Loading...
HomeMy WebLinkAbout2017-01160 - mechanical CITY OF ORONO * z 0 1 7 - 0 1 1 6 0 * 2750 KELLEY PARKWAY DATE ISSUED: 10/09/2017 ORONO, MN 55356- (952) 249-4600 FAX: (952) 249-4616 ADDRESS : 2800 SHADYWOOD RD PIN : 21-117-23-13-0023 LEGAL DESC : REG.LAND SURVEY NO. 1196 : LOT 000 BLOCK 000 PERMIT TYPE : MECHANICAL PROPERTY TYPE : RESIDENTIAL CONSTRUCTION TYPE : SOLAR ENERGY SYSTEMS VALUATION : $ 32,218.00 NOTE: SOLAR PANELS APPLICANT MECHAMCAL 402.73 ALL ENERGY SYSTEMS STATE SURCHARGE(VALUATION) 16.11 1642 CARROLL AVE MAIL-IN FEE 2.00 ST PAUL, MN 55104- TOTAL 420.84 (651)888-4173 Payment(s) Minnesota State License#:mech-BC665819 CREDIT CARD 3458 420.84 OW ivER BERGH, HANS&SHARON 2800 SHADYWOOD RD EXCELSIOR,MN 55331- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed acwrding to [he approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the State Building Code.This permit may be revoked at any time for due cause. ��1/LC_C�.-�.-�e c� ,� � � ' l� l cI l / � Applicant Permitee Signature Date [ssued B ignature Date PLAN REVIEW CHECKLIST FOR NEW STRUCTURES / ADDITIONS Address: J � Permit No.: ���`' � «�P� Description of work: �(Q /Q'� y"cP�2�2i`� Date Rec'd: Septic review by: Date Approved: Zoning review by: Date Approved: Building review by: Date Approved: Grading review by: Date Approved: Zoning District: Zoning File#: Resolution? Yes Reso#: Reso Date: Signed: Yes No Resolution/NA Zoning: Lot Area: S /AC Width: Structural Coverage: SF % Survey Submitted: � Yes � No Date of Survey: Revised date(?): Landscape plan submitted? 0 Ye Landscaper: / 0 No/None proposed Pro osed Setbacks: Front(Lake) Rear(Street) N S E W ) ( N S E W ) Other Buildings Wetland Side Side Buildin Hei ht Anal sis: Distance Between First Floor and defi ed Top of Roof*( ee"building heighY' �a� � definition : First Floor Elevation from buildin la s : , (b) Highest Existing ground level (per surv y)or 10'ab e lowest ground level, ��� whichever is lower: Difference between b and c *: (d) DEFINED HEIGHT *If highest existing adjacent grade is above F E-Height is(a)-(d): (e) *If hi hest existin ad'acent rade is below F Hei ht is a + d Shoreland District MCWD Pe m t Average Lakeshore Setback g�uff Met? � Yes � No Permit Number: � 0 Yes 0 No 0 N/A � Yes � No � N/A—see attach�d Setback: � Stormwater Quality Existin,g Proposed � Overlay District Tier Hardcover Hardcover Variance Required CUP Required ' circle one % and s % and s �i 0 Yes � No � Yes � No 1 2 3 4 5 Type(s): Type(s): , l Updated: June 2017 z:\forms�plan review checklist 06-2017.docx 1 Fees to be Char ed • YES NO Permit Plan Review State Surcharge Investigation Fee SAC—Number o#SAC Units Other(specify) , S uare Foota e $ er S uare Foota e Basement X = $ 15t Floor X = $ 2nd FIoO� X = $ Garage X = $ /� /� � Estimated Construction Value: $ �� , G, ��9 � Orono Inspections Required Work Requiring Separate Permits 0 Footing 0 Site � Plumbing � Grading/Filling � Poured Wall � Silt Fence/Erosion Control � Mechanical 0 Fire ;I � Foundation Survey 0 Hardcover Removal � Fireplace 0 Water Connection � Framing 0 Other(specify) 0 Masonry 0 Sewer Connection :�' � Waterproofing/Drain tile � Mfg. � Lawn Irrigation � Foundation Waterproofing � Other(specify) 0 Landscaping raming 0 Septic � Insulation � As-Built Survey Final 0 Lathe Required State Permits 0 Other(specify) � Well Electrical REMARKS (in-house): OFFICIAL REMARKS -TO BE NOTED ON PERMIT AND INITIALLED: � See Builder Acknowledgement Form { i 0 Prior to release of escrow money an as-built survey and hardcover calculations must be submitted and approved. Fi � i ' 1 , I Updated: June 2017 z:\forms�plan review checklist 06-2017.docx ,�p Cl Y USE ONLY � , �O A' City of Orono R��.