Laserfiche WebLink
, i � <br /> ' .. ����� ��� <br /> New Construction Energy Code Compliance Certificate <br /> P¢Nll OLS Building Certificate.A building certificate shall be posted in a permanently visible Iceation inside the Date Cerafinte Posted <br /> building. The certificate shall be completed by the builder and shall list infonnazion and values of components listed m <br /> Tab1e N1101.8. P�aCe �/DUr <br /> Mailing Address of the Dwdling or Dwelling Unit City � <br /> 1135 Pine View Drive Orono <br /> logo here <br /> Name of ResidrnUal Contractor MN Littnse Number <br /> Mark D Wlliams Custom Homes �J�- ��1 �`'��3 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply Passive No f un) <br /> w. � <br /> o � <br /> a� °_' Active(With fun and monometer or o�he <br /> a >, <br /> F,'' °' " system monitoring device) <br /> .O T <br /> cd V � '_' � 0. N <br /> `" a 3 °' — � � <br /> o � U � 'o <br /> a o n U v � <br /> � Q W W � � � T <br /> c � <br /> Insulation Location � o z � � � o � W � <br /> � � o � �w <br /> ;� b z; <br /> [-°� � � � � � � y � Other Please Describe Here <br /> Below Entire Slab �—1 O <br /> FOundatlon Well �^l 0 X Type in location:interia e�Reria w integraf <br /> Perimeter of Slab on Grade <br /> Rim Joist Foundation Type in locatio¢intenor eutenor w integral <br /> Rim Joist 1�Floor+ R��q T e in�ocation:interiw e�ctena a int ral <br /> Wall Q,`�9 <br /> Ceilin ,flat <br /> Ceilin ,vaulted �-� <br /> Ba Windows or cantilevered areas (Z-S <br /> Bonus room over ara e 1�-)'6 <br /> Describe other insulated areas • <br /> Windows&Doors Heati or Coolin Ducts Outside Conditioned <br /> Avera e U-Factor exc[ades s li hts uru!one door)U: • 3 No[a licable,all ducts located in conditioned s e <br /> Solar Heat Gain Ccefficient(SHGC): � R-value <br /> MECHANICAL SYSTEMS Make-up Air ��e�t p 7ype <br /> 118�CeS Heatin S stem Domestic Water Heater Coolin S stem Not re uired r mech.code <br /> Fue�7' e NATURAL GAS NATURAL GAS ELECTRIC Passive <br /> Manufacturer DAIKIN/SLANT FIN DAIKIN Powered <br /> Interlocked with exhaust device. <br /> Model DM96HS090/CSH85 DX13SN048 Describe: <br /> Input in 175,000 Capaciry 9n Output in Q_TON Other,describe: <br /> Ratin or Siu BTUS: Gallons: Tons: <br /> Heat Loss ll 7,956 Heat Gain: 45,808 Location of duct or system: <br /> Structure's Calculated <br /> AFUE or 96% SEER: 13 SEER <br /> HSPF�/o <br /> Calculated 4TON <br /> Efficienc cooling load Cfm's <br /> "round duct OR <br /> Mechanical Ventilation System °metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a T e <br /> source heat pump with gas back-up fumace): Not re uired r mech.code <br /> Selee!T e Passive <br /> X Heat Rewver Ventilator HRV Ca ci in cfms: Low: 117 Hi h: 189 Other,describe: <br /> Ener Recover VentilaYor ER Ca ci in cfms: Low: Hi : Location of duct or system: <br /> Continuous exhaustin fan s rated ca i in cfms: <br /> Location of fan(s,descnbe: Cfm's <br /> Ca aci continuous ventilation rate in cfms: "round duct OR <br /> Total ventilation intermittent+continuous rate in cfms: "metal duct <br /> R�eEIVED <br /> JUL (�8 2014 <br /> Created by BAM version 052009 <br /> CITY OF ORONO <br />