HomeMy WebLinkAbout2005-P08849 - mechanical � � PERMIT
CITY C)F ORONO
2750 Kelley Parkway- PO Box 66 Permit Number: p08849
Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits
(952)249-4600 Date Issued:
6/16/2005
SITE ADDRESS: 2175 Shevlin Dr Unit#
Wayzata,MN 55391
P��� 03-117-23-34-0007
DESCRIPTION:
Proposed Use: Residenrial
Pernut Class: General
Permit Type:
Mechanical Perxnits Permit Sub-type(s): Multiple Mechanical Items
DETAILS:
Approved per resolution#:
Separate permits required:
NOTICES/REMARKS:
FEE SUMMARY: Permit Fee: $ 120.25 valuation: $ 9,620.00
State Surcharge Fee: $ 4.81
Misc.Fee: $ 1.50
TOTAL FEE: $ 126.56
APPLICANT: Total Comfort OWNER: James&Amy Lloyd
12800 Highway 55 2175 Shevlin Dr
Plymouth,MN 55447 Wayzata,MN 55391
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED
AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF
MINNESOTA BUILDING CODE REQUIREMENTS.
�
`/�r l,GI.CJL � C�'�►t�i'l
APPLICANT PERMITEE SIGNATURE I UED BY SIGNANRE
Copies: 1-File(SignaturesRequired), 1-Applicant, 1-Monthly Reports, 1-Assessing,(If Septic, 1-Septic) Page 1
�a6.�
,
, �.
�
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT
Box 66 (2750 Kelley Parkway)
Crystal Bay, MN 55323
GENERAL INFORMATION
1. You may apply for mechanical permits by mail or in person at the City offices. Applications
will be reviewed and a permit will be issued within two working days.
2. Permit cards will be sent by return mail after a review is completed.PERMITS ARE NOT
VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE
PERMIT CARD IS POSTED ON THE JOB STTE.
3. Mechanical Designs- Complete calculations, aetails and specifications are required for each
heating,ventilation,humidification-dehumidificarion, and air conditioning installation
including heat loss/heat gain calculation, design temperatures,equipment ratings and
identification as to type,manufacturer and model.Data shall be presented on form provided.
Identification of and specifications for water heating equipment shall also be provided.
4. When any new construction or remodeling is involved, a separate building permit must be
obtained.
5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code
requirements.
6. All work must be inspected(rough-in and final). Call (952)249-4600. 24-hour norice
required.
7. House Heating Test Record must be submitted before final.
Instructions
Complete all items on this application. Compute the permit fee. Sign and date the
certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you
have questions, call (952) 249-4600.
Please check one: New Addition Repair �( Replace
Residential Commercial � �
� � �
JOB SITE: 1 � Zip:
Owner's Name: L `� � _ Phone Number: l,j - �'/ �
Mailing Address: Q/ City: ,(c,�'t��/'?O Zip:
..�, 76 3-�� � �..�
Contractor's Name: /' ' Phone Number:
Mailing Address: �'' City: �' ) % Zip: -
•' �
,
!
SYSTEM DESCRIPTION �
HEATIriG SYSTEMS
Quantit5': �_
Make: `�;�
ModeL• �-•---��� /
���� q�
Fuel: _���,
Flue Size:
Tnput BT'CTs: �
Output BTUs: 4 ll
CFM:
COOLING SYSTEMS�-
Quantity.
Make:
Model: / �
Tons: �t�n
H.Power
FIREPLACES
Gas factory fireplace
Wood burning factory fireplace with flue
Wood Stove
Wood stove with flue
Brand Name Model No.
VENTILATION
No. Kitchen Exhaust duct recalculating cfm
No. Bath Exhaust(must have duct outside) cfm
No. Other Fans: Locations cfm
FUEL STORAGE(MUST BE APPROVED BY FIRE MARSHAL)
Installation or Removal
Fuel oil: gallons underground inside or. outside
LP Gas: gallons
Other Gas opening
,
. .
. �
PERMIT FEE CALCULAT�ON(S)
2002 State Statute �Yes This Section Applies
The replacement of a Residenpal fixture or auvliance that meets all three of the following
requirements:
1) Does not require modification to electrical or gas service.
2) Has a total co of$500.00 or less;excluding the cost of the fixture or appliance:
and
3) Is improved,installed or replaced by the homeowner or licensed contractor.