►���E� L���) / � ��/��� �� J �VO P.O.Box 66 Date Receive � Permit 2750 Kelley Parkway Crystal Bay,MN 55323 �� � n 201'� Approved B . Amount$:_� Phone(952)249-4600 Fax(9 49- 6�lki a � y�' �� CITY OF ORONO ��kfSH��� CITY OF ORONO — SOLAR ENERGY SYSTEMS PERMIT GENERAL INFORMATION 1. You may apply for a Solar Energy Systems permit by mail or in person at the City offices. All Solar Energy Systems permits require a site plan and review by the Building Official. Specific Solar Energy Systems information can be found in City Code Section 78-1379—Alternative Energy Systems. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. When any new construction or remodeling is involved, a separate building permit must be obtained. 4. All wark must be done in accordance with the Uniform Mechanical Code/State Building Code; Underwriters Laboratories,Inc.;the National Renewable Energy Laboratory;the Solar Rating and Certification Corporation or other body as determined by the building official. 5. All work must be inspected(rough-in and final). Call(952)249-4600. ����� ��� (24-48 hour notice required) � TYPE OF PERMIT (Check All That A 1 � New ❑ Addition ❑ Repairs ❑ Replace Job Site/ Owner Information: Site Address: 2800 Shadywood Rd Owner: Hans Bergh Mailing Address: 2800 Shadywood Rd City: Excelsior Zip; MN 55331 Home Phone: (612) 670-7446 Alternate Phone: Email Address: Contractar Information: ❑ Insurance—Current: Contractor: All Energy Solar Contact Person: Kristen Sachwitz Address: 1642 Carroll Ave State Bond #: BC665819 City: St. Paul, MN Zip:55104 Expiration Date: 3/29/2019 Phone: 651-888-4173 Alternate Phone: de� Email Address: kristensaes@gmaii.com Compliance City of Orono Date 1 Permit Created: Januarv 2015 � 1 Reviewer .�J ' . CITY OF ORONO—SOLAR ENERGY SYSTEMS PERMIT, continued Before approval and issuance of permit(s) for Solar Panel/Photovoltaic systems, applicant shall submit the following minimum information. Required drawings shall be scaled and dimensioned, readable, and legible. Additional information may be requested. Plans Prepared by: ' Company Name: All Energy Solar Contact Person: Kristen Sachwitz Address: City: Zip: Email Address: Phone: Alternate Phone: Description of proposed work, including both solar equipment installation and all associated construction: Installation of a flush, roof-mounted solar PV system. 1. What is the system KW rating (DC)? 6.785 2. Is this an inter-tie or stand alone system? (Circle one) 3. Does the system include battery backup or an uninterrupted power supply (UPS)? ❑ Yes � No If yes, give the number, size and location of batteries. 4. If rooftop mounted, identify the following: a. ROof Type: ���.w�r�b,��,,e'o�� r►brmdi.Yan.3/.•nwra�ave�qywa� , nppm.mWeerodsiope ❑ Flat roof(nominal pitch) �+�^��ta«a����� � ��a_��� � Sloped(identify pitch) 9.72 : 12 �m,"�,"";� � ,�ww,,,�,o�yn„d�w � Emtin92�h�eo � Indinte lag Bdtl: � b. The type of existing roofing (shingles, tile, »s•�z„r�ho� r'"'h"z`'°` � 5716'boqsl'Imqrt�a i metal,ballasted,membrane, etc.) "°'bo�""''°"�'h ' Shingles �°°'�0�dun�'°" � c. The number of roofing layers that will be under the panels � (no more than 2 layers of shingles are allowed). d. Identify the condition of the roofing material and appropriate age. xamp .o a a»ttng cross-sechon i ustra lon New Permit Created: January 2015 2 ' . CITY OF ORONO—SOLAR ENERGY SYSTEMS PERMIT, continued Required Drawings and Plans 5. Provide construction drawings that include a building section detail and complete notation of method of fastening equipment to the roof of the subject property, including the following details: a. Cross section that identifies rafter size, spacing and span dimension and approximate roof slope. b. Identify style, diameter length of embedment of bolts (i.e. 5/16" lags with minimum of 3" embedment into framing, blocking or bracing. 