HomeMy WebLinkAbout2005-P08425 - mechanical s ' PERMIT CITY OF ORONO Permit Number: 2750 Kelley Parkway- PO Box 66 Posa2s Crystal Bay, Minnesota 55323 Permit Type: Mechanical Pernuts (952) 249-4600 Date Issued: 2igi2oos SITE ADDRESS: 721 Sandstone Cir L.ong Lake,MN 55356 PID: 33-118-23-11-0048 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Pemuts Pernut Sub-type(s): Mulriple Mechanical Items DETAILS: Approved per resolution#: Separate pernuts required: NOTICES/REMARKS: FEE SUMMARY: Pernut Fee: $ 106.25 Valuation: $ 8,500.00 State Surcharge Fee: $ 4.25 TOTAL FEE: $ 110.50 APPLICANT: Plymouth Plumbing&Heating OWNER: John Terrance Homes,LLC 12270 43rd Street NE 2500 Kelley Parkway St.Micheal,MN 55376 Long Lake,MN 55356 THE UNDERSIGNED HEREBY REQUESf S PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICf COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. APPLI ANT PERMITEE SIGNATURE I SUED BY SIGNATURE Conies: 1-File(SiQnitures Required), 1-Annlicant, 1-Monthlv Renorts, 1-Assessine, 1-Finance Page 1 r , CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 _ GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECENE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Desiens - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. Whe�i any new construction or remc�eling is involved, a separate bui.:iing permit must�e a�tained. 5. All work must be done in accordance with the Uni:orm Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before fmal. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, ca11249-4600. Please check one: ,✓ New Addition Repair Replace ✓ Residential Commercial JOB SITE: � t - ZiP• _ _ �. Owner's Nam-e�o�h T"-e�� ,,,_� C�S. Telephone Number: � Mailing Address: . - ,__ _ . - _ ----- City: ,: _, ,Zi� __ _ . _ _ _ �PLYINOU'�t PLI�MBING INC. ' Contractor's Nam�:_ � Telephone Numbe��f' ��w 3 S�'y�.,r/oc� 12270 43rd Str�et N.�. ^ '�- Mailing Address:_ _' ,��.,C,,,�,�;.,1 �aN�.53T�-�77I . - ity: ��ip;:- . �W� '�-` - :;��x SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: Make: .2 i'lo Model: G�3U F 3� b'Io Fuel: Flue Size: ' Input BTUs: �o+ obo Output BTUs: (�d� CFM: COOLING SYSTEMS Quantity: � Make: ��-e v►�c�C - _ Model: 1 O �CGb3��' Tons:` ' T a �f a H. Power �f - _ _ _ ______ _ _____--------- ---__ _ ____--__ _-- 3 �'rr`��'�'� 1/.��n� r � � - , * � � � � FIREPLACES . ,I n�, � Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. � Kitchen Exhaust 1 ducted recirculating cfin No. .3 Bath Exhaust (must be ducted outside) cfin No. Other Fans: Locations �� FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee ($35.00) �5dv � x .0125 $ (contract'price) 2. State Surcharge. ** Add the State Building.Code Division � Surcharge to each permit: � $b o �` : x .0005 : $ - , . � or $.50, whichever is greater (contracc price) � � . . . . �,.,....i•wr M�aNaiseni isr� . . . . 3. Postage and Handlin� (Only mail-in applications) $ 1.50 _ 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ * CONTRACT PRICE or JOB COST means the actual or estimated dollaz amount charged for the permitted • work including materials,labor,profit,and otiier fixed costs. It is the amount ta 1ie charged to the customer for the work done. If any material, equipment;labor,or installation aze furnished by the owner, fenant or any other party the reasonable market value of such items must be added to.the estimated cost or:contract - price for permit fee purposes: In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual conttact. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50-whichever is greater. � For valuations over $1,000,000 call the Department of inspectional Services for the price. � The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance witti the ordinances of the City and the regulations of the Muuiesota " �... : , <�.., " ` �"-"State�Building Code; anc�eertifies•that all statements:made on tlus application are complete, true . . (._. �...rl.,nr.r, N.•Y�T and correct. : : - �:: -� .. �3:s � '�� ��. � � � ; . .. . . . � �....�;:'e� _ v'S YY:c:�. __ ' Applicant's Signa e: '�=� ` _ . ., �Date: ' ''.�_ APProved By: Date: i r ', • � ' . fi. TotalBuildin Summa Loads 3D Window Double Pane Low Emit Wood Frame 175 5,180 0 3,150 3,150 11 C Door Metal Polystyrene Core 42 1,618 0 368 368 121 Wall R-19 + 1/2"Asphlt Board(R-1.3) 2532 11,420 0 2,590 2,590 15G Wall 5'or More Below Grade 8/12" BIk+R-11 299 1,055 0 0 0 16f Ceiling R-44 Insulation 1043 1,967 0 936 936 19J Floor Over BasemenUEncl Crawl Carpet+ R-30 563 808 0 0 0 21A Basemt Floor 2'or More Below Grade 480 945 0 0 0 - -- - -- --- -.._ _ Subtotals for structure: 22,993 .0 7,044 7,044 People: 6 1,380 1,800 3,180 Equipment: 300 1,200 1,500 Lighting: 0 0 0 Ducfinrork: 2,799 0 0 0 Infiltration: Winter CFM: 108, Summer CFM: 144 9,438 3,028 2,302 5,330 Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336 Sensible Gain Total: 13,787 Temperature Swin�Multiplier__ _ ___ __ ______ X 1.15 Total Building Load Totals: 43,106 6,603 15,855 22,458 Total Building Supply CFM: 665 (1.9 AC/hr) CFM Per Square ft.: 0.259 Square ft. of Room Area: 2,566 Square ft. Per Ton: 1,073 Total Heating Required With OutsideAir: 43,106 Btuh 43.106 MBH Total Sensible Gain: 15,855 Btuh 71 % Total Latent Gain: 6,603 Btuh 29 % Total Cooling Required With Outside Air: 22,458 Btuh 1.87 Tons (Based On Sensible+ Latent) 2.39 Tons (Based On 77% Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\John Terrance Homes-3 unit inside unit.rhv Friday, September 05, 2003, 8:52 AM