Loading...
HomeMy WebLinkAbout2001-P04615 - mechanical � '� PERMIT C I TY O F O RO N O Permit Number: 2750 Kelley Parkway - PO Box 66 P04615 Crystal Bay, Minnesota 55323 P2PCYllt Typ@: Mechanical Permits (952) 249-4600 Date Issued: l 1i9i2oo1 SITE ADDRESS: 2060 Shadywood Rd Wayzata, MN 55391 PID: 17-117-23-31-9999 DESCRIPTION: Proposed Use: Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: ����- FEE SUMMARY: Permit Fee: $ 414.14 Valuation: $ 33,131.00 State Surcharge Fee: $ 16.57 TOTAL FEE: $ 430.71 APPLICANT: Angell Aire Inc. OWNER: James Kline&Jacquelynn Kelly 12245 Nicollet Ave S. 2060 Shadywood Rd Burnsville, MN 55337 Wayzata,MN 55391 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. ;��,,E4� �-,'/�T C;�`�� �`=�� �= � A, ANT PERMITEE I NATURE � -�ISSUED BY SIGNATi.JRE `� � Copies: 1-File(Signitures Reguired), 1-Applicant, 1-Monthly Reports, 1-Assessing, 1-Finance Page 1 , � CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT BoY 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Desi�ns - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to rype, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: �C New Addition Repair Replace X' Residential Commercial JOB SITE: �a6o 5!����.u�>oc.� �2�� Zip: Owner's Name:�„ �'cn s�` Telephone Number: 9sa- 4yy-9��i Mailing Address: �soi� N�� 7 u��s�' City:�,�n����r�'�v Zip:��s-363�� Contractor'sName: iQivc�r,>!-�o;,e�� TelephoneNumber: �;sa-�y6-SaoU Mailing Address: ,�as�riv+L�`I��4���G��., City: ,�v��s��/!c> Zip: ss 33 7 SYSTEl�7 DESCRIPTION HEATING SYSTEMS Quantity: C3�r=ctic<<2,.,�,�►"a��,i�+lr'.r,�c<<¢�aN�BJ4s� 'r2�;�4n�f=/o�.� 8l�l5cn�ti Make: 3���cs,�' r�a,-�` z�r y�V�� Model: 3scvv,rv�YBo�ro 3s'�nr�4✓a4�c�� 8u�9�c1r4wlGa Fuel: yv y-t-} I1/,q�` lUlq�' Flue Size: �'�P�,� 3�P v� �'"O.v� Input BTUs: �o Goo �'G �ic� lc��� oaU Output BTUs: -�� QGG '7� GG!/ �'jG U�� -� CFM: i�oc� /60� COOLING SYSTEMS Quantity: �a� .�w.v, .v,��op,2 a��� ,y�lQSP.�I� Make: �,i�� �',@✓� _' Model: �/C, X� 6��/C�j X�� Tons: _� H. Power __ T . _.T�-,�_ . �.�. _ ; ; . . . . � , , . � �. .. , � _ . . . �� a FIREPLACES Gas factory fireplace Wood burning factory fireplace with flue . Wood Stove Wood stove with flue Brand Name Model No. �' ,�; ;r;- - � ; VENTILATION � y�.:, No. i Kitchen Exhaust .aC ducted recirculating � cfm ? �� �, No. Bath E�chaust (must be ducted outside) �,�QJ cfm � No. Other Fans: Locations cfm :� <�, ��� �R�i'1:�e�9�2 cx�hr.,�c ��-,� vPn,rv►u,r-��/oa.0 �Ci� G/�� � � FUEL STORAGE (MUST BE APPROV�D BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside a'. - LP Gas: gallons `"�° Other Gas opening '"" 4i J �R. .� � ,�;' PERMIT FEE CALCULATION �'�i l. 1.25% of Contract Price* or Minimum Fee ($35.00) 3� �3/ x .0125 $ y/�/, / 3 :l: (contract price) ,; 2. State Surchar�e. ** Add the State Building Code Division '" , S �,j Surcharge to each permit. x .0005 $ ;6, s� or $.50, whichever is greater (contract price) ��� ;�r 3. Posta�e and Handlin� (Only mail-in applications) $ 1.50 ; ;�<• 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ y��. '� �, �� * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted : ^ work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or �,'%` any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may ,� }`• request the submission of a signed copy of the actual contract. � <�' �;_. . ** The STATE SURCHARGE is .0005 of the contract price under�1,000,000 or $.50 - whichever is greater. _,;: For valuations over $1,000,000 call the Department of Inspectional Services for the