6. Provide an elevation of the structure indicating the appearance of the proposed solar installation. Note the 4' finished height of the system above the roof. 7. Provide a site plan indicating the buildings and features of m � the property. The site plan shall show property line locations, approximate location of all structures, the � � location(s) of the panel installations, setback from property lines, the main service location. xam an e enahon 8. Is the equipment to be flush mounted to the roof(mounted such that the collector surface is parallel to the roof)? � Yes ❑ No, if no see#1 l. e� Please Note: No point of the collectors or the mounting system shall extend above the peak or ridge height of a pitched roof. On T a flat roof, collectors and their mounting systems shall not �,� I extend more than 5 feet above the surface. za Maximum Area. The collector and mounting system of a roof- �24,--� mounted solar energy system shall cover no more than 70 percent of the roof to which it is affixed. 9. The minimum structural threshold for installing a flush-mounted PV system is a roof structure with at least 2 x 4 rafters no more � ioa r than 24" on-center spacing. Does the roof structure use 2x4 or lar er rafters s aced no wider than 24 inches on center? '"g-0 $ , p r sdarpands� �] Yes ❑ No, if no see#11 � 10. For roof installations, roof decking and structural supports 40' should all be in good condition without visible roof � sag/deflection. Is the roof structure in good condition, having no visible sag, cracking or splintering of rafters, or other potential structural defects? � Yes ❑ No, if no, see#11 f-z�'--I If roof structure is accessible, please provide photos showing the condition of the roof. If roof structure is not accessible, please _ provide an exterior photo, side view of the roof. i—aa--i Example o�a sife plan Permit Created: January 2015 3 CITY OF ORONO—SOLAR ENERGY SYSTEMS PERMIT,continued Required Drawiags and Plaas 1!. lf the answer is no to any of questions 8 — 10, please provide the follawing additional documentation. a. If not a flush mount system, provide a side eievation identifying the pitch and height of the collector and mounting system relative to the roof. b. Provide a study or statement regarding the proposed solar installation and a!1 proposed structural modifications stamped by a Minnesota iicensed/certified structural engineer. Approval can come in the following forms: i. Construction plans denoting the roof structure and any modifications to the structure if required, as well as the methad of installation of solar coflector on the subject property. ii. Letter from engineer accomplishing the sarne as above if the engineer fcels that lctter format will provide the necessary information. _ " _ . -,-.. , ". ��EE�:�C t "�Ol� S If above dces not apply;follow guidslines below: I. CONTRAGT PRICE •is 1.259`0 of contract price with a(Minimurn Fce of SS0.00) 32,218.00 x.0125 S 402.73 (contr�t price) (mfaimam 530.00) 2. STATE SURCHARCE 32,218.00 x.0005 � 16.11 (oomract price) 3. POSTAGE&HANDLING(Only on Mai!-In Applications) S 2.00 4. TOTAL PERMIT FEE(Add Lines 1-3 Above) S 4z0•$4 ■ * CONTRACT PRICE or JOB COST maans the actual or estimated doller amount charged for the permitted work including materials, labor,prafit,and other fixed costs. It is thc amount to be charged to the customsr for the work done. If any material,equipment,labor or installations are furnished by the owner,tenant or any other party,the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job c.rost, the City may rcqucst thc submission of a signad copy of thc actual contract. ; s.o�x+�i�t s�rs ' ����, ��►►�o .�,�� � The undersigned hereby applies to the City for issuance of a Solar Energy Systems Permit,agrees to do atl work in strict accordance with the ordinences of the City, the regulations of the State of Minnesota, Underwriters Leboratories, lnc.;the National Renewablc Ene�y Laboratory, and the Solar Rating and Certification Corporation and certifies that all statements made on this application are compleie,true and correc� Applicant's Signature: Date: 9/19/2017 Pe.niit Creared Januar��20/S 4 � /���.. � `� % ��. � , �_._ ,��� / i � ; , � , . �= i . � �� � 0 � r ELECTRICAL ,TION MAY ADDITIONAL I TO SCALE I METER WITHIN ;TIONAL METER. D IN iTED WITH dD PLAQUES )• Sy q0� r �' �. � t � � z t t; ;� �� � � �. �� � t f � s,, . � 3, � �: � � E, � ` � ` �' r �" � _ _ .