HomeMy WebLinkAbout2005-P08427 - mechanical .� PERMIT
CI�Y OF ORONO Permit Number:
2750 Kelley Parkway- PO Box 66 P08427
Crystal Bay, Minnesota 55323 Permit Type: Me�n�,i�ai Permits
(952) 249-4600 Date Issued: 2isi2oos
SITE ADDRESS: 717 Sandstone Cir
L.ong Lake,MN 55356
PID: 33-118-23-11-0046
DESCRIPTION:
Proposed Use: Residenrial
Perxnit Class: General
Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items
DETAILS:
Approved per resolution#:
Separate permits required:
NOTICES/REMARKS:
FEE SUMMARY: Pernut Fee: $ 106.25 Valuation• $ 8,500.00
State Surcharge Fee: $ 4.25
TOTAL FEE: $ 110.50
APPLICANT: Plymouth Plumbing&Heating OWNER' John Terrance Homes,LLC
12270 43rd Street NE � 2500 Kelley Parkway
St.Micheal,MN 55376 Long Lake,MN 55356
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED
AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF
MINNESOTA BUILDING CODE REQUIREMENTS.
APPLICANT PERMITEE SIGNATURE ED BY SIGNATURE
Couies: 1-File(SiQnitures Required), 1-Anplicant, 1-Monthlv Revorts, 1-Assessine, 1-Finance Page 1
.
�
i `
CITY OF ORONO APPLICATION FOR MECHAlVICAL PERMIT
Box 66 (2750 Kelley Parkway)
Crystal Bay, 1VIN 55323
GENERAL INFORMATION
1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be
reviewed and a permit will be issued within 2 working days.
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL
YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON
THE JOB SITE.
3. Mechanical DesiQns - Complete calculations, details and specifications are required for each heating,
ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain
calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model.
Data shall be presented on form provided. Identification of and specifications for water heating equipment
shall also be provided.
4. Wheii any new construction or remcdeting is involved, a separate bui:�ing permit must be o:;tained.
5. All work must be done in accordance with the Uni`orm Mechanical Code/State Building Code requirements.
6. All work must be inspected(rough-in and final). Call 249-4600. 24-hour notice required.
7. House Heating Test Record must be submitted before final.
Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification.
INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600.
Please check one: ✓ New Addition Repair Replace
✓ Residential Commercial .
JOB SITE: `f ��J ��'��',� � Zip:
Owner's Name: o�n�.Tr21��• l�. Telephone Number:
Mailing Address: City: Zi�:
, — pl.YM0U�41 PLBMBING INC. - � c /
Contractor s Nam�:. �Telephone Numbe��f'7�� ,�,�'��.� c�v
12210 43rd Street N.E.
Mailing Address:_ ' ,��t-►,,�.,,,,.,�1 ��I 55376-977t _ — rty �ip:- . ��, ,�=;x
SYSTEM DESCRIPTION
HEATING SYSTEMS
Quantity:
Make: •e r10 _
Model: G�3U F 3c. b'�o
Fuel: 4-�-.s
Flue Size: �'
Input BTUs: �o� o00
Output BTUs: �_vo�
CFM:
COOLING SYSTEMS
Quantity: ��
Make: �,_.-2 t�►nsyC
ModeL• �b �A-CGb3��
Tons: ' r� 'f d
H. Power '/3
/�`�C�� 1/�YJ f'vtiu/
t � P
.
., . �
�
S � �
FIREPLACES I I� n�, '�
Gas factory fireplace
�
Wood burning factory fireplace with flue
Wood Stove
Wood stove with flue
Brand Name Model No.
VENTILATION
No. � Kitchen E�aust I ducted recirculating cfm
No. .3 Bath E7chaust (must be ducted outside) cfm
No. Other Fans: Locations cfin
FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL)
Installation Removal
Fuel oil: gallons underground inside outside
LP Gas: gallons
Other Gas opening
PERIVIIT FEE CALCULATION
1. 1.25% of Contract Price* or Minimum Fee ($35.00)
�sd� -- x .0125 $
(contract price)
2. State Surchar�e. ** Add the State Building.Code,Division *
Surcharge to each permit. � �j b c� —' x .0005 $
or $.50, whichever is greater (contract price)
w.....�f�'�M��Mr tH[Mn11�M��r�
3. Posta�e and Handling (Only mail-in applications) $ 1.50
4. TOTAL PERMIT FEE (Add lines 1-3 above) $
* CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted
work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer
for the work done. If any material, equipment, labor, or uistallation are fumished by the owner, tenant or
any other party the reasonable market value of such items must be added to the estimated cost or contract
price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may
request the submission of a signed copy of the actual contract.
** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 -whichever is greater.
For valuations over $1,000,000 call the Department of Inspectional Services for the price.
� The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all
work in strict accordance with the ordinances of the City and the regulations of the Minnesota
State�Building Code, and certifies that all statements made on this application are complete, true
and correct.
,� ,� _ ,.:
Applicant's Signa e: Date: �_�_�–
Approved By: Date:
�
.
TotalBuildin Summa Loads
3D Window Double Pane Low Emit Wood Frame 175 5,180 0 3,150 3,150
11 C Door Metal Polystyrene Core 42 1,618 0 368 368
121 Wall R-19+ 1/2"Asphlt Board(R-1.3) 2532 11,420 0 2,590 2,590
15G Wall 5'or More Below Grade 8/12" BIk+R-11 299 1,055 0 0 0
161 Ceiling R-44 Insulation 1043 1,967 0 936 936
19J Floor Over BasemenUEncl Crawl Carpet+ R-30 563 808 0 0 0
21A Basemt Floor 2'or More Below Grade 480 945 0 0 0
_ _ _ _.. ___._ . _...__---._ _ - ---- ---_.-- ___. --..----- - --_. ..
Subtotals for structure: 22,993 .0 7,044 7,044
People: 6 1,380 1,800 3,180
Equipment: 300 1,200 1,500
Lighting: 0 0 0
Ductwork: 2,799 0 0 0
Infiltration: Winter CFM: 108, Summer CFM: 144 9,438 3,028 2,302 5,330
Ventilation: Winter CFM: 90, Summer CFM: 90 _ _ ___ _ ____7,876 ____ 9,895_ 1,441 3,336
_- _._... _ --_._ . ._________ -- __- - --.. .
Sensible Gain Total: 13,787
_Temperatu_re Swin�Mul�lier:__ _ X 1.15
---... ...._______.--- -----
Total Building Load Totals: 43,106 6,603 15,855 22,458
Total Building Supply CFM: 665 (1.9 AC/hr) CFM Per Square ft.: 0.259
Square ft. of Room Area: 2,566 Square ft. Per Ton: 1,073
Total Heating Required With OutsideAir: 43,106 Btuh 43.106 MBH
Total Sensible Gain: 15,855 Btuh 71 %
Total Latent Gain: 6,603 Btuh 29 %
Total Cooling Required With Outside Air: 22,458 Btuh 1.87 Tons(Based On Sensible+ Latent)
2.39 Tons(Based On 77% Sensible Capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.