HomeMy WebLinkAboutRe: plan review notes/2004 � . a.
.
,
Date; 10-18-2004
Plan Review Notes
Address; 2377 Shadywood
Project; Addition-Remodel, Coffee Shop
Architect; Martin Woody
Contractor; Owner
Owner; Christine Valerius
Inspector; Lyle Oinan
Occupancy Classification; I.B.C. section 303.1 A-2 Occupancy(main Floor)
I.B.C. section 311.1 S-2 Occupancy (Second floor)
Constniction type; VB
Location on property; > 30' to property lines, no requirements
Allowable Height and floor area;
Height, 1 story Max- 2 story allowed with sprinkler -proposed 2 story
Basic allowable floor area 9000 sq. ft. -4256 proposed
Means of egress; Occupant load -Baseinent; 800 square feet divided by 300 = 2 occupants
-15t floor 1440 divided by 15 = 96 occupants
_2°a floor 1376 divided by 300 = 4 occupants
Total 102 occupants
Egress width; table 1003.2.3
Basement - 2 times .15 = .3
1'` floor - 96 times .15 = 14.4
2"d floor - 4.5 times .15 = .675
Total required= 15.375, Proposed 180 inches
Number of exits; table 1004.2.1 Group A>50 occupants req. 2 exits -4 proposed
Requirements;
-I.B.C. 302.1.1, 302.33 and table 302.1.1 requires a one hour separation between group A2
and S2
-I.B.C. 1003.2.10.1 Exit signs required when more than 1 exit is required
-I.B.C. 1003.2.10.4 Exit illumination required
-I.B.C. 1003.2.12.1 Guards required to be 42" high when more than 30" of grade
-I.B.C. 1003.3.1.2 Exit doors must swing in the direction of travel
-I.B.C. 1003.2.2.5 Occupant load signs required
-I.B.C. 1003.3.1.4 Floor elevations must be the same on each side of doors
-I.B.C. 1003.3.1.9 Each door in a means of egress from an occupant load of 100 or more
shall be provided with panic hardware
-I.B.C. 1003.3.3.1 Existing stairs must be min. 36' wide
-I. B.C. 1003.3.3.2 Stairways shall have a min. head room of 80"
-I.B.C. 1003.3.3.3 as amended by state code section 1003.3.3.3 exception 5, Requires
stairs to have 8" max rise and 9" min. tread (existing private stairs)
-I.B.C. 2902.1 as amended by state code section 1305.2902 .2 Where plumbing fixtures are
required, separate facilities are required for each sex
j✓(�")G��� Z
. �
-I.B.C. table 2902.1 requires one drinking fountain
-Drinking fountain must be in compliance with state code section 1341.0446
-I.B.C. 1209 Requires toilet room floors to be a smooth, hard, nonabsorbent surface that
extends up the wall a min. of 6"
-I.B.C. 1209.2 Requires walls within 2 feet of urinals and water closets to be a smooth,
hard, nonabsorbent surface to a height of 4 feet above the floor
-State code section 1341.0422, subpart 2 item A Requires the accessible route to coincide
with the route for the general public. Proposed ramp location unacceptable
-Door hardware must be in compliance with section 1341.0442 subp. 9
-State code section 1341.0520 Requires counters to be accessible in compliance with
sectionl 341.0480
-Plumbing plans are required to be received by the state plbe code division
-Kitchen plans are required to be received by Hennepin county health dept.
-Plans are required to be submitted to the Met Council for SAC determination
�� �� � � z
� � �3 77 ��,�r��z� /��
, o�o �9a�
- y �
Date; 8-1-2005
Plan Review Notes
Address; 2377 Shadywood
Project; Finish shell into coffee shop
Architect; Architectural Alliance
Contractor; Verne V Olson Inc. �
Owner; Christine Valerius
Lessee; Caribou Coffee Co. Inc.
Inspector; Lyle Oman ��.
Occupancy Classification; I.B.C. section 303.1 A-2 Occupancy (inain Floor and luncl�/meeting
room on second floor)
I.B.C. section 304.1 B occupancy ( office portion of second floor )
Construction type; VB
Location on property; > 30' to property lines, no requirements
Allowable Height and floor area;
Height, 1 story Max- 2 story allowed with sprinkler -proposed 2 story
Basic allowable floor area - 9000 sq. ft. - 4256 proposed
Means of egress; Occupant load -Basement; 800 square feet clivided by 300 = 2 occupants
-1 S` floor
Kitchen - 513 divided by 200 = 2.5 occupants
Restaurant area- 565 divided by 15 = 37.6 occupants
Porch - 103.5 divided by 15 = 6.9 occupants
_�"a floor
Luncl�/ meeting room - 194 divided by 1�= 12 occupants
Office spaces-847 divided by 100 = 8.47 occupants
Egress width; table 10032.3
Basement- 2 times .15 = .3
15` floor - 40 times .15 = 6
2"d floor - 20.4 times .15 = 3
Proposed exceeds total required
Number of exits; table 1004.2.1 Group A <50 occupants req. 1 exits -4 proposed
Requirements;
-I.B.C. table 302.3.3 requires a two hour separation between group A2 and group B
occupancies - I.B.C. 302.3.3 allows a reduction of one hour when the building is provided
with a sprinkler system
-I.B.C. table 71�.2 i•cquires one hoily door assemblies in a one hour separatior.. Provide
plan on ho�v separation will be accomplished prior to construction
-I.B.C. 10032.12.1 Guards required to be 42" hiQh when more than 30" of arade
�, 03 3 7 7 ��d� ��
, ` . , �'o g9a�
-I.B.C. 1003.2.2.5 Occupant load signs required
-I.B.C. 1003.3.1.4 Floor elevations must be the same on each side of doors
-I. B.C. 1003.3.3.2 Stairways shall have a min. head room of 80"
-LB.C. 1208.1 Requires crawl spaces to have an access opening not less than 18" by 24"
-I.B.C. 2902.1 as amended by state code section 1305.2902 .2 Where plumbing fixtures are
required, separate facilities are required for each sex
-I.B.C. table 2902.1 requires one drinking fountain
-Drinlcing fountain must be in compliance with state code section 1341.0446 -
-I.B.C. 1209 Requires toilet room floors to be a smooth, hard, nonabsorbent surface that
extends up the wall a min. of 6"
-I.B.C. 1209.2 Requires walls within 2 feet of L�rinals and water closets to be a smooth,
hard, nonabsorbent surface to a height of 4 feet above the floor
- Door hardware must be in compliance with section 1341.0442 subp. 9
-State code section 1341.0520 Requires counters to be accessible in compliance with
section1341.0480 � p7
_ . (Z,ry�`' �.Z.'t'
��0.
Jul 26 05 07�32p Christine Valerius 952-472-3819 p.1 �D�C�_7(/,
� ���l-
� � � � � -���-�,� � 1 � ;
% � �
. --� w ��-�---_
���
v�,� �Q,�e (
. 1 I S --� ' �" �� �
. ��a��
�
. , ���. �
.
.
a`�
C
� �
�
� �� �
� '
, ��
�����
`� �� -
n
,
� `�" �'
� ��
�
�—
. � ���� � �
�� �