�, � � �, �;.�' � � Gx: � �: , �� c , `, -; . � I ;. . x: : ;, r. x �, £ € � � u ��„ �` � �x� � � �� � � � �SR�'nt �� � �. �' r � ,�. , � , �..... p .i,:-, *#f � k :z,° �, �, k t N ,"�. �,� �, 'r;� 'fi . ! �'+ f ,x i � G �+r i ;�,� �'; Ij • � � • � `�'.a � �� � �. � � � � ' j' ^A. _ � r� �. _ �� . V a4,,,+�"� �� C'"�""^ ' gcer ��,,.�r � _......._.:.1 � We offer solar modules of unsurpassed quality that exceed performance expectations __ at an affordable price. �I�' i P ! �, � ^ High-efficiency monocrystaliine silicon � � PERC cells � �F�� . Certified PID-free above and beyond the industry standard Full quality check of every module � x , � along the production iine ¢ � .;��� i 3 Impact resistant,anti-glare solar glass j i Our Declare listing shows tommitment -- � � ' � to transparent, sustainable practices "� ���="`�� Connect with us:www.itekenergy.com � info@itekenergy.com t)ec#1r�e.. � � �� � nNc En�roy SE MOAuIs � O' ' � ltok F•nNpY�LLC .�...�.���.R..�:.�s� � E N E R � Y {,N1(}y��WK�4�Y yn � InOMUe�Oetlena.l Me.duiA�W�m:•{&e�r.`qnm+ Wx� .�,e..�.-,v.:.�......_..._�:._............�-.� ._»-._.,.;,_...,-,.. .....: We Oeclare6 our product with ASSEMBLED Buitding Solar � Powering The Future The Living Future Institute IN U.S.A. � . Itek SE b0-Ceil Solar Module Design & Engineerir�� Data Cell Type •60 high-efficiency monocrystalline p-type cells • 6 x 10 cell mqtrix SolarGlan� • Ultra-dear anti-refleciive treaiment �a l � •Tempered,with low iron content • Anti-glore prismalic subsurface texture Backsheet • Multi-layered • Engineered adhesion for maximum weather protection Dimensioru 1001 mm x 1675mm x 40mm Rame • High-strength corrosiornresistant anodized aluminum Weight 43 Ibs •Compatible with standard racking,accommodating both top-down clamps and botiom-flange mounting ------------------- - --_..__.._ Cable • 42"90°C 12AWG PV wire Junction Box • 3 bypass diodes • 1000 VDC MC4 connectors Operational Temperalure -40...+90°C Grounding • Certified for Wiley Electronics WEEBT"'grounding clips MmdmumSystem Voltage 1000 VDC • Eight standard grounding locations per module for ------------ ------------- -- - reduced ground wire length Design Load(UL 1703) Up to 1 13 Ibs/ft� _ .. -- ------ ----- ---._ -- ----- —.—_—.._------------------- Ma�dmum Lood�UL 1703) 1 13 Ibs/fi" Warranty • 25-year power output • 12-year workmanship Mwdmum Wind Load 1 13 Ibs/fi� ------------------ - ---- ---_— _- McncSeries fuse Rafing 15A UL Listirig UL 1703 Ma�c Reverse Current i 5A Flre RoTing Type 2 PID Free 500+hours Nominal Operating ARRA,BAA, and TAA Complfant Cell Temperature(NOC� 45.01°C Temperature Coefficient of P� -0.39�/°C Temperahxe Coefficient of Voc -0.29%/°C Mmdmum Power-P�(Wp) 295 300 305 Temperature Coeificient of Ix +0.04%/°C ---—_____-------------- -- - Mcndmum Power VoRage-VMPP(V) 32.8 32.9 33.1 Temperature Coefficieni of V�r -0.38%/°C Mmdmum Power CunenT-I n,rr(A) 8.9 9.0 9.1 *Electrical characleristics may vary within ±2% of ihe TS40,L OpenClrcuttCurrent-I�.,Nc(A) �2 �2 �2 indicaTed values at Standard Test Conditions (STC): TS4-LOpenCircuitVoRage-Voc(V�" 37.8 37.9 38.1 Irradiance oi 1,000W/m=, AM 1.5 spectrum, ceil temperature at 25°C. For full electrical data on all OpenCircuHVolTage-Voc(V) 39.7 39.8 40.0 wattages please see installaTion manuol. Shat ClrCuif Current-Isc�A) 9.6 9J 9.8 Noie:specifications subject to change without notice. Module Hflciency 17.59% 17.89% 18.19% **TS4-L is temperaiure indepcndent tot.smm 2o3mm [4��] �8 in] 9.5 mm 5 mm �4375 in) �[.198 in� � TYP TYP TYP TYP 79.5 mm [3.13 in] ASSEMBLED 100 mm IN U.S.A. �3.94 in] � 27 mm [1.06 in] �► CER71itE0 MJIDf ' ��1 ITIfi'1 IM WASN�NGTON 1067mm 178 mm [42 in] [39.41 in] � P in] - � + 947 mm [37.28 in] CErtni�Fo MnDE 127 mm IN MINNESOtd [S in] JUnCtiOn BO% 610 m �24 in] � ��� ARkA,BAA,onE iAA kame Depih:40mm[1.57 in] Solar ProJecl Complianl �w/ 1219 mm � � �a8 in� 1675 mm Interoelc r [65.94 