seepage pits meeting 7080.2550 may be 0 Examined Tank Integrity Form(Attach) compliant if allowed in local ordinance. Sewage tank(s)leak below their 0 Observed liquid level below operating depth designed operating depth. ❑Yes 0 No 0 Examined empty(pumped)tanks(s) If yes,which sewage tank(s)leaks: 0 Probed outside tanks)for"black soir Any"yea"answer above In•r`ccates the 0 Unable to verify(See Comments• +Ekplanatiar) system Is Falling to Protect Groundwater. ID Other methods not listed(See Comments/Explanation) Comments/Explanation: • c,e-td kr' "7 'i'' ol's- ` ' • 3. Other Compliance Conditions—Compliance component#3 of 5 a. Maintenance hole covers are damaged,cracked,unsecured,Cr appear to structurally unsound. ❑Yes• IN No El Unknown b. Other issues(elect♦lbai hazards,etc.)to immediately and adversely impact public health or safety. ❑Yes' as No ❑Unknown `System is an imminent threat to public health and safety Explain: • c. System is non-protective of ground water for other conditions as determined by inspector ❑Yes` ( No 'System Is falling to protect groundwater Explain: • wolm ca,state.mrt.us a 651.296-630(1 657.3864 a TTY 651.282.5332 or 800.657-3864 6 Available in alternative formats wa-wwtsts4-31 • 1/24112 Property address: v °-A0C—s:11 '4)Evv1 _, Inspector initials/Date: 4. Soil Separation—Compliance component#4 of 5 Date of installation: I ""`, 0 0 Unknown Verification method(s): Shhorenandlwellhead protectIONFoodBeverage ❑Yes D No Soil observation does not expire.Previous soil d s e observations by two independent parties am sufficient, Compliance criteria: unless site conditions have been altered or local For systems builtprior to ®Yes 0 No requirements differ. y April 1, 1996,and not located in Shoreland or Wellhead ® Conducted soil observation(s)(Attach boring logs) Protection Area or not serving a food, ❑ Two previous verifications(Attach boring logs) beverage or lodging establishment: ❑ Not applicable(Holding tank(s),no drafnfieid) Drainfield has at least a two-foot vertical 0 Unable to verify(See Comments/Explanetion) separation distance from periodically saturated soil or bedrock. ❑ Other(See Comments/Explanation) Non-performance systems built April 1, 0 Yes ❑ No Comments/Explanation: 1998,or later or for non-performance systems located In Shoreland or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock." "Experimental" `Other" or "Performance' 0 Yes 0 No indicate depths of elevations systems built under pre-2006 Rules;Type IV q u �, or V systems built under 2008 Rules(7080. A. Bottom of distribution media s; a 1. ,c>1;1„•7, ,,5 v,,,.,k, 2350 or 7080.2400 (Advanced inspector 5s } License required) B. Periodically saturated solUbedrock 5 2 1 .3 Drainfield meets the designed vertical 5e,14 2,81 , separation distance from periodically C. System separation saturated soil or bedrock. D. Required compliance separation" Any"no"answer above indicates the system is *May be reduced up to 15 percent if allowed by Local Failing to Protect Groundwater. Ordinance, 5. Operating Permit and Nitrogen BMP*—Compliance component#5 of 5 El Not applicable Is the system operated under an Operating Permit? ❑Yes El No If"yes",A below Is required Is the system required to employ a Nitrogen BMP? ❑Yes 0 No If"yes",B below is required BMP=Best Management Practices)specified in the system design If the answer to both questions is"no", this section does not need to be completed. Compliance criteria a. Operating Permit number: Have the Operating Permit requirements been met? El Yes ❑ No b. Is the required nitrogen BMP in place and property functioning? 0 Yes 0 No Any"no"answer indicates Noncompliance. Upgrade Requirementas(Minn.Stat.