HomeMy WebLinkAbout2004-P07848 - mechanical - -�
PERMIT
CITY OF ORONO
2750 Kelley Parkway- PO Box 66 Permit Number: Po�s4s
Crystal Bay, Minnesota 55323 Permit Type: Me�ha��al pe�ts
(952) 249-4600 Date Issued: s�ig�2ooa
SITE ADDRESS: 72o Sandstone Cir
I.ong Lake,MN 55356
PID: 33-118-23-11-0052
DESCRIPTION:
Proposed Use: Residential
Permit Class: General
Permit Type: Mechanical Permits Permit Sub-rype(s): Mulriple Mechanical Items
DETAILS:
Approved per resolution#:
Separate pernuts required:
NOTICES/REMARKS:
FEE SUMMARY: Pernut Fee: $ 102.50 Valuation: $ 8,200.00
State Surcharge Fee: $ 4.10
TOTAL FEE: $ 106.60
APPLICANT: Plymouth Plumbing&Heating OWNER: Dahlstrom Development LLC
12270 43rd Street NE 7745 Polaris Lane
St. Micheal,MN 55376 Maple Grove,MN 55311
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED
AND AGREES TO DO ALL WORK IN SI'RICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF
MINNESOTA BUILDING CODE REQUIREMENTS.
I,�'/ -
'4r�� ��_�., � ��--- ��)
APPLICANT PERMITEE SIGNATURE ISSUED BY SIGNATURE
Conies: 1-File(SiQnitures Required), 1-Applicant, 1-Monthlv Reports. 1-Assessine, 1-Finance Page 1
�b�7 ��'
t.
, CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT
Box 66 (2750 Kelley Parkway)
Crystal Bay, 1VIN 55323
GENERAL INFORMATION
1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be
reviewed and a permit will be issued within 2 working days.
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL
YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON
THE JOB SITE.
3. Mechanical Desi�ns - Complete calculations, details and specifications are required for each heating,
ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain
calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model.
Data shall be presented on form provided. Identification of and specifications for water heating equipment
shall also be provided.
4. Whe�i any new construction or remc�eling is involved, a separate bui:�ing permit must be o'vtained.
5. All work must be done in accordance with the UniAorm Mechanical Code/State Building Co�e requirements.
6. All work must be inspected(rough-in and fmal). Call 249-4600. 24-hour notice required.
7. House Heating Test Record must be submitted before final.
Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification.
INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600.
Please check one: �ew Addition Repair Replace
Residential Commercial
JOB SITE: U � " � �_ Zip:
Owner's Name: a Telephone Number:
Mailing Address: City: Zi�:
Contractor's Name: ������L�MBING INC. Telephone Numbe��'�� ���.�/cav
12270 43rd Street N.E.
Mailing Address:_ - ,��.z-►►,�:x�a f�N �5376-977I — ity: �ip:- . ��� • ' ,°
��;�-%�x
SYSTEM DESCRIPTION
HEATING SYSTEMS
Quantity:
Make:
Model: �� � � ��-;
Fuel: Le
Flue Size: l� �
Input BTUs: U '
Output BTUs: �-�'
CFM:
COOLING SYSTEMS
Quantity: (J�
Make:
Model: /C� -�-:3-�
Tons: �
H. Power
.
FIREPLACES I �� �✓ //�-- �� �'�`�'t� � ,^ � .
Gas f&�tor fire lace
�
Y P
Wood burning factory fireplace with flue
Wood Stove
Wood stove with flue
Brand Name Model No.
VENTILATION
No. Kitchen Exhaust ducted recirculating cfm
No. � Bath E�aust (must be ducted outside) ��> cfm
No. �_ Other Fans: Locations � cfin
l ,�J��I�.P G/,>�r�' �. "� �-�y�5'�n�.�z.�
FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL)
Installation Removal
Fuel oil: gallons underground inside outside
LP Gas: gallons
Other Gas opening
PER�VIIT FEE CALCULATION
1. 1.25% of Contract Price* or Minimum Fee ($35.00)
��Ci� x .0125 $
(co tract price)
2. State Surcharge. ** Add the State Build'n Code Div�sian �
Surcharge to each permit. �����` x .0005 $
or $.50, whichever is greater (contract price)
...• ,..r.+n•.w;..�c.r,s.o...♦
3. Postage and Handlin� (Only mail-in applications) $ 1.50
4. TOTAL PERMIT FEE (Add lines 1-3 above) $
* CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted
work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer
for the work done. If any material, equipment, labor, or uistallation are furnished by the owner, tenant or
any other party the reasonable market value of such items must be added to the estimated cost or contract
price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may
request the submission of a signed copy of the actual contract.
** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 - whichever is greater.
For valuations over $1,000,000 call the Department of Inspectional Services for the price.
� The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all
work in strict accordance with the ordinances of the City and the regulations of the Minnesota
State�Building Code, and certifies that all statements made on this application are complete, true
and correct.
Applicant's Signature: � Date: � ���^
Approved By: Date:
� . -i
-ri -
�
Tota;l Buildin Summa Loads
3D Window Double Pane Low Emit Wood Frame 278 8,230 0 5,004 5,004
11 C Door Metal Polystyrene Core 42 1,618 0 368 368
121 Wall R-19+ 1/2"Asphlt Board(R-1.3) 1945 8,773 0 1,990 1,990
15G Wall 5'or More Below Grade 8/12" BIk+R-11 715 2,520 0 0 0
161 Ceiling R-44 Insulation 1071 2,020 0 961 961
19J Floor Over BasemenUEncl Crawl Carpet+ R-30 618 887 0 0 0
21A Basemt Floor 2'or More Below Grade 420 827 0 0 0
._ __ ___ _ ._ __ __ -- -___ __- __ . .. _ __ __---_ _... ____- --- - -
Subtotals for structure: 24,875 0 8,323 8,323
People: 6 1,380 1,800 3,1$0
Equipment: 300 1,200 1,500
Lighting: 0 0 0
Ductwork: 2,388 0 0 0
Infiltration: Winter CFM: 108, Summer CFM: 144 9,437 3,029 2,301 5,330
Ventilation:Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336
____ _ _...___ _____. ---- ---.__.__._ .. __...__ _
Sensible Gain Total: 15,065
Temperature Swinc�Multiplier. ___ __ _______.,____X 1.15
Total Building Load Totals: � 44,576 6,604 17,325 23,929
Total Building Supply CFM: 734 (2.0 AC/hr) CFM Per Square ft.: 0.287
Square ft. of Room Area: 2,562 Square ft. Per Ton: 1,071
Total Heating Required With Outside Air: 44,576 Btuh 44.576 MBH
Total Sensible Gain: 17,325 Btuh 72 %
Total Latent Gain: 6,604 Btuh 28 %
Total Cooling Required With Outside Air: 23,929 Btuh 1.99 Tons(Based On Sensible+ Latent)
2.39 Tons(Based On 77% Sensible Capacity)
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Elite\Rhvacw\Projects\John Terrance Homes-3 unit outside unit.rhv Tuesday, September 16, 2003, 10:19 AM