Loading...
HomeMy WebLinkAbout2005-P08849 - mechanical � � PERMIT CITY C)F ORONO 2750 Kelley Parkway- PO Box 66 Permit Number: p08849 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952)249-4600 Date Issued: 6/16/2005 SITE ADDRESS: 2175 Shevlin Dr Unit# Wayzata,MN 55391 P��� 03-117-23-34-0007 DESCRIPTION: Proposed Use: Residenrial Pernut Class: General Permit Type: Mechanical Perxnits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 120.25 valuation: $ 9,620.00 State Surcharge Fee: $ 4.81 Misc.Fee: $ 1.50 TOTAL FEE: $ 126.56 APPLICANT: Total Comfort OWNER: James&Amy Lloyd 12800 Highway 55 2175 Shevlin Dr Plymouth,MN 55447 Wayzata,MN 55391 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. � `/�r l,GI.CJL � C�'�►t�i'l APPLICANT PERMITEE SIGNATURE I UED BY SIGNANRE Copies: 1-File(SignaturesRequired), 1-Applicant, 1-Monthly Reports, 1-Assessing,(If Septic, 1-Septic) Page 1 �a6.� , , �. � CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed.PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB STTE. 3. Mechanical Designs- Complete calculations, aetails and specifications are required for each heating,ventilation,humidification-dehumidificarion, and air conditioning installation including heat loss/heat gain calculation, design temperatures,equipment ratings and identification as to type,manufacturer and model.Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call (952)249-4600. 24-hour norice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call (952) 249-4600. Please check one: New Addition Repair �( Replace Residential Commercial � � � � � JOB SITE: 1 � Zip: Owner's Name: L `� � _ Phone Number: l,j - �'/ � Mailing Address: Q/ City: ,(c,�'t��/'?O Zip: ..�, 76 3-�� � �..� Contractor's Name: /' ' Phone Number: Mailing Address: �'' City: �' ) % Zip: - •' � , ! SYSTEM DESCRIPTION � HEATIriG SYSTEMS Quantit5': �_ Make: `�;� ModeL• �-•---��� / ���� q� Fuel: _���, Flue Size: Tnput BT'CTs: � Output BTUs: 4 ll CFM: COOLING SYSTEMS�- Quantity. Make: Model: / � Tons: �t�n H.Power FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen Exhaust duct recalculating cfm No. Bath Exhaust(must have duct outside) cfm No. Other Fans: Locations cfm FUEL STORAGE(MUST BE APPROVED BY FIRE MARSHAL) Installation or Removal Fuel oil: gallons underground inside or. outside LP Gas: gallons Other Gas opening , . . . � PERMIT FEE CALCULAT�ON(S) 2002 State Statute �Yes This Section Applies The replacement of a Residenpal fixture or auvliance that meets all three of the following requirements: 1) Does not require modification to electrical or gas service. 2) Has a total co of$500.00 or less;excluding the cost of the fixture or appliance: and 3) Is improved,installed or replaced by the homeowner or licensed contractor. Skip next section; Cost of Permit $ 15.00 State Surcharge $ .50 � Mail-In Fee $ 1.50 If above does not apply,follovV guidelines below: 1. Contract Price*is .0125%of job with a Minimnm Fee of fS35.001 �D�X.olzs $ o (contract price) (minimum 35.00) 2. State Surcharee.