My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00312 - retaining wall
Orono
>
Property Files
>
Street Address
>
P
>
Pine View Drive
>
1135 Pine View Drive - 28-118-23-42-0008
>
Permits/Inspections
>
2015-00312 - retaining wall
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:34 PM
Creation date
7/5/2018 2:11:05 PM
Metadata
Fields
Template:
x Address Old
House Number
1135
Street Name
Pine View
Street Type
Drive
Address
1135 Pine View Drive
Document Type
Permits/Inspections
PIN
2811823420008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�. <br /> CIVI <br /> LDESIGl�T <br /> � � �::v .. r � �: . . -� .-� �_ �, �RONO COPY <br /> INNOVATNE ENGINEERING SOLUTIONS I � .P'� ��� �,, <br /> March 11, 2015 '��5_ Q��'L, <br /> Matt Gerken <br /> Southview Design <br /> RE: Vanyo Landscape Retaining Walls(15-0136) <br /> Orono, Minnesota <br /> Design Assumptions: <br /> Boulders, 15.0°Wall Batter , <br /> Coulomb Design ' <br /> Live Load: 50 PSF <br /> Dead Load: 0 PSF <br /> Toe Slope: None <br /> Back Slope: None <br /> Seismic: N/A <br /> Bearing Capaciry: Approximately 1,500 PSF <br /> Soil Design Properties: � y c <br /> Retained Soil 34° 120 PCF 0 PSF (Select Granular) <br /> Foundation Soil 26° 120 PCF 0 PSF (Sandy Lean Clay) <br /> Notes: <br /> No soils information was provided for this final design. The onsite material is assumed to be a sandy lean clay <br /> with an internal friction angle of 26". Where unsuitable soils are found, a subcut may be required and <br /> structural fill shall be placed and compacted to provide an adequate bearing foundation. The above minimum <br /> soil strength parameters shall be verified by the project geotechnical engineer prior to construction. CDP shall <br /> be contacted if the above soil strength parameters cannot be met and a redesign may be required. <br /> Wall layouts and elevations obtained from plans provided by Matt Gerken of Southview Design. <br /> We appreciate the opportunity of providing services to you. If you have any questions or comments regarding <br /> this project, please feel free to contact us. <br /> Sincerely, <br /> Civil Design Professionals <br /> Laura R. Blonigen <br /> Project Engineer <br /> Civil Design Profe,sionals . 8609 Lyndale Ace.S.,Stiite 300 Bloomiugton,MN 554Z0 . Offi�e(952)iO3-53t2 . www.cdp-u�.�on, <br />
The URL can be used to link to this page
Your browser does not support the video tag.