HomeMy WebLinkAbout2003-P07036 - mechanical PERMIT
CI�Y`OF ORONO Permit Number:
2750 Kelley Parkway- PO Box 66 P07036
Crystal Bay, Minnesota 55323 Permit Type: Me�h��al Pe�its
(952) 249-4600 Date Issued: 11/24/2003
SITE ADDRESS: 651 Sandstone Cr
L.ong Lake,MN 55356
PID: 33-118-23-11-9927
DESCRIPTION:
Proposed Use: Residential
Permit Class: General
Pemut Type: Mechanical Pernuts Permit Sub-type(s): Multiple Mechanical Items
DETAILS:
Approved per resolution#:
Separate permits required:
NOTICES/REMARKS:
FEE SUMMARY: Pernut Fee: $ 88•75 Valuation• $ 7,100.00
State Surcharge Fee: $ 3.55
TOTAL FEE: $ 92.30
APPLICANT: Plymouth Plumbing&Heating OWNER' Dahlstrom Development LLC
6909 Winnetka Avenue N � 7745 Polaris Lane
Brooklyn Park,MN 55428 Maple Grove,MN 55311
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED
AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF
MINNESOTA BUILDING CODE REQUIREMENTS.
APPLICANT PERMITEE SIGNATURE SUED BY SIGNATURE
Covies: 1-File(SiQnitures Required), 1-Atrolicant,1-Monthlv Reuorts, 1-Assessine, 1-Finance Page 1
CtTY OF ORONo APpLICATiON F'OR MECHANiCAI.P�RMiT
gox 66 (2750 Kelley Parkway)
Cryatal Bay, MN S53Z3
r.F,.�.IY�RA��-.��TL-UN .
a, You may apply far cnccha��ic:al [xrmi�s bY 1►uil or ia pereon at the Ciry officcs. Appli�ntions will bc
teviawal and a peiwit wilI be issued within 2 workiag days.
2. Ptrtriit cau�ld will be st�nt by recurn mail aftor $ re�'�ew is completed. PERMITS ARE NOT VA1.iD
rfnrt ■
L1N'TiL Y�U RECEIVE A PER:ti1JT. w�ic_� in��} j��T�EGI�t UK,TtL���F�M�T cA�p
P�STEL� ON T�E JOB SiTE,
3, ceh,�aicg.,Deeiens - Complete calculnt'tocts, details aad speCificatians ere cequircd fur e�h t�wting,
v4ricilatian, humidification-dehumidi�catios, tnd air couditiaaing inatallation including beat lossRieat gain
ealculation. design tc�npet�+lairos.ec;uiPuxnt tatings ancl idantiflcation as to type, manufncturer and model.
Data stiall be preseaud or►form Drvvided. ldauification af anA speciticatic�ns for water heating eqaipment
shail aleo De prbvtdcd.
4. When any new constructioa or remodelin� is involvM, a sepacau building pernut mu�t be obwined.
3. All wark mus[ be donr in accordance with the Unifortn Mec:hanical CodelStnte BuildiAg Code
cequiremenu.
(, All w�ric must be inapectrQ (rouyh•in aad final). Cai) 473-7357. 24-hvur notice requind.
7. Mousc �ieatink Te+�t Rccord must be submitted baforc final•
�i� Cnmpleto a12 items on this applicati�n. Computt tbe ptr'rnit fee. Sign aucl date !he certification.
iNCOM�'Lis'T�' APPI.ICATIUNS Wli.l. NOT �E PROCESSED. 1f you have quations, cs11 473-7357.
Ploase check onc: � ew _y_Additiun .,,,._,,,,�pax� _._._. Replace
�3ttzidcntial Commercial
Joa StTE. / �- d,S-�v,�_ C�i�c-l�- - zip: -
pwncr's Name: �v. Tde�hone Number:
Mailin� Addr+�s: C�3'' �p' ---"--'---
Contraccor's Name: �v�-Ir. P l Inc- Telephone Number: 7�3 S3 3�/35,�
Mailiny Addrevs. �-��c o� c�.�;�.�,��-J�v�-�tY� �,'�� �p. S �r/a--�
cvcTF*� pE�GRII'TIUN
H�A'I'tNG S�'ST£MS �I
{�uantity: _-�--�--
Mo el: G S{rn�IS�I� - - �
���: �-....�.�__ --
�iu� si��: ��, � - -
Input IiTUs: �v� . _— - ----�—
�utput BTUs: - •_ -
CFM: — -
CpC)LdNC SYSTEMS
Qu�ntitY� �`---- - -------
Make: �-V�v�,�c - _ ----_ ---
Modei: I � �'�
'I'or�: - - -
H. Power � _.�--- _
�
! �
.
�UQp BURNING ��Ut
Wooci stove 'th flue
_____. �ood c�mbina ion or add-ou
,_� Facrory �replac with tlue
�! Faccoty Fircptac (s) �___ Freestanding Masonry
Woocl Stove (s) Franktin, otizer
Hranci Name Mode1 No.