**Add the State Building Code Division a Minimum Fee of($.501 A��.O v x.0005 $ / 0 / (contract price) (minimum$.50) 3. Postage and Handlin¢(Only mail-in applications) $ 1.50 4.TOTAL PERNIIT FEE(Alid lines 1-3 above) $ / r �J 'CONTRACT PRICE or JOB COST means the actuai or estimated dollar amount charged for the permitted work including materials,labor,pmfit,and other fixed costs.It is the amouut to be cLarged to the customer for the work done.If any material,equipment,labor,or installation is furnished by the owner,tenant or any other party the reasonable market value of such items must be added to the estimated cost or conttact price for permit fee puiposes.In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contcact. � � s»Tye STATE SURCHARGE is.00�5 of the contraci price under$1,000,000 or$.50-whichever is greater.For valuations over 51,000,000 call the D�partment of Inspectional Services for the price. The undecsigned hereby applies to th8 City for issuance of a Mechanical Permit,agrees to do all work in strict accordance with the ordinaaces of the City and the regulations of the Minnesota State Building Code,and ' es that ail sratements made on this appli 'on are complete,true and cornct ^ � �/ 0 Applicant's Signature: �� Date: Approved By: Date: � I � � , AMY LLOYD HV�#C LOAD ANALYSIS for � Amy Lloyd 9 2175 Shevlin Dr Wayzata, MN 55391 f lit� oftwarQ R���� Residential and Light Commercial HVAC loads Prepared By: I Steve Hawes TOTAL Comfort 12800 Hwy 55 Plymouth,MN 55441 763-383-8383 08-19-2004 1 � RHVAC-Residential&Light Commercial HVAC Lo ds Program * Elite Software Development,Inc. A-ABC Appliance&Heating Amy Lloyd � Minrleapolis,MN 55408 08-19-2004 Page 2 Project Summary Design Data Project Name: Amy Lloyd Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 Feet Outdoor Outdoor Indoor Indoor Grains Drv Bulb Wet Bulb Rel.Hum. Drv Bulb Difference Winter: -10 N/A N/A 72 N/A Summer: 90 73 I 50% 75 32 Check Figures Total Building Supply CFM: 957 CFM per square foot: 0.251 Square feet of room area: 3,816 Square feet per ton: 1,604.778 Building Loads Total heating required with outside air: 73,714 Btuh 73.714 MBH Total sensible gain: 17,938 Btuh 73 % Total latent gain: 6,563 Btuh 27 % Total cooling required with outside air: 24,501 Btuh 2.042 Tons (based on sensible + latent) 2.378 Tons (based on 77% sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. � ♦ ' RHVAC-Residential&Light Commercial HVAC L ds Program � � Elite Software Development,Inc. A-ABC Appliance&Heating � Amy Lloyd , Minneapolis,MN 55408 08-19-2004 Page 3 Total Building Summary Loads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3A Window Double Pane Clear Gla�s Wood Frame 313 14,141 0 6,506 6,506 8M Glass Door pouble Clear Glass V1/ood Frame 42 1,898 0 1,164 1,164 11 F Door Metal Urethane Core & Storm � 21 293 0 66 66 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 1,364 6,712 0 1,522 1,522 15C Wall 2-5' Below Grade 8/12" BIk+R-11 1,270 5,311 0 0 0 161 Ceiling R-44 Insulation 2,304 4,346 0 2,067 2,067 19J Floor Over Encl Crawl Carpet+ R-30 792 1,136 0 0 0 21A Basemt Floor 2'or More Below Grade 1,512 2,976 0 0 0 Subtotals for structure: 7,618 36,813 0 11,325 11,325 Active People: 7 0 1,610 2,100 3,710 Inactive People: 2 0 300 500 800 Appliances: '; 0 0 0 0 0 Lighting: 0 0 0 Ducfinrork: 0 3,070 0 478 478 Infiltration: Winter CFM: 375.1, Summer CFM: 214.3 376 33,831 4,653 3,535 8,188 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 17,938 Temperature Swing Multiplier: X1.00 Building Load Totals: 73,714 6,563 17,938 24,501 Check Figures Total Building Supply CFM: 957 CFM per square foot: 0.251 Square feet of room area: 3,816 Square feet per ton: 1,604.778 i Building Loads Total heating required with outside air: 73,714 Btuh 73.714 MBH Total sensible gain: 17,938 Btuh 73 % Total latent gain: 6,563 Btuh 27 % Total