in] Manufacturing Facilities: 3886 Hammer Drive, Bellingham,WA 98226 � 2746 31 st Avenue South, Minneapolis,MN 55406 Sales Offices:WA: (360) 647-9531 � MN: (612) 318-6384 � CA: (360) 393-0178 info�itekenergy.com � www.itekenergy.com ��6•��•�� Friday,January 31,2014 ��� ����TM SnapNrack . � o r m a n 775 Fiero Lane,Suite 200 � San Luis Obispo,CA 93401 "Series 100 Roof Mount" Cover Letter cheel To Whom It May Concem, We have performed calculations for the 100 series roof mount PV system based on t r u c t u r a 1 the information provided by SnapNrack. Included with this letter are the report and calculations. We did the calculations in accordance with the 2012 IBC, ASCE 7-10, 2012 NDS, and guidelines stated in the Solar America Board for Codes and Standards. n g i n e e r Some of the components in the SnapNrack test data were used to determine the capacity and section properties of materials. We collected the test data using the so22 sun�ise at�d procedures outlined in the 2012 IBC Chapter I7. Fair Oaks,CA 95628 (916)536-9555 (916)536-0260(fax) We included the following types of load combinations and building parameters into our calculations: 1989-2013 Z4 years ojercellence . ASCE 7-10 wind speeds from 110 mph to 190 for B and C exposure categories � ASCE 7-10 Seismic Design Category E • ASCE 7-10 Snow Loads up to 120 psf ground snow • Buildings with mean roof heights up to 60 foot tilt angles / roof pitches Norman Scheel,S.E. �n►0 degrees to 60 degrees. �en Ar Bo+c LEED AP Homcs The calculations have also been completed in accordance with the 2006 IBC,2009 Fellow—SGAOC IgC,and ASCE 7-05. To use the data contained in this acket for ro ects that are Fellow-ASCE p p � E-mail:normr�nsse.com being evaluated to the older ASCE 7-OS wind speeds,refer to Appendix A for a wind speed conversion chart. Find the ASCE 7-OS (IBC 2006/2009)wind speed in Rob Coon �e Chart in A endix A,identi the corres ndin ASCE 7-10 IBC 2012 wind General Ma►iager PP fY � g � � E-mail:robcoon�?nsse.com speed value, and proceed with using the charts contained in this packet with the Steve Smith P.E. adjusted wind speed value. Project Manager E-mail:stevcsmithCa�nsse.com In our opinion, the mounting system, outlined by SnapNrack Series 100 PV Mounting System Code Compliance Installation Manual, is acceptable and meets Steven Cooksey the loading requirements as stated above. See the report and calculations included cAn s����so� with this letter for more information. E-mail:ste��e�nsse.com Jacide vVinslow If there are any further questions,please contact Norm Scheel, �~` orfi��Me�s� N►►► SC' E-meil:iackie[�nsse.com Norman Seheel PE, �E �0� �� LEED-AP BD+C,LEED-AP Homes Felbw SEAOC R IS ERED. Fe�toW,�.s. . PROFE$$IQNAL � EiVGINEER No.21393 . � • CERTIFICATE OF COMPLIANCE Certificate Number 20140204-E359313 Report Reference E359313-20140201 Issue Date 2014-FEBRUARY-04 Issued to: SNAPNRACK STE 200 775 FIERO LANE SAN LUIS OBISPO CA 93401 This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, representative samples of CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS USL—Series 100 Mounting and Bonding Systems for use with Photovoltaic Modules Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s)for Safety: UL Subject 2703-the Outline of Investigation for Mounting Systems, Mounting Devices, Clamping/Retention Devices, And Ground Lugs for use with Flat-Plate Photovoltaic Modules and Panels Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark should be considered as being covered by UL's Listing and Follow-Up Service. The UL Listing Mark generally includes the following elements: the symbol UL in a circle:�with the word"LISTED"; a control number(may be alphanumeric)assigned by UL; and the product category name(product identifier)as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. �,��rr /1. �� WIIIIam R.Camey,Dlnetor,NoRh American CertlflcaHon Proprams �� UL LLC My information and documentaHon InvoNing UL Mark servlces are provldad on behalf o(UL LLC(UL)or any aulhorized Ileansee of UL.Fw questiona,pleaee coMact a local UL CuNomer Servlee Rep�eaeMatNe at www.ul.coMcoMactue Page 1 of 1 �' :� � ��;����������"��� - Snc� � �.R rc�ckTM �� � r�� f� � q � ��� f �.s� �« s �����v � . Solar Mounting Solutions � �,�`� ._ ,.