Skip next section; Cost of Permit $ 15.00
State Surcharge $ .50
� Mail-In Fee $ 1.50
If above does not apply,follovV guidelines below:
1. Contract Price*is .0125%of job with a Minimnm Fee of fS35.001
�D�X.olzs $ o
(contract price) (minimum 35.00)
2. State Surcharee.**Add the State Building Code Division a Minimum Fee of($.501
A��.O v x.0005 $ / 0 /
(contract price) (minimum$.50)
3. Postage and Handlin¢(Only mail-in applications) $ 1.50
4.TOTAL PERNIIT FEE(Alid lines 1-3 above) $ / r �J
'CONTRACT PRICE or JOB COST means the actuai or estimated dollar amount charged for the permitted work
including materials,labor,pmfit,and other fixed costs.It is the amouut to be cLarged to the customer for the work
done.If any material,equipment,labor,or installation is furnished by the owner,tenant or any other party the
reasonable market value of such items must be added to the estimated cost or conttact price for permit fee puiposes.In
the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of
the actual contcact. �
�
s»Tye STATE SURCHARGE is.00�5 of the contraci price under$1,000,000 or$.50-whichever is greater.For
valuations over 51,000,000 call the D�partment of Inspectional Services for the price.
The undecsigned hereby applies to th8 City for issuance of a Mechanical Permit,agrees to do all work in strict
accordance with the ordinaaces of the City and the regulations of the Minnesota State Building Code,and ' es that
ail sratements made on this appli 'on are complete,true and cornct ^
� �/ 0
Applicant's Signature: �� Date:
Approved By: Date:
� I
�
�
,
AMY LLOYD
HV�#C LOAD ANALYSIS
for
�
Amy Lloyd
9 2175 Shevlin Dr
Wayzata, MN 55391
f
lit� oftwarQ
R���� Residential and Light
Commercial HVAC loads
Prepared By:
I Steve Hawes
TOTAL Comfort
12800 Hwy 55
Plymouth,MN 55441
763-383-8383
08-19-2004
1
� RHVAC-Residential&Light Commercial HVAC Lo ds Program * Elite Software Development,Inc.
A-ABC Appliance&Heating Amy Lloyd
� Minrleapolis,MN 55408 08-19-2004 Page 2
Project Summary
Design Data
Project Name: Amy Lloyd
Reference City: Minneapolis, Minnesota
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 Feet
Outdoor Outdoor Indoor Indoor Grains
Drv Bulb Wet Bulb Rel.Hum. Drv Bulb Difference
Winter: -10 N/A N/A 72 N/A
Summer: 90 73 I 50% 75 32
Check Figures
Total Building Supply CFM: 957 CFM per square foot: 0.251
Square feet of room area: 3,816 Square feet per ton: 1,604.778
Building Loads
Total heating required with outside air: 73,714 Btuh 73.714 MBH
Total sensible gain: 17,938 Btuh 73 %
Total latent gain: 6,563 Btuh 27 %
Total cooling required with outside air: 24,501 Btuh 2.042 Tons (based on sensible + latent)
2.378 Tons (based on 77% sensible capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
�
♦
' RHVAC-Residential&Light Commercial HVAC L ds Program � � Elite Software Development,Inc.
A-ABC Appliance&Heating � Amy Lloyd
, Minneapolis,MN 55408 08-19-2004 Page 3
Total Building Summary Loads
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
3A Window Double Pane Clear Gla�s Wood Frame 313 14,141 0 6,506 6,506
8M Glass Door pouble Clear Glass V1/ood Frame 42 1,898 0 1,164 1,164
11 F Door Metal Urethane Core & Storm � 21 293 0 66 66
12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 1,364 6,712 0 1,522 1,522
15C Wall 2-5' Below Grade 8/12" BIk+R-11 1,270 5,311 0 0 0
161 Ceiling R-44 Insulation 2,304 4,346 0 2,067 2,067
19J Floor Over Encl Crawl Carpet+ R-30 792 1,136 0 0 0
21A Basemt Floor 2'or More Below Grade 1,512 2,976 0 0 0
Subtotals for structure: 7,618 36,813 0 11,325 11,325
Active People: 7 0 1,610 2,100 3,710
Inactive People: 2 0 300 500 800
Appliances: '; 0 0 0 0 0
Lighting: 0 0 0
Ducfinrork: 0 3,070 0 478 478
Infiltration: Winter CFM: 375.1, Summer CFM: 214.3 376 33,831 4,653 3,535 8,188
Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0
Sensible Gain Total: 17,938
Temperature Swing Multiplier: X1.00
Building Load Totals: 73,714 6,563 17,938 24,501
Check Figures
Total Building Supply CFM: 957 CFM per square foot: 0.251
Square feet of room area: 3,816 Square feet per ton: 1,604.778
i
Building Loads
Total heating required with outside air: 73,714 Btuh 73.714 MBH
Total sensible gain: 17,938 Btuh 73 %
Total latent gain: 6,563 Btuh 27 %
Total cooling required with outside air: 24,501 Btuh 2.042 Tons (based on sensible + latent)
2.378 Tons (based on 77% sensible capacity)
;
Notes I
Calculations are based on 7th edition of A�CA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
.