cooling required with outside air: 24,501 Btuh 2.042 Tons (based on sensible + latent) 2.378 Tons (based on 77% sensible capacity) ; Notes I Calculations are based on 7th edition of A�CA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. . ' RHVAC-Residentlal&Light Commerciai HVAC L ds Program -' � Ellte Software Development,Inc. A-ABC Appliance 8�Heating , Amy Lloyd � Minneapolis,MN 55408 08-19-2004 Page 4 System#1 Summary Loads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3A Window Double Pane Clear Glasls Wood Frame 313 14,141 0 6,506 6,506 8M Glass Door pouble Clear Glass UNood Frame 42 1,898 0 1,164 1,164 11 F Door Metal Urethane Core & Sto►tn 21 293 0 66 66 12H Wall R-19 + 1/2" Gypsum Board(P2-0.5) 1,364 6,712 0 1,522 1,522 15C Wall 2-5' Below Grade 8/12" BIk+R-11 1,270 5,311 0 0 0 161 Ceiling R-44 Insulation 2,304 4,346 0 2,067 2,067 19J Floor Over Encl Crawl Carpet+ Rr30 792 1,136 0 0 0 21A Basemt Floor 2'or More Below Griade 1,512 2,976 0 0 0 Subtotals for structure: 7,618 36,813 0 11,325 11,325 Active People: 7 0 1,610 2,100 3,710 Inactive People: 2 0 300 500 800 Appliances: j 0 0 0 0 0 Lighting: 0 0 0 Ducfinrork: 0 3,070 0 478 478 Infiltration: Winter CFM: 375.1, Summer dFM: 214.3 376 33,831 4,653 3,535 8,188 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 17,938 Temperature Swing Multiplier: X1.00 System Load Totals: 73,714 6,563 17,938 24,501 Check Figures Supply CFM: 957 CFM per square foot: 0.251 Square feet of room area: 3,816 Square feet per ton: 1,604.778 System Loads Total heating required with outside air: 73,714 Btuh 73.714 MBH Total sensible gain: 17,938 Btuh 73 % Total latent gain: 6,563 Btuh 27 % Total cooling required with outside air: 24,501 Btuh 2.042 Tons (based on sensible + latent) 2.378 Tons (based on 77% sensible capacity) i Notes I Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. � ' RHVAC-Fkesidentfal&Light Commercial HVAC Lo�ds Program =� � Elite Software Development,Inc. A-ABC Appliance&Heating � � Amy Lloyd . Mirmeapolis,MN 55408 0&19-2004 Page 5 System#1 Zone#1 Summary Loads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3A Window Double Pane Clear Glass Wood Frame 313 14,141 0 6,506 6,506 8M Glass Door pouble Clear Glass Wood Frame 42 1,898 0 1,164 1,164 11 F Door Metal Urethane Core & Storrii 21 293 0 66 66 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 1,364 6,712 0 1,522 1,522 15C Wall 2-5' Below Grade 8/12" BIk+R-11 1,270 5,311 0 0 0 161 Ceiling R-44 Insulation 2,304 4,346 0 2,067 2,067 19J Floor Over Encl Crawl Carpet+ R-30 792 1,136 0 0 0 21A Basemt Floor 2' or More Below Grade 1,512 2,976 0 0 0 Subtotals for structure: 7,618 36,813 0 11,325 11,325 Active People: 7 0 1,610 2,100 3,710 Inactive People: 2 0 300 500 800 Appliances: 0 0 0 0 0 Lighting: 0 0 0 Ducfinrork: 0 3,070 0 478 478 Infiltration: Winter CFM: 375.1, Summer CF�M: 214.3 376 33,831 4,653 3,535 8,188 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain TotaL• 17,938 Temperature Swing Multiplier: X1.00 Zone Load Totals: � 73,714 6,563 17,938 24,501 Check Figures Supply CFM: 957 CFM per square foot: 0.251 Square feet of room area: 3,816 Square feet per ton: 1,604.778 Zone Loads Total heating required with outside air: 73,714 Btuh 73.714 MBH Total sensible gain: 17,938 Btuh 73 % Total latent gain: 6,563 Btuh 27 °% Total cooling required with outside air: 24,501 Btuh 2.042 Tons (based on sensible + latent) 2.378 Tons (based on 77% sensible capacity)