�� . wr ,:,,� _ ��tl�_ Series 100 Residential Roof Mount System ���,�:.�.�e�. The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 UL is listed to the UL 2703 for grounding/bonding and fire classification. The System's components provide an adequate bonding path which has eliminated the need for grounding lugs and wash- ers at each module, and bonding jumpers between splices. In addition to grounding and bonding, the roof mount system, Series 100 UL, is Class A Fire Rated when in- stalled with Type I and Type II Modules. SnapNrack's UL 2703 Certification and Com- pliance ensures that SnapNrack installers can continue to pravide the best in class installations in quality, safety and efficiency. � Appealing design with built-in aesthetics � � No grounding lugs required for modules • All bonding hardware is fully integrated into the components =����'rv � r� �: � ; • Rail splices bond rails together, no rail jump- �' + �`"� � ��` ° '� ��� ������`� �� ers required �� �`��������� • Proprietary SnapNrack grounding lug snaps in the rail channel • No drilling of rail or reaching for other tools required • Class A Fire Rating for Type 1 and 2 modules System Features Include �,r ��„��_ �aR .,� 5p .. ��6`k,¢ �`��:k �"� f�'",�`�Y����e3 „p k�„� ��„ � : .�r._� �. � •'� ., '��s ��, .. .�`�,�' �ii �'�.�•_ ,� . .,. , y,. Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling ,'� �Y �� �.. 6 bQ.. � �� �' O Integrated Wire Preassembled Integrated bonding UL 2703 Certified Management hardware Resources snapnrack.com/resources :' Design configure.snapnrack.com ,` Where to Buy snapnrack.com/buy t �`t, � r� ���,��( � a�� '� p y .. � Snc� � ����� rc�ck �xt: �� � :�� , ����.� � � �a�.1����� �a��eF� ��,��� :r. � ��r��:� y�y'���`���,�d Solar Mounting Solutions ��`���fi��f� w �rc��� � � �a � d� a' �i��yr�.. � � s...,,,;��...sE.n��_,�..��•. ,.� .> Stainless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Split-Lock Washer Bolt with Split- Splice Insert Lock Washer SnapNreck Bonding SnapNrack SnapNrack Adjustable End Splice Clamp Top Bonding Base Mid Clamp SnapNrack SnapNreck Bonding Bonding SnapNrack Stainless Adjustable End gonding Channel Nut Clamp Bottom Channel Nut Stainless Hardware with Bolt with Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding SnapNrack Bonding Washer AdJustable End Clamp Mfd Clamp Standard Rail Splfce SnapNreck Ground Lug 12-6 AWG Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave �� „ , UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff Clamp Assembly SnapNrack� Serrated Stainless� SnapNreck SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNreck Stainless SnapNrack 92 Degree Flange Mill Finish L Foot Bolt Standoff � SnapNrack SnapNrack AllPurpose Mill Finish L Foot Standoff BaSe<7-Hole SnapNrack SnapNraCk Base Shown) SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapN►ack Bonding SnapNrack Bonding SnapNrock Metal StandoH Assembly L Foot Base with Flashing Roof Base with Bondin9�Foot • • � • � � �90{)0'���'1£'S��L�'1 r��'3l�FT�;� � �"'� � �. ,'. z v" � �r �;� - , �� � i �" � � � M�tprl�ls� � 5ta�nl�s�s�S��Q1 �' �``� � �� . °� , - � ,- , ''� k � :� �� � - • ��lvarii�ed 5teei�r�c�.�i�a�+����!���i��ta`�, .� : ` � M . ���:7 . . � e. ...� .. . , • Clear and black anodized aluminum Material Finish • Mill finish on select components , v.> � L�sted��o L1L�S�Y�c�d�r�9������d5�r���,���di�glBo�acli�g�r�d',F.a're Cl�ssi�icat��r� �. �, � . . , . �. � ,' : ;I ' e . ., a ' . x:,,. 3 � _ �' ��Calts:&�t�r��ifica�lt�ns,. ���lass A��r��'2��nr�3'y����a�d`fy��+���cSC�ules • St�rr�pecl"St�-u�t�raf Ei�garoe�er�rac�f��parts��ir a11 50�ta�es. • SnapNrack Grounding Lug (One lug per individual row of modules) Grounding • Integrated bonding components .