price. ��f The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all � work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on thi pplication are complete, true and correct. ; �'; '� Applicant's Signature: Date: //- ��� }'` Approved By: Date: � � - � _ , Y � p AC.RasideMlal�L(gM Commerclal HVAG Lwds ProQam .;� Elifo Soflwaro Dwelop�rwM,Jnc. . ,Aa�Aire .: -: _ : ,: , , l�LLY/KL.INE ;egen,NqV 55123 ` - ` 05-30-2001 _ PaBe 2 System#1 Summary Loads Componerrt Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3D Window Double Pane Low Emit Wood Frame 1,332 44,239 0 63,380 63,380 11E Door Metal Urethane Core 42 734 0 188 188 12H Wali R-19+ 1/2"Gypsum Board(R-0.5) 3,575 19,734 0 5,060 5,060 15G Wall 5'or More Below Grade 8/12"BIk+R-11 1,621 6,413 0 0 0 16H Ceiling R-38 Insulation 3,318 7,937 0 3,796 3,796 201 Floor Over Open Crawl Carpet+R-19 448 1,978 0 323 323 21A Basemt Floor 2'or More Below Grade 2,870 6,337 0 0 0 Subtotals for stn�cture: 13,206 87,372 0 72,747 72,747 Active People: 4 0 920 1,200 2,120 Inactive People: 0 0 0 0 0 Appliance.s: 0 0 0 0 0 Lighting: 0 0 0 0 0 Ductwork: 0 431 0 378 378 Infiltration:Wirrter CFM:405.4, Summer CFM: 135.1 1,374 39,803 3,208 2,884 6,092 Verrtilation:Wirrter CFM: 135.1, Summer CFM: 135.1 0 13,267 3,209 2,884 6,093 Sensible Gain Total: 80,093 Temperature Swing Mumplier. X1.00 System Load Totals: 140,873 7,337 80,093 87,430 :: _._...',.,.� ���,���_,�..� v.: �ecCt.�`igu�e� ,_.�; .. .,_ ,,� .- .,�.�.,,,.� - _ _ . ,.. _ _ �_ � ._...�..... � :: �: . . , ..: , � � ; _.� ��� . Supply CFM: 3,617 CFM per square foot: 0.399 Square feet of room area: 9,058 Square feet per ton: 1,044.981 - ,.��-- , : �._ �" ` f k�,.,���u� .�.� � � �Et'��t3��°'" �..�,�:�.. .__... .__..�._.�. ��.�-'�r ._._ _.��-,. �.,;.�.�. k �:°, ,. '; . .��..�_., ;'. - Total heating required with outside air. 140,873 Btuh 140.873 MBH Total sensible gain: 80,093 Btuh 92 % Total laterrt gain: 7,337 Btuh 8 % Total cooling required with outside air. 87,430 Btuh 7.286 Tons(based on sensible+laterrt) 8.668 Tons(based on 77%sensible capacity) �e � �� �-� ���.. ��� �.�.�,�,�k;:�.�,.�s;�, � .,�:� : � � - ��:: ._. _. , �:: � � ��..�.�-���._��,��.. . :'.. �,, �> Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and laterrt loads. Wednesday,AAaY 30.2001 �� �� DATE TIME CITY OF ORONO CALLED IN INSPECTION NO C� � SCHEDULED ��7 �f.. � PERMIT NO. �� ��S COMPLETED � � f ,. ADDRESS �U(D C7 ���-cQ�L( G✓on� OWNER CONTR. �-t ����� ^ TELEPHONE N0. 7 ` ���7�'�r- �S� �S I ������1''%� � DESCRIPTION �ni� � C=((' �- fl�la:'(� CG..S '��'l�C r�,�� -{-�Sr � 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING Q 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y 03 INSULATIGN 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP O6 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT � 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL J 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL � OWNERICONTRACTOR TO MEET YOU:_YES�NO � COMMENTS: � a j ._7 ' � O �. � O � W � Q � 2 --- W � W � j � �VORK SATISFACTORY:PROCEED ❑ PROJECT COMPLEfE �� ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY �tj 0 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORECOVERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. p pHOTOTAKEN INSPECTOR WILL RETURN ❑CITATION ISSUED ❑STOP ORDER POSTED.CALL INSPECTOR ❑ INSPECTIONREQUIRED.CALLTOARRANGEACCESS. Call for the next inspection 24 hours in advance. (g52) 249-46�� OwnerlContractor on site: Inspector.