§115.55)An imminent threat to public health and safely(ITPHS)must be upgraded,replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance.if the system is failing to protect ground water,the system must be upgraded,replaced,or Its use discontinued within the time required by local ordinance.if an existing system Is not failing as defined in law,and has at least two feet of design soil separation,then the system need not be upgraded,repaired,replaced,or its use discontinued,notwithstanding any local ordinance that is more strict This provision does not apply to systems In shoreland areas, Wellhead Protection Areas,or those used in connection with food,beverage,end lodging establishments as defined in law. www.pca,state.mn.us o 651.296.6300 a 800-657-3864 TTY 651.282.5332 or 800-657.3864 Available in alternative formats SP TESTING INC. Steven B.Schirmers —951 Katydid Lane NE—St. Michael,MN 55376 Cert.No 627 — State License#394 — Phone 763-497-3566 — Fax 763-497-5011 www.sptestinzwastewater@comcast.net— schirmerswastewater.com SOIL BORING PROFILE Robert Innes 4720 North Arm Dr. Orono, Mn Soil borings completed with a bucket auger on 7-3-2018 SOIL BORING #1A - ELEV. 95.2- MOTTLED SOIL PRESENT AT 1.7' into the original soil - NO STANDING WATER PRESENT IN THE BORING. 0 - 12" Fill soil loam 12" - 30" Fill soil medium sand 30" - 50" Original soil Very dark brown loam 10YR 3/1 50" - 56" Pale brown clay loam 10YR 6/3 - distinct mottles 10YR 6/8 SOIL BORING #2A - ELEV. 94.8 - MOTTLED SOIL PRESENT AT 1.3' into the original soil. - NO STANDING WATER PRESENT IN THE BORING. 0 - 12" Fill soil loam 12" - 36" Fill soil medium sand 36" - 44" Original soil Dark brown loam 10YR 3/2 44" - 52" Brown clay loam 10YR 4/3 52" - 56" Brown clay loam 10YR 5/3 - distinct mottles 10YR 6/8 4720 North Arm Dr,Orono Mn 55364 Property address: Robbert Innes Inspector initials/Date: LB 618 1. Impact on Public Health-Compliance component#1 of 5 Com•fiance criteria: Verification method(s): System discharge sewage to the Yes ❑No 0 Searched for surface outlet round surface. ❑ Searched for seeping in P 9 yard/backup in home System discharge sewage to drain tide 0 Yes 0 No ❑ Excessive ponding in soil systemiD•boxes or surface waters. 0 Homeowner testimony(See Comment s/Explanation) System cause sewage backup into 0 Yes 0 No ❑ 'Black soil'above soil dispersal system dwelling or establishment. ❑ System requires"emergency'pumping Any"yes"answer above Indicates the system Is ❑ Performed dye test ❑ Unable to verify(See Commentsgxptanatian) an Imminent Threat to Public Health and Safety. 0 Other methods not listed(See Comments/Explanation) Comments/Explanation: 2. Tank Integrity-Compliance component#2 of 5 Corn'fiance criteria: Verification method(s): System consists of a seepage pit, 0 Yes ,lo ❑ Probed tank(s)bottom cesspool,drywall,or leaching pit. ❑ Examined construction records Seepage pits meeting 7080.2550 may be com..': t d allowed in local ordinance. ❑ Examined Tank Integrity Form(Attach) Sewage tank(s)leak below their 0 Observed liquid level below operating depth des!.ned o••>ratin. de.th. Yes Flo ® Examined empty(pumped)tanks(s) If yes,which sewage tank(s)leaks: /� ❑ Probed outside tank(s)for'blade soil' Unable to verify(See commenls/Exprenarion) Any"yes"answer above indicates the Other methods not fisted(See Comments/Explanation) system is Failing to Protect Groundwater. Comments/Explanation: Compliant per 7080 Code: 0/ No Notes: ,3-/0o 9a!(e,„ -/z„/r 4" r F rt' )w o ` 4,dc S art /eJ.e, b Business Name: Kothrade Sewer,Water,Excavating,Inc 4 �r+ (11^4c4; �� 1 p{ Business Address: 12059 Whitetail Ln,Hanover MN 55341 • N� C 6S•Prv� Business Phone: 763.498.8702 Company Representative: Lary Bursch MPCA#: 0192/9199 Signature 3. Other Compliance Conditions-Compliance component#3 of 5 a. Maintenance hole covers are damaged,cracked,unsecured,or appear to structurally unsound. 0 Yes' 0 No ❑Unknown b. Other issues(electrical hazards etc.)to immediately and adversely impact public health or safety. ❑Yes* 0 No 0 Unknown "System is an Imminent threat to public health and safety Explain: c. System is non-protective of ground water for other conditions as determined by inspector 0 Yes* ❑No 'System Is failing to protect groundwater w+yw.ixa.state.mn.us • 651-296-6300 • 800.657-3864 • we-wwlsts4-31 • 1/24/12 TTS'651.282-5332 or 800-657-3864 • Available In alternative formats Page 2 of 4