' RHVAC-Residentlal&Light Commerciai HVAC L ds Program -' � Ellte Software Development,Inc.
A-ABC Appliance 8�Heating , Amy Lloyd
�
Minneapolis,MN 55408 08-19-2004 Page 4
System#1 Summary Loads
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
3A Window Double Pane Clear Glasls Wood Frame 313 14,141 0 6,506 6,506
8M Glass Door pouble Clear Glass UNood Frame 42 1,898 0 1,164 1,164
11 F Door Metal Urethane Core & Sto►tn 21 293 0 66 66
12H Wall R-19 + 1/2" Gypsum Board(P2-0.5) 1,364 6,712 0 1,522 1,522
15C Wall 2-5' Below Grade 8/12" BIk+R-11 1,270 5,311 0 0 0
161 Ceiling R-44 Insulation 2,304 4,346 0 2,067 2,067
19J Floor Over Encl Crawl Carpet+ Rr30 792 1,136 0 0 0
21A Basemt Floor 2'or More Below Griade 1,512 2,976 0 0 0
Subtotals for structure: 7,618 36,813 0 11,325 11,325
Active People: 7 0 1,610 2,100 3,710
Inactive People: 2 0 300 500 800
Appliances: j 0 0 0 0 0
Lighting: 0 0 0
Ducfinrork: 0 3,070 0 478 478
Infiltration: Winter CFM: 375.1, Summer dFM: 214.3 376 33,831 4,653 3,535 8,188
Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0
Sensible Gain Total: 17,938
Temperature Swing Multiplier: X1.00
System Load Totals: 73,714 6,563 17,938 24,501
Check Figures
Supply CFM: 957 CFM per square foot: 0.251
Square feet of room area: 3,816 Square feet per ton: 1,604.778
System Loads
Total heating required with outside air: 73,714 Btuh 73.714 MBH
Total sensible gain: 17,938 Btuh 73 %
Total latent gain: 6,563 Btuh 27 %
Total cooling required with outside air: 24,501 Btuh 2.042 Tons (based on sensible + latent)
2.378 Tons (based on 77% sensible capacity)
i
Notes I
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads. �
' RHVAC-Fkesidentfal&Light Commercial HVAC Lo�ds Program =� � Elite Software Development,Inc.
A-ABC Appliance&Heating � � Amy Lloyd
.
Mirmeapolis,MN 55408 0&19-2004 Page 5
System#1 Zone#1 Summary Loads
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
3A Window Double Pane Clear Glass Wood Frame 313 14,141 0 6,506 6,506
8M Glass Door pouble Clear Glass Wood Frame 42 1,898 0 1,164 1,164
11 F Door Metal Urethane Core & Storrii 21 293 0 66 66
12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 1,364 6,712 0 1,522 1,522
15C Wall 2-5' Below Grade 8/12" BIk+R-11 1,270 5,311 0 0 0
161 Ceiling R-44 Insulation 2,304 4,346 0 2,067 2,067
19J Floor Over Encl Crawl Carpet+ R-30 792 1,136 0 0 0
21A Basemt Floor 2' or More Below Grade 1,512 2,976 0 0 0
Subtotals for structure: 7,618 36,813 0 11,325 11,325
Active People: 7 0 1,610 2,100 3,710
Inactive People: 2 0 300 500 800
Appliances: 0 0 0 0 0
Lighting: 0 0 0
Ducfinrork: 0 3,070 0 478 478
Infiltration: Winter CFM: 375.1, Summer CF�M: 214.3 376 33,831 4,653 3,535 8,188
Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0
Sensible Gain TotaL• 17,938
Temperature Swing Multiplier: X1.00
Zone Load Totals: � 73,714 6,563 17,938 24,501
Check Figures
Supply CFM: 957 CFM per square foot: 0.251
Square feet of room area: 3,816 Square feet per ton: 1,604.778
Zone Loads
Total heating required with outside air: 73,714 Btuh 73.714 MBH
Total sensible gain: 17,938 Btuh 73 %
Total latent gain: 6,563 Btuh 27 °%
Total cooling required with outside air: 24,501 Btuh 2.042 Tons (based on sensible + latent)
2.378 Tons (based on 77% sensible capacity)