�� - � t�. � .. � � �, ; � , :� �, Wartanty . ` l0.y��r lir�'rted prod,ucE warra�ty;�5 year lamited finis�a v�arranty "; 877-732-2860 www.snapnrack.com , contact@snapnrack.com Y f,= r'�y �°�.. :. a . �� t�z": �F Required Tools ,� �� �Y -:. Hammer Or Stud Finder � � � ���� � Roof Marking Crayon Dimensioned ` � � � � Drill with 1/8 inch Pilot Drill Bit �� �'�� �_ ` � Roof Sealant L-FOOt � � �"�� ��,� : ` Torque Driver with Bit Adapter , „�; ��� '����������,'�': 1/2 mch Socket Wrench ,_„z��� S,v'x'.�q�� ��`,a`+�5`��w � �w� ' - � ���R�, 1, Materials Included in Series 100 L-Foot Kit: �''`=��` p (1) SnapNrack Flashed Base { � a� '� �������� p (1) SnapNrack Composition Flashing � ����,i�.�� p (1) SnapNrack L Foot, Composition 92° �`����'����� O (1) 5/16in- 18 SS Flange Hex Nut 3" gZ° .�� -"-����,����-� p (1) 5/16in SS Split Lock Washer �`� �� `� -���r�*'�� p (1) 5/16in- 18 X lin SS HCS Bolt ����� ���`��h �"� p (1) SnapNrack Channel Nut, 5/16in - 18 �n��� .��� � ��� �`� �' � ����� :-. Other Materials Required: � ��� � � :���'c." f � pr j,�� "is � �„ ����a�; 1-3/4"�� r � �� ���� � (1) 5/16 in Lag Screw �� 3 ��`� .���� � (1) 5/16 in Washer � �� �� �:��� E7 ��� ��O _ ���� ��°������.' � � � ���� ��� �� ' . �'���� �`� ����`` ��� �� ,,����`���'� 0 � � O . ,c � ,��.�'���<r.. � e�= � ��� f�WY �����' � � ��� �. '€�,����4�, O ' � ����� ' � � •p �; �.- � When To Use: , � Composite Shingle Roofs � Technical L-Foot Data: � � �M�,,� ���-�, �,� �� a � �_ � - �� �'�� �;�,���'���`""� ""s, �„.; a . , �, — ,� � �r,�, �; Dimensioned Assembly � ,.. 2 � Z �.. �4„� I . l2 6 Series 100 . . . . . - Flashed L-Foot �[.�G"5a�.�` "�E,{.�"�� E�����"���.€ 1�"�;�"�;: � 1) Locate the rafter underneath �`, ) "� the decking of the roof by looking �- �� underneath the eaves or in the attic. 2) Drill a pilot hole through the __.— roofing material into the rafter to ensure that the lag bolt will be located into a solid portion of the rafter. If the rafter is not found then seal the pilot hole immediately with roofing sealant. 3) Apply roofing sealant to the bottom of the base and - ' � ' - � ' - - directly onto the lag bolt to ensure a water tight seal. 4) Attach the L-foot base with F� a 5/16" lag bolt and a minimum � � � . - embedment of 2 Y�" lag shank . '' into the rafter. Tighten Lag bolt } 1 to seat with a hand wrench. � -a- �- � .�W 5) Slide the flashing underneath the row of shingles directly above the installed standard base and then line up the hole in the flashing with the threads on the base. It may be necessary to pry up shingles with a breaker bar. . . 6) Attach the L-foot to the threaded � �,. . portion of the base that is protruding from the flashing. Then tighten the flange bolt over the threads to 10 - 16 ft-Ibs. The L-foot can , � be attached in any orientation. ' � � �,�,* �� `� �, �*'�'�',_.__ << . ��y�s E���; -SnapNrack engineered systems should oniy be used with SnapNrack cornponents and hardware. Any alternate application ,., ,,,�.f_ ,.� � - � may void the warranty and structural --�� - calculations could become invalid. .-' i' l„r ." �- . . .�.� ,�,..�.. . . � . 6 a .. , .., .. . .. . �,��.�a. E i��.�i���,x= � � ~ ' '�"" -If a pilot hole is drilled and a rafter is not .. found immediately seal pilot hole with � � roofing sealant to avoid water damage. -Do not over tighten hardware. -Always wear fall protection and safety gear ��������a� � �}�;�&�,� .: SnapNrack has a suite of design tools � - to help configure your PV installation for accurate and fast install. Please visit us at: www.SnapNrack.com �f ,.�, 4 '�. I ��s�u � ��� 1 �� , � ��� Required Tools: � ` # �� Level �� ���� r�> � � String Line or Spare Rail ��,������ � r � � : , Pitch Meter ��� � ��� �° ,� . 1/2in Socket Wrench �w ��,y ,; �wr 5/32in Allen Key �� . � �� �� � ��. Torque Wrench � t"�� � �� . '% � -.;,��tr"���� r�,�. , �� � ��� . Materials Needed to Instail and Level Rails: � ����a� : � � � � � 4 SnapNrack Standard Rail �' � �����,~��°�� �� 0 SnapNrack Splices a� � w � ��,�µ "�,���������� �� � 1" SnapNrack Standoff Spacers � `fi �.