Loading...
HomeMy WebLinkAbout2004-P07185 - mechanical CITY OF ORONO PERMIT 2750 Kelley Parkway - PO Box 66 Permit Number: Po�iss Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 249-4600 Date Issued: i�26�2004 SITE ADDRESS: 659 Sandstone Cr Long Lake,MN 55356 PID: 33-118-23-11-9931 DESCRIPTION: Proposed Use: Residential Pernut Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: FEE SUMMARY: Pernut Fee: $ 95.00 Valuation: $ 7,600.00 State Surcharge Fee: $ 3.80 Misc.Fee: $ 1.50 TOTAL FEE: $ 100.30 APPLICANT: Plymouth Plumbing&Heating OWNER: Dahlstrom Development LLC 12270 43rd Street NE 7745 Polaris Lane St. Micheal,MN 55376 Maple Grove,MN 55311 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN SI'RICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. �yy� �l/r� E���-�� APPLICANTPERM[TEESIGNATURE / SUEDBYSIGNATURE Copies: 1-File(SiQnitures Required), 1-Applicant, 1-Monthlv Reports, 1-Assessin�, 1-Finance Page 1 ` CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permi[will be issued within 2 working days. 2. Permit cards will be sent by retum mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical DesiQns - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identificat:on of and specifications for water heating equipment shall also be provided. 4. Whe;.i any new construction or remcdeling is involved, a.eparate bui:�iing permit must be outained. 5. All work must be done in accordance with the Un::orm Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before fmal. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600. Please check one: �ew Addition Repair Replace �Resi�tial Commercial T— JOB s�TE: �iS> ���� S a�Jw-��.�'i-</� z�p: Owner's Name: ��j"�..�.yr�;.L c,e Telephone Number: Mailing Address: _ City: Zip: '-`�pl.YMOUTH PlUM61NG INC. Contractor's Name:. Telephone Numbe��.�;� ,!��.,�ioc� 12210 43rd Street N.E. Mailing Address:_ - �S�.r,,<<,,:,,,i �N �5316-977T _ ity:�-�-----�-�1P:_ . � . . � .,� ;-�:� SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: /�,� Make: �.-{'!�_ _ Model: C'S,j,r��'/3 �J`�L� Fuel: 'c�.5 Flue Size: �' Input BTUs: �� C'c�' Output BTUs: CFM: COOLING SYSTEMS Quantity: (�\ Make: � ModeL• c7 C�C: � Tons: �" H. Power FIREPLACES � Gas factory fireplace Wood burning factory fireplace with flue Wood Stove Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen Exhaust ducted recirculating cfm No. _� Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations �� FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25% of Contract Price* or Minimum Fee 35.00 �, � C�G ---- X .oi2s � `� S ' (contract price) 2. State Surchar�e. ** Add the State Building Code Division ��� Surcharge to each permit. x .0005 $ 3- or $.50, whichever is greater (contract price) . 3. Postage and Handlin� (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ ,/�O • `'. * CONTRACT PI�ICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or u�stallation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 -whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. � The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: Date: ) a/ �..�.-- Approved By: Date: �otal Building Summary Loads 3D Window Double Pane Low Emit Wood Frame 175 5,180 0 3,150 3,150 11 C Door Metal Polystyrene Core 42 1,618 0 368 368 121 Wall R-19+ 1/2"Asphlt Board(R-1.3) 2532 11,420 0 2,590 2,590 15G Wall 5'or More Below Grade 8/12" BIk+R-11 299 1,055 0 0 0 161 Ceiling R-44 Insulation 1043 1,967 0 936 936 19J Floor Over Basement/Encl Crawl Carpet+ R-30 563 808 0 0 0 21A Basemt Floor 2'or More Below Grade 480 945 0 0 0 - - -- ------ - ----______ -- __ __ __ .__ Subtotals for structure: 22,993 .0 7,044 7,044 People: 6 1,380 1,800 3,180 Equipment: 300 1,200 1,500 Lighting: 0 0 0 Ducfinrork: 2,799 0 0 0 Infiltration: Winter CFM: 108, Summer CFM: 144 9,438 3,028 2,302 5,330 Ventilation: Winter CFM: 90, Summer CFM 90 7,876 1 895 1,441 3 336 _ _.._ .___ . _ ..__._ __.___. _______. ______ ._.___ -----.__ __..._ ---------- ._. ---------.-----'------_._-----______.___�____ Sensible Gain Total: 13,787 _Temperature Swin�Mul�lier__ _ ___ X 1.15 Total Building Load Totals: 43,106 6,603 15,855 22,458 Total Building Supply CFM: 665 (1.9 AC/hr) CFM Per Square ft.: 0.259 Square ft. of Room Area: 2,566 Square ft. Per Ton: 1,073 Total Heating Required With Outside Air: 43,106 Btuh 43.106 MBH Total Sensible Gain: 15,855 Btuh 71 % Total Latent Gain: 6,603 Btuh 29 % Total Cooling Required With Outside Air: 22,458 Btuh 1.87 Tons(Based On Sensible+ Latent) 2.39 Tons(Based On 77% Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\John Terrance Homes-3 unit inside unit.rhv Friday, September 05, 2003, 8:52 AM