Loading...
HomeMy WebLinkAbout2003-P06915 - mechanical • fi�Y F R N PERMIT C' � � � � Permit Number: 2750 Kelley Parkway- PO Box 66 P06915 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Pernuts (952) 249-4600 Date Issued: ioi2oi2oo3 SITE ADDRESS: 2462 Sandstone La Long Lake,MN 55356 PID: 33-118-23-11-9925 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Pernuts Permit Sub-type(s): Mulriple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: PernutFee: $ gl•25 Valuation• $ 6,500.00 State Surcharge Fee: $ 3.25 TOTAL FEE: $ 84.50 APPLICANT: Plymouth Plumbing&Heating OWNER: Dahlstrom Development LLC 6909 Winnetka Avenue N 7745 Polaris Lane Brooklyn Park,MN 55428 Maple Grove,MN 55311 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. �_��G� APPLICANT PERMITEE SIGNATURE ISSUED BY SIGNATURE Couies: 1-File(SiQnitures Required), 1-Auulicant, 1-Monthlv Reuorts. 1-Assessin¢, 1-Finance Page 1 ""CITY OF ORONO A.PPLICATiON FOIt MECHANICAI,PERMIT Box 66 (2750 Kelley Parkway) ' Cryetsil Bay, MN 553�3 G��:Rr�,I. IN�O�tMATiO�t , l. Yau msy apply for incChar�icul permits by i;�ail Or IA PCfE0J1 di IhC Cliy UtflCCB. A�I1CAt10p5 Wl�l bC tevicwcil and a perc�it wil! be issucci within 2 working days. 2. Perrriit ciu�ls will be scnt by return mail after a review i6 completCd. P�RMITS ARE N�T VALID L1NTiL YOU RECPIV� A PER:viIT. �QRK MUS7 NOT a��IjV UNi'IL TH P IiMCC . IS P{a�T�U �N THE ]08 St� 3. Meehanical Deai�n9 - Camplete calculativns, details and specsfications are r�yuired fur �,cch heating, vot�tilation, humidificatian�irhtunidification, md air conditioning inatallation including heat loss��at gain calcula[i�m, dcsign tempetalvra�, ecluipcnent ratings and idantification aa to type, manufncturer ttnd ruodel. Data shall lx presencecl on form provided. ldcntification of and sptciticationa for water heating equipment shall alsfl bo providcd. 4. When any new cnnstruction or remvdelin� is involvcd, a stparate building pentut must t� obWined. 3. All work mus[ be donc in accordance with tbe Unifann Mec:hnnieal Codc/State Buildirlg Code rsquircmcnt�. 6. All wark must be ins�ec:tcd (rouYh•in and finaJ). Cai) 473-7357. 24-h�ur notic;e req¢arcd. 7. House Heatin� Tr,�t Record must tx aubruitted bcfore �na1. j��i� Campleta sll items on this applicatlan Co[npute the prnnit 1're. Sign sud date thC cenificatiost. 1NCOMYLii'tE APi'l.lC'ATIONS WIl.I. NOT aE PROCESSED. 1f you have questions, call 473-7357. Plcxsc check onc_ �� New _yr Additiun Rcpair ___ Rcpince � �Rcsidcntial . Comcu ial JOH SITE:y���.� � �1���-�- �?r�--- _ Zir: Qwner's Name: � a�, 'i�yv2�.�1c.�: _����� Telephone Number• Mai}�n� Addrr�ss: City: �Zip: _ _ Contractor's Name:�n�• _i,, ;� ll��� Tele�horn Number: -�j�'�..�%35'� Mallin� Addre.4s: ��i� �.vi�, , ._ C r-� City: �j�> Zlp; �- �-��- �,Y�.�.�'� P�CRIP'TIU;Y H�ATTNG SYSTEMS ��,��,ty: � � Make: �' �l/��� Modrl: �"-r. �����:l<'�;��, _ ._._ �uel: .�.�_.� __ , __ — Flue Sue: _��� � in�ut I3TUs: ��,.C;c;c� _.._. Qutput 9TUs: _ --- C�M; CQUi.ING SYSTEMS Qu�ntiiy: � Make: ��r 6 1 Y`u`� � � Model: lc�y� C'���_ —�.. ._ ___ � Tons: _ .��� H. Power ��r�-� � - • �'QQP �����i_,��J 1��T Woai stove with flue � _.___..__. woc�d �Umbii�ation or add-on _� Factory freplace with f7ue �__ Factory Fircplace {s) �__ Frecstanding � Masonry Wc�oci St�ve (s) Franklin, other Hranci Name Model No..�________, Mfgr's Min.,yCleaiances, side"� re�u , rnin. t7ue dia. �j�! ATION No. Kitchea L"•xhaust ducted recirculating _ cfm No. +�_ Batti Lxhaust {must be du�ted outside) �f�i Nc�. _�� Chher F�ns: Locatians � ` cfm �`IJ�L• �'�',S��AGE (MUS1' BF APPROVF?D BY FIRE MARS��AI�) Installation Removal _ _ Fuel nil: __` �a3lons _� und�rground _ inside outsidc ..__�. LP Gas: � Kallunti .Y.----� Other _�__...___ _____ Gas agening ` , � ��/�f--����.__[tv;`l, ?L,f f/'1��-E=� � �r<�.''���-,c�- PE����' �'���B1tC A l . 1.251 of '�jt�a�t Price"' or �'ee (�35.00) ��_.. x .0125 $ ;� � v� S� (contract price�� 2. 't t� Surc:ha�gcj ** Add che State Buildi g Caje Division Surchargc to each percnit. ��_����= _ x .00i)S $ � �� ar $.50, whichever is greater (concract pricc) 3. Po� a�t� and �1a� l� (O�IIy mail-in appticativns} $ � 4. 