Mfgr's Miu., Clc•,xranc;�s, side _` , rear , min. flue dia. �
Y.�e1vTi�r.�lT)UN
No. Kitchea �:xhaust ducted recircutating cfm
No. � Bath Lxhaust (must be ductcd outside) cfm
No. Other F�ns: Locatians cfm
�,J�,�'F�1�AGE (MUST BF APPROV�?D BY FIRE MARSf�AL)
Installation Rem�vai
Fuel Qil: gallons underground inside outside
_,�� LP Gas: galluns
,—,-----_ Other _^...., _ Gas opening
P�'r�T� �i�'r CAI�4ULA��.�N
!. 1.25% of C�n{�afit Pricc* or �+jjti�mucn Fee (S3S.00)
_ 7 f c5� " x .Ol ZS $ �f� .��S�
(contraCt prica)�
�. �tat,� Surc:ha�; *"' Acld the State Building Caie Divisian
SurchNrgc to each permit. . x .0045 $ ���
or $.50, whichever is greater (concreac pria)
3. Po�� and Ha� li i (Qnly mail-in applications} $ __ ,�,54
4: TOTAL �ERMIT kF.E (Add lines 1��3 above) $
" CONTRACT Pf11C�ar 1UB COS7'meana the aetu�il or eatimated dollar um�unt charged for thc percqieted
wo�k including mattrials, labor, protit, and other fixed costs. it is thc asnouut lo be �h�r�ed to thc
ctwt�mer Pur the work�xie. If any tnaterial,equipmeat, labor,or installation nrc furnished by ttu owner,
tenant or any ether putty the reasnnable market value of such items must t�e added to the estunated Cost
or caacract�rlce for pen»tt fCc purpaaes. ln tha event that there is a disputc on thc amount of thc job cost,
1hc City may request the submiaaion of a �9gned copy of she actaal coutract.
"* ?he STA7E SURCHARGC is .QIXlS uf the contract prict under 51,000,000 or S.SO . whichever is
greator. Fnr v�uations aver S l,OQO,flQO call the D�part►nent of Inepection�t Services for tbe pricz.
The uncicrsigned hereby applies tc� the City for issuance of a Mechanicat Pecmit, agrces to do
ali work in strict accurdaru;e with thc vrdinanc:es of the City anci the regvlacions of the Minnesota
Statc Buiidit�g Code. �i c�rtifies that all st$tements made on this application are romplctc, true
and corrrcc.
Applicant's Signatiu�e: - - - y��� Date: _�r�_—3
�—. ._.
Approved By: Date:
RHVAC-Residential 8 Light Commercial HVAC Loads Elite Software Development,Inc.
' lymoufi Plumbing&Heating John Terrance Homes-3 unit outside uni
Brookl n Center, MN 55428-1662 Pa e 1
; Total Building Summary Loads
Component Area Sen Lat Sen Total
Descri tion Quan Loss Gain Gain Gain
3D Window Double Pane Low Emit Wood Frame 278 8,230 0 5,004 5,004
' 11 C Door Metal Polystyrene Core 42 1,618 0 368 368 '
121 Wall R-19+ 1/2"Asphlt Board(R-1.3) 1945 8,773 0 1,990 1,990
15G Wall 5' or More Below Grade 8/12" BIk+R-11 715 2,520 0 0 0 �
161 Ceiling R-44 Insulation 1071 2,020 0 961 961 '
19J Floor Over Basement/Encl Crawl Carpet + R-30 618 887 0 0 0
21A Basemt Floor 2' or More Below Grade 420 827 0 0 0 I
� Subtotals for structure: 24,875 0 8,323 8,323
People: 6 1,380 1,800 3,180
, Equipment: 300 1,200 1,500
Lighting: 0 0 0
; Ductwork: 2,388 0 0 0
' Infiltration: Winter CFM: 108, Summer CFM: 144 9,437 3,029 2,301 5,330
Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336
Sensible Gain Total: 15,065
Temperature Swing Multiplier: X 1.15
Total Building Load Totals: 44,576 6,604 17,325 23,929
Check Fi ures
Total Building Supply CFM: 734 (2.0 AC/hr) CFM Per Square ft.: 0.287
Square ft. of Room Area: 2,562 Square ft. Per Ton: 1,071
� Buildin Loads
Total Heating Required With Outside Air: 44,576 Btuh 44.576 MBH
Total Sensible Gain: 17,325 Btuh 72 %
� Total Latent Gain: 6,604 Btuh 28 %
Total Cooling Required With Outside Air: 23,929 Btuh 1.99 Tons (Based On Sensible+ Latent)
2.39 Tons (Based On 77% Sensible Capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
�
,
I
�
�
C:\Elite\Rhvacw\ProjectslJohn Terrance Homes - 3 unit outside unit.rhv Tuesday, September 16, 2003, 10:19 AM
CG�� �
/a D�TF� TIME
CITY OF ORONO CALLED IN /
INSPECTION N C SCHEDULED �d-/9-03 �
PERMIT NO. COMPLETED �` �
ADDRESS IOS� �����i
�
OWNER CONTR. J�
TELEPHONE NO. �63 -�-g6 ^57�0�
� DESCRIPTION /"/{���'�'{C`e'� — ��
� Ot FOOTING 11 MECHANICAL RI 18 EXCAWGRADING/FILLING
Q 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS
h 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL
Z 04 WALLBD. 12 WATER HOOK-UP 17 SITE INSPECTION
Q OS FINAL 14 SEWER HOOK-UP O6 PROGRESS
� 07 OEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT
v 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP
= 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL
J 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL
� OWNER/CONTRACTOR TO MEET YOU:_YES_NO
c� COMMENTS:
�
W
a
j
O
>.
�
O
�
W
�
Q
�
2
W
�
W
�
j
� �OGORKSATISFACTORY:PROCEED ❑PROJECTCOMPLEfE
W ❑CORRECT WORK 8 PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY
0 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
V BEFOREC�IERiNG PERMANENT
❑CORRECTUNSAFECONDITIONWITHIN HOURS. p pHOTOTAKEN
INSPECTOR WFLL RETURN ❑CITATION ISSUED
❑STOP ORDER POSTED.CALL INSPECTOR
O INSPECTION REQUIRED.CALLTO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. (952) 249-4600
OwnerlContract
Inspector.
White CopyMspectors Fik Canary CopylSNe Notica