�'�� v� Gti�I White Copyllnspector's File Canary CopylSite Notice � �e'-� DATE TIME CITY OF ORONO CALLED IN G$} INSPECTION TIC � c SCHEDULE�, a - - PERMIT N0. � � J COMPLETED � � a �D � C'' ' ADDRESS ���O OWNER � �—Q'n<il CONTR. TELEPHONE NO. ��� � �� � d � � DESCRIPTION � � 01 FOOTING 1 MECHANICAL RI 18 EXCAV/GRADING/FILLING Q 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y 03 INSULATIGN 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z 04 WALL B0. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PFOGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPL4INT � 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP ? 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL � 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL � OW NERICONTHACTOR TO MEET YOU YES_NO � COMMENTS: � W . � j j __ �C O � �. � O W � Q � Z W � W � � W�O�WORKSATISFACTORY:PROCEED ❑ PROJECTCOMPLEfE � �.: ��❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY � 0 CORRECT WORK,CALL FOR REINSPECTION TEMPORARY � BEFORE COVERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. p pHOTOTAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED ❑ INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952� 249-�6�0 OwnerlContra or on site: Inspector. White Copyflnspector's File Canary CopylSite Notice ✓ DATE TIME CITY OF ORONO CALLED IN INSPECTION TIC SCHEDULED — — � � PERMIT NO. l� COMPLETED /� - 10; 3d ADDRESS ��0� OWNER � CONTR. ��v TELEPHONE N . I S � 7�Co o�v� � DESCRIPTION � �� .Z`'�' �,�� � Ot FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING Q 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q OS FINAL 14 SEWER HOOK-UP 06 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT v 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL J 10 PLUMBING FINAL �( 36 FOUNDATION/REMOVAL � OWNERICONTRACTOR TO MEET YOU:_YES/`NO c�., COMMENTS: � W a J / � � � /�/�C !/` ei+�v r C c�I / .►_ � � � O � W � Q � 2 W � W � � d � �WORKSATISFACTORY:PROCEED ❑PROJECTCOMPLEfE W ❑CORRECT WOFiK 8 PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY 0 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORECOVERING PERMANENT ❑CORRECTUNSAFECONDITION WITHIN HOURS. p pHOTOTAKEN INSPECTOR WILL REfURN ❑CITATION ISSUED O STOP ORDEH POSTED.CALL INSPECTOR ❑INSPECTIONREQUIREO.CALLTOARRANGEACCESS. Catl for the next inspection 24 hours in advance. (g52) 249-46�0 OwnerlContractor on site: Inspector. 7�� , White Copyllnspector's File Canary Copy/Site Notice DATE TIME CITY OF ORONO CALLED IN INSPECTION 1T�I SCHEDULED �— �b� PERMIT NO. �/ � COMPLETED � � ADDRESS 0 b � OWNER ��-�r�IL.� CONTR. � TELEPHONE N0. I�� 7�� — � �� � � DESCRIPTION tt� 01 FOOTING 11 MECHANICAL R 18 EXCAV/GRADING/FILLING Q02 FRAMING ECHANICAL FINAL �l 19 LAKESHORE/WETLANDS y 03 INSULATION 4/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT `� 07 DEMO-FINAI 15 SEPTIC INSTALL. 22 fOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL J 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL � OWNER/CONTRAC 0 MEETYOU: YES_NO � /� � C MEN S�� �� ����Sf �"e � a � �7 � �. 0 a � 0 � W � Q � z W � W � � � � ❑WORKSATISFACTORY:PROCEED �ROJECTCOMPLETE W ORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORECOVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. p pHOTO TAKEN INSPECTOR W{LL FEfURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED ❑ INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Cail for the next inspection 24 hours in advance. (952� 249-4600 OwnerlContrac r on site: Inspector. White Copyllnspector's Ffle Canary Copy/Site Notfce