'I'UTAL PERMIT FFE (Add liries 1-�3 above) $ �j �/ � �� " C0IVTRACT PI{!C'�or 1OB COS7'mearua tbe actual or tatimated doilar nmc�unt charged for the permitted work i��cluding materials, labor, }�roftt, and othsr fizcd costs. it is thc amount to be thsu�ed to thc cw;romcr Pur the work eiune. [f any mnterial, �quipmcnt, labor, or installatic�n utC fue-r�iahed by the owner, tenanl ot tiny�thtr Qutty the rcasnnahle niarket vxlue of such items must 6e added to the estimatad cost �r coiitr�ct price for ptrenit irc purposes. ln th4 event chut there is a dis�+utc on thc amount of th�job cost, ihe Ctty may requ�st the submissiva of a si�nM topy of the actoal couiracc. *'' ?he STA?E SL'RCHARGE is .(�US uf the eontract price undcr �1,000,0()0 or 5.5c) - whichcvrr is greator. Fsit v�luations ovrr fi1,00p,Q00 �all the Departrnent of Ineptctiva�l Services for tht price. The undersigned hercby applies to the City for issuanCe of a Mechani�ai Pennit, agrces to c�u all work iti Stri�:t accordaru;e with the ordinant:cs of the City anci the regulations of the Minnesota Statc IIui)di�g Code, �uui certifies that all st�tements made on this application are rvmplete, tnie and correct, Applicant's Signature: _ ��'� �-� , w,� Date: �L� -`� � � Approvec! BY: Datt: RHVAC-Residential&Light Commercial HVAC Loads Elite Software Development,lnc. • Plymouth Plumbing`&Heating John Terrance Homes-2460 Sandstone Ln Brookl n Center, MN 55428-1662 Pa e 1 Total Building Summary Loads ' Component Area Sen Lat Sen Total Descri tion Quan Loss Gain Gain Gain 3D Window Double Pane Low Emit Wood Frame 199 5,891 0 3,582 3,582 11C Door Metal Polystyrene Core 42 1,619 0 367 367 121 Wall R-19 + 1/2"Asphlt Board(R-1.3) 2216 9,995 0 2,266 2,266 15G Wall 5' or More Below Grade 8/12" BIk+R-11 739 2,605 0 0 0 161 Ceiling R-44 Insulation 1901 3,585 0 1,705 1,705 21A Basemt Floor 2' or More Below Grade 1896 3,731 0 0 0 Subtotals for structure: 27,426 0 7,920 7,920 People: 6 1,380 1,800 3,180 Equipment: 300 1,200 1,500 i Lighting: 0 0 0 � Ductwork: 6,567 0 0 0 Infiltration: Winter CFM: 161, Summer CFM: 215 14,123 4,531 3,445 7,976 Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336 Sensible Gain Total: � 15,806 Temperature Swing Multiplier: X 1.15 Total Building Load Totals: 55,992 8,106 18,177 26,283 Check Fi ures Total Building Supply CFM: 902 (1.7 AC/hr) CFM Per Square ft.: 0.237 Square ft. of Room Area: 3,797 Square ft. Per Ton: 1,293 Buildin Loads Total Heating Required With Outside Air: 55,992 Btuh 55.992 MBH Total Sensible Gain: 18,177 Btuh 69 % � Total Latent Gain: 8,106 Btuh 31 % Total Cooling Required With Outside Air: 26,283 Btuh 2.19 Tons (Based On Sensible+ Latent) 2.94 Tons (Based On 77% Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\John Terrance Homes -2460 Sandstone Ln -Orono.rhv Tuesday, September 23, 2003, 11:38 AM � �� � ��! � D�,Tf � TIME CIN OF ORONO CALLED IN �� d INSPECTION NOTIC scHEou�Eo �v 0 � PERMIT NO. ' ����?�I� COMPLETED ADDRESS ��� �' ��-�""���n� �A.✓• OWNER CONTR. ����,C�l%t �/t,c� TELEPHONE NO. " �� � � � � � � DESCRIPTION 1'7 I O ti� � �� tL 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING � 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y Q 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAI Z 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q OS FINAL 14 SEWER HOOK-UP 06 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT `� 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL J 10 PLUMBING FINAL � ' 36 FOUNDATION/REMOVAL � OWNERICONTRACTOH TO MEET YOU:�YES_NO � COMMENTS: � W a � � O �. � O � W � Q � 2 W � �u � � J d � WORKSATISFACTORY:PROCEED ❑ PROJECTCOMPLETE W ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY 0 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORECOVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. O PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED O INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-46�� OwnerlContra or�site: Inspector. White Copyllnspector s Ffle Canary CopylSfte Notice