Loading...
HomeMy WebLinkAboutRe: plan review notes/2004 � . a. . , Date; 10-18-2004 Plan Review Notes Address; 2377 Shadywood Project; Addition-Remodel, Coffee Shop Architect; Martin Woody Contractor; Owner Owner; Christine Valerius Inspector; Lyle Oinan Occupancy Classification; I.B.C. section 303.1 A-2 Occupancy(main Floor) I.B.C. section 311.1 S-2 Occupancy (Second floor) Constniction type; VB Location on property; > 30' to property lines, no requirements Allowable Height and floor area; Height, 1 story Max- 2 story allowed with sprinkler -proposed 2 story Basic allowable floor area 9000 sq. ft. -4256 proposed Means of egress; Occupant load -Baseinent; 800 square feet divided by 300 = 2 occupants -15t floor 1440 divided by 15 = 96 occupants _2°a floor 1376 divided by 300 = 4 occupants Total 102 occupants Egress width; table 1003.2.3 Basement - 2 times .15 = .3 1'` floor - 96 times .15 = 14.4 2"d floor - 4.5 times .15 = .675 Total required= 15.375, Proposed 180 inches Number of exits; table 1004.2.1 Group A>50 occupants req. 2 exits -4 proposed Requirements; -I.B.C. 302.1.1, 302.33 and table 302.1.1 requires a one hour separation between group A2 and S2 -I.B.C. 1003.2.10.1 Exit signs required when more than 1 exit is required -I.B.C. 1003.2.10.4 Exit illumination required -I.B.C. 1003.2.12.1 Guards required to be 42" high when more than 30" of grade -I.B.C. 1003.3.1.2 Exit doors must swing in the direction of travel -I.B.C. 1003.2.2.5 Occupant load signs required -I.B.C. 1003.3.1.4 Floor elevations must be the same on each side of doors -I.B.C. 1003.3.1.9 Each door in a means of egress from an occupant load of 100 or more shall be provided with panic hardware -I.B.C. 1003.3.3.1 Existing stairs must be min. 36' wide -I. B.C. 1003.3.3.2 Stairways shall have a min. head room of 80" -I.B.C. 1003.3.3.3 as amended by state code section 1003.3.3.3 exception 5, Requires stairs to have 8" max rise and 9" min. tread (existing private stairs) -I.B.C. 2902.1 as amended by state code section 1305.2902 .2 Where plumbing fixtures are required, separate facilities are required for each sex j✓(�")G��� Z . � -I.B.C. table 2902.1 requires one drinking fountain -Drinking fountain must be in compliance with state code section 1341.0446 -I.B.C. 1209 Requires toilet room floors to be a smooth, hard, nonabsorbent surface that extends up the wall a min. of 6" -I.B.C. 1209.2 Requires walls within 2 feet of urinals and water closets to be a smooth, hard, nonabsorbent surface to a height of 4 feet above the floor -State code section 1341.0422, subpart 2 item A Requires the accessible route to coincide with the route for the general public. Proposed ramp location unacceptable -Door hardware must be in compliance with section 1341.0442 subp. 9 -State code section 1341.0520 Requires counters to be accessible in compliance with sectionl 341.0480 -Plumbing plans are required to be received by the state plbe code division -Kitchen plans are required to be received by Hennepin county health dept. -Plans are required to be submitted to the Met Council for SAC determination �� �� � � z � � �3 77 ��,�r��z� /�� , o�o �9a� - y � Date; 8-1-2005 Plan Review Notes Address; 2377 Shadywood Project; Finish shell into coffee shop Architect; Architectural Alliance Contractor; Verne V Olson Inc. � Owner; Christine Valerius Lessee; Caribou Coffee Co. Inc. Inspector; Lyle Oman ��. Occupancy Classification; I.B.C. section 303.1 A-2 Occupancy (inain Floor and luncl�/meeting room on second floor) I.B.C. section 304.1 B occupancy ( office portion of second floor ) Construction type; VB Location on property; > 30' to property lines, no requirements Allowable Height and floor area; Height, 1 story Max- 2 story allowed with sprinkler -proposed 2 story Basic allowable floor area - 9000 sq. ft. - 4256 proposed Means of egress; Occupant load -Basement; 800 square feet clivided by 300 = 2 occupants -1 S` floor Kitchen - 513 divided by 200 = 2.5 occupants Restaurant area- 565 divided by 15 = 37.6 occupants Porch - 103.5 divided by 15 = 6.9 occupants _�"a floor Luncl�/ meeting room - 194 divided by 1�= 12 occupants Office spaces-847 divided by 100 = 8.47 occupants Egress width; table 10032.3 Basement- 2 times .15 = .3 15` floor - 40 times .15 = 6 2"d floor - 20.4 times .15 = 3 Proposed exceeds total required Number of exits; table 1004.2.1 Group A <50 occupants req. 1 exits -4 proposed Requirements; -I.B.C. table 302.3.3 requires a two hour separation between group A2 and group B occupancies - I.B.C. 302.3.3 allows a reduction of one hour when the building is provided with a sprinkler system -I.B.C. table 71�.2 i•cquires one hoily door assemblies in a one hour separatior.. Provide plan on ho�v separation will be accomplished prior to construction -I.B.C. 10032.12.1 Guards required to be 42" hiQh when more than 30" of arade �, 03 3 7 7 ��d� �� , ` . , �'o g9a� -I.B.C. 1003.2.2.5 Occupant load signs required -I.B.C. 1003.3.1.4 Floor elevations must be the same on each side of doors -I. B.C. 1003.3.3.2 Stairways shall have a min. head room of 80" -LB.C. 1208.1 Requires crawl spaces to have an access opening not less than 18" by 24" -I.B.C. 2902.1 as amended by state code section 1305.2902 .2 Where plumbing fixtures are required, separate facilities are required for each sex -I.B.C. table 2902.1 requires one drinking fountain -Drinlcing fountain must be in compliance with state code section 1341.0446 - -I.B.C. 1209 Requires toilet room floors to be a smooth, hard, nonabsorbent surface that extends up the wall a min. of 6" -I.B.C. 1209.2 Requires walls within 2 feet of L�rinals and water closets to be a smooth, hard, nonabsorbent surface to a height of 4 feet above the floor - Door hardware must be in compliance with section 1341.0442 subp. 9 -State code section 1341.0520 Requires counters to be accessible in compliance with section1341.0480 � p7 _ . (Z,ry�`' �.Z.'t' ��0. Jul 26 05 07�32p Christine Valerius 952-472-3819 p.1 �D�C�_7(/, � ���l- � � � � � -���-�,� � 1 � ; % � � . --� w ��-�---_ ��� v�,� �Q,�e ( . 1 I S --� ' �" �� � . ��a�� � . , ���. � . . a`� C � � � � �� � � ' , �� ����� `� �� - n , � `�" �' � �� � �— . � ���� � � �� �