Loading...
HomeMy WebLinkAboutseptic info � °� 0 0 ����������-�.�,�-` CITY of ORONO �j ,�i}s,�:�l'i�'�'�-` ►�r �3`. `�\� '��, �; ���°� " �, _ Municipal Offices ���^r ti�� ��i ti � �,�.`�'� �� `'•��� �. - ��3�����',�G% Street Address: °15a a4q'�16� � Mailing Address: ,��� �.E.�.� 4�, .,,\����;�� 2156 Kelley Parkway P.O. Box 66 % Orono, MN 55356 Crystal Bay, MN 55323•0066 To Current Owner: Address: �l�o� � i� �j'^�'`( I�G� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMIT'Y (1-3): I 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the cuaent Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a desigttated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-71: � Tank inspection indicates: 5 Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped �G` -�6 •- C d ). Make sure seatic�anks are aumped throush manhole and not throueh white insnection uipes. This aliows for the aroaer cleanin . Kee ater softner a d iron filter dischar e out of se tic s stem to rolon life of drainfield. Ask um er to test alarm float to veri alarm is still workins in vour house. The alarm warns owner that septaee is about to backup into basement 7 Inspection riisers missing-t�nks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped'out within the last three years,they should be pumped out now. DRAINFIEi�D CONDITION(8=1�0�:--� 8 Drainfield is.dry,no surfacing evident. —._.._...._. _ . _ 9 Some evidence of surfacing;�not cci�icaT yef:—"—""� -""'�`���l--� 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector --- --- _�_. immediately.Repairs must be comple�e`d`within 90 d�ys.---""�— � COMMENTS.__ .._ _ _ �.-,._. .. __ _ ._.,.__.__._.__..__ . _ . __.. .. -- _,_ ..___ _. � �- ��' � � � � Date of Inspection Septic System Inspector � - - - - - � - - •• -