�� � j�: O 5/16" - 18 X 1" Fully Threaded Set Screw ���a;�'�`���� � � 0 Pre installed SnapNrack Roof Attachments (L-Foot Or Standoff) � x y,���,r ,s c _a 4:' u '�; �6��a� � � � __ � � ��M4'���°'��� ,.. �� t-:4vi .� � 4, :C �.v 4 �.':. ���'� w�, °�� � - �, t�F�'? d,��{ Z �. �,�> � �,' � �w^ �,+�"h1 w ,.. � t'c'Y�hy.f,,Y Y ��,�E .��fS�., y �,. ��`� �fi �� �3 ` �Y` �y'} sK �-� £ ka'fi". ����a-��fi���..�� �.' � � °b 0 (4 1�4'r�}i£�''� �,� � ���, O �b � ����� � �� '�������� � 0 ���'. a ��,�,ma� � �: �y�ia�������� �,� �*����:�. � � S ..� "�� M.,�' � � �4.�r ,�,,Y�' .�9 � � Q 0 A Standard Rail Profile Technical Rail Data: x�, , � s �F � � t�a � w-< — ,� �i�� " ���`.�r^�'h �:' �k � t`�k,.: � � ��'��S�yp++6M��% � � �,-e t yA . � F ' .. •�•' ,�'Y n'�_. y�'i$�{ i���;}�k h���}4 $ _ C.Ci �'.'�� � �i 2_{�Z11 � �� � • � a . �; �� � �,ar•h 1-1/2'�I Technical Rail Splice Data Rail Splice Profile , v � � , �t s,, '^ � ' . ,{�,�F �., $��k�� : � �. .C"��"` f�. � �� t�. . ,� _, �: �'�'s.c�s<».. �a�s ��`"�r� �� `� '�i��r "'p > � , {�9���� `� ��s��.�d�� � : ��, ������ F� w �`fi�, 1-1/2" a�uaBr��� �� � �rs �`"T��`� �'`� � �';.,t���'�� ;rk 4r�9y � �`� 9 ti��,::. . A s�., �-,.�*�`i ,.� .,i � �� #x�R'�. ,e"4C"'�:��.:'a ';a-� "�' �4���b�i 'k'.+H 1,�, 1-3/4" .�;� 2 2 . . - . . . Series 100 installing and Leveling � �.� � 4 Rails �.� �� , . � ��°.� "�`�', � `;�'� � ��,ti�t��� � � F A' �^".�� r ���.����rc�k��`�'����� ���.�5���.+!�F"� ��..�`��� .. "`>� ° ' ' ' 1) Set all of the rails into the attachments ��. �- � ,��� , � �;`= • � by snapping the channel nuts into 4,`.� �,�r, ` '�" �` the side channel of the standard rail. �, , " � ` �; Connect multiple lengths of rail end � ' ��- `� ���'��,��� � : to end with the SnapNrack splice. �� = .� � �,�,� �� �� �- ����*' , �', :�, r�-- 2) Find the highest attachment point of the roof, and set that attachment point to the lowest adjustability. Level � . � � � the bottom rail of the array to the roof by tightening attachment points. � Torque silver hardware to 10-16 ft-Ibs �'�``""""`�"`-,�x�''�� and black hardware to 7-9 ft-Ibs. �.. �,�-� u� �'�'�",=r�r,�`�,�` -�.� a.�� .:- .� ��� �:' 3) Using a string line or spare rails run �� '� �r� P �� �`°� { � from the bottom rail to the top rail and � �-� � d, , �"�� ` � .. ,.:.,�.�_ �:�' raise the top rail, then set the desired �"��'�'' f F �_ " `�"° pitch of the array by adjusting the top r���� ��� � � ��:����� � � -� �:� rail. Add leveling spacers if needed. ; � - �'., r'. `�# �fE^Ey �b �� ;� � ,�,�� , ,���� �� � . y� . , ; 4) Level the top rail by moving the string �'�` line down the length of the rail, matching pitch over the entire length of the array. 5) Level the remaining rails to the " " " • ' " string line, working out from the middle • • rail. Add leveling spacers if needed. _ �a-�~ ;� � 6) Tighten all racking hardware, torque silver hardware to 10-16 ft-Ibs and � "�45���� `�,, , all black hardware to 7-9 ft-Ibs. � ' z�� ���r� � �1 ... � � �AY4 'x d ?+� * ���;. ' ..�ro�.. �R • Y`���;X E�;'{'; �� � � � � � -SnapNrack engineered systems should ..,.- . . . ..- - - ;� �` __ �� _� � � _ only be used with SnapNrack components ���r � _ and hardware. Any alternate application ��� 3'� �' may void the warranty and structural � ��� , ��. " • - •- - • • • - calculations could become invalld. �' . .. . . •• . - •. - • • • - . ��e�E z l ��[`:€'�€g;. l .� -� �;,� � � � � �� ���� -If a pilot hole is drilled and a rafter is not � �,;.. .�q,+�, found immediately seal pilot hole with __ '�'� ���J roofing sealant to avoid water damage. p. �� -Do not over tighten hardware. • • r. .i ,,'Y'��. � -Always wear fall protection and safety gear . �ri�l. ''���� .. `!� i ���� _ I. ���r��_��� ���:�c��:� �r,� � SnapNrack has a suite of design tools `��, �• � � � � to help configure your PV installation : J � � � .. for accurate and fast install. Please visit us at: www.SnapNrack.com