Loading...
HomeMy WebLinkAbout2004-P07852 - mechanical � � PERMIT CITY OF ORONO Permit ►vumber: 2750 Kelley Parkway - PO Box 66 Po�ss2 Crystal Bay, Minnesota 55323 Pet-mit Type: Mechanical Pernuts (952) 249-4600 Date Issued: siisi2ooa SITE ADDRESS: 716 Sandstone Cir I.ong Lake,MN 55356 P I D: 3 3-118-23-11-0050 DESCRI PTION: Proposed Use: Residential Permit Class: General Pernut Type: Mechanical Pernuts Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate pernuts required: NOTICES/REMARKS: FEE SUMMARY: Permit Fee: $ 102.50 Valuation: $ 8,200.00 State Surcharge Fee: $ 4.10 TOTAL FEE: $ 106.60 APPLICANT: Plymouth Plumbing&Heating OWNER: Dahlstrom Development LLC 12270 43rd Street NE 7745 Polaris Lane St.Micheal,MN 55376 Maple Grove,MN 55311 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. i i� - �� `L"b,� ` ,�L�" � APPLICANT PERMITEE SIGNATURE ISSUED BY SIGNATURE Conies: 1-File(SiQnitures Reouired), 1-Apnlicant, 1-Monthlv Reports, 1-Assessine, 1-Finance Page 1 . � ,�� ���� .. � CITY�F ORONO APPLICATION FOR MECHAIVICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, 1VIN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by retum mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Desiens - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remcjeling is involved, a separate bui:�iing permit must�e o:;tained. 5. All work must be done in accordance with the Uni�orm Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: �/jiew Addition Repair Replace � Resid�al Commercial JOB SITE• �/�i> ��t��,Lk�",�;. ��i�,L� Zip: Owner's Name: ►o� j—c���� h�ii� Telephone Number: Mailing Address: City: Zi�: Contractor's Name:. ������LI�MBiNG INC. " Telephone Numbe��'��_ r,,�`��,,�/c�u Mailing Address: 122�a 43rd Street N.E. _�ty: �ip:_ �. ,��� - � ��z�,��� �uN�5315-917I SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: � � Make: -Q Model: �� ��U Fuel: Flue Size: �` Input BTUs: ' (� - U Output BTUs: CFM: COOLING SYSTEMS Quantity: ��� Make: �_--�v�,Y�.,.� Model: j � �-E.:.C,ol`� Tons: �'�_ H. Power �+ . , � � jnQ � ����.� �� � --� �` FIREPLACE5 �' ' �t Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen E�aust ducted recirculating cfm No. � Bath E�aust (must be ducted outside) 5��' cfm No. f Other Ra�s: Locations � ' �-�r ���������� l 17� �-v� //���f '� FUEL STORAGE (MUS�BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERibIIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee 35.00 - ��� -�—x .0125 $ (contract price) 2. State Surcharge. ** Add the State Building.Code,Division Surcharge to each permit. ,f� ��� �-` x .0005 $ or $.50, whichever is greater (contract price) ,,. ..,...«.w�.w.,..n�...♦ 3. Posta�e and Handlin� (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or uistallation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 - whichever is greater. For valuations over$1,000,000 call the Department of Inspectional Services for the price. � The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State�Building Code, and certifies that all statements made on this application are complete, true and correct. A licant's Sianature: �� Date: � ` � rr � Approved By: Date: + � � w M � /• � Hr a ,, , � . Tot� Building Summary Loads 3D Window Double Pane Low Emit Wood Frame 278 8,230 0 5,004 5,004 11C Door Metal Polystyrene Core 42 1,618 0 368 368 121 Wall R-19+ 1/2"Asphlt Board(R-1.3) 1945 8,773 0 1,990 1,990 15G Wall 5'or More Below Grade 8/12" BIk+R-11 , 715 2,520 0 0 0 161 Ceiling R-44 Insulation 1071 2,020 0 961 961 19J Floor Over BasemenUEncl Crawl Carpet+ R-30 618 887 0 0 0 21A Basemt Floor 2' or More Below Grade 420 827 0 0 0 Subtotals for structure: 24,875 0 8,323 8,323 People: 6 1,380 1,800 3,180 Equipment: 300 1,200 1,500 Lighting: 0 0 0 Ductwork: 2,388 0 0 0 Infiltration: Winter CFM: 108, Summer CFM: 144 9,437 3,029 2,301 5,330 Ventilation:WinterCFM: 90, SummerCFM: 90 7,876 1,895 1,441 3,336 Sensible Gain Total: 15,065 Tem�erature_Swin�Multiplier; _----_---------- ---_-----------X 1.15-----._..__.__... Total Building Load Totals: 44,576 6,604 17,325 23,929 Total Building Supply CFM: 734 (2.0 AC/hr) CFM Per Square ft.: 0.287 Square ft. of Room Area: 2,562 Square ft. Per Ton: 1,071 Total Heating Required With Outside Air: 44,576 Btuh 44.576 MBH Total Sensible Gain: 17,325 Btuh 72 % Total Latent Gain: 6,604 Btuh 28 °/a Total Cooling Required With Outside Air: 23,929 Btuh 1.99 Tons (Based On Sensible+ Latent) 2.39 Tons (Based On 77% Sensible Capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\John Terrance Homes-3 unit outside unit.rhv Tuesday, September 16, 2003, 10:19 AM